Document DDxxmeRzOq621Dm1aqjEmd2NN
JARD Company Inc.
Bennington, Vermont 05201
26 April 1976
(802) 442-3173
ANSI C-107 CAPACITOR SUB-COMMITTEE
Dear Committee Member:
Attached is an extensive rewrite of the capacitor section of the ANSI C=107.1-1974 including the revisions per our February meeting. Primarily, the overall rewrite was done to improve readability. It is requested that each of you review this draft carefully. All comments should be submitted by May 21, 1976, otherwise the draft is considered to have been found acceptable.
Very truly yours.
JARD COMPANY, INCORPORATED
'1
.
Richard L. Rollins Vice-President Engineering
RLR:m
cc: EL Raab . CR Willmore
DSW 324043
STLCOPCB4075374
3. CAPACITOR GUIDELINES
,
3.1 General. The environmental effects of askarels are under in-depth study by
governmental and other agencies. Askarels have been considered relatively harmless to
humans based on about 40 years of safe industrial usage. There has been no known instance of human injury when they were used under the normally accepted precautions and conditions
of handling in both manufacturing'and user applications.
Traces of askarels are being found in the environment and in fish and bird life. The
long-term genetic and ecological effects are not yet completely understood. For these
reasons, care should be taken to contain askarels and minimize their entry into the
environment.
.
There are two general classes of askarels used by the electrical industry. The higher
chlorinated grades are the more persistent in nature. Because of their high degree of
nonflammability, they are used in transformers where personnel safety is of paramount *
importance.
--
Capacitor-grade askarel has a lower degree of chlorination (composed primarily of the
3-=chlorine isomers of biphenyl) and a higher degree of biodegradability. Generally, it
has not been found in animal life. It is used in capacitors, where the extreme degree
of nonflammability required in transformers is of less importance.
Although capacitor- and transformer-grade askarels both contain members of the PCB family, they do differ in composition, degree of biodegradability, persistence in nature,
electrical stability, chemical stability, and degree of nonflammability (both are recognized as nonflammable). It is for these reasons that Section 3 of this standard
is intended to apply to capacitor-grade askarel.
DSW 324044
STLCOPCB4075375
3.2 Capacitor Grade Askarel. In September 1971 a new grade of capacitor impregnant,
Aroclor 1016, was made available to the industry. This new grade contains a typical r; .'
...?> concentration of 0.4%/by weight of the higher boiling homologues of the chlorinated
biphenyls. (See ASTM D3303-74 7lj .) Aroclor 1016 replaces Aroclor 1242, which
previously was the major capacitor impregnant and contained around 7% of the higher
' boiling homologues (the more persistent in nature). This 0.4% level of the higher
boiling homologues should be the maximum concentration acceptable in any capacitor impregnant. Aroclor 1242 and 1254, previously used as impregnants, do not meet this
requirement and should no longer be used in capacitors designed and manufactured for
alternating-currentapplications.
'
Aroclor 1016 has the same Underwriters' Laboratories, Inc. nonflammability rating
as Aroclor 1242. Its typical properties are given in Table I. Commonly used solvents include benzene, kerosene, acetone, trichloroethane,
trichloroethylene, and perchloroethylene. Typical vapor pressure data for Aroclor 1016
are:
0C= 0.001 mmHg 25C= -006 """H? 150 C= 4.3 mmHg 200C= 29.0 mmHg,
,.
At 25C and 760 mmHg pressure, saturated air contains approximately 0.09 mg/1.
Note: 1 mg/1 = 90.0 ppm (v/v) 1 ppm (v/v) = 0.011 mg/1
.
3.3 Employee Safety and Plant Housekeeping. The procedures and limits given in 3.3
are intended to be minimum requirements to be met by manufacturers and users of
'
capacitors containing askarel. Handling, control, and disposal procedures are given, together with exposure limits and indicated antidotes and clean-up procedures.
3.3.1. General Safety Precautions. Although it is generally accepted that exposure to capacitor-grade askarel is not hazardous provided that simple precautions are
taken, exposure should still be avoided. 3.3.1.1. Vapors. The odor of askarel is noticeable well below the maximum air concentrations considered safe. Up to 1.0 milligram per cubic metre of air has been
determined to be the maximum safe level of exposure during an 8-hour workday. (See DSW 324045
3 Numbers in brackets refer to corresponding numbers in 5.1, P^ferences to the Text.
STLCOPCB4075376
reference 19 ). The procedure for performing the necessary analyses is contained in Section B3 of Appendix B. This procedure or its equivalent should be used.
