Document DD8MDeBVdj0KXyo5B4nxZ0q0N

Minutes General feting Asbestos Textile Institute October 8, 1965 The INN, Buck ilill Falls, Pa. In Attendance: AMERICAN AS3ESTP3 TEXTILE CTRP. J.L. Rainey JNL. Christenbury D.F. r-uealy Vfei. Kaaskant K .11. Walter ASBESTOS CORPORATIOK LTD. G.F.A. Brink -E.L. Alexander (A.C.S. LTD.) BELL ASBESTOS MINES LTD. G.W. Smith F.P. Smith Wm.J.W. Smith R. Dodds-Hebron JOHNS-' iAIJVI LLE CORPORATION W.S. Hough E.A. Schuman W.C. Atkinson I Barnett C.L. Sheckler CADVJALADER, WICICERSIIAM & TAFT T.Jay Flocken (Legal Counsel) H-K. PORTER CQiTANY, INC. J.T. Griffis J.D. i cCluer D.2. Childers RAY3EJT03-I *Ai 3IATTAN IIJC. J.A. Brown, Jr* J.A. Bettes, Jr. L.C. Williams J.P. Wronslci J .vs/ Hawkins R.*. Smith TURNER & l'lEWALL LTD. Bernard Lincoln TURNER PROS.ASBESTOS CO. LTD. W.i-. Deckman BRITISil BELTING & ASBESTOS LTD. J.L. Mitchell UNITED STATES RUBBER COi-PAiJY S.J. Peele, Jr. A.C. Link D.T. Austin, Jr. ASBESTOS TE'-rriLE INSTITUTE - II.E. Sun bury (Exec. Secretary) ** GUESTS ** S.R. Zimmerman,Jr ,Exec.Vice President, Raybestos-Manhattan Inc. f .0. Scowcroft, District Sales jV.gr., Raybestos-Manhattan Inc. C.rf. Briggs, Control igr., Raybest os-Manhattan, Inc. -E.H. Wells, Vice Pres. & Genl. Mgr., Packing & Friction I:atIs. Div. - Johns-Manville Corp. Dr. J.W. Axelson, Research Chief, Asbestos Fiber Applications Johns-;.anvilie Corp. T-0. Nicoderms, Chairman, ASTi* Sc A-4 of D-13 J.L. Tucker,- Technical Consultant to A.T.I. N.L.A. Martucei, Products Manager, Garlock Inc. C.H. Sigler, .Director of Marketing, Tex^Div., United States Rubber Cc 5.N. Smith, Marketing Mgr.,General Textiles, United States Rubber Cc In addition to the above guests we were privileged to have twenty-5^* * -ladies accompany their husbands to our luncheon on Friday, Oct. 8th. Z PLAINTIFF'S EXHIBIT 4 GAR-29 J - I'inutes - General I meting - continued Page 2 ------------ I'inutes of the J'eeting--------------- President Brown called the meeting to order at 9:30 A.IT., and introduced the guests as listed above. 2. The minutes of the last meeting were presented for reading. On motion by J.A. Bettes, Jr.t seconded by I. Barnett it was voted to omit the reading of same. 3. The Financial Rerort was presented by E.A. Schuraan, Treasurer. Hr- Schuraan stated that the Institute's books for the year ending September 9th, 1965, had been examined by iir. W.E. Eddy, General Auditor of the Johns-i :anville Corporation, and found to be in order. On motion by S.J. Peele, Jr.f seconded by W.S. Hough, it was voted to accent the financial report, and it is made a part of these minutes. 4. President Brown introduced Dr. J.W. Axelson, Research Chief Asbestos Fiber Applications, Johns-Hanville Research Center, Manville U.J., Dr. Axelson presented a most excellent technical paper entitled ,TTesting of Asbestos Fibers - Discrete and Bulk Properties". By courtesy of Dr. Axelson and his company the full text of this paper is included with these minutes. Any correspondence concerning same should be addressed to Dr. Axelson at the Johns - j !anvi lie Research Center, I-anville, i/.J. 08835. President Brown expressed our sincere appreciation to Dr. Axelson for his fine paper. 5. The Fibre Producers Report was given by F, Parker Smith of the Bell .Asbestos l ines Limited. Hr. Smith, as usual, had some most interesting remarks about the current situation in respect to the 'production and sales of asbestos fiber of all grades. He mentioned that, judging from sales to August 31st, the total year now looks as if it might be about 5% below the year 1964, however, last year wss n record year. Textile fibers, tc August 31st, were down more than 5%. The wcrld market is fairly good at present, except for India and Japan. 6. The Legal Report usually Presented at this time by Mr. P-Jsy Flocken, our Legal Counsel, had to be omitted as the meeting was .running late due to the length of the technical paper by Dr. Axelson. A summary of the Counsel Report is attached to these minutes, by courtesy of i'x. Flocken,. . 7. President Brown stated that the Board of Governors at their raeet* ing last June had voted to award a Certificate of Appreciation to Mr. George F. Jenkins, who retired, as Senior Vice President of Asbestos Corporation Limited, Thetford ; ines, Quebec, on Hay 31st, 1965, to express our appreciation of his staunch support of the Institute over a period of many years, and his service as a member of our Fiber Testing Committee. As Ir. Jenkins -was on a trip and could not attend this meeting, the plaque was entrusted to the care cf Hr. G.F.A. Brink, for delivery to ;x. Jenkins. B. The Chairmen of our several working committees reviewed the imk cf their committees for the past year, and their reports are attained rir.ut es - General j Meeting - continued ) Page 3 to these minutes- All of these Chairmen are completing their terras, after serving two or more years, namely: L.C. Williams - Chairman: Air iiygiene u V.ig. Cn-~ittee J.hf,'Christenbury - Chairman: Sales Promotion Committee Ma* Jiaaskant - Chairman: Technical Committee . I* Barnett - Chairman: Fiber Testing Committee President Drown expressed to them the sincere appreciation of the' Hoard of Governors for their highly valued contribution to the advancement of the Institute during their term of office.' The new committee chairmen, who normally serve for a period of two years, are: Air Hygiene & Vfg. - W-C. Atkinson Tccitnical -- J.D. i'cCluer Sales Promotion - W.S. Ilough Fiber Testing - J.F. V/ronski 9. ?'x. I. Garnett reported on the progress of the 2nd Edition of the ''Kanual of Testing Procedures for Chrysotile Asbestos Fibre''. lie explained that the cony had been practically ready for the prints: but that some additional tests are now to be included, and some re typing is necessary to take care of last minute changes. Further, that the original cost estimate was too low in view of the inclusion of additional tests, and expenses of preparing the cony for the printer. He stated that the 2nd Edition, soon to be printed, would ' probably not be revised for at least five years, and asked that this be taken into consideration when final orders are placed with the Secretary of A-T.I. Those who have already placed orders oil the basis of the original cost estimate, will be contacted by the Secre tary and given the opportunity to revise their order in view of the 5 year period between editions, and the higher cost. 10. Mr. S.J. Peele, Jr., Chairman of the Nominating Committee, wbici consisted of J'essers VJ.S. Hough, L.C- Williams and himself, reported he had submitted a slate of officers to the Board of Governors at their meeting on October 7th, 1965, to serve the Institute for the coming year, and that the following had been duly elected: President - J-A- Brown, Jr. - Raybestos-Hanhattan, Inc. Vice President - J.b. Rainey - American Asbestos Textile Corp. Treasurer - E-A. Sc human - Jolms-j .anville Corporation Exec. Secretary - H.E. Sunbury . 11. President Grown announced that-the next meeting would be held on February 10th and 11th, 1966, at the Barbizon-Plaza liotel in New York City. . 