Document DDnXY7M6aK9o9QYmJRXjN8XX4
GUARDING EQUIPMENT IN SELECTED INDUSTRIES
Fig 26-46 The wedge-shoped lug on the washing tumbler door breaks the electric current at the storting switch contact when
the door is opened, thereby preventing normal operation of the tumbler The tumbler can be inclined or moved slowly for short intervals by pressure on the "inch" button.
reach them (Fig 26-47)
Press-type ttoners Presses should have
mechanical or electrical two-hand controls to keep the bands from between the head and the buck as pressure is applied Heated surfaces, especially on the front of the ironer, should be insulated
Ice Processing
Crushers The receiving hopper of small hand-operated ice crushers in which only small pieces are crushed should be about 5V4 ft from die floor so that the operator cannot reach the crushing rolls as he stands on the floor
For more positive protection, on both hand- and power-operated crushers, the sides of the hopper should be extended to such a height that the worker cannot reach the crushing rolls regardless of the posi tion of the machine, or the crusher should be enclosed on three sides, with an opening on the fourth side large enough to receive the ice
A chute leading to the opening is an effec tive means for feeding ice and at the same time prevents the worker from reaching the crushing rolls The crusher should never be placed so that a worker can fall into it
safety device on the door, an automatic steam or CO fire extinguishing device, a heat-actuated solvent dram, and an explo
sion release door
The drying tumbler should have a selfclosing explosion cover equal in area to at least 10 percent of the total area of the tumbler. It should have vapor vent pipes connected to exhaust fans and discharging at least 6 ft above the roof of the building and not less than 10 ft measured horizontal ly from any opening in adjacent buddings
Flat-work itoners Feed rolls should be equipjied with a movable barrier guard across the full width of the roll to stop the uoner should the operator's hand strike the guard, or with a fixed barrier that will pre vent entry of the hands into the rolls Pres sure rolls should be guarded so that the operator cannot reach into them Hot sur faces should be insulated if the operator can
Fig 26-47 If the operator's hands strike the hinged barrier that guards the ironer
rolls, the contact switch opens the circuit and the machine stops The barrier must be in place before the machine con be started by the operator.
26-33