Breathing vapor or fumes from heated askarel should be avoided. Provisions should be made for adequate ventilation and regulation of manufacturing operations to avoid open exposure to askarel (especially at temperatures of 55C or higher). The gases
produced when askarel is decomposed by very high temperatures (such as that of an electric arc) in the presence of "air or organic insulating materials contain a very high'
percentage of hydrogen chloride, and small percentages of carbom dioxide, carbon .monoxide, and oxygen. Minute concentrations of this combination of gases are very
unpleasant and irritating, thus giving ample warning of their presence. If exposure to high concentrations of askarel is necessary under emergency conditions, an approved gas mask or self-contained breathing apparatus should be worn. Such exposure should be under the surveillance of other personnel capable of effecting rescue in case of an accident. If the odor of askarel is detected by the person wearing protective
equipment, he should immediately go into fresh air. All gas masks, respirators, and replacement parts should have U.S. Bureau of Mines approval and be maintained on a
regular schedule in accordance with the manufacturer's recommendation. 3.3.1.2. Liquid. In contrast to the situation in which mineral insulating oils are handled, there is virtually no fire hazard in handling askarel. A limited solvent
'
action (similar to that for paint thinner) on the fats and oils of the skin with prolonged contact may lead to drying and chapping of the skin. As with insulating
oil, some people are allergic to askarel, and continued exposure may result in-skin
irritation. Both the liquid and vapor are moderately irritating'to eye tissue.
Operating procedures should be such as to minimize or eliminate contact with
askarels. Use of eye protection is recommended. The use of porous gloves that can
absorb and retain askarel is to be avoided.
Barrier creams4 or resistant gloves 5
4 For example, PLY No. 9 Gel (Milbum Company, Detroit, Mich), or Kerodex No. 71 (Ayerst Laboratories, New York, N.Y.), or the equivalent.
%or example, Edmont - Solvit 5-352 (Mersick of Bridgeport, Bridgeport, Conn), or the equivalent.
DSW 324046
STLCOPCB4075377
should be used if contact is unavoidable. Use of enclosed transfer and handling equipment, processing equipment, and mechanical washers reduces direct contact.
Medicinal washes or mild detergents followed by the application of cold cream will reduce the irritation resulting from the contact of an open cut or abrasion with askarel.
Safety glasses with side shields or a face shield should be worn when handling askarels. If liquid askarel contacts the eyes, the eyes should be irrigated immediately with large quantities of running water for 15 minutes and then examined by a physician (A drop of caster oil has been found to reduce irritation).
Persons developing a skin irritation or respiratory tract irritation while working with askarels should be placed under the supervision of a physician. Ingestion or swallowing of askarels is not generally regarded as a problem of the industry. Should accidental ingestion occur, a physician should be consulted.
Hands should be cleaned of askarel before eating, drinking, smoking, or using toilet facilities by means of waterless hand- cleaners** and wipe towels which should then be properly disposed. 3.3.2 Bulk Fluid Shipment, Receiving and Transfer. Shipment of askarel from point of manufacturing to point of receiving should be done in closed containers such as rail tank cars, truck tanks, marine or barge tanks, or sealed drums. In. case of an askarel spill during bulk fluid shipment, reference should be made to paragraph 3.7 which provides procedures for control and listed authorities to be notified. Containers should be labeled as to contents and carry a label cautioning against loss of fluid to the . open environment. Containers used to transport askarel should not be used for storage or to transport other material without being completely cleaned of all traces of askarel. (Cleaning procedures must take cognizance of precautions against excessive exposure and of the need for proper disposal of contaminated cleansing solvents and materials as set forth in 3.5) Transfer from shipping containers to processing systems should be through closed piping or tubing with appropriate valves, pumps, etc. Provision should be made for trapping and disposing of fluid lost by leakage or spills from the
6For example, Pow'r Xleen Handcleaner, (Woodbine Chemical and Research, Inc., Medina, Ohio or Man's Hands, Oak Industries, Inc., Hoosick Falls, N.Y.)
DSW 324047
/
STLCOPCB4075378
transfer system and from the storage containers. Drums to be retired from use should be cleaned before crushing, delivery to
scrap dealers, or other disposal. Contaminated cleaning fluids and materials should
be disposed of as indicated in 3.5.