12. The meeting then adjourned for luncheon, to which the wives had been invited, and it proved to be a most enjoyable affair. Respectfully submitted. t r3IL CLSMBNT SHAT/ J Yflth extreme sadness w report the sudden and unexpected death of Dr. ttyril C. Shaw, on the evening of November 12th, at his heme SF3 Gates Street, Philadelphia 28, Pa* He had recently observed his Jfuth birthday.Y.'hile the cause of death was a heart attack, he had never had any previous heart ailment. Dr. Shaw served the Asbestos Textile Institute well and faithfully frr a period of seventeen years, rendering to it an invaluable service. T.tien the Asbestos Textile Institute Fellowship was established at Rutgers University In 1946, Dr. Shaw was employed as a "Research Specialist" to work on projects of Interest to our members. In 1948 he was given. In addition to his work as Research Fellow, t ho responsibilities of -Executive Secretary and A.ssistanr Treasurer. In 1961 he was appointed iixecutive Director. During hi3 long association with the Institute he became widely known throughout the asbestos industry, both in this country and abroad, for his many technological contributions. Dr, Shaw resigned from the Asbestos Textile Institute in August of 1963 to accept the position of asbestos fiber specialist with the Certain-teed Corporation. At the time of his death he was Director of Research and Development for the American.Asbestos Textile Corporation, Norristown, Pa* A native of Columbus, Ohio, Dr. Shaw received his bachelor*a and master* 3 degrees from Pennsylvania State University,. and his ph.D In elevated temperature chemistry from Ohio State University. He was a member and Fellow of the American Ceramic Society, e reg istered Professional Ceramic Fngineer in the State of Ohio, a member of the American Society for Testing L Materials; American Trade Association; American Ordnance Association; and the American Standards Association. He was a member of the Roxbonnugh Baptist Church, and of the Masonic Order. Survivors Include hi3 wife, Mrs. Garnet Shaw; a daughter, Marilyn, who is a sophomore student at Marietta College; a son, Myril C.Jr. who is a fifth grade student at Penn Charter School; his mother, Mrs. Marian Shaw; and a"brother and three sisters. The funeral service was held on Tuesday, November 16th, at the J. Burton Corson Funeral Home in Philadelphia. The Asbestos Tsxtilo Institute was well represented at the service, and had the oppor tunity to extend to Mrs. Shaw and the children our deepest sym pathy on behalf of all our members. Interment was in West Laurel Hill Cemetery, Philadelphia,Pa. . November 20, 1965 H.jS. Sunbury Zxoc. Secretary . '. J ASBESTOS TEXTILE INSTITUTE a ^P-euurt of Funds September 9, 1955 Balance on Hand at Xast Report, May 10. 1965 General Fund Savings Fund Petty Cash Fund . . Receipts To Savings Fund (Interest) To General Fund (1965 dues) To General Fund (Book Sales/) . fc 2630.11 23114.01 96.54 209.13 500.00 56.26 Disbursements Total xm hand and received Legal Retainer (Six months finding 8/31) 1000.00 Legal travel 127.69 Telephone (4 months) 145.70 Meeting Expense (June) 534.43 ASTM membership dues 35.00 F.I.C.A. Tax 22.88 Secretary1s Salary (4 months) 363.75 Secretary^ travel 159.96 Office rent (4 months) 166.64 Technical Consultant (Test Manual) 225.26 Accountant (Caruso-year ending 8/31 300.00 Printing V. Office supplies Petty Cash vouchers ?-177-197 inclusive 56.01 86.10 Total Disbursements Balance nn Hand as of Sept.9f 1965 Funds General Fund (Eank Statement of 9/9/65) Savings Fund (Three Accounts) Petty Cash Fund Total Funds 2049.05 21323.14 10.44 Assets as of Sept.9, 1965 Cash in Bank (General .fund) . 2049.05 Cash in Eank (Savings Fund.) 21323.14 Petty Cash on Hand 10.44 Accts Receivable (Book sales). 6.34 Postage on hand - . 1.88 Furniture Z: Equipment (Nominal "Value) 1.00 Total Assets 2584 0.(56 765.39 26606.C5 5223,42 23582,63 23382.63 23391.85 "Liabilities ' (None) . Net V orth $23391.85 -t- $2000.00 transferred Xrmn Savings Fund to General Fund on 9/2/65 J> Respectfully submitted Asst. Treasurer / I 3tji.e:cit of gygisBL ?jet-ott Asbestos Textile Institute's counselt T^Jf.y Flocken, reports that the United States Supreme Court's decision it the United I'ine Workers of America v? Pennington Case S2C.TS to have taken labor unions out train under the piocective blanket thrown over then by Federal legislation in the labor management relations field in the l?3C?s. Counsel reviewed the background of this case and the Supreme Court's decision June 7, 1965, and stated that the essence of the decision is that: T' . . . a union forfeits its exemption from, the antitrust laws when it is clearly shown that it has agreed with one set of employers to impose a certain wage scale on other bargaining units*" Although unions seeking to negotiate uniform wages or working conditions throughout .an entire industry face new problems under the antitrust laws, the decision may also seriously affect bargaining tactics of employers. For when ever an antitrust case couid be ma.de out against a union under the Supreme Court's rule against an employer-union conspiracy to restrain trade, a similar case could be made out against the participating employer. It nov; seems clear that a commitment by a union not to grant more favorable conditions or terms to any com peting employer - a common form of collective bargaining agreement -- is illegal on its face. Unions can be expected to avoid any agreements with any employers as to what kind of agreements the union will negotiate with otier employers. The greatest hazard for unions who seek uniform labor standards -- and for the employers that deal with them -- lies in the threat of treble damage suits by disgruntled or marginal producers or by recalcitrant members of an employer association. There has been little indication since the Supreme - Court's decision last -June that a new unsettled period of industrial labor relations is about to begin. But while the unions, particularly the United i ine. Workers, appear to have been the principal losers in the Supreme Court, the increase in litigation involving unions and antitrust charges which seems likely to result from the Court's decision may show that workable collective bargaining has been the real loser. .dilutes: Air iyjlenc and wanufacturinG Cor.ittec October 7, 1965 The Inn Duel: Mil Palls, Pa. 9:30 A.,_ to 12 boon 9:00 P..- to 11:00 P..- Attending: .triers: I. C. ViIlia is, Cir.ir~.an U. C. Atldnson D. T. Austin, Jr. C. L. Shccllcr -i B Si dth :> I.'alter A. C. Lin.': itaybestos-.an-iattan, Inc. JoiinsvillO'.anvillc Corp. United States Rubber Jolms- anville Corp. daybestos-.anhattan, Inc. American Asbestos Textile United States lubber Absent: i*. P. oouveia T. C. IxCluskcy, Jr. 4. V. .clson '.A* Porter, Inc. railan-. rCluskcy Fabrics American S .citing f: aefininc Da onstration -- Bausch C: Lori, Rochester, I .Y. 14602 40-1 Dust Counter_______________ All riders attending* Bausch and Lai .icprcscntativcs - lr it. A. Scrzjer Product Ad'dnistratar Industrial Products Dept. r. Charles Tepo Technical 2njr. TIic industry' is always interested in new types of Autoi atic Dust Counters a3 they cone on the market. It is desirable to have a counter that could r.onitor conditions over a longer period of ti.no than our standard dust count ing procedure, and also to dir-inatc the possibility of human error. The 40-1 dust counter demonstrated by Bausch and Lamb rep resentatives operates on an optical oyster;. There aro input optics - photo:rultiplicr and lap, and output optics collector rirror and focus lens. There arc two stream of air supplied to the unit, X) a sample ctrca:: and 2) a filtered air sheath. This Gives accuracy to the unit. Slides were used to jive details on exactly how the unit . is built and operated. The unit contains a pu~p and by pass, 2 rufflcrs, input photo:xjter, 2 particle filters and odiaust. There are accessories available such as counter, alarm and strip chart recorder. The particular counter da castrated would only bo able to count partido3 up to one 211 lion per cubic foot. This would not be a satisfactory unit for our industry. Page 2 Tims, Bausch and Iamb has developed a new Proto-type 40-2 battery operated unit that will count particles Item 1/2 to 15 microns in size and up to 100 million particles per cubic foot. This unit trill be on test in the very near future. Ir. iU !