Document D2w3Xj0MqDaJ3M7jKZDKBMo5

PLASTER PLAINTIFF'S EXHIBIT SGP 0026879 1972 lath & plaster for wall and ceiling systems SGP 0026880 FINISHESQ Lath and Plaster Georgia-Paci Corporation January, 1972 nu c u i y i d - r d t n i t u u ip u r d iiu n January, 1972 n ^ io n to Lath and Plaster GYPSUM PLASTER G-P laths and plasters, although always consistently a su perior product, have one unique and important additive which makes them very much in demand. This is the addi tion of uniform length, high strength glass filament fibers. The fiber glass content of G-P fibered plasters and laths is an important factor to consider in specifying lath and plaster construction. Fast Machine Application Literally miles of glass fibers (19.75 miles per bag of fibered plas ter) offer greater resilience and bonding properties that resolve many job difficulties. Glass fiber reinforcement provides greater speed in application which in turn results in better economy. G-P plasters, designed for machine application, give greater con struction economies and added design possibilities. Glass fibered plaster may be used when fibered plaster is specified. Due to the plasticity and richness of these plasters they will not clog the mixer, hose or nozzle. Even the glass fibers go through. DENS-COTE Veneer Systems Dens-Cote (one coat) system is designed for use whenever a strong durable finish with maximum speed and minimum material is desired. One application of only y32" minimum thickness DensCote Smooth Finish (or Textured Finish) over Dens-Cote Gypsum base, is all that is needed to give lasting strength and beauty to any construction. Dens-Cote System (two coat). This system is designed for those who prefer the conventional type finishes but desire modern speed and minimum material. The specially designed Dens-Cote Plaster, stronger than conventional sanded plasters, base shall be applied Va" thick over Dens-Cote Base to achieve the best results. As in the one coat system, the Dens-Cote Base Plaster can also be used over porous masonry block with excellent results. After the first coat of Dens-Cote Base Plaster has set, finish with lime putty and gauging for a conventional smooth finish, or use any sand float textured finish. For a hard durable smooth finish, use Dens-Cote Smooth Finish. Description Uses Features Neat gypsum plaster (Unfibered, Fibered, and Extra Fibered) Basecoat plasters bond securely to any standard plaster base including gypsum lath, metal lath and masonry units. Neat gypsum plasters require addition of aggregate and water. 1. UNFIBERED: is used for scratch coat on solid surfaces and for the brown (second) coat on any backing. 2. FIBERED: is recommended to provide greater wet cohesion and to minimize droppings with open type lath. 3. EXTRA FIBERED: is used for greater wet cohesion over metal lath as may be specified. DURABILITY: Applied according to specifications it provides uniformly strong, stable walls and ceilings. PLASTICITY: Special scientifically controlled process maintains plasticity and easy workability. FIRE RESISTANT: Gypsum's natural incombustibility offers superior fire protection. Lite-mix plaster (Unfibered, Fibered, Masonry Mix) Basecoat plaster that is 50% lighter than Gypsum and sand plaster. Fibered mix contains glass fibers for added strength. Requires addition of water only. 1. UNFIBERED: is used for scratch coat on solid surfaces and for the brown (second coat on any backing.) 2. FIBERED: is recommended to provide greater wet cohesion and to minimize droppings with open type lath. 3. MASONRY MIX: Available for application on masonry bases. FIRE RESISTANT: Perlite aggregate provides higher fire resistance than sanded plasters. MIXES SMOOTFILY: Has no tendency to clog mixer or to block the nozzle of the plaster gun. HIGH INSULATION VALUE: Provides greater insulation than sanded gypsum plaster. Wood fibered gypsum plaster Non-staining shredded wood fiber additive provides good working-properties when used without aggregate. (Limited Availability) Gauging plaster Specially ground gypsums designed to blend with lime putty. Intended for use without aggregate as scratch and brown coat, but may be mixed with one part of sand. For scratch coat over high suction masonry it is recommended that one part of sand be used. ECONOMY: Can be applied quickly and easily. STRENGTH: Has 3 times greater compressive and