Document DDp494Y5r2Lkxo6xg5OQDGQw4
INSTRUCTIONS 488
AUXILIARY FEED BOOSTER PUMPS
UNITED STATES DESTROYERS DD692 CLASS
i
!
; BUILT IN 1943-'45
i
De Layal Steam Turbine Company
TRENTON, NEW JERSEY
September, 1944
Pumps Furnished by DE LAVAL STEAM TURBINE COMPANY, Trenton, N. J.
BUFFALO PUMPS, INC., Buffalo, N. Y.
The pumps furnished by Buffalo Pumps, Inc. conform in all respects to the design illustrated herein, and it should be understood that this instruction manual covers the equip ment of both pump manufacturers.
BPI-07.08-Hawaii 003690
ILLUSTRATIONS
. 1 Shop Photograph of Unit .............................................................. .... . . 2 Outline of Unit ..................................................... .... 3 Test Performance Curves - De Laval Units........................................ 4 Test Performance Curves - BuffaloUnits ........................................... 5 General Assembly of Pump..................... ....................................................... 6 Coupling.................................................... . . ........................ ....................... 0 7 Pump Bearing and Impeller Puller........................................................... 8 General Assembly of Motor .......................................................................... 9 Typical Motor Characteristic Curves ................................................
10 Motor Type Test Report................................................................................. 11 Outline and General Assembly ofMotor Controller...................... 12 Motor Controller Wiring Diagram ....................................................... 13 Controller Certification Data . .....................................................
Page 6 "8 "9 "10 " 12 " 14 " 16 " 18 " 21 " 22 "24 " 26 " 27
_l
BP!-07.08-Hawaii 003691
6.
BPI-07.08-Hawaii 003692
GENERAL
Composition and General Design
Two units were furnished for each ship. Each consists essentially of
P a size 2 1/S"/1 l/2"> vertical, single stage, single suction, centrifugal pump and a vertical, squirrel cage induction motor with a magnetic, acrossthe-line type controller. The motor is mounted on the upper end of the pump frame, and the pump and motor shafts are connected by an all-metal flexible coupling. Figs. 1 and 2 show the general assembly.
Ratings and Operating Data
Delivery, gpm ................................................... Suction Pressure, psig............................ Minimum Submergence, ft ........................ Maximum Submergence, ft ........................ Discharge Pressure, psig........................ Net Pressure, psi ...................................... Water Temperature, F................................. Speed, rpm..................................................... . Brake Horsepower........................................... Voltage .............................................................. Cycles................................................................... Phases.......................................................................
Condition A (Rated)
25 17.9
7 12 57.9 40 250 3500 1.94 440 60
3
Condition B
75 17.9
7 12 32.9 15 250 3500 2.36 440 60
3
Guarantee and Acceptance Tests
The power consumption of each unit is guaranteed not to exceed 1.8 kw when the unit is operated under the rated conditions. Acceptance test performances are shown by the characteristic curves in Figs. 3 and 4.
Drawings Supplied
Subject
t
/, , /? fj A
CT*} 6 / v
/
-
Factory No.
BuShins No.
Outline, Assembly, and List of Spare Parts and Tools ....
Test Performance Data ..... Pump Casing Details ................... . Shaft, Packing Box, and Miscel-
laneous Details ............................... Impeller, Coupling, and Miseel-
laneous Details ..................... . . Motor Bracket Details and Tools Motor Plan. ......................................... '. Controller Plan............................. .... Controller Certification Data
(DD692-791, 805-8.0.8)...................
Controller Certification Data (DD809-898) List of Spare Parts and Tool's................... .... .
DeL. 1! n
m
n it E.D. C.H.
M
G-10188 G-10193 G-10189
G-10190
G-10191 G-10192 D-38207 922-1-1M1
12, Sheets 1, 2, & 4
DD692-S4700-1 DD692-S4700-245414 DD692-S4700-8
DD632-S4700-3
DD692-S4700-4 DD692-S4700-5 DD692-S4700-300 94104-S6307-1657
DD692-S4602-283369
rr 922-14, Sheets
1& 2
DD829-S4692-280395
-7- V
BPI-07.08-Hawaii 003693
-8-
V
h
Fig. 2, Outline of Unit
i . j,
+
i
j BPI-07.08-Hawaii 003694
9* S ^
-9i
i ij
A
BPI-07.08-Hawaii 003695
F ig . 3 . T e s t P e rfo rm a n ce C urves - De L a v a l U n its
-10-
BPI-07.08-Hawaii 003696
F ig . 4. Test Perform ance Curves - B u ffa lo U n its .
-11-
Principal Weights
Element
Weight
Unit Complete................................................................................................... -....................... 451 lbs.
