142 Division of Arnold A. Kosarin & Associates Inc. 6970 West Jefferson Avenue Detroit, Michigan 48217 MAKE-UP AIR HEATERS ASHRAE Guide And Data Book Tested and rated in accordance with ASHRAE Standards 4555 for Heavy Duty Furnaces and Direct Fired Heaters. DIRECT FIRED HEATERS MAKE-UP AIR BY ARKOS GIVES YOU MORE! Gas valves and controls completely enclosed . . . To protect them against air contaminants. To eliminate tampering. To protect against physical damage. Two automatic safety shnt-oS valves furnished as standard . . . In the event pipe scale or other obstructions should cause malfunction of one valve, the second valve would still be operable and protect against gas leakage. All major components are supported by separate heavy duty structural members... So that none of the weight or strains of shafts, blowers, drives, couplings, or motors are transmitted to blower housings or outer casing. This promotes longevity, reduces maintenance and minimizes vibrations. Adjustable profile plates__ Permits held adjustment of air velocity over burner section. Permits optimum performance of burner under field conditions of varying CFM and external static pressure. The safety circuit has a back-up control for every major safety control... In the event any safety control should fail, its function would be taken over by another safety control, incorporated into the system. All electrical controls contained within the gasketed control panel are bolted to a separate sub-base . . . To facilitate service and insure that moisture and air borne contaminants cannot find their way into the panel to the detriment of the components. Each heater flame tested prior to shipment. Standard packaged beaters available in capacities from 3000 to 61,000 CFM. Larger sizes built to requirements. F.I.A., F.M. and J.I.C. compliance where applicable. Designed for outdoor or indoor installation. Filters and dampen available option. ENGINEERING DATA Heater F"" IX X XI xn xni XIV XV XVI CFM Min. Max. 6,000 8,500 10,000 14,000 20,000 29,000 36,000 40,000 9,000 13,000 17,000 22,000 30,000 39,000 47,000 61,000 H. P.* Mia. Max. 1 m 2 3 5 7^ 10 15 5 10 10 15 20 25 30 40 BTU/HR. XM Min Max. 400 600 800 1,000 1,600 2,200 2,800 3,000 1,200 1,600 2,200 2,800 3,800 5,000 6,000 8,000 * Will vary with CFM ft 1LSJ\ required. 400,000--3^00,000 BTU/hr. output. Diamond-shaped stainless steel combustion chamber for maxi mum combustion volume and heat transfer. Tea year warranty. Automatic or manual switch-over on combination gas-oil burners. Four point floating chamber suspension allows free movement during heating and cooling. Radiation shield insures cool outer easing by providing live air insulation. Available for horizontal or inverted mounting, complete with vibration isolators. Gasketed dead-front control panel for maximum safety. Color-coded wiring facilitates servicing. Power rated burner for gas or oil firing. NAFM certified, heavy duty, double inlet, double width blowers. UL tested and approved for oil, gas, or combination, for both induced draft or forced draft operation. Completely wired, assembled and flame-tested prior to shipment Heater Model A-40 A-55 A-65 A-75 A-85 A-100 A-125 A-150 A-175 A-200 A-275 A-350 ENGINEERING DATA Btu Output CFM J*j Ft^ Blown Motor Hp 400,000 550,000 650,000 750,000 850,000 1,000,000 1,250,000 1,500,000 1,750,000 2,000,000 2,750,000 3,500,000 5,500 7,200 8,100 9,300 10,600 13,200 16,500 19,800 23,100 26,200 36,300 46,200 . 130 130 155 155 218 218 356 356 475 475 673 673. 1 IM 2 2 3 5 5mm 10 15 20 Catalog Data Section 143 PEERLESS PUMP FMC Corporation PLANTS: Los Angeles, Calif. 