tensile strength than sanded plaster; up to 2y2 times greater resistance to lateral impact and 50% greater surface hardness. Mixed with lime to provide base for final wall and ceiling decoration. Usually over a gypsum plaster basecoat, Vis" to Va" thick. Available in "Slow Set" or "Quick Set." WHITE COAT FINISH: Satin Spar Gauging Plasters are very white and when properly mixed with lime putty they provide glossy smooth, flawless, surface of uniformly excellent, satin-like finish. Finishing limes Produced from ground quicklime by adding an exact amount of water which chemically converts the quicklime to calcium and magnesium hydroxides. Completely aerated to prevent lumping in the bag. Precision ground to produce the correct fineness for maximum plasticity and workability. To be mixed with gypsum gauging or Keene's cement for lime putty white coat. Supplies a white durable finish that preserves and beautifies interior walls and ceiling. Makes walls less brittle, less subject to cracks. Keene's cement A high strength, "dead-burnt" white gypsum gauging plaster. Provides stronger, harder surface when substituted for gauging plaster in a lime mix. Less lime, harder finish. Available regular and Fast Set. Because of denser, harder surface has higher resistance to abrasion and water absorption it is highly suitable for kitchens, bathrooms, hospitals, and any area where wear and moisture resistance are important. LOW WATER ABSORPTION: Because of high density, has low absorption. VARIOUS FINISHES: Mixed with varying portion of lime, gives standard, medium hard or extra hard finishes. F/2 For rated fire resistive construction use G-P Bestwall gypsum products with G-P Paneling. See "Georgia-Pacific Guide to Products for Interior Paneling." SGP 0026881 QUICK SELECTOR CHART For Georgia-Pacific Plaster Products NAME NEAT Unlibered Fibered Extra Fibered USES COVERAGE (sq. yds per (on) THICKNESS Scratch coat on solid surlaces. Brown coat on any surface. Scratch and brown coat on all surfaces except monolithic concrete. Scratch coal on metal lath but may be used over all bases except monolithic concrete. (sanded 2i) Gypsum Lath: 190-220 Metal Lath. 100-UO Gypsum Tile: 210-240 Clay Tile: 165-200 (same as above) w- Vi* Vi* vV,i-- (same as above) (same as above) (same as above) LITE-MIX Unfibered, Fibered Masonry Mix Where lightweight desired Ready mixed, add water only. Faster, easier application. For use over high suction masonry base. Gypsum Lath: 135-150 Metal Lath: 75-90 Gypsum Tile: 135-150 Clay Tile: 110*125 Vfc" Vj" V." WOOD FIBERED Without sand-scratch coat and brown coat on all backings except masonry. With sand-scratch coat on masonry and brown coal on ail backings. (without sand) Gypsum Lath: 100-120 Metal Lath: 50-65 Gvosum Tile. 85-100 Ciay Tile: 65-65 Vi' Vvr Yt* SATIN SPAR GAUGING (White) Mixed with lime lor use over gypsum basecoat. Great workability, hard, smooth white surface. Available m quick set or slow set. 1600 <3.l> Mixed 3 parts lime putty to 1 part gauging (Mm.) G-P GAUGING Mixed with lime lor use over gypsum basecoat. Selected quality rock, light gray color. Gives hard, smooth surface. Available in quick or slow set. 1600 V (3 1) Mixed 3 parts lime putty to 1 part gauging (Mm.) KEENE'S CEMENT Mixed with lime. Gives strong, dense surface with resistance to abrasion and water. Two sets regular and fast finish. (4.1 Mix) 550 */' MOLDING DENS-COTE SMOOTH FINISH Made trom rock over 98% pure. Gives hard, strong molds and coats with low expansion. Mixed with lime and water tor ornamental features. Mixed with water only. For thin coat application to Dens-Cole Gypsum Base. Up to 400 Vu* Minimum OENS-COTE TEXTURE FINISH Same application as Smooth Finish Mill mixed lextu/e male/iai, texture with lloal as desired. Up to 400 '/' Minimum DENS-COTE BASE PLASTER First coat in two coat veneer plaster system. Finish may be Smooth Finish or Lime Putty mixed wilh gauging. Up to 400 >/u* Minimum Dens-Cole Smooth or Textured finish may be applied to masonry Block m two coat application Base coat minimum thickness o! v% enough to straighten wall. mish coat may be smooth or textured as desired. or FINISHING LIME SMOOTH FINISHING (Normal Hydrated) BUILDERS (Autoclaved) (Ohio Dolomite) Mixed with gauging. molding piaster or Keene's Cement to give plasticity, whiteness and bulk. Up to 750 LIME PRODUCTS G-P Smooth Finish Lime A normal hydrated