Document DDG4wRJxNLbGQwM774VKOVXaN

476 CHAPTER 33 1959 Guide COMBUSTION OF GASEOUS FUELS Gas burners employed in domestic heating appliances are generally of the non-luminous flame or Bunsen type. Part of the air required for combustion is inspirated as primary air into the burner miring tube where it mixes with gas, and then takes part in combustion at the burner ports. As the amount of primary air is seldom sufficient to support com plete combustion, additional air is supplied to the burner flames around the periphery of its ports. This secondary air is induced into the appliance and around the base of each separate burner flame by force of the issuing mixture of gas and primary air and by draft inspiration inherent in the heat of the flames. If a Bunsen type burner is properly ad justed, its flames will generally have a clear, blue appear ance. Yellow flames are indicative of insufficient primary air supply, and possibly of incomplete combustion. An ap preciable updraft is seldom, if ever, present even in flue- connected gas beating appliances, because most appliances of this kind are equipped with a draft hood which reduces the chimney draft at the appliance. It is important to note that gas furnaces and boilers, as well as meet other classes of heating equipment, are designed to create their own draft. The air-to-gas ratio in a Bunsen burner head has a de cided effect on the rate of flame propagation. The gas-air mixture must flow from the burner ports faster than the flame bums, otherwise flashback will occur. The flashback condition normally results either from an amount of primary air or insufficient gas or both. Conversely, the veloc ity of the issuing mixture must not be so high that the flame will be blown from the ports, a condition known as lifting. Fortunately, contemporary types of such burners have a rather wide range of flexibility in capacity and ad justment. In addition to this characteristic, gas supply is normally so uniform that if a gas heating appliance is prop erly adjusted when it is installed, its burners, with occa sional cleaning, should provide trouble-free service for years. When problems incident to changeover of the gas supply are involved, they are generally assumed by the local utility' providing the supply of gas. In many instances when.the gas supply is changed, it is necessary .to change the burn ers to these suitable to bum the new kind of gas. It should be recognised that a change in fuel gas will change the operating CO, value. For example, an appliance operating on carburetted water gas at 20 percent excess air will have 142 percent CO* in the flue gases. If a change is made to coke oven gas at the same gas input rate, with the excess air maintained at 20 percent, the operating CO* would drop to 92 percent. Luminous flame burners are occasionally used in central heating gas appliances. With these devices all air required for complete combustion is supplied to the flames as second ary air. Two fundamental advantages of this type of burner are that the possibilities of flashback are eliminated, and that a much higher gas velocity is needed to blow the flames off the ports. On the other hand, if there is any appreciable amount of flante impingement on any portion of the heating surface, or if secondary air is not effectively supplied to the flames, soot may be formed and also combustion may be incomplete. In some types of gas burners radiant baffles are used to convert part of the energy formed during the process of combustion to radiant heat. These baffles may also, serve to direct the flow of products of combustion along the heat absorbing surface. Gas-designed furnaces and boilers approved by the .Ameri can Gas Association are certified for operation at the rating shown on the nameplate. Considerations relating to safety, performance, and service life, require that such appliances be adjusted at inputs that do not exceed the nameplate in put rating. These appliances normally draw in from 20 to 50 percent excess air, depending on the type and general de sign. As has been indicated, some excess air is necessary to insure complete combustion at all times and also to pro vide a reasonable degree of flexibility in performance. Various types of appliances used for gas space heating purposes are described in Chapter 34. FUNDAMENTAL PRINCIPLES OF COMBUSTION Regardless of the type of fuel under consideration, its combustion results in the production of gaseous products. Many kinds of solid fuels contain minerals which cannot be burned and are therefore left as a residue commonly called ash. Moreover, unless sufficiently high temperatures are em ployed and an ample supply of oxygen properly distributed is present, the combustible constituents of solid, liquid, and even gaseous fuels cannot be completely burned. Incomplete or partial combustion of all fuels produces toxic gases, such as carbon monoxide, with smaller quantities of aldehydes, Anfbracfto Fuel 03 Flo* Ges Temperatora Shown, lost it Hated oa 65 F Room Temperotora Fig. 4 .... Flue-Gas Losses with Various Fuels* Fuels and Combustion ketones, and other bydroxylated hydrocarbon compounds. This fact indicates that, white combustion processes involv ing common types of fuel may be regulated by experienced operators to produoe the most efficient results, normal com bustion processes can be so unbalanced as to create hazards tmiftss both design and operation are planned with a knowl edge of the fundamental principles of combustion. Combustion may be defined as the chemical combination of a substance with oxygen resulting in the evolution of heat, and usually same light. The rate of combustion depends upon the rate of reaction of the substance with oxygen, upon the rate at which oxygen is supplied, and upon the tempera ture obtained due to surrounding conditions.' This is com bustion in its simplest form- All solid, as well as liquid and even gaseous fuels generally contain several combustible elements in combination with others which, depending on their nature, affect oxygen requirements and thus govern the combustion process. For a continuous reaction, as in heating processes, it is necessary to establish an effective balance between rates of removing heat and of supplying fuel and air or oxygen to keep the reaction going. In estab lishing such a balance, conrideration must be given to the removal or venting of products of combustion, so that the X co2 X EXCESS AIR IN FLUE GASES 477 entire process is one of flow wherein draft conditions in the combustion space are important. Complete combustion is obtained when all combustible dements in a fud are oxidized by all of the oxygen with which they will combine. All oxygen or air supplied is gen erally not utilized, and this excess portion is commonly referred to as excess oxygen or excess air. Excess air is usu ally expressed as a percentage of the air required for per fect combustion. Perfect combustion results when the exact amount of oxygen required for complete combustion of all dements of a fud is supplied and utilized. The percentage of carbon dioxide contained in the products of combustion from such a reaction is obviously the maximum attainable and is re ferred to as the ultimate CO, or maximum theoretical per centage of carbon dioxide. This condition of perfect com bustion, without having excess air or oxygen left from the reaction, is seldom, if ever, realized in practice. Most types of heating equipment must be sufficiently flexible in per formance to provide complete combustion with not only variations in the quality of a fud but also changes in the rate at which it is supplied. This situation makes it advis able, from a practical standpoint, to insure complete com- 2ZEXCESS AIR xco IN FLUE GASES 600 -- 500" --SO i r 40 - -30 - -25 400350' V. FLUE LOSS BUTANE AND PROPANE r X FLUE LOSS Adapted from Ammricoa Gas Association laboratories Fine las* Chart*. Fig. 5 .... Alignment Chart for Calculation of Rue Losses for Butane, Propane, Coke Oven, and.Naturdl Gases