*
3.3.4 Manufacturing Housekeeping. Manufacturing equipment and operating procedures
should safeguard against loss of askarels to-the environment through proper containment
and disposal procedures. 3.3.4.1 Processing Area Control. Enclosed systems of sealed piping properly gasketed joints, valves, containers, and processing chambers should be used for any portion of the operation where.askarel temperatures may exceed 55C. Enclosure should preferably
extend to all other portions of the system insofar as practicable.
'
Containment provisions should be established around all askarel processing areas to
ensure against inadvertent loss to sewer systems by spillage, leakage or other
uncontrolled conditions or events. 3.3.4.2 Types and Control of Liquid Askarel Wastes. Askarel-containing liquid wastes
may occur in manufacturung from sources such as the following: 1) Liquid askarel contaminated (during processing which is unsuitable for reclaiming as a dielectric
. '
fluid, 2) liquid askarel from solvent operations or water and detergent type washers, 3) vacuum pump oils contaminated with askarel, 4) steam jet vacuum system condensates contaminated with askarels, and 5) askarel containing materials from laboratory samples.
Waste fluids containing askarel should be collected (by means of traps, drip pans, trays, etc) and disposal should be in accordance with 3.5.
Spills of askarels should be removed promptly by means of absorptive material, such as sawdust, or trapped and removed by pumping or other suitable means. Disposal should be per'3.5. 3.3.4.3 Types and Control of Other Askarel Containing Wastes. Saturation of materials with askarels may occur in manufacturing from the following sources: 1) Saturated earth or other absorbent media from filtering operations or from cleaning up spills, 2) saturated filters from vapor control devices and other filters, 3) saturated wastes such as paper, rags, etc. 4) saturated spent gasket materials and 5) capacitors failing tests or
DSW 324048
STLCOPCB4075379
otherwise designated for disposal. All of the above items should be collected for proper disposal. Wiper rags,
protective clothing^ and other extraneous materials which are likely to be soiled should
preferably be made of disposable materials. Other materials should be collected within
the containment area for properly controlled laundering.
3.4 Control of Plant Effluents
*
3.4.1 Water Effluents. The industry goal is to eliminate askarel in plant water
effluent streams. However, it is recognized that existing drain' systems in capacitor
manufacturing plants are probably contaminated as a result of past practices, and askarel
traces may continue to decrease with the proper containment of askarel wastes and no
further discharges into drain systems. Other sections of this standard provide that no
askarel wastes of any kind be disposed of in any water effluent streams and that
accidental spills be prevented from getting into such streams.
3.4.1.2 Concentration Limits. A 1975 proposal by the Environmental Protection Agency
(EPA) is to keep the PCB levels in rivers and lakes below 0.001 parts per billion (or
1 part per trillion). This is currently under review by the EPA and standards are
expected to be promulgated in 1976. Plant jeffluent streams should be managed and
controlled in a manner anticipating these government standards.
3.4.1.3 Monitoring Streams. On a regular basis consistent with plant situatinns, all
.effluent streams should be analyzed. The procedure for performing the necessary analyses
is contained in Section B3 of Appendix B. This procedure or its equivalent should be
used.
3.4.1.4 Methods for Minimizing Effluent Stream Contamination. The ideal approach is to
isolate totally all effluent streams that could be contaminated with askarels during manufacturing processes and prevent them from being discharged from the plant. Carbon
adsorption, limestone beds, and solvent extraction are techniques that can be applied
to reduce the askarel content of effluent streams. These techniques may be most useful
in cleaning up water used in plaint processing and to permit recycling.
^For example, Edmont-Wilson, 1294 Walnut St, Coshocton, Ohio 43812, or Slosman Corp.,
P.0, Box 3014, Asheville, N.C. 28802.
DSW 324049
STLCOPCB4075380
3.4.2 Air Effluents. The industry goal is to eliminate askarel vapors in plant air
effluents. Plant operations involving askarels at elevated temperatures in excess of
55c should be performed, wherever possible, within closed systems. Filtration of plant
air effluents, to minimize PCBs entry into the.environment, should be accomplished where
N. ' // /i *
evolvement of air borne PCBs'occur from open operations.
3.4.2.1 Monitoring Streams. All plant air effluents should be sampled and analyzed on
a routine basis consistent with plant situations. The procedure for performing the
analyses is given in Section B3 of Appendix B.