lime that must be soaked approximately 16 hours and then blended in proper proportions (one gal lon of gauging plaster to every three gallons of lime putty) with gypsum gauging plaster which provides initial set and strength avoiding shrinking cracks. G-P Builders Lime This finishing lime is made from the same quicklime as G-P Smooth Finishing Lime, but is hydrated in a steel Auto clave (pressure vessel). Water is injected and after the quicklime satisfies its chemical thirst for water, the lime is removed from the Autoclave chamber as dry hydrate and undergoes aeration to remove any possible uncombined moisture. This lime has less than 8% of unhydrated oxides and pre vents "lime pops." Builders Lime need only be mixed with water to a putty consistency and can be used without soak ing. G-P Builders Lime has more workability and plasticity than other finishing lime. G-P Mason's Lime This is normal hydrated lime made from quicklime and-- except for its coarser quality and shorter aeration process --the manufacture, hydration and milling are approximate ly the same as for G-P Finishing Limes. G-P Mason's Lime should be soaked at least 12 hours in putty form before use in mortar... it should not be used as finishing plaster be cause the finish will not be up to standard and "pops" may occur. G-P Speedy Mason's Lime This is the original Type "S" Special hydrated lime, a quick mix lime that need not be soaked in putty form before use. Produced by a continuous pressure on Autoclave system. G-P Speedy Mason's Lime differs from Aufoclaved Finishing Lime only in the coarser quality of the quicklime used. Efflor escence is minimized because the lime is free of soluble salts. Beam fireproofing Fireproofing of beams and col umns is accomplished by abut ting 3/s" G-P Type "X" Lath around the perimeter of the beam or column and plastering the thickness required for de sired fire resistance rating. The Type "X" lath is held by tying double strands of the wire around the lath and spaced 16" o.c. corner heads applied by staples or tie wire provide ground for proper thickness as well as straight true corners. Sanded plaster is used for fire ratings up to three hours. Light weight aggregates provide fire ratings up to four hours. A four hour column rating requires two layers of Vz" thick gypsum lath. SGP 0026882 F/3 GYPSLJM LATH Type and Size Plain lath Consists of core of gypsum rock reinforced with glass fibers sandwiched between two layers of special paper covering. This is standard basic construc tion for all G-P Lath. SIZE: 16 "x48", 16"x96'', 3/g" or V2" thick (16(4"x48" West Coast only) Long-length lath The same structure as Plain Lath except in dimensions SIZE: Available in Vi" or 1" thicknesses--24" x floor to ceiling lengths (12' maximum) Uses The standard gypsum plaster base for nail, staple or clip application to wood or steel framing. This construction material is especially designed for use as a plaster base for thin (2") solid partitions providing fire resistive ratings up to two hours. Can also be used with furring over exterior masonry walls as a plaster base. Description The exposed layer is porous and absorbent, permitting water in the plaster to penetrate the surface. As plaster sets, gypsum crystals pierce the paper surface forming mechanical key on the lath thus assuring maximum bond. Lath paper has water resistant inner plies which prevent the water in the plaster from soaking through it and thus minimizes sagging of the lath and plaster. The layer against the core is porous and absorbent so as to bond the core as the plaster sets. Long Length Lath comes in lengths up to 12', providing for wall assemblies in floor to ceiling heights. Ideal tor solid plaster par titions. Since there is less lathing in job--there is a saving in con struction costs. Glass fiber reinforced for added strength Fast and economical to erect. Application: Both plain and Long-Length Lath may be applied by nailing to wood and nailing-type steel framing, and to wood fram ing by staples. They can be easily attached to metal sections and furring, and to wood with lath clips. Resilient type clips reduce cracking and lessen sound transmission. Pinholath Plain Lath construction surface perforated with l/i6" d'a- holes. Space Vs" o.c. diagonally. SIZE: 16"x48", 16"x96", %" or Vi" thick (16(4"x 48" West Coast only) Specially designed for machine applied