/ kelson is to receive one of the proto type units and trill be reporting to our cimmitteo the results of the trials using this unit. For reference purposes the price of the 40-1 unit is 529S5 and the new 40-2 unit i3 v3300. The unit can be set to count any given particle size. If you uish to pick out certain particle sizes and count then, tho particle size indicator can be set, say for 2 micron setting, then a 4 micron setting and subtract. Tlie demonstration was very well accepted by all members and I an sure the followup interest on this unit will be very active in the future ATI meetings. Hearing Tests and Their Values Recently word was received that presently and in the future, loss of hearing will be compensable. The committee therefore reviewed the i^aico Audiogram Test Charts taken on new employees and mill employees. In all instances, except a few where persons knew they had loss of hearing, the critical speech area was not affected at all'or just slightly affected. Since records were not taken prior to this date, it cannot be stated as to whether or not this loss of hearing was caused by job or by natural loss of hearing or some other outside effect. It is a 3:nown fact that between the ages of 40 and 60 years there is a 15 dec ibel loss of hearing and this happens to most everyone. It is, therefore, very imports nt that industry take tests on people as they are hired. These tests should be done by a Doctor or a Registered kurse so we know that competently trained and experienced persons are doing the tests. One of the members supplied a paper on "mast Range Synposiun u3 Audiometry in Industry11. This paper will be revie*,red by members of the committee and discussed at the next meeting. Further, another member stated he '.rill supply their Industrial records on this particular subject at tho next Erecting. ` . International Conmress on AS3SST0SIS A brief review was made' of this International Congress report. Since portions of this are in French, vre have delayed any comments on its contents until interpretation is received. This may take quite a long time to accomplish. Therefore, we will bring it up at each meeting in the hopes that someone will have 6ome comments on its contents. -> ) * Page 3 Consultant - Industrial Hygiene Pro gran Committee has given careful consideration to the suggestion that the ATI retain a consultant for the Industrial Hygiene ftrogram.. After discussion, it was decided that with the available personnel that we have within the industry and the help of Dr* Leivis Cralley of the U. S. Public Health Service, it is not necessary at this time to have a consultant. Therefore, the committee considers this investigation complete. ' Method for Dcterirdne; Dust Concentration It had been recommended by the Committee that this method be placed in the new edition of the handbook. Committee will still recommend to the Sales Promotion that information on this handbook be made available to the consumer, either by including the entire method or stating that the "Method of Determining Dust Concentration" is available from the ATI upon request. The committee wants to restate that this is entirely tip to the Sales demotion committee, as to whether or not the handbook will contain reference to this method. With these minutes this item is considered complete. Machinery Exhibition - Ir.ternational-1965 The committee discussed equipment that was dieplajred at this exhibition which would be of interest to the Asbestos Textile Industry. In particular, we reviewed the ParksCramer frame and loom cleaning equipment which is a con tinuous cleaning unit, A Saco-Lowell chute feed t o cords and a VJhitin cotton plucker. Also, there was a Saco-Lowsll Rovanatic unit that operates very quietly in comparison to standard roving frames. This was of interest as ire are act ive on the noise abatement program. General Discussion The committee discussed safety programs, the practi cality of reworIcing fly waste, the effects of employee attitude on mill operation, . Review of Committee Activities for Past Year Meeting - October 6, 196A 1. Public Health Service Survey -- Dr. Lewie J, Cralley Dr. Cralley gave us a status report on the inplant environmental studies. At this time six (6) were com pleted and the next study was to be made at RaybestosKanhattan, Inc., Uanheim, Pa. The studies have gone v ell as reported by Dr. Cralley and participating companies. j . r Page 4 2. Biological -Iffeet3 of Asbestos - Oct. 19.20,21,1964 J.C. Tlie committeo suggested t!ie Board of Directors of ATI send a Public delations nan to this conference since Dr* Selilcoff is using the nc.js media for publications. 3* Quality Control Systems under UL~h-9C5o A. TIw conndttce reviev/ou t!iis specification and agreed it is well to be covered by this speo if you are doing Govern ment uor!c. A report from member companies indicates that all are cojvored by this spec. . Ijoctiny - February 11, 1965 1. Public hoalth Survey - Dr. Lerrls J Crallcrr Dr. Cralley reported on status of the studies and told us they will tahe appro:irately 25 years to acquire mean ingful data. Some plants have records for the past 15 years. In the future, there vdll be need for medical studies, --ore information id11 be available on this later. 2. -ieviery Current Publicity on The affect of Asbestos on Public Health_________ ____________ - The folia,ring articles uere revie-./ed and discussed: 1) - "Dangerous Dust" - Scientific American, December, 1964 - Volume 211. 2) - "Cancer Sbrperts Bye Asbestos in Alarm/Csncer Experts Bye Asbestos Perils", by Josephine .lobertson. The Plain Dealer, January 12, 1965, Cleveland, Ohio. Hcvieir and discussion of these articles hoeps members of the corn&ttoe up to date on the publicity Asbestos is receiving relative to Public Health. 3. Sur-nestion Systems Folla./ing are general procedures used by member companies. 1) - liourly employees participate. 2) - Separate participation for salaried employees. 3) - i-anageaent committee_ or .anageraent and Employee Committee, accept or reject suggestion. 4) - The value3 is accessed through complete investigation of the suggestion. 5) - The reuaru is either a fined amount or a percent of the first year's savings. Page 5 4. Variances - Production Control Variances in production control systems immediately point out the reduced or increased manufacturing costs to the management# lihen a change from standard is noted it is investigated and the cause checked# By this Lietbod a core accurate control can bo placed on costs or corrections Dade when necessary and the reason noted# 5# Portable Vacuum Cleaner Discussed several units currently available# .Several aember conpanies are expecting to evaluate these units# 6# hoisc Abatement Aeviawed the possibility of compensation cases coning up for loss of hearing. This program will be heut active in the future as several neenbers feel that in the future loss of hearing will be compensable kectlnr: - June 3, 1965 1# Public health Service Survey - Dr. Lends Cmll^y Dr# Cralley presented a paper prepared by Jeremiah 3# Lynch on "Asbestos Study - Procedures and Pindings"# This information uaa made available to all member companies for their review. lie also reported that 11 indications point to good dust control in Textile plants# He then distributed another paper entitled 'Relationship of Impinger Counts to Fibre Concentration by .Jenhrane Filters in Asbestos Textile Plantsn# Doth of these papers are drafts and -./hen they are finalized they will be published. 2# Portable Vacuum Cleaners 1# Tw'o units - l) Suction Apparatus and 2) Compressed Air Unit were tried. Doth units do a satisfactory cleaning of easy to read', areas but in equipment and close areas they aro not adequate. The committee has agreed to continue investigating vacuum cleaning equip ment as it comes on the market. he uill report their findings at time of test. 3. Direct Dust Counter Information lias been received that Dausch and lorib are developing a new dust counter light and photo electric cell to count all dust particles in the air. Three main factors * Page 6 make a unit such as this desirable: 1) -- Eliminate the human factor in counting* 2) - Take more readings in a shorter period of time. 3) - Cost of unit estimated at 33300. U Consultant Industrial Hygiene Procram A suggestion has been received to discuss and investigate the possibility of Asbestos Textile Manufacturers retaining a consultant to supervise a uniform Industrial Hygiene Pro gram and to conduct periodic surveys of plants. This suggestion has been taken under advisement and will be dis cussed in subsequent meetings. 