Pump......................................................................................................................................... 225
Pump Casing...................................................................................................................................112 ."
Pump Rotor ...........................................................................................................................
18 "
Motor Mounting Bracket..................................................................................... .... .
58 "
Motor......................................................................................................................................... 226 "
Motor Rotor...........................................................................................................................
23 "
Motor Controller.....................................
9"
PUMPS
General Description
The pumps are of overhung impeller construction with casings, bearing
supports, and rotating elements specially designed to minimize deflection.
Fig. 5 shows the pump assembly.
'
The pump casing is split vertically along the center1 line, the two sections thus formed being designated cover and case. Both the suction and discharge nozzles are located in the case section which makes it possible to remove the rotating element without the necessity for disturbing the main pipe connections.
The rotor is carried in two ball bearings which are housed in the bracket which forms the mounting for the motor.
Impeller Mounting
The impeller is bored for a light shrink fit on the shaft. It is key ed to the shaft and held against the shaft protecting sleeve by a lock nut which in turn is secured by a set screw.
A spanner wrench for the impeller lock nut was included among the special tools supplied. The threading of the nut is opposite to the direc tion in which the impeller normally rotates. '
Internal Seal
A labyrinth type seal ring is used to prevent excessive leakage from discharge to suction passages around the impeller inlet. The seal ring is
secured in the casing by a tongue and groove construction as illustrated in Fig. 5.
The seal ring clearance given in Fig. 5 is the normal or design clear
ance. This clearance will increase as the ring--wears, in service with conse
quent loss of pump efficiency, and,the best practice is to renew the. ring
when the wear progresses l!o the point where the normal radial clearance Is
doubled.
' . ''
Shaft Packing
Plastic metallic cotton case packing conforming to Navy Specification 33P25, Symbol 1433 is used to seal the casing at the point where the shaft
BPI-07.08-Hawaii 003697
s sasasssassEjssssssssssissssgssgstjssBsEssgsgsssssgses
-13-
emerges. The stuffing box contains six rings of packing and a lantern ring arranged as shown in Fig. 5 so that the lantern ring registers with a l/4" pipe tapped opening in the side of the stuffing box. The packing is 5/16" square in cross section, cut to fit a 1 l/4" shaft.
The packing gland is split vertically along the center line to facili tate removal, and the gland studs are so attached to the casing that they can be swung clear of the gland when the nuts are backed off slightly. The two sections of the gland are bolted together in accordance with Navy Speci fications to form in effect a solid ring for setting up the packing.
Packing should be installed so that the joints of abutting rings are staggered, and care should be taken not to set the gland up too tight. Ex cessive gland pressure on the packing causes scoring of the shaft protecting sleeve and rapid deterioration of the packing itself. Proper adjustment is indicated by a slight leakage of water from the gland.
Bearings
.
Each of the bearings consists of two single row, duplex mounted, angu lar type ball bearings installed with the wide faces of their outer races abutting as shown in Fig. 5. The upper bearing is mounted with the outer races.secured so that it locates the rotor axially, while the other bearing is free.to float axially in its housing.
Light press fits as defined in Appendix One, Navy Specification 42B5 are employed for mounting the bearings on the shaft. The bearings are se cured by a lock-nut which in turn is secured by a pronged lock washer all as illustrated in Fig. 5.
Grease which conforms to Navy Department Specification 14L3, Grade B, should be used as the bearing lubricant. Each bearing compartment is pro vided with a grease cup and a drain outlet which is fitted with a pipe plug. When the grease is renewed, the drain plugs should be removed and fresh grease should be injected through the grease cup until all of the old grease has been forced out through the drains. Then, before the drain plugs are replaced, the pump should be operated for a few minutes so that excess
grease can work its way out of the housing. In this connection, it should be noted that too much grease causes overheating.
Coupling
The pump rotor is connected to the motor shaft by an all-metal flex
ible coupling of the single engagement, gear type which is a product of the
John Waldron Corporation, Mew Brunswick, N. J.
Fig. 6 shows the coupling details. Taper fits are used for mounting the driving and driven members on their respective shafts, and the parts are secured by keys and lock-nuts. The latter in turn are secured by set-screws.
A high grade oil having the characteristics indicated by Navy Symbol 5190 should be used as the coupling lubricant. The coupling should be com
pletely filled with oil before the unit is started for the first time, and fresh oil should be added at regular intervals to insure an ample supply at all times. The oil hole plugs should always be replaced and tightened se curely after oil has been added.
At least twice a year, the coupling should be opened, cleaned, and re filled with fresh oil.