plasters. Fast, high, even water absorption speeds plaster application by holding plaster in place during rbdding and darbying. When attached to ceilings by clips, three coat work is required. The Scratch Coat should be dry before applying Brown Coat if high humidity condition exists. When Perimeter Clips are used on ceilings, Butt and Center Clips should be used. G-P PINHOLATH is plain lath surface-perforated in manufacturing with pin holes no larger than (/16" in diameter, spaced %" o.c. diagonally. Specially designed for machine applied plasters. Its unique feature permits rapid suction of water from plaster mix to achieve perfect plaster consistency speeding plaster application. There is no plaster slide, no backtracking, no costly delays. Plas ter stays in place during rodding and darbying which can be done sooner when using PINHOLATH. Full base coat coverage is ob tainable in one operation. Type "x" lath Plain lath construction. SIZE: 16" x 48", %" or Vi thick (16(4 x 48" West Coast only) Available also: pinholed and insulating. Applications identical to Plain Lath. A wood stud partition faced with Type "X" lath and full thickness of plaster specified has one-hour fire rating. G-P Type "X" Lath is plain lath with a special core formulation that provides necessary fire ratings for various constructions. Application: Type "X" Lath may be applied by nailing to wood and nailing-type steel framing, and to wood framing by staples. It can be easily attached to metal sections and furring, and to wood with lath clips. Resilient type clips reduce cracking and lessen sound transmission. Printed face identifies Type "X" Lath. Insulating lath Plain lath with aluminum foil laminated on back. SIZE: 16"x48", %" or Vi" thick. Rounded Edges Designed primarily for application to exterior walls and top floor ceiling. Back side must face a minimum air space of %" to develop reflective insulation value. Constructed exactly as PLAIN LATH this lath has aluminum foil laminated to the back. This foil reflects up to 90% of radiant heat and acts as an efficient vapor barrier. Designed primarily for application to exterior walls and top floor ceilings. When installed the aluminum reflective surface must face a minimum air space of %'' to develop reflective insulation value. Dens-cote gypsum base A 4' wide, long-length, tapered edged, plain lath construction. It has a highly absorbent lath type face paper with surface pin holed. SIZE: 4' x 8', 10' and 12'; Vi thick (%" and Vi" and Vs" Type X Firestop on order) Specially designed for reception of Dens-Cote Smooth and Texture Finish and other thin coat plasters. G-P Dens-Cote Gypsum Base is a Vi" and Vs" thick, 4' wide, tapered edge, gypsum board product, specifically designed to receive Dens-Cote Plasters. It has a highly absorbent lath type face paper with the surface pinholed. Available in lengths up to 12', is shipped twin mounted. Large sheets decrease number of joints, giving greater strength and crack resistance to wall and ceiling surfaces. The Dens-Cote System is designed for fast erection and early occupancy; produces a wall with a strong, hard monolithic finish. Combines economy of installation with virtually unlimited deco rative possibilities. F/4 For rated fire resistive construction use G-P gypsum products with G-P Paneling. See "Georgia-Pacific Guide to Products for Interior Paneling." SGP 0026883 it, pla STEP WALL SYSTEMS Technical data--Fire ratings & sound transmission values for gypsum lath & plaster wall systems FIRE RATING PARTITIONS PLASTER WEIGHT LBS. STC THICKNESS THICKNESS" PER SQ. FT. TYPE BASE PLASTER MIX"" 2" x 4" WOOD STUDS 16" ON CENTER 1 Hour 40 5%'' Vz" 15 1 Hour - 5%" Vz" 12 45 Min. 40 5%" Vz" 14.7 1 Hour - 5%" Vz" - 1 Hour - 5%" Vz" - 1V2 Hour - 5%" Vz" _ 1 Hour 40 5y8" 3/4" - 2 Hours 41 5%" r - 1 Hour 40 5%" 3/4" - 1 Hour 40 5%" 3/4" - 1 Hour 35 43/4" 3/32" 7.7 2 Hours 41 6" 3/32" 13.8 Vs" G-P Plain Gypsum Lath 3/8" G-P Plain Gypsum Lath 3/8" Plain Gypsum Lath %" Plain Gypsum Lath Vs" Type "X" Gypsum Lath Vs" Type "X" Gypsum Lath Metal Lath 3.4 D. M. Metal Lath 3.4 D. M. Metal Lath 3.4 D. M. Metal Lath 3.4 D. M. One layer Vz" G-P Firestop Dens-Cote base, both sides Two layers Vs" G-P Firestop Dens-Cote base, both sides Gypsum-Sand 1:2 Gypsum-Perlite 1:2 Gypsum-Sand 1:2,1:2 Gypsum-Wood Fiber Gypsum-Sand 1:2,1:2 Gypsum-Perlite 1:2, 1:2 Gypsum-Sand 1:2,1:3 