July 29, 1992 Dow U.S.A The Dow Chemical Company P 0 Box 150 Plaguemine, Louisiana 70765-0150 Daniel Cortez Eddie Guillory Petrin Petrin Building 4106 cc: Rock Gustin LHC II Building 4801 Asbestos Monitoring Enclosed are sample results for potential exposure to asbestos. The OSHA 8-hour permissible exposure limit for asbestos is 0.2 f/cc >5 microns and the 30-minute short term exposure limit is 1 f/cc >5 microns. The results displayed are based on sampling duration. The data sheet shows the results of exposure using two methods, the Limit of Detection (LOD) and the Limit of Quantitation (LOQ). Included on the data sheet is an explanation of the method Limit of Quantitation. Thank you, DarleneS. Creel Industrial Hygiene Ext. 6181 Building 3502-E Attachment dsc produced for the asbestos database D0 A 114839 CONFIDENTIAL LOUISIANA DIVISION INDUSTRIAL HYGIENE SAMPLE RECORD SAMPLE N2 1 4071 PLANT/DEPT. _ MONITORING FOR' DATE / OTHER CHEMICALS PRESENT: _ SAMPLE COLLECTION MEDIA: ''BADGE NO. TYPE, TEMP/HUMIDITY: (REQUIRED FOR BADGES), CHARCOAL TUBE RI7E ''FILTER CASSETTE SI7F.Z-.i- SILICA TUBE SIZE____________________ DRAGERTUBE TYPE___________________ OTHER _______________________________________ SHIFT. 0'SHR. 12 HR. PERSONNEL SAMPLE 0'FL/LL SHIFT TWA O STEL/TASK AREA SAMPLE \ EMPLOYEE NAME -30.EMPLOYEE I.DmJUK. JOB CLASSIFICATION IiHn JjOudB CuOuuDEc w --. CONTRACTOR COMPANY _ RESPIRATOR USED7 OYff NO RESPIRATOR MODEL / CANISTER TYPE MOUTH-BIT DUST 77/la ''HALF-FAJ2S FULL-FACE AIR-LINE SCBA DESCRIPTION OF AREA SAMPLED/JOB PERFORMED DURING MONITORING XI 7'UmFiPUMP SERIAL NO. J2. CALIBRATION DEVICE BBLEMETER OTHER_________ ROTAMETER PUMP FLOW RATE CALIBRATION: BEGIN. 1. jL# 9>L 2 3 BEGINNING FLOW RATE AVG.3'TOO ENDING. 1 / ? 43AlM_ 3 /,?.,rtf ENDING FLOW RATE AVG. / ? Cl S' CC/MIN L/MIN - nrv \ O-tC/MIN L/MIN SAMPLE AVERAGE FLOW RATE 13SL TIME STARTED. Xiao. TIME STOPPED. f- ic TOT. RUNNING TIME(MIN). 'i.T SAMPLE VOLUME (AVG FLOW X RUN TIME) *7~77' - -ST ANALYTICAL REPORT REEFFEERREENNCCEEi# ANALYTICAL RESULTS: ap-lsor. ' RESTRICTED FOR USE WITHIN DOW ONLY ' Lo D -T.j<o0Q^9 FORM FILLED IN BY LOUISIANA DIVISION INDUSTRIAL HYGIENE SAMPLE RECORD SAMPLE N2 1 40 9 4 PLANT/DEPT. t f4\C IT MONITORING FOR DATE-------------------------------------- ISjJj-f1 >------ F. faf'S OTHER CHEMICALS PRESENT.--------------------------------------------------------------------- SAMPLE COLLECTION MEDIA; BADGE NOTYPE- TEMP/HUMIDITY. (REQUIRED FOR BADGES) CHARCOAL TUBE SIZE O' filter cassette si7f s' r*yn SILICA TUBE SIZE____________________ _____ DRAGERTUBE TYPE ............ ............................. OTHER SHIFT: 3^ HR D12HR. '"PERSONNEL SAMPLE AREA SAMPLE FULL SHIFT TWA STEL/TASK employee name 'TV-jupr ___________________ EMPLOYEEI.D.