! HAGER LABORATORIES, INC. 11234- E. Caley Avenue Englewood, Colorado 80111 (303) 79042727 (800) 282-1835 REPORT ON SERVICE NUMBER 28608IH October 26, 1987 To: Analysis: Caroline DeYong Southwestern Refinery Corpus Christi, Texas The following samples were submitted for analysis: Three membrane filter samples and two blanks for asbestos count. Method: ASBESTOS (count) The fiber content of each filter sample was analyzed following NIOSH procedure 7*100. Wedges from each filter were examined at 450 power using a phase contrast microscope. Fibers longer then five (5) microns with a length-to-width ratio of 3:1 or more were counted as asbestos. Results: The results are found on Table 1 and 2. Discussion: The present 0SHA permissible exposure limit (PEL) for asbestos is 0.2 fibers/cc. 1 LT( ) indicates "less than" with the lower limit of quantification shown in parentheses. Analysis for Chemicals Harmful to Mankind IB 000622 Page 2, SN 28608IH Southwestern Refinery October 26, 1987 Discussion (cont.) All samples have been corrected for the blank unless otherwise noted. Laboratory data are filed and available upon request. Hager Laboratories Inc. has been AIHA accredited since 1977. If you have any questions, please call customer service. Submitted by: 2a Maria Aleynikov Supervisor MA/sn it. IB 000625 3N 28608IH Dctober 26, 1987 TABLE 1 Sample Number 87-229 87-234 87-235 Blank Blank Counted Counted (fibers) (fields) Total (fibers) Air Volume Air Concentrat (liters) (fibers/cc) 113. 43. 20. 0. 2. 40. 100. 100. 100. 100.. 124000. 18800. 8760. LT(4380.) LT(4380.) 935. 853. 920. - - 0.13 0.02 0.01 - 1B 000623 SN 28608IH October 26, 1987 TABLE 2 1B 000624