BPI-07.08-Hawaii 003699
1 Pump Shaft
s Hub
3 Lock-nut 4 Gaske.t
5 Plug 6 Ring Gear 7 Oil Seal 8 Drive Shaft
9 Key 10 Set-screw 11 Bolt IS Set-screw
13 Elastic 1 14 Lock-nut 15 Key 16 Hub Gear
Fig. 6. Coupling
Pump Case Vent
The suction compartment is provided with.a 1/2" flanged vent opening (see Fig. 2) which should he connected to the deaerating feed tank through a constantly rising pipe not less than 1/2" in size. The connection should be fitted with a stop valve.
Pump Case Drains
The stuffing box drip well has a 3/4" pipe tapped opening which should
be piped without a valve to the bilge or some other point of atmospheric
pressure.
,
A 1/2" drain outlet fitted with a pipe plug is provided at the lowest point in the casing for draining the pump.
Both of these drains are shown in Fig. 2.
Operation
Before the unit is started for the first time, it should be ascertain ed that the motor is wired for rotation in the direction indicated by the arrow on the bracket between the pump and the motor. Also, it should be ascertained that the ball bearings are adequately supplied with grease and
i I
^
BPI-07.Q8-Hawaii 003700
-15-
that the coupling contains sufficient oil.
The pump suction and vent valves should be opened before the unit is .
started. Never run. the pump dry.
.
Starting involves (1) starting the motor and (2) opening the pump discharge valve.
In service, the pump requires little attention other than an occasion-
al packing gland adjustment which should be made according to the directions
given under SHAFT PACKING.
'.
Securing the unit is simply a matter of closing the pump discharge valve, stopping the motor, and then closing the suction and vent valves.
To insure proper lubrication of the ball bearings, the bearing lubri cant should be completely renewed at least once every three months.
The unit should be kept clean at all times.
_
Disassembling and Assembling
The pump can be completely dismantled without the necessity for dis turbing the unit mounting, the main pipe connections, or the drive element. It is necessary, however, to break the vent connection before the cover can be taken off.
With the cover off, removal of the rotor involves simply taking off the ball bearing cap, unbolting the bearing housing end caver, taking out the coupling bolts, and withdrawing the rotor from the case.
The procedure to be followed in disassembling the rotor will be clear
ly apparent from a 'study of Fig. 5 and the foregoing descriptions of the parts which enter into the assembly.
In the reassembling process, the dismantling operations are reversed.
The ball bearings should be shrunk rather than pressed on the shaft.
In this connection, the best practice is to heat a bearing in a mineral oil
bath to a temperature approximating but not exceeding 200F., slip it over
the journal, and set it up by means of the lock-nut, tightening the latter
as the bearing cools. A new lock washer should always be used to secure the
lock-nut.
The shims (37-39, Fig. 5) between the bearing housing end cover and the housing proper should not be overlooked in the reassembling process. The total thickness of the shims should be such that a tight joint is formed between the end cover and the housing when the thrust bearing is clamped se curely against the locating shoulder in the bottom of the housing.
A .016" asbestos gasket is used for the joint between the case and the
cover.
Tools
,,
Ball Bearing and Impeller Puller - This tool and its applications are . shown in Fig. 7. One puller with two adapters (H-215K and H-215L) was fur- , nished with each ship group of units for the earlier ships of the class. On the later ships, only the adapter H-215L was provided by the pump manufac-.
turer. Standard pulling tools furnished by the Navy Department for theseu
' .
-
........
I
j j
j j
j i
BPI-07.08-Hawaii 008701
-16-
V ADAPTER H-2I5L
TYPICAL BEARING APPLICATION
ADAPTER H-2I5K
!
'i
y. ,
l*
l i's
Fig* 7, Pump Bearing and Impeller Puller BPI-07.08-Hawaii 008709
17-
ships are to be used as directed on De Laval plan G-10192, Buships No. DD69S-84700-5 in the removal of the bearings and impeller.
Miscellaneous Wrenches - This equipment is, listed below.
%
I
I
i
}
|\
I
Make and Type
Application
Quantity/Ship
De Laval #H~364B Spanner
Bearing Lock-nut (16, Fig. 5)
2
De Laval #K-364 Spanner
Impeller Lock-nut (33, Fig. 5) Coupling Lock-nuts (3 5c 14, Fig. 5)
2
l/8n Allen Set Screw Wrench
Lock-nut Set Screws (22 & 35, Fig. 5;
10 & 12, Fig. 5)
2
17
7/32" Allen Set Screw Wrench.
Coupling Oil Hole Plug (5, Fig. 6)
2.
Grease Gun Fitting - A standard type grease gun fitting threaded to fit the oiling holes in the motor-pump coupling and suitable for use with any gun having a push type nozzle was also furnished.