# H 35-19 - fjS'.j-j -------------------------------------- JOB CLASSIFICATION XT*FlaAr _ IH JOB CODE #__________________ , CONTRACTOR COMPANY___________Kt4r.*______ LaXp.----------------------- _ PUMP SERIAL NO. CALIBRATION DEVICE: ^ A-- 9`SUBBLEMETER ROTAMETER OTHER________________________________ PUMP FLOW RATE CALIBRATION; BEGIN: 1. >riLr ^ri<i K JYll---- BEGINNING FLOW RATE AVG. S~i Y ENDING. 1 a HUM 2 JT. 3.IM ENDING FLOW RATE AVG. ^-i O^CC/MIN 0 l/MIN 9'Wf' "tC/MIN L/MIN SAMPLE AVERAGE FLOW RATE TIME started //? A>0 fr'V_________ TIME STOPPED 10 ^ 0 *""1 TOT. RUNNING TIME(MIN) ,TO -- RESPIRATOR USEDT 3"YES NO ,, // RESPIRATOR MODEL/ CANISTER TYPE MOf**-____ "} 7PQ_____LV//WP MOUTH-BIT DUST 0"TlALF-FACE / SAMPLE VOLUME (AVG FLOW X RUN TIME) FULL-FACE AIR-LINE SCBA DESCRIPTION OF AREA SAMPLED/JOB PERFORMED DURING MONITORING _ jC , 7tuMd?._____________________ "3 ANALYTICAL REPORT REFERENCE * ANALYTICAL RESULTS: OW'D____ ___ _______ RESTRICTED FOR USE WITHIN DOW ONLY * . _______ LbO 7 P.'S) FORM FILLED IN BY: DO A 114840 CONFIDENTIAL ASBESTOS MONITORING DATA RESULTS: LHC 11 1M2 "LOD ***LOQ EXPOSURE GUIDELINES 8-HR. TWA LIMIT-0.20 FIB/CC 30-MINUTE LIMIT = 1.0 FIB/CC LIMIT OF DETECTION = 7 FIB/MM2 LIMIT OF QUANTITATION = 100 FIB/MM2 DATE SAMPLE# PERSONNEL DESCRIPTION DUR(M1N) 6/15/92 14071 *436-74-3503 Insulator: WET METHOD used while removing Asbestos from 1" pipe 30 7/17/92 14094 *433-19-6528 Insulator: WET METHOD used while removing insulation from 3" steam line 30 VQL(L) 58 76 "LOD FIB/CC 0.03 <0.01 "*LOQ FIB/CC <0.68 <0.51 * The proper protective clothing was worn during the job. North 7700 Respirator with HEPA filters were worn during the job. Note: The Limit ot Quantitation has been defined as 100 Fibers/MM2 using the minimum fiber loading criteria specified. In the NIOSH analytical method 7400, the stated range of the method is 100 to 1300 Fibers/MM2 filter area. Although samples below this range can be analyzed, the method has not been validated below too Fibers/MM2. However, the NIOSH method 7400 also establishes the estimated Limit of Detection as 7 Fibers/MM2 (Reference OSHA Std. 1910.1001, Appendix B). Based on this information, we will establish 100 Fibers/MM2 filter area as our Limit of Quantitation and 7 Fibers/MM2 filter area as our Limit of Detection (which is more representative of the actual fibers present) for asbestos monitoring. We will report both Limit of Quantitation and Limit of Detection. If only Limit ot Quantitation were expressed, the minimum reportable result would calculate to be 0.04 Fibers per cc for an 6-hr. Time weighted average sample at a flow rate of 2 titers per minute and 0.6 fibers per cc for a 30 minute time weighted average short term sample at a flow rate of 2 liters per minute. DOW CONFIDENTIAL 00 M l ) 4d4 i f.ONFTDrNITTAl