Document DDrpRNNr7RB6BkgO8BRyG11ka

W. B. Papageorge - World Headquarters September 27, 1972 H. Davidson Mr. S. Roehr Brussels In response to your telex request to J. H. Davidson for Infor mation about Monsanto'spolyohlorlnated biphenyl (PCB) Incinerator, the following Information may be of Interests 1. Capacity - Incinerators of this type are normally rated for a given heat release. The nominal capacity of the Monsanto Incinerator Is 1,250 lbs./hr. of Aroelor 1242. This corresponds to a heat release of 13H BUT/hr. 2. Feed Types - This Incinerator was designed for a full range of chlorinated and non-chlorlnated products. Still bottoms, solvents of various sorts, material containing lime--virtually any flowable material can be fed to this Incinerator. Because some of the feed material was to contain lime (up to 2j), the refractory had to be carefully chosen. The original refractory proved unsatisfactory. A high alumina (high cost) brick Is now being considered for replacement following an extended test period. PCBs caused leaching of Blllca from original brick and-thus caused premature failure. 3. For HC1 Oae Disposal - A scrubber system was Installed. A venturi Bcrubber Is used to assure wetting of parti culates. A packed column following the venturi is used to scrub out the HC1. 4. Oxidation Temperatures - This must be coupled with residence time in the oxldlser. Both are needed for complete PCB destruction. Higher chlorination levels require higher temperatures for destruction. The Monsanto Incinerator Is designed for 2,800<>F (for Aroelor 1260). Normal operating temperatures are In the range of 2,200-2,500F. Residence time is about 2.5 seconds. ...v 0065365 Mr. S. Roehr September 27, 1972 Page 2 5. Supplier of Equipment - John Zink Company, P, 0. Box 7388, Tulsa, Oklahoma 7^*105. Each Incinerator Is eus- tom designed. , \ I hope you find this Information useful. If I can be of further service please let me know. W. B. Papageorge At i f- 0065366 TOWOLDMONOQ55875