Spare Parts
Name or Description Rotor with Coupling Bearings Wearing Rings Throat Bushing Lantern Ring Coupling Bolts and Nuts Coupling Oil Seal
Part No. 13-39, 41, 48-50
18 50 30 36 11, 13 7
Deference
Fig. 5 n5 tt 5
-n 5 n5 n6 n6
Quantity/Ship 1 4 1 1 1 2 sets 2
Repair and Replacement Orders
The handling of repair and replacement orders at the factory will be greatly facilitated if the following directions are carefully observed.
Address orders to the manufacturer whose name appears on the nameplate of the unit for which parts are desired.
Give the serial number of the unit.
Designate the parts required by the part numbers appearing in the in struction book illustrations or the drawings supplied.
Identify the reference. If the instruction book is used, give the number of- the book and the number of the illustration from which each part number Is obtained. If a drawing is the reference, give the fac tory number of the drawing.
Specify plainly the number of parts desired.
Give complete shipping directions.
In returning parts to the factory, be sure that each part is tagged
with all Information necessary to complete identification.
,
i
BPl-07.08-Hawaii 003703
ft ft
VV AA
2O H2
UA _
SASAra^wPSPiPaiACAfcMwSA
Set> ftftp c
(0S0S0H,0r
j a) S S *V AC ..............+ A t(t. . to a A ao a a 6
liSSO
+3 P HHrlrlH
HiO'OvPHPH'PU'OO'OAVTPAl AeWP PAWiPii}
9(<4s ofl o> vi) ijHoHoa n n ti
tloo JhJWWKOOO
1 A <3 A
) OdO Od B
ft -H rl p n P At wdHh PCPCodddra OHOWOHd C A aotwco hhhliO, e e ah ppp
WApPHHOCOAAAVA -AH AA AA fQt fQt HA ctf H H H41
.IS .=...3..5..3.
AH AHHHoiHHoiHH(MPOAOnPOMPHnA)>
suouo
ao
wpoh-d p p p un a A H O
-Sofpfl-aaMoworaocobfAtiOJfttHPMhdC
>o w AMO
a4>aIicvladAA Aoh,H .tJAAMOOOO
chCsP fatqundHhOhhOHOHO id ^I^h-HH PP0 PO P0 +O3Q
> C 0 O d H d d d d d
^AdHOnQtftfflPtoPw+m3Pw+w3
dA A <5j
UMOU
33 33 hl3U3K A wftiifst S HJ Aw S 0AOh
(0 H A A
t_C___B__BbKoKoKsHdOfll&ooW
HKW'fWttlMDOlOH
F ig * 8* G e r^ rc i /s s e w M y o f K o to r
i
-19-
MOTORS
General Design
The assembly details of the motor and the stator winding diagram are shown in Fig. 8, along with stator coil winding data and data on insulation materials and treatments. The manufacturer's specifications follow.
(A) .Identification
.
Manufacturer - Electro-Dynamic works of the Electric Boat Company
Manufacturer's Type and Class - Totally Enclosed, AT-224
Navy Contract or Shipbuilder's Orders - See Electro-Dynamic Drawing
D-38207
-
Installed on - See Electro-Dynamic Drawing D-38207
Driven Auxiliary - Auxiliary Feed Booster Pump
Manufacturer of Driven Auxiliary - De Laval Steam Turbine Company,
Buffalo Pumps, Inc.
Reference Specifications - The motors described hereunder will con
form strictly with Navy Specifications 17M10 (INT) of the issue in
effect Sept. 1, 1940 Including Amendment #4 thereto.
Reference Drawings '
Title of Drawing
. Motor Assembly, Outline, and Specifications
Driven Auxiliary Controller
\ Manufacturer's Afo.
. BuShips No*
D-38207 G-10188 922-1-1M1
DD692-S4700-300 DD692-S4700-1 94104-S6307-1657
(B) Manufacturer's Descriptive Data
Motor Classifica. tion
>
Degree of Enclosure - Totally Enclosed Method of Cooling - Fan Cooled Speed Class - Constant Duty Classification - Continuous Voltage - 440 Frequency - 60 Cycles Number of Phases -.3 Type - KNQ - Squirrel Cage Ind. RPM (Syn) 3600 (FL) 3500
Torque Classification - Normal No. of Poles 2 Current Classification - Normal Starting Current Ambient Temp. - 50C Class of Insulation - A Temperature Rise - Table IV, Method #1 & #2 concurrently Mounting - Vertical Type of Electric Brake and Torque Rating - None
.
Motor Rating
Horsepower - 2.75
.
0.95 x (1.05 + n..^35
Formula HP -
------------------0.38
Load Limit HP - 2.75 (used; '
' S*48 ^ (not used)
Note: Above formula is based on characteristic curves of driven auxiliary shown on De Laval plan G-10193
BPI-07.08-Hawaii 003705
Performance (See Fig. 9)
Loads
Amperes
Efficiency
Power Factor
(A) Locked Rotor
(Starting Cond)
30
------
(B) Guaranteed 4/4
.