Gypsum-Wood Fiber Gypsum-Perlite 1:2,1:2 Gypsum-Vermiculite 1:2 Dens-Cote smooth finish Dens-Cote smooth finish SOLID PARTITIONS 1 Hour 1 Vz Hour 2 Hours 1 Hour 1 Hour 2 Hours 34 - 37 36 33 34 2" 2" 2" 2" Wz" IVz" METAL STUD 1 Hour 1 Hour 1 Hour 1 Hour 1 Hour 44 5%" - 5% " 35 5%" - 53/8" 35 5%" 1 Hour 41 " 53/8" 1 Hour 45 5H" 2 Hours -- Vk" 1 Hour 38-40 3 Vie" 2 Hours 48-50 4u/i6" 2 Hours 49 65/16" V4 " 3/4" 3/4" 1" 3/4" 1%" %" Vz" Vz" Vz" Vz" 3/4" Vz 3/4" 3/32" 3/32" %2" 16.5 3/2" Long Length Gypsum Lath - Vz" Long Length Gypsum Lath 10.9 Vz" Long Length Gypsum Lath 18.1 Metal Lath 7.4 Metal Lath - Metal Lath Gypsum-Sand 1:1,1:2 Gypsum-Perlite 1:2 Gypsum-Perlite or Vermiculite 1:2,1:2 Gypsum-Sand 1:2,1:2 Gypsum-Perlite 1:2 Gypsum-Perlite or Vermiculite 1:2,1:2 14 Vs" G-P Pinholath, 3%" Stud Gypsum-Sand 1:2 10 Vs" G-P Pinholath, 35/s" Stud Gypsum-Perlite 1:2 16 3/8" Plain Gypsum Lath, 35/8" Stud Gypsum-Perlite 1:2 16-21 Vs" Pinholath, 3%" Stud Gypsum-Sand 1:2 16-21 Vs" Type "X" Gypsum Lath Gypsum-Sand 1:2, 1:2 3%" Stud 21 Metal Lath, 35/8" Stud Gypsum-Sand 1:2,1:3 11.8 3/8" Gypsum Lath type X attached with Gypsum-Sand 1:2 clips each side of 23/2" steel stud 15 Vs" Type "X" Gypsum Lath Gypsum-Perlite 1:2,1:2 1%" Stud 7.0 One layer Vs" Dens-Cote base, both Dens-Cote smooth finish sides, IVs" metal stud 9.8 Two layers Vz" Firestop Dens-Cote base, Dens-Cote smooth finish both sides--2Vi" metal stud 12.8 Two Layers Vs" Firestop Dens-Cote Dens-Cote smooth finish Gypsum Base, Both sides--3% " metal stud COLUMNS (STEEL) 1 Hour 2 Hours 2 Hours 3 Hours 4 Hours 1 Hour 4 Hours - - - - - - Vz Ws" 1" 1%" iy2" %" 13/4" Face of Lath to Face of Finished Surface 1 Part of Gypsum Plaster (100 Lbs.) to Cu. Ft. Aggregate - - - - - - Vs" Type "X" Gypsum Lath 3-a" Type "X" Gypsum Lath Vs" Type "X" Gypsum Lath Vs" Type "X" Gypsum Lath 2 Layers Vz" Plain Gypsum Lath Metal Lath Metal Lath Gypsum-Sand 1:2 4 Gypsum-Sand 1:2,1:3 Gypsum-Perlite 1:23/2 Gypsum-Perlite 1:2.1:3 Gypsum-Perlite 1:2,1:3 Gypsum-Sand 1:2. 1:3 Gypsum-Perlite 1:2, 1:3 SGP 0026884 F/5 PLAST CEILING SYSTEMS Technical data--Fire ratings & sound transmission values for gypsum lath & plaster ceiling & floor assemblies. CONSTRUCTION FIRE RATING WEIGHT LBS. STC THICKNESS* PER SQ. FT. TYPE BASE PLASTER MIX*0 WOOD JOISTS AND FLOOR Assembly *1 1 Hour 1 Hour 1 Hour 45 min. 1 Hour 1 Hour m Hour 1 Hour -- - - 40 - 34 - -- Assembly-2 1 Hour 44 Assembly *3 2 Hours Vi" Vi" Vi" Vi" Vi Vi" Vi" 3/32" 3/32" 3/32" -- 3/g" G-P Pinholath Gypsum-Perlite 1:2 - *%" G-P Pinholath Gypsum-Sand 1:2 - *%" Type X Gypsum Lath Gypsum-Sand 1:2 12.5 %" Type "X" Gypsum Lath Gypsum-Sand 1:2 - V%" Type "X" Gypsum Lath Gypsum-Perlite 1:2 17.5 Metal Lath Gypsum-Sand 1:2, 1:3 - Metal Lath Gypsum-Perlite 1:2, 1:2 13.9 Vi Firestop Dens-Cote Base, Dens-Cote Smooth or textured finish one layer nailed 13.0 Vi Firestop Dens-Cote Base, Dens-Cote Smooth or textured finish one layer on resilient channel 16.9 %" Firestop Dens-Cote Base, Dens-Cote Smooth or textured finish two layers with resilient channel 24" o.c. between layers STEEL JOISTS (2" Floor Slab) Furring Channels 16" o.c. 16" o.c. 16" o.c. 16" o.c. 12" o.c. 16" o.c. 1 Hour 1 Hour iy2 Hour - 3 Hours 3 Hours - - - - Vi" Vi" 1" Vi" U/l6'' 9/l6" 12" o.c. 4 Hours -- 1" 2 Hours 3 Hours 4 Hours - - - 3/4 " 13/l6" 1" - - - - - Vi" Type "X" Gypsum Lath (Clips) 3/8" Type "X" Gypsum Lath (Clips) V%" Type "X" Gypsum Lath (Clips) Vi" Type "X" Gypsum Lath (Clips) 3/g" Type "X" Gypsum Lath (Clips) 3/g" Type "X" Gypsum Lath Plus 1" Mesh 3/g" Type "X" Gypsum Lath (Clips) Plus 1" Mesh Metal Lath Metal Lath Metal Lath Gypsum-Perlite 1:2 Gypsum-Vermiculite 1:2,1:2 Gypsum-Perlite 1:2,1:2 Gypsum-Perlite 1:2 Gypsum-Perlite 1:2,1:2 Gypsum-Perlite 1:2 Gypsum-Perlite 1:2,1:3 Gypsum-Sand 1:2, 1:3 Gypsum-Perlite 1:2,1:2 Gypsum-Vermiculite 1:2, 1:2 STEEL FLOORS 2 TO 2%" CONCRETE FLOOR WITH SUSPENDED CEILINGS 12" o.c. Assembly *1 2i/2" Concrete floor over metal lath over steel bar joists 24" o.c. Assembly ~1 2" Concrete floor on joists 24" o.c. 3 Hours 4 Hours 4 Hours 2 Hours 2 Hours -- - - i/2" on ceilings 1" Vi" %2" -- - 39.4 3/:32" 37.3 3/g" Type "X" Gypsum Lath Plus Clips and Wire Reinforcing Metal Lath Metal Lath Vi" Firestop Dens-Cote Base, one layer screwed metal furring 24" o.c. Gypsum-Perlite 1:2 Gypsum-Perlite 1:2, 1:3 Gypsum Wood Fiber Dens-Cote Smooth finish Vi" Firestop Dens-Cote Base, one