5. Automatic Loom Cleaning Parks-Cramer have developed a new unit called Weave Cleaner-Travel Vac which has much higher velocity air cooperating vacuum. All members have received information on this unit and can follow up if they are interested in purchasing same. As outgoing Chairman of the Air Hygiene Committee, I wish to express my thanks and appreciation to the committee and members of other committees who have attended several of our meetings for being so cooperative in keeping the pro gram active and maldng each meeting a worthwhile and int eresting session. . I also want to express t he committee*s welcome and congratulations to It. Walter Atkinson, who will be our new Chairman for next year. Respectfully submitted, L. C. Williams, Chairman Air Hygiene L Kfg, Comm. ) KXTIUTES: _ * Asbestos Textile Institute Sales Promotion Committee The Inn, Buck Hill Falls, Pennsylvania October 7, 1965 ATTENDING: J.A. Brov/n Raybestos-Manhattan, Inc. J.A, Bettes, Jr. Raybestos-Manhattan, Inc. S.J. Peele, Jr. United States Rubber Co. W.S. Hough Johns-Manville Corp. E.A. Shuman Johns-Hanville Corp. J.T. Griffis H.K. Porter Co. J.L. Rainey American Asbestos Textile Corp. J.W. Christenbury American Asbestos Textile Corp. P.J. Floeken Cadualader, Uickersham & Taft K.L.A. Martucci, Guest, Garlock, Inc. 2. The Sales Promotion Coremittee attended a demonstration of Bausc & Lomb Dust Counting Equipment with the Air Hygiene and Manu facturing Committee. 2. Our large display Is not; located at Renssilaer Polytechnic Institute at Troy, Hew York. Earlier this year, it was viewed at the Royal Ontario Museum in Toronto, Canada.' 3. Continued work cn revising the A.T.I. Handbook was discussed. Additional assignments were made by Hr. E.A. Shuman, head of our sub-committee. - 4. We were brought up to date on the present status of Coast Guard requirements where fibreglas cloth is replacing asbestos to some extent. - 5 The continuing pressure of Japanese imports of asbestos cloth was discussed. 6. Hr. S.J. Feele agreed to continue to write his market report on asbestos textiles for the ASEESTOS magazine. Respectfully submitted, v 'V-- '-'' - /-*/ J. V. Christenbury, Chairman Sales Promotion Committee MINUTES: * Asbestos Textile Institute ' Technical Committee Beport Buck Hill Falls, Pennsylvania October 7j 1555 ATTENDING: J.D. McCluer W.M. Deckman J.W. Hawkins D.F. Quealy Wsa. llaaskant SUBJECTS DISCUSSED: H.K. Porter Co. Turner Bros. Asbestos Co. Ltd. Baybestos-Manhattan, Inc. American Asbestos Textile Corp. American Asbestos Textile Corp. 2- Specification SS-C-466e: The Official Interim Amendment-1 to Specification SS-C~466e - -was distributed. Specification SS-C-U66e is being revamped at the Bureau of Ships to include the various other asbestos textile specifications- Scheduled finished date - June 1966. 2. MIL-C-10316B: This specification will also be part of the new SS-C-46oe issue. In the meantime, attempts are being made, to have this specification amended for change in thickness. Note; Several requests were made by the writer to get an Interim Amendment "for the thickness only. We were informed ` by Mr. Abel, of Bureau of Ships, on 10-26-1965, that he had reached an agreement with the Army to issue an Interim Amend ment. As soon as this amendment is available, the writer will forward same to each Technical Committee Member. 3- A.T.I. HANDBOOK: The section under Asbestos Textile Products (pages 29 thru 32) was reviewed. The following recommendations for change were forwarded to Mr. J.W. Christenbury on October 19, 1965: 1- Page 30 - Grades - Footnote 1 - As referred to under this paragraph, pages 64 to 68 might be different In the new issue. 2. Elevated Temperature Serviceability - Page 30 - First sentence to be changed after 1500 F), "but also, in more recent applications, where temperatures in excess of 5000 F may be encountered", change into "also, in applications where temperatures in excess of 5000 F are encountered". 3. Page 31 - First line "400 to 800 change Into "400 F to 800 F". * 3- A.T.I. HANDBOOK: (CONTINUED) - -2- 4, A. Chart A - Identify this chart Just above the top .line, in center. . B. Include Grade AAAA - Strength retention 100# at 600 F and 800 F. 5* Page 32 - Third sentence "as an example recent studies show an erosion rate'1 change into "as an example, studies indicate an erosion rate, etc." 4. Chemical and Corrosion Tests: ' Above tests for asbestos lagging cloth were discussed. According to the KNOLL Atomic Laboratories in Schenectady, New York, the Lehigh Laboratories at Wilmington, Delaware is authorized to perform the tests required. Kay I thank all the Technical Committee Members for their support during ny tern as Chairman of the Technical Committee. Respectfully submitted W. Maaskant, Chairmen Technical Committee T %* HEajTES: ASBESTOS TEXTILE XESTHDTE FIBER TEST3WG CC-CIITTEE OCTOBER 7, 1965 The meeting vas held at the Inn, Buck Sill Falls, Pennsylvania. In attendance; G. F. A. Brink J. W. Axelson B. Lincoln D. E. Childers B. Dodds-Hebron J. Vronski I. Barnett J. L. Tucker Asbestos Corporation Ltd. Johns-Mcnvilie Corporation Turner and Hevail, Ltd. . E. K. Porter Company, Inc. Bell Asbestos Mines Ltd. Haybestos-Manhattan, Inc. Johns -Manville Corporation Technical Consultant, A. T. Subjects Discussed The first part of the meeting vas held Jointly with the Air Hygiene and Manufacturing Committee for a demonstration and discussion of the Bausch and Lonb electronic dust counter. At the conclusion of the discussion the members of the Fiber Testing Committee adjourned end regrouped for a discussion of the forthcoming "Manual of Testing Procedures." 1. Mr. Tucker reported on the printing cost quotation from tvo printers on the manual that vill contain about one-third more pages than the first edition. Individual test procedures vere also quoted upon. On the basis of a manual bound similar to the first edition the lowest quotation for 2500 copies vas $3200 and for 3000 copies $3^5 - For printing about 35 >000 extra pages of the procedures to be used for the requirements of individual tests the quotation vas $375. These costs do not include packaging and shipping. The final cost per copy vill also include the recovery of expenses for our Technical Consultant and typing of the proof copies. After the inclusion of one additional procedure submitted by QAMA and one revision, the lov bidder vill again be contacted for a revised quotation. "When this nev cost is known Mr. Sunbury vill request each member and affiliate to reviev original requirements on the basis that the next revision may not occur for about four to five years and also the reduced cost per copy vhen the total order is increased from 25OO to 3^00 copies. 2. Bauer-McITett Wet Classification procedure previously approved by QAMA vas officially approved for ATI. The revision allows the use of the nev Model 203-C Bauer-McITett Classifier. This vill be included in the nev manual. 2 3* A nev test for rapidly determining the "apparent surface area of fiber vas developed by Turner end Newall and adopted by QAMA on September lfc, 19^5- This vlll be Included in the manual as an additional procedure to the Dyckerhoff method. ATI and MFPB vill vote as soon as members have had an opportunity to study the procedure vhich has been circulated. k. Magnetic Eating procedure vill be published in the manual as currently revised, but the concensus is that more study is required to develop the desired improvements for future revision. 