3.9
80$
(C) Guaranteed 3/4
3.21
77$
(d) Guaranteed 1/2
2.57
72$
(El Starting Torque - Not less than 175$ full load torque
(f) Pullout Torque - Not less than 300$ full load torque
47$ 87$ 82$ 73$
Weights
(A) Motor Complete - 226 lbs (B) Rotor Complete - 23 lbs ' (C) All Spares Boxed, including control spares - 88 lbs
. -
Shaft, Bearings and Lubrication -
(A) Shaft Material - Forged Steel 49-.S-2 (B) Type of Bearings - Ball (C) Ball Bearing Identification - Navy Type G, Class B, Grade 11
Manufacturer #7606 (D) Type of Lubrication - Grease, Navy Symbol 14-L-3b,. Grade B (e) Bearings are approved by ball bearing manufacturer as required'by
Par. 7(C), Appendix 1 of Navy Specification 42-B-5
Stator Core
(A) Inside Diameter - 5.125"
(B) Core Length
- 2 3/4"
(C) Air Gap
- .025"
Rotor Core
'
A) Outside Diameter - 5.075" '
B) Number of Bars - 49
_
! C) Material of Bars - Copper
'
D) Size of End Ring - 3/16" x 1 3/8"
E) Material of End Ring - Copper
F) Construction - Brazed
Exceptions to Navy Specifications - None
Preparation for the Initial Start
(C) The type test report is reproduced in Fig. 10.
1. Before starting the motor, measure the insulation resistance. The insulation resistance at normal operating temperatures should not be less than that given by the following formula:
Insulation Resistance (megohms) =
2. If the insulation resistance Is low, dry out the motor. Place the motor in an oven and bake at a temperature of approximately 80C to 90C until the insulation resistance becomes nearly constant. During this oper ation, remove the drain plug from motor bearing bracket. If motor cannot be removed, it should be covered with tarpaulin and dried by use of lamp bulbs or heating units.
j
!
Ii
i
BPI-07.08-Hawaii 003706
-21-
5. Make sure that the line voltage and frequency are correct (440 volts, 60 cycles) .
4. Check all connections with wiring diagram. Also check all con nections to controller with connection diagram shown inside controller cabinet.
5. See that rotor turns freely.
6. Operate motor for one hour before putting on load.
Troubles
Motor Fails to Start
Check the voltage at motor terminals. If there is no voltage at motor terminals, check the connections to the controller and the fuses in the con troller cabinet.
Check the motor insulation resistance for ground.
Check the resistance between phases for short circuited coil.
The motor may be overloaded. Disconnect the motor from'the pump and then start motor. Also see that rotor turns freely.
Heating
Check by thermometer the motor temperature and then check the temperature rise with that shown on the nameplate.
Measure the current in the three phases and compare with the nameplate data. If the current exceeds that shown on the name plate, the motor is overloaded.
The current in each of the three phases should be approxi mately the same value. Unequal currents will cause heating. -If current In any one of the three phases exceeds the nameplate value, check the terminal voltage. If the voltage in each phase is the same as is on the nameplate, check the stator resistance in each phase for short circuited coil.
See that there is nothing obstructing the entrance or exit of motor cooling air.
Check the room temperature.
Check the amount of grease in the bearings. Too much grease
Fig. 9. Typical Motor Characteristic Curves
BPI-07.08-Hawaii 003707
-22-
will cause heating of the bearings. Also make sure that the proper type of grease is being used (Navy Symbol 14-L-3b, Grade B) .
Check the alignment and air gap.
Operation at Wrong Speed Check the line voltage and frequency.
Check the load on motor. Overload will cause the motor to operate at a speed lower than that shown on the nameplate.
Check the rotor for loose connections or open circuit.
(C)TYPE TESTS
TO SC MAOC ONLY ON SELECTED MOTOBS REFER TO SPECIFICATION 17-M-IC
EFFECTIVENESS OF ENCLOSURE
SATISFACTORY_________________________________________
EFFICIENCY I SQUARED R LOSSES IN WINOINOS MARINO FRICTION AND WtNOAOE . CORE LOSSES
CAtCULATrO EFFICIENCY AT 0 LOAD. yi load. yi LOAD.
HEATING
MOTOR TORQUE
STATIONARY
VOLTS AMR* FT. 18. VOLTS
440 El. 2.
9
440
400 3 <50
320 280 240 200 (60 1 20
24.2 22.0
19. 6 16.0
13.7 11.6 9.6 6-8
5% aVr
3 78 I'/i
lt l va Va
PULL OUT AMPS FT. LBS.
