Document DG12dekaRGy2g9Z9wNeKXeLNn

Monsanto rnoM .nmc . location, c. Edwards Mi MBiiiiiia ;iiwr subject September 13, 1976 . Asbestos Insulated Pipe REFERENCE t TO R. E. Belden H. H. Cole F. H. Dupre D. R. Kreitz PLAINTIFFS ^EXHIBIT -MON--15 Pipe covered with asbestos containing insulation is a potential exposure source of asbestos. There is this type of pipe in the plant scrap yard. All material containing asbestos must be disposed of by sealing in a properly labeled container and buried in an approved area. Therefore, to assure that exposure to asbestos is minimized and the disposal of it is proper, I strongly recommend that all pipe be stripped of its insulation before placing it in the scrap yard. Stores will not accept anymore insulated pipe into the scrap yard until this problem is resolved. They will also be contacting you for help in cleaning up the insulation which is now in the scrap yard. i JCE/dg J. C. Edwards IN 1C REV. 1/72 C 003145