5- Seme of the members convened at a special meeting later in the day with Mr* P. 0. Nicodemus, Chairman of Sub-committee A-k of Committee D-13, ASTM to discuss tests required for the revised ASTM publication. Bespectfully submitted. Irvin Barnett, Chairman ATI Fiber Testing Committee > wJ TESTING OF ASBESTOS FIBERS DISCRETE AND BULK PROPERTIES - 'JOHN V. AXELSON JOHNS-MANVULE RESEARCH AND ENGINEERING CENTER MANVULE, NEW JERSET - Introduction Before beginning a discussion of the testing methods and equipment used for asbestos, I vant to briefly review a fev things about asbestos. Since chrysotile is by far the most common commercial type of asbestos, all of zny remarks vlll refer specifically to it although most will also apply to the other types. Chrysotile is a fibrous hydrated magnesium silicate which occurs in nature. Geologically, it was formed under hydrothermal conditions and occurs throughout the world including at least ^9 if not 50 of the states. It most commonly occurs in veins of various thicknesses in the serpentine host rock and is usually of the cross-vein type with the fibers perpendicular to the rock faces. The extraction of the fiber consists of raining the ore, crushing it, and removing and classifying the fiber. Since the thickness of the veins or the nominal fiber length will generally vary from about one inch down to submicroscopic sizes within a single piece of ore, it is very difficult to separate the product into any discrete sizes. Consequently, all milled fiber consists of fibers over a wide length spectrum and also includes some rock or granular substance. But that is not all. The fibers are also present in the milled product in clusters or bundles varying in size from the single fiber with a diameter of about 160 to 200 Angstroms to a bundle one quarter inch in cross section containing millions of individual fibers. Eov are these tested? I must admit "that some of the methods are crude, some have been developed to help predict the -use of the fiber In specific products, and some are very difficult. However, ve do find these tests useful and ve ore always looking for new and Improved tests which will characterize asbestos more specifically First, I will review the more common tests that have been made to determine specific physical properties of asbestos. ) -3- Msasurement of Discrete Properties Tensile Strength . .. . Tensile tests are made by the classical method of fastening a specimen between two Jaws, one movable, and applying a tensile stress to the specimen until It fractures. The difficult part is to obtain the specimen and to mount it properly- The common technique is to have someone with good eyesight extract a bundle of fiber which is Just visible, or in other words, is less than the diameter of a hair- Since the bundle is about 0.001 inches in diameter, it contains up to about a million fibers. Hopefully, these are all continuous fibers and the strength of the bundle represents the strength of the individual fibers. The length of the fiber specimen will depend on the sample but should be in the range of l/2 to 1 inch. Uext, the cross-section has to be measured. This is done microscopically and assumes that the bundle is cf circular cross-section and a solid mass of asbestos. There are several different methods for mounting the specimen. Our technique consists of first coating the top support wire of the tensile testing unit, Figure 1, with sealing wax and touching the fiber specimen against this while the wax is still soft. After cooling, the top support wire with attached sample is suspended from the top arm and the height of-the bottom support wire is adjusted to the length of the specimen which is then attached to the bottom wire with a gob of molten wax. The testing machine is started to provide a tensile pull on the specimen until fracture occurs. At this time, the maximum load at break is recorded and the tensile strength is calculated from this load and the measured cross-section. Because of the heterogeneous nature of the fiber, it is very difficult to obtain good results. Values believed to be -2^ closer to the true tensile strength of asbestos are obtained vfaen a sharp break is observed, as contrasted to a ragged break vhere sections are breaking or being pulled apart. Fibers tested are in the range of 25 microns or 0.001 inches and show breaking loads in the range of 100 grams. The measurement of elongation during the application of a tensile load to a fiber will allow the elastic modulus to be calculated. However, this elonga tion or strain is very small and therefore very difficult to -measure on these small fibers. One method is to use a cathetoraeter or measuring microscope which will measure the change in fiber length with load. In another method we used a laboratory balance with the load applied by releasing water in a container on one arm of the balance through a calibrated orifice so a counterweight on the other pan will apply a load to the fiber which is fastened between the first balance arm and the base of the balance. By extending the swing indicator on the bal ance, it was possible to obtain a 7:1 advantage and measure the strain by ob serving the movement of the swing arm. Total strains up to about 2^ were measured for chrysotile asbestos as compared to l or less for the more brittle amosite and crocidolite fibers. Typical values for tensile strength and modulus of a number of types of asbestos are shown in Table 1. Fiber Chrysotile Crocldolite Amosite TABLE I. PHYSICAL PROPERTIES OF ASBESTOS Average Tensile Strength, psl 281.000 to 436,000 469.000 to 605,000 148.000 to 203,000 Modulus of Elasticity, psl 23.2 x 106 27.1 x ID6 23.6 x 106 From "Asbestos Reinforced Plastic Pipe", R. E. Cryor, Chemical Engineering, pp 134, August 2, 1965 Density^) Since asbestos is a fibrous material vith the fibrils associated in groups or bundles, special precautions must be used for determining the density. Basic-, ally, this consists of evaluation of the sample in a pycnometer. After complete degassing,' a standard pycnometer density Is determined from the knovn values for the veight of the asbestos, the veight of the asbestos plus the fluid in the pycnometer, the volume of the pycnometer and the density of the fluid. A number of determinations for Canadian chrysotile gave values ranging from 2.53 to 2-56 gms/cc vith an average value of 2.56 gms/cc. ' Coefficient of Thermal Expansion. . This is a very difficult measurement vith asbestos since a sample conducive to linear measurements Is almost impossible to obtain. The technique,used has been one in vhich the difference in density vith temperature has been measured for a sample of asbestos and the coefficient of cubical expansion calculated from It -6- ) Both the pycnometer and volumenometer vere investigated hut the pycnometer gave very erratic results that vere believed to be caused by the loss of some of the fine asbestos vith the fluid vhich is lost on expansion. By careful drying of the asbestos and degassing after immersion in the fluid, reasonable ' results vere obtained vith the volumenometer vhich uses the Archimedes principle that the decrease in veight of a sample immersed in a fluid is equal to the veight of the displaced fluid and the volume of this fluid is equal to the volume of the solid. Tests vere run using an asbestos float sample vith -weighings at O.JC and 99.2C. Measured densities vere 2.629 and 2.605 gms/ml. It can readily be shovn that the coefficient of cubical expansion is related to density by the following equation: B * do-dt * 2.629-2.605 - 0.00008 in3/in3/oc dSt (2.fc05)(9i3.5j" or B = 8x10"5 5x10-5 in3/in3/p. 175" These values coincide vith those for an aluminum alloy. Vith anisotropic materials the linear coefficient of expansion is approximately l/3 of the cubical coefficient but this probably does not hold for a fibrous material like asbestos. .Although measurements of this type are made on a bulk sample, the technique at least theoretically gives a value vhich is discrete for an asbestos fiber. Specific Heat I vill not dvell on this subject, but only state that the specific heat for o -7- ) chrysotile asbestos has been measured by standard calorimetric techniques and a value of 0.25 Btu/lb/F has been determined. There may be small differences for different grades of asbestos from different deposits but they are probably not significant. Refractive Index Refractive index is defined as the ratio of the velocity of light in a medium compared to its velocity in air. One of the easier vays to measure this property is to use liquids of knovn refractive indices. A small sample of asbestos is dispersed in liquids of varying indices on a glass slide. These are observed under