19.7
IS.7
NORMAL LOAO HEAT RUN
tms
UNE VOLTS
JUooi
li
:oo
440 " ".
h
* 440
STATOR AMPERES
A6c
3.61 "
"
4-ii
3.60
1*1
* " 3-60
M3.61
*
" ** " 3.61
NO. l
TEMPERATURE fir THEHMOME TERS *
NO. i NO. S
NO,4 NO. > NO. 1 ROOM
TEMP. RISE DEGREES C WHILE RUNNINO TEMP RISE OLURCCSC AFTER SHUT-DOWN
14 15 12 29 13.5 IO. 29
LOCATION OF THE NUMBERED THERMOMETERS IN THE TABLE (NORMAL LOAD HEAT RON) ABOVE SHOULD BE INDICATED
NO. 1 CORE
No ? ft E. COIL NO. 1 Ft E. CPU- NO 4 ROTO* |0 * (? BRfr. NO. ft F. E. BRG.
ROWER FACTOR
FIELD AMPS 7b t OaD {SYN. MOTOR)
i/3 V 4 '4 */<
STATOR AMPERES ABC
2.53 2.87 3.61 4.24
2.31 2.85 3-60 4-23
8.32 8.86 3.61
4.24
R3CQBMCY WATTS
60 60 60 60
1338 1862
2442 3020
(INSPECTOR S sir,MflTURE^fcfr?
lOFFicevtwi^PrffliT Of /tWMJL.
1
l ro
CD;
J
POWER FACTOR
75.5
89.0 937
R.P.M.
3560 " 35J0
3eo 3500
/a&*C7V/Z
f/flf Amt date
Fig. 10 Motor Type Test Report
*'
;
^
i j
j I i .
BPI-07.08-Hawaii 003708
Vibration
Vibration may be caused by misalignment, worn bearings, sprung shaft, short circuited coil, unbalanced current, or vibrating foundation.
All causes for vibration should be checked before rotor balance weights are moved.
Insulation Failure
Insulation failure may be caused by oil or water soaked windings, ex cessive vibration, wrong voltage, or mechanical abrasion.
The high potential test for a repaired motor should be one half that of a new machine. (See paragraph 1 under "Preparation for the Initial Start".)
Maintenance
General
If the motor is not to be put in operation immediately, it should be stored in a clean and dry location. In order to give additional protection, the motor should be covered to prevent damage. It should be protected from low temperatures and sudden changes in temperature or humidity. If it is in a cold or damp location for any period of storage, the shaft should be re volved at least every two weeks so that the bearings will be protected dur ing the period of storage.
The interior and exterior of the machine should be kept clean. Dirt and grease must not be allowed to accumulate either inside or outside of the machine.
The drain plug in- the bottom of the motor should be removed at least
once a month. Also, the motor should be protected against sudden changes in
temperature which might cause condensation.
'
The insulation resistance should be checked at regular intervals in accordance with the Engineering Manual.
Care of Windings
The windings must be kept clean. Dirt and grease must not be allowed to accumulate.
If dirt and grease do accumulate, the windings should be cleaned with carbon tetrachloride.
If the insulation resistance is low, clean the windings and connec tions thoroughly. Then dry for several hours until the insulation resistance becomes constant. Coat the windings and adjacent parts with high grade, air drying varnish. Never apply varnish over damp or dirty parts. Do not depend on insulating varnish alone to increase the insulation resistance. Clean the parts and repair any defects first.
Disassembling and Assembling To Disassemble the motor: (1) Take out'all grease pipes and bearing temperature pipes. (2) Remove the nuts from the stator frame studs on the fan end.
BPI-07.08-Hawaii 003709
-24-
ENCLOSURE OUTLINE
1 Manual Contacts
S Operating and Overload Trip Mechanism 3 Mounting Plate
4 Enclosure 5 Name Plate 6 Controller Diagram
Fig. 11. Outline and General Assembly of Motor Controller
i
BPI-07.08-Hawaii 003710
-25-
(3) Draw off the fan cover and splash proof hood. (4) Loosen socket head set-screv/ In fan hub and remove fan. (5) Take out cap screws around bearing hub in both bearing housings. This
frees both inside bearing cartridges, (6) Remove fan end bearing housing. (7) Draw rotor out. (8) Draw out stator studs. (9) Remove drive end bearing housing.
To reassemble the motor, reverse the above procedure.
Spare Parts
Name or Description
Part No.
Refere nee
Ball Bearing. Felt Seals Stator Coil Slot and Winding Insulation
17 42-44 22 23-29
Fig. 8 "8 8 8
Notes All parts listed are classified *aboard spares*.