3.5 Scrap-Disposal Procedures. The manufacture and use of capacitors involve processes
which produce askarel-saturated solids and liquids containing or composed entirely of
askarel, which should be disposed of as wastes. Specific sources of these materials are described throughout this standard. They may be placed into three categories:
. 1) Capacitor units impregnated with askarel, production and field rejects
' 2) Manufacturing process liquid wastes containing askarel
3) Solid waste purposely or accidently saturated with askarel
Disposal should be done in a manner which is consistent with proper concern for
.
the environment and minimizes any release of askarels to the environment.
.
3.511 Disposal of Capacitor Units. Scrap capacitor units can be generated during
manufacturing processes or during field service. Production rejects are those capacitors
that are rejected after the impregnation process'in the course of production by the capacitor manufacturer. They may be rejected for mechanical or- electrical reasons.
'
Field rejects are those units that are rejected or, for other reasons, are to be
scrapped after shipment from the plant where they were manufactured. Capacitor units should be disposed of intact or, if leaking, in sealed drums.
The small amount of liquid to be drained, the integrity of intact units and the necessity for complex control over drainage procedures make intact disposal preferable.
3.5.1.1 Production Rejects. Rejected capacitors in capacitor manufacturing plants
represent a concentration of askarel. It is therefore important that disposition be made
in a manner consistent with proper concern for the environment. Preference should be
DSW 324050
STLCOPCB4075381
given to disposal of capacitors in sites approved for toxic and hazardous waste disposal. Another alternative would be disposal in supervised dry landfill sites that
meet all applicable state requirements. Care should be exercised to insure that no loss of liquid will occur during
transportation to the disposal site.
.
Incineration of scrap capacitors in facilities designed to accept such solids would
provide a preferential alternative to dry landfill sites when such services become
available.
3.5.1.2 Field Rejects. Wherever practical, all askarel containing capacitors should be
removed prior to disposal of equipment. This precaution will enhance environmental
control procedures and insure that by removing these capacitors they do not ultimately
disperse their askarel contents into a landfill site which does not meet all applicable
state requirements.
-
After removal from equipment, capacitors should be disposed in accordance with the procedures for production rejects (3.5.1.1). Where removal of askarel-containing capacitors from equipment is not practical, that equipment should be disposed of only in supervised, dry landfill sites meeting all applicable state requirements. 3.5.2 Disposal of Liquid Wastes. All waste askarel or liquid wastes containing askarel should be disposed of in accordance with one of the procedures given in 3.5.2.1 or 3.5.2.2. However, preference should be given to incineration, 3.5.2.1. 3.5.2.1 Incineration. Proper incineration must involve a suitable balance between dwell time and temperature in the incinerator plus oxygen availability, and finally,
suitable scrubbers to remove the' HCL that will be formed; for example, 2-second dwell time at 2000F and 3% excess oxygen in stack gas, or 1.5 second dwell time at 2700F and 2%
excess oxygen in stack gas. These facilities should meet the applicable state requirements and should control
effluents within the limits set forth in this standard. 3.5.2.2 Toxic and Hazardous Waste Disposal. Where incineration is not feasible, sites which have been classified by state agencies as suitable for disposal of toxic and
hazardous liquids should be used (See Appendix A).
DSW 324051
STLCOPCB4075382
3.5.3 Disposal of Solid Wastes (See 3.5.1 for scrap capacitors) All solid wastes which
have been saturated with askarel should be disposed of by the following procedure:
1) The saturated wastes should be placed into leakproof containers and transported
to a supervised dry landfill site meeting state requirements. Alternatively, they can
be disposed of by incineration in state-approved facilities.
,
2) Solid absorbents used for spills can be disposed of uncontained in the supervised
dry landfill site; transport to the site should be in closed containers. Alternatively,
they can be disposed of by incineration in accordance with 3.5.2.1 (See Appendix A for
a listing of facilities.)
.
3.5.4 Packaging and-Shipment
3.5.4.1 Transportation to the disposal facility should be in containers that will
prevent leakage and accidental loss of askarel to the environment.
'
3.5.4.2 Containers should be labeled as to contents and precautions relative to loss to
the environment .* 3.5.4.3 Containers used for this purpose cannot be used for any such materials or retired
from service until they are completely cleaned. Any solvents used in cleaning these
containers will be contaminated with askarel and should be disposed, of according to the
same procedures described in 3.5.2.
3.6 Labeling. Capacitor units vary greatly in size and in end use or.application. Small
capacitor units are frequently applied as a component of another piece of equipment, such
as a fluorescent lighting ballast, a roadway or area lighting luminaire, a motor, etc.
M-
In such applications a label on the capacitor unit referencing approved disposal procedure
would not normally be visible when the piece of equipment is disposed of.