a microscope. The refractive index of the chrysotile is taken as that of the liquid in vhich the fiber is least discernible. For chrysotile the refractive index is in the range of 1.50 to 1.55 depending' primarily on the source of the fiber. This compares to a refractive index of about 2.5 for titania, 2.0 for zinc oxide, and 1*33 for vater. Measurement of Bulk Properties A number of tests have been devised to measure the bulk properties of as bestos. A group of these have been standardized and the test methods-published by the combined efforts of the Quebec Asbestos Mining Association, the Asbestos Textile Institute, and "the" Mineral Fiber Products Bureau (formerly the Asbestos- Cement Products Association). The publication is entitled "Manual of Testing Procedures for Chrysotile Asbestos Fibre" and copies can be obtained from the Q.A.M.A. Testing Laboratory, Sherbrooke University, Sherbrooke, Quebec, Canada. It is hoped that the tests in this manual vill serve as the basis for test- procedures for asbestos that vill be promulgated by ASTM. - u . -8- One of the most difficult parts in the testing of asbestos is to obtain a representative sample. Specific instructions are given in this manual for proper sampling of a shipment of asbestos in order to obtain a representative sample. Even if these are followed explicitly, there are difficulties^ and variations vithin a lot are not detected. All I vish to state here is that the sample used for testing should be the best sample obtainable for the purpose and that special care should be taken to eliminate loss from any fraction of "the sample. The test results should be reviewed in the light of the sample used and extrapolated con clusions should not be made. Dry Screening The Quebec Standard Asbestos Test . This is a test used to classify asbestos fiber into the commercial grades that have been established by the QAMA.* It is a dry screen test which serves the stated purpose but leaves much to be desired in classifying the utility of a fiber for specific uses. . The test utilizes a series of nested box screens. Figure 2, constructed of A"cast aluminum and measuring 1^-3 x 2k^n x 3i" (approx.). Specific openings and wire dimensions are given for each screen to provide nominal 4 mesh, and 10 mesh screens. A pan and cover complete the screen assembly with the J-in. screen directly under the cover and the 10 mesh screen above the pan. The screen assembly Is fastened to a gyratory mechanism that rotates at 327 rpra. A one-pound sample of asbestos is used in this test. All clots and lumps should be broken up and the moisture content should be less than 3$- (Canadian chrysotile under atmospheric conditions will contain 1.5 to 2$ absorbed water). .-9- ) The fiber Is allowed to fall loosely onto the top screen and the cover Is closed without compressing the fiber. The machine is started and runs for 600 revolutions when it automatically stops. The fiber remaining on each screen is removed, weighed and recorded in tenths of an ounce. The amount on the top screen determines the grade of the fiber. Standards for a few grades of fiber are given in Table 2. TABLE 2 LENGTH CLASSIFICATION OF ASBESTOS Grade No. 1 Crude No. 2 Crude Length or Distribution by Screen Size Basically crude 3/4" and longer Basically crude 3/8" to 3A" 1/2" Quebec Screen Analysis, oz. 4 Mesh .10 Mesh Pan 3K 7.0 7-0 1-5 0.5 3T 2.0 8.0 4.0 2.0 4d - 0.0 7-0 ' 6.0 3.0 4t 0.0 2.0 10.0 4.0 5D , 0.0 . 0.5 10.5 5-0 5R 0.0 0.0 10.0 6.0 6d -0.0 0.0 7.0 9.0 7D 0.0 0.0 5.0 n.o 7R 0.0 0.0 0.0 16.0 It should be pointed out that the classification in Table 2 applies only to asbestos out of Quebec. Other areas of the world, including other provinces of Canada, use different designations and equivalency of grades has to be determined. -10- In addition to the number-letter designation/ most Quebec producers use a third number identification vhich tells hov that particular grade vas produced. It denotes vhat part of the mill the fiber came from and vhat processing it has undergone. For Johns-Manville asbestos, this third number roughly signifies -the degree of openness of a fiber. * IRo-Tap Test Ibis is the standard test used by all industries dealing vith particulate material. The testing unit is the W. S. Tyler Ro-Tap Testing Sieve Shaker, Figure 3, and consists of a series of 8-in. diameter screens vhich are nested together and shaken at a rate of 285 rpm vhile simultaneously having a tapper .strike the set 15k times per minute. In operation, the screens are nested vith a pan on the bottom and successive screens vith larger openings stacked above this, and finally a cover on the top screen vhich has the largest opening. The mesh sizes of the screens vill vary vith the grade of fiber being tested but vill range between a 3 mesh and a 65 mesh. The sample size is 50 grams for grades k and 5 and 100 grams for grades 6 and belov. The time also varies from 10 minutes for all grades JD and above to 30 minutes for those belov 7D* In some cases the procedure is varied by using a different-sized sample or changing the time or screen sizes; another innovation is to separate the fiber and .granular portion on each screen by shaking to stratify each portion and then care fully aspirating the fiber off and veighing the remaining granular material. The utility of this test to characterize a fiber for Its usefulness is questionable but it can be effectively used as a control test to ensure that a specific grade of fiber maintains certain size characteristics. It is particularly useful vith the shorter grades. "Vet Screening Tests Bauer-McNett . ... The Bauer-McNett Wet Classification Test is the most common vet screening test and vet screening is the most effective, practical method known, to obtain l length distribution measurement of fibrous materials of heterogeneous length. The vet technique tends to separate the particles so each one is classified by itself rather than as a component of one or more other particles -which are ag glomerated together. The Bauer-McNett unit, Figure k, consists of a number of elliptical tanks with a removable screen on one side. The tanks are mounted in a cascade so the overflow of one vill flov into the next. Each tank also contains a baffle plate parallel to the screen and about three quarters of an inch avay and a bladed cyl- ~ indrical rotor at one end -which runs at 5^ rpm. The purpose.of these tvo modifications is to orient the fibers parallel to the screen surface and to minimize endwise flov of fiber through the screens. There is an outlet on the bottom of each tank which is closed with a plug, but which is also connected to a vacuum system through a special cup. This cup has a screen which supports a filter paper and acts to collect the material from each tank at the conclusion of the test. In operation, all of the tanks are filled with water and a standard flow Df water through the tanks is established at 3 gpa. The rotors are started'and . -the sample is placed in the uppermost tank. During the running of the test, it is necessary to periodically brush off the material from the screens so blocking does not occur. After running for the prescribed time, the water flov and rotors are stopped and the plugs at the bottom of the tank are removed. The water drains out of each tank through the filter paper which collects all of the liber remaining O -12- J In that tank. The Interior of the tank is thoroughly vashed to remove all fiber and transfer It to the filter paper. The papers vith their fiber are dried and weighed `and the percentage cf fiber from each tank is calculated. . Most Bauer-McNett systems consist of four tanks and therefore four screens, but five size fractions are obtained since the material going through the last - screen to the drain is measured as the difference between the weight of the original sample and the sum of the veights from the four tanks. As -with dry screening, the screen sizes, sample size and time of test vary vith the grade. The screen sizes used are generally k, lU, 35, and 200 mesh, but a 100 mesh is sometimes