layer screwed metal furring 24" o.c. Dens-Cote Smooth finish =Face of Lath to Face of Finished Surface * '1 Part of Gypsum Plaster (100 Lbs.) to Cu. Ft. Aggregate NOTE: All tables are summaries only, based on tests at Underwriters' Labora tories, National Bureau of Standards, University of California, Ohio State University, Geiger and Hamme, Riverbank Laboratories and/or Ohio Research corporation sponsored by the G-P Gypsum Division, Gypsum Association, Metal Lath Association, Perlite Institute, Vermiculite Institute or others. The fire rating, weight and sound characteristics are based on a combination of specific details as tested and published. More complete Listings and Details are available. INCONSISTENCIES IN TEST RESULTS ARE DUE TO TESTS OVER A PERIOD OF MANY YEARS AND VARIATIONS IN LABORATORY FACILITIES. All of the test results have been obtained under laboratory testing conditions where controlled environment reduces variables to a minimum. In the field, such laboratory conditions are not always met, since many other variables are introduced. Laboratory results may exceed results of field tests, but the labora tory tests under controlled conditions are the only logical way to compare the performance of different assemblies. The Gypsum Division of the G-P Corpora tion makes no warranty that the performance of assemblies in the field will have a performance equal to or better than that developed in the test. NOTE: Floor and Ceiling assemblies (Incombustible), Bestwall Firestop DensCote Base, may be direct attached or suspended. F/6 For rated fire resistive construction use G*P gypsum products with G-P Paneling. See '"Georgia-Pacific Guide to Products for Interior Paneling.'' SGP 0026885 D E I\J S - C CJ T E PLASTER VENEER SYSTEMS DENS*-COTE base WOOD FRAMING 1. Horizontal Application--Apply Dens-Cote base hori zontally to framing so that ends fall on framing members. Nail with GWB-54 nails or equal, meeting ASTM C-514 having approximately Vi" heads. Length of nail shall be that which will provide at least 3k" penetration into studs. Space nails on both edge and intermediate supports 7" o.c. (maxi mum) on ceilings and 8" o.c. (maximum) on sidewalls keep ing 3/a'' from edges of base. Stagger end joints on opposite sides of partition. METAL FRAMING 1. Horizontal Application--Set G-P 25 gauge metal studs spaced 24" o.c. into G-P floor and ceiling track. Apply DensCote Base (Vz" or Va") using 1" self-tapping sheet metal screws and a power driven screw driver. Space screws vertically 12" o.c. (max.) on edge keeping 3/a" (min.) from the edge. Stagger end joints on opposite sides of partition. DENS-COTE" OVER MONOLITHIC CONCRETE To insure an adequate bond, a bonding agent conforming to ASTM C-631-68T should be applied in accordance with manufacturers' specifications, prior to the application of Dens-Cote Plaster. DENS-COTE" OVER MASONRY BLOCK Apply in two coats. Trowel first coat on sufficiently to straighten wall, but do not trowel smooth. After first coat sets, trowel on second coat. DENS'-COAT one coat system Georgia-Pacific Dens-Cote one coat System fulfills its repu tation as a system that provides quality walls for either resi dential or commercial constructions. The Dens-Cote one coat System is used whenever a strong durable finish with maximum speed and minimum material is desired. One ap plication of only 3/32' minimum Dens-Cote Smooth Finish (or Textured Finish) over Dens-Cote gypsum base is all that is needed to give lasting strength and beauty to any con struction. Although Dens-Cote Smooth Finish (or Textured Finish) is designed to be used over Dens-Cote Gypsum Base, it works equally as well over porous masonry block. APPLICATION--Add one bag (80 lb.) of Dens-Cote Smooth Finish' to 3V2 gal. of water with the mixer turning. Bring the mix to the desired consistency with additional water. A good working consistency will require approximately 4 gal. of water per bag (80 lb.). Mix until the material is lump free. Do not overmix. Dens-Cote Smooth Finish' normally has VA to IV2 hour setting time, so do not mix more than can be applied and finished in that length of time. Use 2V2" wide glass fiber mesh to reinforce all flat joints and angles or conventional paper wallboard tape. Use 1" x 1" minimum-perforated metal corner beads. Comer beads should be set to regulate plaster thickness at Va" maximum. The mesh must be