Document DDMVJwZG43v57N4e3Zdq6k7wM
Z PLAINTIFF'S | EXHIBIT
m JMMC-1
SUMMARY OF ASBESTOS WASTE DISPOSAL OPERATIONS AT J-M SITES
I. Basis of Tabulation___ The summary information presented herewith merely represents some preliminary estimates based upon a limited amount of data currently available
: at GHQ. ' Plant responses to a simple survey questionaire have been, employed, without advantage of detailed explanations or clarification. Any common denominators in formulating these original responses probably are lacking. The compilations thus are a starting point only and should be merely treated as such.
II. Asbestos Waste Disposal at Multi-Division Locations (approximations)
Manville
Waukegan
Pipe Div. operations RPD operations with asbestos IPD operations with asbestos Building Systems Dept.
7,000 1,500
100 6> 400
6,800 1,500
200 1,500
Total 'tons of waste per year ; RPD (roofing trim, scrap, rejects)
15,000 13,000*
, *10,000
12 000
Contains some locked-in asbestos.
III. Annual Waste Disposal and Dump Capacities at J-M Sites
Annual Disposal Rate Disposal Site Longevity
Manville Waukegan Tilton Denison Green Cove Stockton
15.000 tons 10.000 tons
100 tons 3,000 tons
600 tons 22.000 tons
12 years 30 years 100 years
5 years 3 years 6 years
(to 1987) (to 2005) (to 2075) (to 1980) (to 1978)* (to 1981)
Plant reports additional on-premise site with potential 20 to 30 year longevity.
D 001588
section!
AMBIENT AIR CHARACTERISTICS AT ASBESTOS WASTE DISPOSAL SITES (Caution; Summary data not for use without additional detail)
IITRI Program; Denison Waste Disposal Site
02/27/74...wind from South at 20 mph; temp, about 60F 02/28/74...wind from South and SSE at 11 mph; temp, about 63F
2815 ft. upwind 2 meters high 7 meters high
1320 ft. downwind 2 meters high 7 meters high
2330 ft. downwind 2' meters high 7 meters high
fibers per cc with diameter of 0.5 um or more
Feb. 27/OM (500X)
Feb. 28/OM (500X)
.0171 .0195
. .0141 .0240
.0172 .0187
.0175 .0445
.0280 .0130
.0427 .0293
IITRI Program: Waukegan Waste Disposal Site
12/08/73-----wind from South and SW at 10 to 15 mph; temp, about 30F
1200 ft. upwind 2 meters high 7 meters high
near active face 2 meters high 7 meters high
1200 ft. downwind 2 meters high 7 meters high
fibers per cc with diameter of 0.5 um or more
__ _
December 8/OM (625X)
.000038 .000315
.000112 .000199
.000211 .000248
J-M/IH Program; Manville Waste Disposal Site
week of 08/13/75...wind continuously from NW at 10 mph or less
------------ . . 175 ft. upwind
lh meters high 220 ft. E tangent
lh meters high 120 ft. WSW tangent
lh meters high 1050 ft. SSW tangent
1 meter high* 200 ft. downwind
lh meters high 275 ft. downwind
lh meters high
fibers per cc rated within optical range
OM method (430X)
SEM techniques
................................... -i ,
.006
none
.010
.IS'* .0340
.011
.0292
.00024
no test
.010 .
.0196
.020
no test
1150 ft. downwind
'1 meter high*
.00069
*High volume air sampling units.
no test
D 001595