For the foregoing reasons the methods of providing disposal instructions for small
capacitors and large capacitors are treated separately in 3.611 and 3.6.2, respectively.
3.6.1 Small Units. Small capacitors are defined as those that contain askarel in
'
quantities up to about 2 pounds each and in which the free liquid does not exceed 0.4
pounds. They are hermetically sealed in metallic cases. It is recommended that shipping
containers from capacitor manufacturers should be labeled as to contents and that
transporters be given instructions, in accordance with paragraph 6.2 as to procedures in
DSW 324052
STLCOPCB4075383
the event of a spill. The label should contain, as a minimum, the following information: Caution: Contains PCBs (askarel) which are environmental contaminants. In case of leaks, restrain discharge and consult manufacturer. In transportation emergencies, call 618 271-5835 collect.
Small unit capacitors are applied as a component of a large piece of equipment. Manufacturers utilizing askarel-filled capacitors should affix a label referencing this standard or describing disposal procedures consistent with it. 3.6.2 Large Units. Large capacitor units are defined as those which contain more than 2 pounds of askarel. The capacitor manufacturer should affix a label in a conspicuous place, referencing this standard or describing disposal procedures consistent with it. As a minimum, the label should contain information listed in 3.611.
s 5. Disposal of Laboratory Samples Containing PCBs. The disposal of laboratory sanples
and materials used for testing and experimental purposes which contain amounts of PCBs
(askarels) must be carefully controlled. Their disposition should be made in a manner
consistent with proper concern for the environment.
T
l.
.
5.1 Liquid Samples. Liquid laboratory wastes containing PCBs (askarels) should be
properly incinerated or disposed in sites suitable for toxic and hazardous liquids.
-Preference should be given to incineration.
5.2 Solid Samples. Laboratory solid wastes containing PCBs (askarels) should be
disposed in state approved toxic and hazardous waste disposal sites (See Appendix A) or,
if this is not feasible, in supervised dry landfill sites that meet all applicable state
requirements.
6. Spill Plans, Capacitors.
6.1 Capacitor Manufacturers Bulk Shipment Askarel Spill Plan. This plan is intended to
establish effective notification and action procedures, to guide the manufacturer of
polychlorinated biphenyls (Monsanto) and capacitor manufacturers in the event of a spill
while the material is in transit. A manufacturer using its own equipment and personnel
to transport PCBs should instruct its employees concerning proper procedures to be
followed in the event of a spill. Such instruction should be documented in each
DSW 324053 STLCOPCB4075384
manufacturer's spill control plan.
6.1.1 Spill Notification Procedure
1. Each tank car used to transport PCBs.from Monsanto to the manufacturer
should be marked boldly on its sides and ends, in 4" to 6" high letters,
with the instruction, "In Case of Spill Immediately Call 618/271-5835, collect".
2. Each capacitor manufacturer should provide to Monsanto the number of a
.
telephone which is manned 24 hours per day 7 days per week, which Monsanto
should call to inform the manufacturer of a spill. Where it is not
maintain
= number, the capacitor manufacturer should call
necessary, to provide notification of a
spill.
3. When Monsanto receives notification of a spill, its employee shall obtain
the following information:
. a) The name of the caller.
b) The official title and function of the caller
c) All available information concerning the spill, including:
1. Exact location (in sufficient detail to find the site on maps
and on the ground).
2. Time of occurrence (as close as possible)
3. Name of transportation company involved and its emergency call
number.
.`
4. Amount of material spilled, its current location, and action taken.
5. Cause of spill, if known
6. Condition of the transportation equipment.
'
7. Disposition of casualties, if any (what hospital, clinic or
physician).
8. Witnesses (name and address).
9. Information as to how to contact the . caller-or other responsible
party at or near the scene.
10. Identity of others who have been notified, including local, state
DSW 324054 STLCOPCB4075385
and federal pollution control agencies. Specifically name and phone number
of persons contacted.
4. After obtaining the information outlined in #3, Monsanto, acting as agent
for the capacitor manufacturer, should provide the following information to
the person reporting the spill: * a. Material is fire resistant.
b. It is recommended that boots and gloves of Neoprene of PVC be worn when
' handling the material, to avoid possible skin irritation.
c. Possible control procedures enumerated in Section 6.1.2. below.
5. Monsanto should then immediately notify the capacitor manufacturer that a spill of its material has occurred and should provide the manufacturer
with the information it has obtained concerning the spill.