added vith the k mesh removed and a 325 mesh may used as the last screen. Sample sizes are 10 grams through grade 7D and 20 grams for shorter grades, and the time of test is 20 minutes except for the float grades vhich use 30 minutes. Clark Classifier This test also consists of flowing water through a series of screens such as in the Bauer-McNett test. The unit, as shown in Figure 5> consists of a semicylindrical tank with four rotating, circular, perforated discs or screens dividing the tank into four compartments. A 5-gram sample of fiber is placed in the first compartment vith the discs rotating at 2f8 rpm and the vater flow set at 12.5 liters per minute. After 6^ or 20 minutes depending on the grade of fiber, the vater flow is stopped and the vater from each compartment is drained through a filter paper in a drain cup as vith the Bauer-McNett. For fiber grades above IfA, the disc openings are l/2, l/k, and l/8 inch and 30 mesh. A 100 mesh screen is used vith the l/2 inch opening disc removed for shorter grades. In some cases the fiber length for each fraction is not designated by the screen or plate opening, but rather the average length of each fraction is calculated from a microscopic measurement of 50 representative fibers. These average lengths and veights of. o 13- each Traction are then used to calculate an average length of filer for the sample on a dust-free (minus 100 mesh) basis. Surface Area Air Permeability The determination of surface area by air permeability is based on the flow of fluids through porous beds. The rate of flov or the pressure drop across the bed is related to the size and length of the flov channels. These in turn arc related to the size of the particles in the bed and this particle size determines the surface area. It should be noted that the area measured is only the external area exposed to the flov and does not include areas that are dead air spaces. In order for these relationships to hold, it is imperative that the porosity of the bed be essentially constant. With granular materials, this can be done only by screening into fractions and testing each one, hut vith compressible materials like asbestos fibers it only requires that a standard veight be compressed to a fixed volume. . , All air permeability methods use the technique of floving air through the porous bed. Hovever, some types measure the pressure drop at a constant flov rate; others measure the volume of flov at a constant pressure; and other6 measure the time for a knovn volume of flov. The Dyckerhoff unit, shovn in Figure 6, is the most videly used in the asbestos industry and is based on this last principle. A 50~6rain sample is placed in a cylindrical container vith a perforated plate on the bottom and access to the atmosphere at the top. These are shovn in Figure 7. The sample is compressed until the cap can be tvisted into place to give a plug of asbestos of a standard height. The cylinder containing the sample is u -lU- J then twisted on"to the unit so "that; it is connected to a vacuum chamber. The machine is completely automatic in its operation from this point on. A hand wheel is -turned to apply a suction vhlch creates a vacuum chamber and displaces fluid in a U-tube. The handwheel is then turned to the measuring position which Jm opens up the vacuum chamber to the cylinder containing asbestos, and air flows from the atmosphere through the plug of asbestos and into the vacuum chamber. This causes the fluid in the U-tube to return towards its original position. In so doing, it contacts an electric probe which starts a clock and subsequently contacts another probe which stops the clock. The U-tube and probes are shown in Figure 8. The time on the clock is a measure of the time required to fill the vacuum chamber at atmospheric pressure and has been correlated to the surface area of the fiber. This is a straight line relationship, and the surface area can be read off of a chart shoving surface area vs time. The unit is calibrated by using capillary tubes standardized for the time required to fill the vacuum chamber with the tube substituted for the fiber. Calibration can also be accomplished by using a standard sample of known surface area. This unit is fast, gives reproducible results, and has little dependence cm operator variability. Gas Adsorption '" The principle of this technique is the adsorption of a gas onto the surface of the material being studied. If this adsorption is in a monomolecular layer and the amount of gas adsorbed is known, the total area can be calculated by knowing the area covered by one molecule of the gas. -15- "In practice the sample is placed in a high vacuum system and all adsorbed molecules are removed from the surface by the high vacuum. Heat is often ap plied to the sample to aid this desorption. A known volume of gas is then ad mitted to the system and is caused to adsorb on the sample by lovering the sample temperature. The amount adsorbed is determined by measuring the loss in pressure in the system, and the surface area can then be calculated. Unlike air permeability, -which measures only the area comprising the flew channels, gas adsorption measures all of the area in which the gas comes in contact. This will include internal pores unless they are blocked or are too small for the gas molecule to enter. A rough idea of the different results is shown by asbestos which may show an area of 2 sq meters by air permeability and about 20 sq meters by gas adsorption. In the case of quartz this ratio is only about 3 to 1 instead of 10 to 1, presumably because of the smoother surfaces and _ lack of internal pores. .Suter-Webb This is the test used to measure the length of asbestos fibers by physical means. It Is a tedious technique and the results are highly dependent on the proficiency of the operator. Fiber length is measured on a 200 mg sample which has been thoroughly combed out in a special metal wire comb. After combing, the fibers are placed in a series of similar combs spaced l/8-Inch apart and with one end of each fiber protruding no more than l/8-inch from the set of combs. Combs are dropped from the other end of the fibers until the first fibers appear as shown in Figure 9These are extracted from the comb and weighed. Their length is taken as l/8-inch times the number of combs remaining plus l/l6 in. Another comb is dropped and u -16- the fibers extracted and "weighed- This process is repeated until all the combs are dropped. The average length of the libers then be calculated Iron the sum of the veight times the length for each group divided by the total veight. Water Elutriation Test This is a technique used to measure the amount of bundles or grit content in asbestos fiber. It is not a practical test for fiber grades above 4d. The apparatus consists of a 3-d^oh diameter vertical glass tube approximately feet tall vith vater and air inlets at the bottom and appropriate methods for measuring the rate of flov. In operation the tube is filled half vay vith vater and a slurry of 10 grams of fiber in vater is added. Air is bubbled through the mixture to insure disper sion and. then the air rate is set at $0 cc/minute. Water is turned on at 3500 cc/ minute vith the overflov going out the top and carrying vith it the finer particles and highly opened fiber. After 9 minutes, the air is turned off and the vater flov rate is increased to 5^00 cc/minute for another 5 minutes. Figure 10 shovs a unit in operation vith the more crudy and longer fiber concentrated near the bottom of the tube. At the end of the test, the tube is drained into a beaker to collect the crude and grit materials. These are filtered, dried, and veighed. If desired, the crude can be separated from the grit by pulping the fiber and decanting it off. The re maining grit is filtered out, dried, and veighed. Air Elutriation This is a technique used to separate fine particles (belov ) from as- -17- bestos. The unit consists of an Inverted Ions-tapered cone vith an air inlet and a mechanical agitator at the bottom. Figure 11. The top is connected to