90031 301 West Avenue 26 Indianapolis, Ind. 46208 2005 Northwestern Avenue Offices: New York; Detroit; Cleveland; Tampa; Atlanta; Indianapolis; Chicago; St. Louis; Denver; Dallas; Plainview, Lubbock, Texas; Phoenix; San Francisco, Fresno, Los Angeles, Calif. FOR HANDLING HOT, CHILLED, CLEAR OR CONDENSER WATER Peerless Fluidyne end-auction dose-coupled pump Peerless AquaLine horizontal centrifugal split case pump For Ilydronic Systems Peerless DM-DMR High Temperature High Pressure Pumps HP range: 1 to 40 HP. Capacities: SO to 800 gpm. Heads: up to 260 ft. Design: single-stage, end-suction. Drives: standard horizontal NEMA motor. Screwed and flanged connec tions. Sealed and packed types. Bronze impel ler. Compact, versatile, dependable and effi cient. Good hydraulic characteristics- Extremely durable and economical to operate. Com pletely described in Bulletin B-2300. For hot and cold water handling, circulation and boosting. Discharge sizes: I Vi in. to 10 in. Capacities: up to 2600 gpm. Heads: up to 350 ft. Temperature range: up to 250* F. Drives: _ motor. The AquaLine volute is cast iron, bronze fitted, impeller is cast bronze. Availa ble witb packing gland or replaceable me chanical shaft seals. Highly dependable and economical to operate. Fully described in Bulletin B-2100 ' Peerless Type A horizontal centrifugal split case pump Peerless Vertical Pumps For application to cooling tower service, tank pumping. line pump ing. boosting and recirculation. Capacities: 30 to 40,000 gpm. Heads: to 1000 ft- Hp range electric, op to 2500 hp; right angle gear drives, up to 300 hp; steam turbine, as re quired. Pump column sizes: 2t4 in. to 30 in. inclusive. Liquid tempera ture range: to 250*F. Available in water lubricated open line-shaft construction and enclosed line-shaft oil lubrication types. Described in Bulletin B-S0S. Peerless Hydro-line encased, vertical close-coupled centrifugal pump Especially suited to pumping hot or cold water where floor space or NPSH is a problem. Capacities: up to 5000 gpm. Heads: to 3000 ft. Temperatures: up to 300*F. Drives: as re quired, standard vertical solid shaft or hollow shaft motors, steam turbines. Request Bulletin B-1700. For the widest variety of pumping services. Capacities: to 60.000 gpm. Hods: to 400 ft. Single stage, split case design. Drives: directconnected electric motor; belted drives; diesel, natural gas, and gasoline engine; steam tur bine; combination drives. Double-suctioo sizes IH in. through 42 in., bottom suction sizes 12 in. through 42 in. Completely described in Bulletin B-H00. For Multi-Stage pumps, ask for Bulletin Peerless Deep Well Pump For water supply services. Capacities: 15 to 30,000 gpm for installations in 4 in. wells or larger, to any practical depth. Adaptable to motor, belt, gear or steam drives. This tur bine pump features several design advantages special witb Peerless; the cooling method, unique bearing contact, and packing arrange ments are examples. Available in water or oil lubricated line-shaft types. Fully described in Bulletin B-Hl. Ideally suited for handling super heated water in hydronic systems. Easy to apply. Proven per formance. Discharge sizes: 1 in. to 5 in. Capac ities: up to 1000 gpm. Heads: up to 430 ft. Temperatures: to 430*F. Type DM is base mount while DMR is center line mount. In tegrated design of pump permits maximum part interchangeability, reduces inventory of spare parts. Pumps are fully described in Bulle tin B160S PM) and B-1610 (DMR). Peerless Hydro-Constant Pressure Systems Maintains constant bouse system pressure un der extreme variations in flow demands. This new proven system eliminates need for pressure tanks. Conserves valuable floor space. Main tains pressure within 2 png. All changes are automatic. Described in Bulletin B-40-l. Investigate the complete Peerless Pump Line Peerless produces a comprehensive and com plete range of pumps for practically all water handling requirements. Most of these pumps are suited to a variety of drives. Write us indi cating your pump requirements.