6. The capacitor manufacturer, upon notification of a spill, should immediately
notify appropriate state and federal pollution control agencies and should
dispatch a responsible individual to the spill site immediately.
a. To notify the federal EPA, call 1-800-424-8802
'.
b. To notify state pollution agency if number is not known, call regional EPA
office to obtain state number. (See attached map and phone list.)
6.1.2 Spill Control, Clean-up, and Precautionary Procedures. The specific circumstances of'a spill should dictate effective control and clean-up procedures. The
following actions should be considered.
1. Possible control procedures: a. Limit the number of material that escapes from the container by righting
the container (tank car or drum), closing valves, plugging holes with
wooden pegs or by any other available means.
b. Limit spread of material by using absorbent materials such as dry sand, sawdust, oil absorbers or rags and/or by erecting an earthen .dam, using
any equipment available.
c. Prevent material from flowing into sanitary or storm sewers, ponds, lakes
DSW 324055
STLCOPCB4075386
or rivers by whatever means available. Do not wish material away
or into sanitary or storm sewers, ponds, lakes or rivers.
d. If other freight is contaminated, quarantine it until appropriate
. mode of disposition is determined. Such freight must be decontaminated
or disposed of in a responsible manner.
2. Possible clean-up and precautionary procedures:
a. Pump free askarel or liquid within contained area into drums or tank
truck. b. Dig up contaminated earth and transport to an area approved for the
disposal of askarels. c. Decontaminate any equipment used in the clean-up operation and dispose
of absorbent materials in a manner which prevents askarels from
entering the environment.
Note: Transportation equipment should be thoroughly cleaned before *
being used for other purposes. The cleaning of the equipment should
not result in contamination of sewers, streams, or other areas not '
approved for disposal of askarels.
d. If there are shallow wells in the surrounding area, sample the water
from the wells and analyze for .askarels.r; Be.'sure the water from a
contaminated well is not taken internally.
Environmental Protection Agency _______Regional Offices
Environmental Protection Agency Region I, Room 2303 John F. Kennedy Federal Building Boston, Massachusetts 02203 Tel: (617) 228-7265
Environmental Protection Agency Regional II, Room 909 26 Federal Plaza New York, New York 10007 Tel: (201) 548-8730
Environmental Protection Agency Region III Curtis Building, 6th & Walnut Streets Philadelphia, Pa. 19106 Tel: (215) 597-9898
Environmental Protection Agency Region IV 1421 Peachtree Street, N.E. Atlanta, Georgia 30909 Tel: C404) 528-5062
Environmental Protection Agency Region V 230 South Dearborn Street Chicago, Illinois 60604 Tel: (312) 896-7591
Environmental Protection Agency Region VI, Suite 1000 1600 Patterson Street Dallas, Texas 75201 Tel: (214) 749-3840
DSW 324056
STLCOPCB4075387
Environmental Protection Agency Region VL1
1735 Baltimore Avenue Kansas City, Missouri 64108 Tel: (816) 374-3778
Environmental Protection Agency
Region VIII, Suite 900
1860 Lincoln Street
Denver, Colorado 80208
'
Tel: (303) 837-3880
*
Environmental Protection Agency Region IX 100 California Street San Francisco, California 94111 ' Tel: (415) 556-6254
6.2 Capacitor Manufacturers Product Shipment Askarel Spill Plan. Shipping containers for
small capacitors (containing less than 2 pounds of askarel) and large capacitors should be
labeled in accordance with 3.6.
Spill notification, clean-up, and precautionary procedures should be in accordance with
6.1.2.
7. References
7.1 References to Text
(1) Standard Method of Test for Rapid Gas., Chromatographic Estimation of Higher Boiling
Homologues of Chlorinated Biphenyls for Capacitor Askarels, ASTM D3303-74.
(2) American National Standard Method of Test for Specific Gravity of Askarels,
. C59.68-1965 (R1973) (ASTM D 1810-63 (1973))
(3) American National Standard.Method of Test for Neutralization Number by Color-
Indicator Titration, Zll.131-1964 (R1974) (ASTM D 976-64 (1973), IP 139/65)
(4) American National Standard Method of Test for Neutralization Number by
Potentiometric Titration, Zll.59-1958 (R1971) (ASTM D664-58 (1968), IP. 177/64)
(5) Standard Method of Test for Density of Rubber Chemicals, ASTM D 1817-66 (1972)
(6) American National Standard Method of Test for Inorganic Chlorides in Askarels,
C59.55-1963 (R1973) (ASTM D 1821-63(1973))
(7) American National Standard Method of Test for Pour Point of Petroleum Oils, Zll.5-
1966 (R1972) (ASTM D 97-66 (1971), IP 15/67)
.
