Document DDy6QRnNv1k2EMjjzaKr9kNvO

694 CHAPTER 51 1959 Guide sweat output is automatically limited by the body to that amount which satisfies the required value of E. With re stricted evaporation, however, there is excessive sweating; the body becomes fully wetted and a matimum evaporative cooling rate is established which does not increase with fur ther sweating. This matimnni evaporative cooling rate has been established experimentally and can be calculated by the equation: Em** m KJLV*-*{P, - P.) = 10K* *(P. - P.) (5) where K. = coefficient of heat exchange by evaporation, Btu per (hour) (square foot) (unit velocity) (millimeter of mer cury vapor-pressure difference). 10 -- K,X. A for average sise man, fully wetted. P, - vapor pressure of water at skin temperature, milli meters of mercury. Pm -- partial pressure of water vapor in ambient air, milli meters of mercury. A combination of Equations 4 and 5 yields Equation 6 which is a statement of the maximum thermal conditions un der which man can mainfAin heat balance, giving proper recognition to internal heat production Af, skin temperature t, and to all four of the thermal characteristics of the en vironment: H + 220, - (.) + 2 Vv(U - M - 10V (/\ - P.) (6) Equation 6 provides a rational basis on which to construct a heat stress index and to establish thermal standards for different industrial work situations. Two physiological criteria are important in fixing the limit of sustained heat exposure: 1. The increase in body heat content must not exceed a cer tain leveL Practically, this is reflected in the rise in skin tem perature. This temperature may be limited to 95 F. 2. Thermal balance must be accomplished with a rate of sweating not greater than one liter per hour (equivalent to evaporative cooling of 2400 Btu per hr). Studies on young ac climatised subjects have shown that this maximum rate of sweating can be maintained over a workday without undue strain or physiological cost. The Heat Stress Index (ESI) proposed by Belding and Hatch1 makes use of these criteria together with the previous biophysical equations. A so-called standard young man, in good physical condition and acclimatized to beat, can safely engage in simple physical work over a normal eight-hour day in a particular thermal environment so long as his skin tem perature does not exceed 95 F and he maintains thermal balance with a sweat rate not exceeding 1 liter per hr. By definition, this degree of stress has an (HSI) value of 100 and is given by any combination of M + R + C which is balanced by * within their defined limits. For other situa tions where is greater or less than ( 2400 Btu per hr), the value of (HSI) is proportionately different from 100: (HSD - 100 X (7) By using the globe thermometer temperature (see Chap ter 52) of the environment to represent the combined effects of mean radiant temperature and air temperature, the Heat Stress Index chart Fig. 1 has been constructed, to permit quick determination of (HSI) when M,tr, and air velocity are given. The procedure for finding (HSI) will be obvious by following the Hush line in Fig. 1. The Heat Stress Index was developed from research ex perience with young men in good physical condition and well acclimatized to heat. Table 2 assigns suggested physiological meaning to (HSI) values above and below 100, for older men as well as the standard young man and, also, for various kinds of jobs which differ in their demands upon mental and physical effort. From these it becomes possible to select (HSI) levels appropriate to each work situation. The Heat Stress Index (HSI) differs from the Effective Temperature (ET) scale in the rational rather than subjec tive basis of its construction. Practically, the commonly recommended E7T = 80 F for heavy work at moderately high air velocity agrees very well with the (HSI) limit of 100 for acclimatized young men. In Fig. 2 are shown the combina tions of dry- and wet-bulb temperature (air and wall tem perature alike) for three different air velocities and three Table 2 .... Evaluation of Index of Heat Stress (ndcx of Heat Sires Phyaaiogkai and Hysimic tapficcHoo* of 8-Hr Expatom to Various Hoot Slreset -20 Mild cold strain. This condition frequently exists in -10 areas where men recover from exposure to heat. 0 No thermal strain. +10 20 30 Mild to moderate heat strain. Where a job involves higher intellectual functions, dexterity, or alert ness, subtle to substantial decrements in perform ance may be expected. In performance of heavy physical work, little decrement expected unless ability of individuals to perform such work under no thermal stress is marginal. 40 Severe heat strain, involving a threat to health unless 50 men are physically fit. Break-in period required for men not previously acclimatised. Some decre ment in performance of physical work is to be ex pected. Medical selection of personnel desirable because these conditions are unsuitable for those with cardiovascular or respiratory impairment or with chronic dermatitis. These working conditions are also unsuitable for activities requiring sustained mental effort. 70 Very severe heat strain. Only a small percentage of the population may be expected to qualify for this work. 90 Personnel should be selected (a) by medical exami nation and (b) by trial on the job (after acclimati sation). Special measures are needed to assure adequate water and salt intake. Amelioration of working conditions by any feasible means is highly desirable, and may be expected to decrease the health hazard while increasing efficiency on the job. Slight indisposition" which in most jobs would be insufficient to affect performance may render workers unfit for this exposure. 100 The maximum strain tolerated daily by fit, acclima tised young men. - Control of Hie Industrial Environment 695 different grades of work, all of which give (HSI) = 100. Points representing ET = 80 F.jvith an air velocity of 300 fpm are also shown for comparison. CONTROL OF HEAT EXPOSURES Measures for control of heat exposures will be treated un der the following headings: Control at Source, Local Exhaust Ventilation, Radiation Shielding, General Ventilation, Dilu tion Ventilation, Local Relief Ventilation. Control at Source The magnitude of heat exposure can be reduced by insulat ing hot equipment, locating such equipment most favorably (in zones of good general ventilation within buildings or even outdoors), covering steaming water tanks, providing covered drains for direct removal of hot water, and maintaining tight joints and valves where steam may escape. This method is an obvious- one and requires no particular comment other than to emphasize the benefits to be derived from elimina tion of heat sources wherever possible. Local Exhaust Ventilation The natural convection column of heated air rising from a hot process may be captured by means of ventilated enclo sures or exhaust hoods and removed with a minimum of dilu tion by air from the surrounding space when local exhaust ventilation can be used. Chapter 52 provides detailed infor mation on the design of exhaust hoods and duct systems for local exhaust. Radiation Shielding In some industries, commonly referred to as the hot in dustries, there are many hot objects and surfaces such as furnaces, ovens, furnace flues and stacks, boilers, molten ma terial, and hot ingots of metal, castings, or forgings and, in consequence, the major environmental heat load is in the form of radiant heat. Since air temperature has no significant influence on the flow of radiant heat, ventilation is of no help in controlling such exposures. The only effective control is the direct one of decreasing the amount of radiant heat im-