a dust bag vfaicb filters the air leaving the system. The sample of fiber is charged into the unit through a small door in the side of the cone. The air flow and agitator are started vith the flow adjusted to give a minimum rate of 0.395 ft/sec through the largest part of the cone. Anything smaller than ^0 microns vill be carried out to the dust bag at this velocity and anything larger vill remain in the cone. At the end of the 9-minute test period, the air and agitator are shut off, the stopper at the bottom of the cone is removed and the material in the cone is transferred to a Bo-Tap screen. The screen is Bo-Tapped for one minute -without the hammer. The amount of fiber remaining on the screen is classified as fiber, that in the pan is listed as granular, and the dust content is obtained by the difference between the sample weight and the com-, bined weights of the fiber and granular. A 5-gram sample is used for group 3 fiber and a 10-gram sample for all others. In determining granular content, a 35 mesh screen is used for all groups except group 7 "which uses a 28 mesh screen. Although the sample is separated into three fractions by this test, the names of the fractions are based on particle size rather than actual shape or character. For instance, the dust fraction is any thing smaller than ^0 microns and I assure you that there is a lot of fiber in that portion. Likewise, there may be large granular particles in the part called fiber and a lot of fiber In the granular fraction. However, the test is useful to the asbestos fiber industry. Alpine Test This test separates a fiber sample into three fractions as in the air elu- u -18- J -triation "test but uses a fine screen instead of air elutriation "to separate the dust fraction. A 200 mesh screen is generally used the fines are pulled through the screen by a vacuum vhile a circulating air knife keeps bloving the fiber off the screen to Etir the fiber and prevent screen blinding. A unit is shewn in figure 12. The plus 200 mesh fraction be separated into fiber and granular parts by a one-minute Ro-Tap, as in the Air Elutriation test. A 10-gram . sample is used and the test is run for 10 minutes. Color In many applications, the color of asbestos fiber is not of any great concern but there are a. few cases vhere it is of prime importance. One of these is in asbestos-vinyl floor tile vhere the modem pastel shades cannot tolerate a dark asbestos -without extensive use of whitening agents. In testing for color a dry pellet of asbestos is made by compressing a 10graa sample of fiber in a l-l/8-inch diameter cylinder with a stress of 16,000 psi on the asbestos pellet. In this condition the pellet can be easily handled. The color is measured in a photovolt photoelectric reflection meter vith green, amber, and blue filters. The unit is calibrated vith a standard reflectance plaque by setting the galvanometer at the reading specified for the plaque. The fiber pellet is substituted for.the plaque and the color rating read directly off the galvanometer. A good color asbestos will range from 60 to 70 units as com pared to a value above 90 for titania. Chemical Analysis Standard techniques are used to make chemical analyses of asbestos, and I am not going into any detail on the specific procedures used. Suffice it to say that u -19- ) the- more common tests are for cations and vater content. The elements most com monly tested for are magnesium, silicon, iron, aluminum, and calcium. A more coTiplete analysis vould include nickel,-potassium, sodium, phosphorous, titanium, manganese, cobalt, mercury, copper, lead, and sulfur. All of these are generally reported as the more common oxide. Vater can include both the absorbed vater driven off at about 220F vhich is usually in the range of one to tvo per cent, and combined vater vhich is driven off by ignition at 1800F and may include other volatiles or oxidation. Combined vater vill vary from 12 to ll+$ for chrysotile but is only about 2$ for the amphiboles (blue, amosite, anthophyllite). In addition to these determinations, it is very common to determine the total vater-soluble content and the vater-soluble chlorides. A 10-gram sample is soaked in 100 ml of distilled vater for 2^ hours at room temperature. An alf.cquot portion i-; evaporated and the dried residue is proportional to" the content of vater-soluble material. Another portion of the vater filtrate is tested for chloride content. The Volh&rd method vhich precipitates the'chloride vith silver nitrate is generally used because it gives the accuracy desired in the parts per million range generally encountered.' The test is carried out at a neutral pH using a potassium chromate indicator. It Is accurate dovn to about 10 parts per million Vater solubles vill generally be in the range of 0.10$ to 0.35$ vhile chlorides gill vary from a trace to 0.20$ (2000 ppm). Jg' Determinations of pH can be made by any standard method but a pH meter .util izing a standard glass and calomel electrode is a convenient technique. Special care must be taken in these measurements because a higher value vill be obtained if the electrode tips are in the slurry than If they are in the supernatant liquid. u -20- J "Values can range from 9*20 In the aupematant liquid to 10.33 iu the slurry on -the same sample. Electrical Properties ' Volume Resistivity This test procedure follows the requirements given in ASTM D-257. Essentially it consists in compressing about 20 grams of asbestos at 260. psi in an insulated cylinder with a cross-sectional area of one square inch. The resistance of the asbestos plug is measured after one minute at 500 volts a.c. and is reported in megohm-inches. Tests are generally run after the asbestos has been conditioned under three different atmospheres. First the sample is dried for 16 hours at 230F and tested. The same sample is then conditioned for 72 hours at 75? nd 50# relative humidity and tested. Finally, the same sample Is tested after con ditioning for 16 hours at 75F and 91$ relative humidity. Our test laboratory is maintained at the second condition and a saturated sodium tartrate solution -will give the third condition. Values for resistivity will range from about 500 for -the best chrysotiles under the dry condition to less than 0.005 for a poor chryso"tile at 91$ humidity. Magnetic Eating This is an empirical number that relates the electromagnetic effect of an unknown sample of asbestos vs a standard sample. I will cover only the basic mechanism. Ten grams of asbestos are placed in a test tube in a coil vhich forms one arm of an inductance bridge. The other ana is a similar inductance -rrvH Anri the rebalance required measures the magnetic rating. This test measures the magnetic effect of iron compounds in the sample and depends on the permeability, size, shape, and orientation of the particles as . o -21- veil as the quantity. The procedure is given in ASTM D-1118. Magnetic ratings Tor asbestos vill range from zero to as high as k.6. Conductance ._ This is a test that is used to give an indirect measure of the ionic water solubles in asbestos. A 50-gram sample of asbestos is extracted overnight with 500 ml of water at room temperature and the conductivity, or rather resistance, of the filtrate is measured. Conductance is reported in terms of micromhos/cm, and asbestos vill give values In the range of 100 to 300 micromhos/cm. Conductivities are often expressed in terms of equivalents of sodium chloride but this does not mean chlorides have to be present. Any ionizable salt would increase the conductivity and the value simply states that the same conductivity would be obtained if that quantity of sodium chloride were in' the water. Equiva lents of sodium chloride of about 0.05 to 0.1^ correspond to conductances of 100 to 300 micromhos/cm. Eeferences 1. The Properties of Asbestos.il.The Density and Structure of Chrysotile. F. L. Pundsack, J. of Physical Chemistry, 60, 361 (1956} FIGURE 2. QUEBEC STANDARD TEST UNIT * * piGURE X RO-TAP TEST UNIT FIGURE 4. BAUER McNETT TEST UNIT / FIGURE 5. CLARK CLASSIFIER O -)