DSW 324057
STLCOPCB4075388
(8) American National Standard Method of Test for Power Factor and Dielectric Constant of Electrical Insulating Liquids, C59.22-1967 (R1973)(ASTM D 924-65 (1973))
(9) American National Standard Method of Test for Specific Resistance (Resistivity) of Electrical Insulating Liquids, C59.51-1965 (R1973) (ASTM D 1169-64 (1973))
(10) American National Standard Method of Test for Hydrolyzable Chlorine Compounds in Chlorinated Aromatic Hydrocarbons (Askarels), C59,106--1970 (ASTM D 1820-65 (1970))
(11) American National Standard Method of Test for Thermal Stability of Chlorinated Aromatic Hydrocarbons (Askarels), C59.Ill-1970 (ASTM D 1936-64 (1971))
(12) American National Standard Method of Test for Distillation of Road Tars,
A37.9-1974 (ASTM D20-72)
.
,
(13) American National Standard Methods of Testing Electrical Insulating Oils, C59.2-1974 (ASTM D 117-71 (1973))
(14) American National Standard Method of Test for Dielectric Breakdown Voltage of Insulating Liquids Using Disk Electrodes, C59.19-1968 (R1973) (ASTM D 877-67 (1971))
(15) American National Standard Method of Test for Flash and Fire Points by Cleveland Open Cup, Zll.6-1973 (ASTM D 92-74, IP 36/67)
(16) American National Standard Method of Test for Saybolt Viscosity, Zll.2-1956
(R1971) (ASTM D 88-56 (1973))
'
(17) American National Standard Method of Test for Coefficient of Thermal Expansion
of Electrical Insulating Liquids of Petroleum Origin, and Askarels, C59.57-1963 (1973) (ASTM D 1903-63 (1973))
(18) MUNCH, R.H. Measuring the dissipation factor, dielectric constant, and resistivity of liquids. Insulation/Circuits, vol 16, Mar 1970/pp 46-49.
.
(19) Chlorodiphenyls. Hygienic Guide Series. Westmont, N.J.rAmerican Industrial Hygiene Association, Jan-Feb 1965.
(20) Standard Specification for Chlorinated Aromatic Hydrocarbons (Askarels) for
Transformers, ASTM D 2283-73a
.
7.2 General References
m
Polychlorinated Biphenyls and the Environment, Interdepartmental Task Force on PCBs, Washington, D.C., May 1972. (National Technical Information Service, U.S. Dept, of Commerce, Springfield, Va. 22151.) (C0M-72-10419)
DRINKER, C. K. Further observations on the possible systemic toxicity of certain
of the chlorinated hydrocarbons. Journal of Industrial Hygiene and Toxicology,
vol 21, 1939, pp 155-159.
.
DRINKER, C.K.;^WARREN, M.F..; and BENNET, G.A. The problem of possible systemic effects from certain chlorinated hydrocarbons. Journal of Industrial Hygiene and Toxicology, vol 19, 1937, pp 283-311.
ELKINS, H.B. The Chemistry of Industrial Toxicology. New York: John Wiley fi Sons, Inc., 1959.
DSW 324058
STLCOPCB4075389
GREENBURG, L.;MAYERS,M.R.; and SMITH,A.R. The systemic effects resulting from exposure to certain chlorinated hydrocarbons. Journal of Industrial Hygiene and Toxicology, vol 21, 1939, pp 29-38.
Threshold Limit Values for Chemical Substances and Physical Agents in the Workroom . Environment. Cincinnati: American Conference of Governmental Industrial Hygienists,
1973.
TREON, J.F.;CLEVELAND,F.P.;CAPPEL,J.; and ATCHLEY,R.W. The toxicity of the vapors of Aroclor 1242 and Aroclor 1254. American Industrial Hygiene Association Quarterly, vol 17, 1956, pp 204-213. .
8. Revision of American National Standards Referred to in This Document ^ w/
When the American National Standards referred to in this document are supseded by a revision approved by the American National Standards Institute, Inc, the revision shall apply.
APPENDIXES '
(These Appendixes are not a part of American National Standard Guidelines
for Handling and Disposal of Capacitor- and Transformer-Grade Askarels
Containing Polychlorinated Biphenyls, C107.1-1974, but are included for
information purposes only.)