Quantitv/Ship
2 12 36 1 set
Repair Orders
Repair parts should be ordered according to the directions given on
page 17.
.
CONTROLLERS
General Design
The general design of the control equipment is shown in Fig. 11. Fig. 12 is the wiring diagram. Manufacturer's descriptive data and speci fications are given below.
A. Manufacturer - Cutler-Hammer, Inc.
B. The equipment is in accordance with Navy Department Specification 17C10.
C. Exceptions to Navy Department Specification 17C10 and referenced speci fications - 60 second max. reset time for overload mechanism in lieu of that specified in 17R6.
D. Descriptive Data of Controller
1. Enclosure - Dripproof 2. Rating - 440 volt, 7.5 HP, 3 phase, 60 cycles, size 1 3. Operation - Manual 4. Type - Across-the-line 5. Function - Motor Starting
BPI-07.08-Hawaii 003711
-26-
6. Duty - Continuous 7. Protection - Low Voltage Release Effect
Overload Protection - Emergency Run 8. Performanced - Mon-automatic 9. Service - A 10. Ambient - 40 Cor 50C
11. Insulation - Class A
.
E. Descriptive Data of Associated Equipment - None
F. Descriptive Data of Overload Mechanism
1. Type - Thermal (Solder Pot)
2. Compensation - Change in Rating does not exceed 5# for each
10C chance in ambient between 20C and 70C
3. Adjustability - Adjustable from 90# to 110# of relay rating
4. Type of Reset - Hand (from START button)
5. Resetting Time - 60 seconds or less when tripped at 150#
rating (40 C ambient)
6. Operating - Melting of metal in solder pot causes latch to
release contacts
.
7. Enclosed Rating of Coil - 6.21 amps.
8. Motor Rating - Minimum 5.17 amps, maximum 5.55 amps.
G. Weights - Controller 9 lbs. Spares (Unboxed) 1/4 lb.
'
'
Preparation for the Initial Start
Before the equipment is put in service for the first time, the cover of the controller should be removed and the wiring carefully checked to see that it is in agreement with the wiring diagram on the back of the cover. Also, the heater coils should be checked to make sure that they are properly centered about the thermal element.
When it has been definitely ascertained that the above details are correct, the cover can be replaced and the controller is ready for operation.
Operation
To start the motor, press the START button toggle mechanism to cause the contacts to close and connect the motor across the line. Pres ing the STOP button reverses the toggle mech anism action and stops the motor.
When an overload occurs, the overload mechanism will trip and cause the contacts to open. Resetting of the mechanism is inherent with pressing of the START button to restart the motor.
This operates through a'
FRONT LINE5 VIEW m
iii-1
For EMERGENCY RUN, hold down START button. This will maintain contacts closed regardless of overload conditions.
In the event of a voltage failure, the contacts will not drop out, and a return of power will cause the motor to start automa tically.
"M"
manually 0PERATE0 I M.Tn_ , THRU TOGGLE ^-----/PHASE
MECHANISM
Fig. 12. Motor Control ler Wiring Diagram
I T
.1. -4.
f |
I
|
| I I | j | | j; [ [ ;
'
BPI-07.08-Hawaii 003712
CO I
CO Q_ CO
/
F ig . 1 3 . C o n tro lle r C e rtific a tio n Data
-88-
Troubles
Contact Trouble
1. Overload - This results in excessive contact heating and short contact life. An overload condition can quickly be determined by placing an ammeter in the circuit.
2. Low Contact Pressure - This will result in excessive contact heating. To correct the condition, it is usually necessary to- replace springs which have lost their life due to overheating or flashing.
3. Loose Connections - This results in excessive heating of the connection.
4. Insulating Coating on Contact Surface - Dust, grease, or oxide will in sulate contact surfaces. This insulation is usually sufficient only to make the contacts overheat but not enough to prevent the device from closing the circuit. Dust and grease are easily wiped from contact sur faces; whereas operating the device a few times will clean up copper oxide which forms on the face of the contacts. Oxide will form regular ly on contacts that are operated too infrequently. Where such trouble occurs, it is usually best to replace copper contacts with silver con tacts .
5. Contact Welding - This condition can usually be traced to overheating, the common causes of which are enumerated in paragraphs 1-4.
Mechanical Trouble
1. Vibration - A rapid wear of parts will result from excessive vibration unless the controller is specifically designed to operate under such conditions. If it is not feasible to remove the controller from the area of vibration, vibration proof mountings should be provided for It.
2. Abrasive Dust - Abrasive dust in the controller will cause excessive
wear of the moving parts, and frequent inspections should be made to
guard against accumulations of this type. When found, they should be
removed immediately.
.