embedded with Dens-Cote Smooth Fin ish' before the over-all application begins. If wallboard tape is used, use G-P Ready Mix Joint Compound or G-P Speed-Set Compound. At the same time, fill all metal corner beads. These areas may be allowed to set before the overall application is commenced. Trowel the first coat tightly over the entire wall or ceiling surface. This applica tion should be uniform about Vie' thick. As soon as the first coat has taken up (5-10 minutes), double back with a leveling coat, the total thickness ap plied should be 3/32" thick minimum. The final troweling must be completed before the set takes place. Maintain a temperature of at least 55" F. in the working area 24 hours before, during and after application. In hot weather reduce drafts and ventilation. Plan the work so that it proceeds in an orderly fashion from one end of the surface to the other. This will promote a progressively uniform takeup. DENS -COTE two coat system G-P Dens-Cote two coat System is for those who prefer the conventional finishes but desire modern speed and mini mum material. APPLICATION--Mixing and taping instructions are the same as outlined for the one coat system. Trowel a layer of Dens-Cote Base Plaster over the joint area. Trowel the Dens-Cote Base Plaster tightly over the entire wall or ceiling surface. This application should be uniform --about Va" thick. As soon as Dens-Cote Base Plaster has taken up sufficient ly, straighten wall but do not trowel smooth. Leave rough so that finish coat will key properly. Apply finish coat as soon as possible after base coat has set. Finish with lime putty and gauging for a conventional smooth finish, or use any sand float textured finish. If a hard durable smooth finish is desired use Dens-Cote Smooth Finish. `Finish coat may be smooth or textured as desired. FOR BEST RESULTS 1. Maintain a temperature of at least 55' F. 24 hrs. before, during and after application. 2. In hot weather reduce drafts and ventilation by covering door and window openings. DENS-COTE" SYSTEM PRECAUTIONS 1. Use only clean potable water with Dens-Cote Plasters. 2. Keep mixing equipment and tools clean at all times. 3. Do not mix retarders, accelerators, or any other ingre dient with Dens-Cote Base Plasters. 4. Keep Dens-Cote Plaster from freezing until it is set and dry. 5. Use ONLY G-P Dens-Cote Base with the Dens-Cote System. 6. Do not attempt to retemper Dens-Cote Base Plasters. Plan the work so that it proceeds in an orderly fashion from one end of the surface to the other. This will promote a progressively uniform takeup. DENS-COTE radiant heat piaster DENS-COTE BASE 1. Horizontal Application--Apply Vt" Dens-Cote base at right angles to framing so that ends fall on framing mem bers. Nail with GWB-54 nails or equal, meeting ASTM C-514 having approximately Vi" heads. Length of nail should be that which will provide at least %" penetration into studs. Space nails on both edge and intermediate sup ports 7" o.c. (maximum) on ceilings. May also be applied over resilient channels. NOTE: Firestop Dens-Cote Base shall be applied where fire ratings are needed. APPLICATION OF JOINT REINFORCEMENT Use 2Vz" wide glass fiber mesh or conventional paper wallboard tape and G-P Speed-Set Compound or ReadyMix Joint Compound to reinforce all flat joints and angles. The mesh may be stapled to the Dens-Cote Base. This assures positive keying of the Dens-Cote Radiant Heat Plaster to the mesh. SGP 0026886 F/7 Install cables and thermostats and make proper connec tions after joints are taped. Cables must be stapled tautly at a minimum of 2" apart. Use cables rated at 2.75 watts per lineal foot at 240 volts. FOR BEST RESULTS 1. Maintain a temperature of at least 55' F. in the working area 24 hrs. before, during and after application of DensCote plaster. 2. In hot dry weather, reduce drafts and ventilation by cov ering door and window openings. 3. Plan the work so that it proceeds in an orderly fashion from one end of the surface to the other. This will promote a progressively uniform takeup. CAUTION 1. Use only clean drinkable water. 2. Keep mixing equipment and tools clean at all times. 3. Do not mix retarders, accelerators, or any other ingre dients with Dens-Cote Radiant Heat Plaster. 4. Keep Dens-Cote Plaster from freezing until it is set and dry. 5. Use ONLY G-P Dens-Cote" Base for Dens-Cote Radiant Heat Plaster Application. 