Appendix A
DISPOSAL SERVICES
In addition to the supervised dry landfill sites that may be used for the disposal
of askarel-containing scrap, the following additional known facilities and services
have been established. For other facilities, call your regional Environmental Protection
Agency office.
Chem-Trol Pollution Services, Inc. P.0. Box 200 1550 Baimer Road Model City, N.Y. 14107 Phone: 716 754-8231
This organization has facilities and services capable of handling:
(1) Liquids. Askarels alone or mixed with solvents or oils. Disposal by high-
temperature incineration.
(2) Solids (software) . Askarel-soaked compounds-, rags, cartons, absorbing earths,
etc. Disposal by incineration or scientific landfill.
(3) Solids (hardware). Capacitors, transformer tanks, cores, askarel-soaked metals.
Disposal by scientific landfill. Has solvent extraction capability.
Monsanto Company 800 North Lindbergh Boulevard St. Louis, Missouri 63166 Phone: 314 694-3352
.
This organization has facilities and services capable of handling askarel liquids alone or mixed with other oils or solvents by high-temperature incineration. Liquid is pumped through a gun with atomizing steam into incinerator. Temperatures are maintained at 2000F with auxiliary natural gas. Exit gases are quenched to 180F by contact with
DSNN M4059
/-
STLCOPCB4075390
water. Gas is then passed through a high-energy venturi scrubber for removal of particulates. Before exhausting to air (110oF)f gases are passed through a packed
column scrubber to remove HC1. Askarel liquids containing more them 1% water, or
any phosphate esters cannot be accepted.
'
Nuclear Engineering Company Eastern Division P.0. Box 146 Morehead, Ky 40351 Phone: 606 784-6611
"
*
,
Nuclear Engineering Company Disposal Division Sheffield, 111. 61361 Phone: 815 454-2624
This organization provides containerization, transportation, and disposal services of all liquids and solids (including hardware). Disposal is in controlled chemical and scientific landfill area. Licensed by Atomic Energy Commission for radioactive waste disposal. The organization also has two West Coast locations, in the states of California and Washington.
Rollins Environmental Services, P.0. Box 2349 Wilmington, Del. 19899 Phone: 320 658-8541
Inc.
-
This organization has facilities and services capable of handling:
(1) Liquids. Askarel alone or mixed with solvents or oils. Disposal is by
high-temperature incineration.
,
.
(2) Solids (software). Askarel-soaked compounds, rags, cartons, absorbing earths,
etc. Disposal is by incineration at combustion temperatures up to 2500F. Incineration
gases are scrubbed, and entrained solids are removed before exhausting to air.
Rollins Environmental Services maintains disposal facilities in the following areas:
Philadelphia/Camden: Rollins Environmental Services, Route 322 Logan Township Bridgeport, N.J. 08014
Inc.
*
_
Baton Rouge: Rollins Environmental Services, Inc. Scenic Highway & West Cheatham Lane Scotlandville East Baton Rouge Parish, La 70807
Houston:
,
' Rollins Environmental Services,
Tidal Road & Highway 134
Deer Park., Texas. 77536
Inc.
DSW 324060
STLCOPCB4075391
General Electric Company 100 Woodlawn Avenue Pittsfield, Mass. 01220 Phone: 413 494-3729
' .
This organization has facilities and services capable of handling askarel liquids and complete transformers only.
Appendix B
ANALYTICAL PROCEDURES AND LABORATORY SERVICE ORGANIZATIONS
Bl. General
Analysis for PCB in environmental samples is a tedious process due to the very low levels Cppb or ppt) which are of interest and due to the high sensitivity of the electron capture chromatographic procedure. It cannot be overemphasized that extreme care must be taken to ensure first that the sample is representative and second that sufficient numbers of blanks, and sample replicates are tested to define detectability limits and precision of the particular equipment and procedure being used. Cleanliness of sanpling devices and containers and their extraction is also important. Analytical procedures for the determination of PCBs in air, water and sediments are given in section B3.
'
B2. Laboratories
For a listing of laboratories offering services for PCB analysis refer to Directory of Testing Laboratories publication STP333A available from the American Society for Testing and Materials (ASTM) 1916 Race Street, Philadelphia, Pa..19103. If an outside laboratory is used, a verification of capability is recommended.
B3. Analytical Procedures
(See ASTM D3304-74, "Analysis of Environmental Materials for Polychlorinated
Biphenyls," reference.)
-
0^
STLCOPCB4075392