3. Over-Voltage - The life of a magnetic controller may be shortened con
siderably by overvoltage. The magnet of the controller will slam in
with great force under this- condition thus causing more rapid deterior
ation of the equipment.
'
Electrical Trouble
If there is voltage at the motor terminals, and the motor fails to starts look for trouble in the motor. But if there is no voltage at the motor, check the controller to see that all contacts are making. Be sure the distribution line is energized when checking voltage.
If contacts are burned or do not make properly, replace with new ones. Contacts will sometimes become burned from excessive currents on starting.
If overload relay trips only infrequently, the cause is probably due to an overload on the motor and the installation should be checked. If overload relay trips frequently, it can be due to one of the following causes and each one should be investigated:
1. Faulty or Overloaded Motor- This can be ascertained by placing an am meter in the circuit.
BPI-07.08-Hawaii 003714
-29-
2. Incorrect Size of Heater Coil - First inspect the heater coil; if found all right, compare the current rating of coil with that of the motor. The full load current of the motor should fall within the range of the heater coil.
The overload relay has an adjustment for percentage of full load cur rent. The overload will trip sooner at 90$ full load than it will at ' 100$ or 110$. Some adjustment of the heater coil according to the percent of full load current will often eliminate trouble due to tripping. The relay is compensated for change in ambient temperature and there is no necessity for taking that Into account when setting the overload in respect to trip ping time.
Maintenance
Inspection
Regularly scheduled inspections should be made of all control equip ment. These inspections will familiarize the operating personnel with the equipment and may prevent breakdown and serious shutdowns. The frequency of inspection depends upon a number of factors, but a trial will soon indicate the best schedule.
Cleaning
Dust that collects on the working parts of a controller should be re moved, preferably with a stream of compressed air. Dust, if allowed to remain on a controller, particularly if it is of an abrasive variety, may cause excessive 'wear of the moving parts.
Care of Contacts Contacts should be renewed before their "Wear Allowance" is compfttely gone. In case copper contacts become badly roughened or burned, they should be smoothed off with a fine file taking care to remove as little copper as necessary. Silver contacts should not be filed except in extreme cases of roughness. A silver contact, even though badly oxidized, will still make good contact.
Care of Insulation
The insulation on wires and coils will sometimes be damaged because of vibration or by rubbing against other parts. Parts with damaged insulation should be reinsulated as soon as the cause is discovered and, wherever possi ble the cause of the damage should be removed.
Disassembling and Assembling
To disassemble the controller, remove the cover and disconnect the power and motor leads after deenergizing the circuit. Then remove the screws holding the base to back of the enclosing case. When this is done, the complete assembly can be taken out. The assembly is made easily accesible for further maintenance. It is not necessary to remove the assembly to change or adjust the heater coils.
The dismantling procedure is reversed in the reassembling of the con troller.
BPI-07.08-Hawaii 003715
-30-
---
I
Spare Farts
J
The spare parts furnished for the controller are listed in Fig. 11.
;
' I Repair Orders
H
Repair parts should be ordered according to the directions given on
page 17.'
.'
$ 1
.
'
! :
.!
j
BPI-07.08-Hawaii 003716
MEMORANDA
i
BPI-07.08-Hawaii 003717
MEMORANDA
f I
BPI-07.08-Hawaii 003718
MEMORANDA
BPI-07.08-Hawaii 003719
MEMORANDA
BPI-07.08-Hawaii 003720
CONTENTS
GENERAL
Composition and General Design ................................................................................. Page 7
Ratings and Operating Data............................................................................................... " 7
Guarantee and AcceptanceTests ................................................................................
"7
Drawings Supplied...................................................................................................................... " 7
Principal Weights...................................................................................................................... " H
PUMPS
General Description................... Impeller Mounting........................ Internal Seal.................................. Shaft Packing.................................. Bearings . .................................. Coupling ........................................... Pump Case Vent........................ .... Pump Case Drains ........................ Operation........................................... Disassembling and Assembling Tools........................................... .... . Spare Parts....................................... Repair and Replacement Orders
Page 11 " 11 11 11 " 13 " 13 " 14 ii 14
'! 14 " 15 " 15
M 17 m 17
MOTORS
General Design ...................................... Preparation for the Initial Start Troubles .... ................................. Maintenance................................................
Page 19 " 20 21 " 23
i> CONTROLLERS
General Design ........................ .... Preparation for the Initial Start
Operation............................... ....
I Troubles ..................................................... Maintenance................................................
Page .25 " 26 " 26 27 " 28
BPI-07.08-Hawaii 003721
MEMORANDA
BPI-07.08-Hawaii 003722
Instructions 488
Brownell Photo Lithograph Co. Printers
BPI-07.08-Hawaii 003723