6. Do not attempt to retemper Dens-Cote. STORE IN A DRY PLACE APPLICATION OVER RADIANT HEATING CABLE 1. Trowel the first coat tightly over the ceiling using just enough Dens-Cote to fill in to the thickness of the Radiant Heat Cables. 2. After first coat has thoroughly set apply a leveling coat to cover the cables by at least Vs". (Total thickness ap proximately V*'). 3. When the surface has become firm it may be troweled smooth or floated and textured as desired. 4. The Radiant Heated Ceiling may be painted after it is completely dry. CAUTION: Do not use the Radiant Heat system to dry the plaster or decoration used on the ceiling. When using the system for the first time, turn thermostat to room temperature and raise tem perature 5 degrees each day until desired max imum operating temperature is reached. Specifications 1. Use G-P Dens-Cote Gypsum Base V2" or s/a ' thick by 4" wide with tapered edges and 8, 10' or 12' long. Apply Vz ' Dens-Cote Gypsum Base with ring shank nails 8'' o.c. for side walls and 7" o.c. for ceilings, to framing members spaced a maximum of 24" o.c. For fire resistive ratings and other special installations Vz ' and 5/s" Firestop Dens-Cote base is available. For these installations use a fastener, with a %" to Vs" penetration in wood framing members or fastener required for rating. 2. Use 2Vz" wide glass fiber mesh or paper wallboard tape to reinforce all flat joints and angles. Use 1" x 1" perforated metal beads for corners. For best results apply the mesh by embedding it with Dens-Cote Smooth Finish. This is ac complished by troweling a layer of Dens-Cote Smooth Fin ish over the joint area and pressing the glass fiber mesh into the Dens-Cote with a trowel. The mesh may be first stapled to the Dens-Cote Gypsum Base, if desired. In any case, the mesh must be embedded with Dens-Cote before the over-all application begins. Use G-P Triple Duty of Speed-Set Compound to embed paper tape. At the same time, fill all metal corner beads. These areas may be al- Georgiafecific ^ lowed to set before the over-all application is commenced. Corner beads designed for thin coat applications (not reg ular wallboard corner bead) should be set to regulate plas ter thickness at %2" minimum. Nail or screw corner bead to framing member. 3. Trowel the first coat tightly over the entire wall or ceil ing surface. This application should be uniform and about Vis" thick. 4. As soon as the first coat has taken up (5-10 mins.), dou ble back with a leveling coat, which will bring the total thickness applied to a minimum of %2". 5. fAfter the second coat has taken up (15-20 mins.), begin final troweling, use water if required. The final troweling must be completed before the set takes place, as evi denced by darkening of the surface. 6. Make joinings at angles. Ceilings should be done first, then sidewalls. 7. Coverage of Dens-Cote Smooth Finish is 14-16 square yards (Vu" thick) per 80 lb. bag. Base Plaster 1. Trowel the Dens-Cote Base Plaster tightly over the en tire wall or ceiling surface. This application should be uni form--about Vs" thick. 2. As soon as Dens-Cote Base Plaster has taken up suffi ciently, straighten wall but do not trowel smooth. Leave rough so that finish coat will key properly. 3. Apply finish coat as soon as possible after base coat has set. 4. Finish with lime putty and gauging for a conventional smooth finish, or use any sand float textured finish. 5. If a hard durable smooth finish is desired use Dens-Cote Smooth Finish. FOR BEST RESULTS 1. Maintain a temperature of at least 55' F. in the working area 24 hours before, during and after application. 2. In hot weather reduce drafts and ventilation by covering door and window openings. 3. Plan the work so that it proceeds in an orderly fashion from one end of the surface to the other. This will promote a progressively uniform takeup. 'specially formulated product, designated Dens-Cote Texture Finish, is recommended where swirl, sand finish, or other textured surfaces are desired. The same application procedure described for the smooth finishes should he followed with the exception ol the tmal coat. For the texture application, the fake up on the final coat will tie somewhat dependent on the type ol texture desired. In general, the liner the texture desired, the longer the take up time. In 10 case should the Dens-Cote be textured after it has commenced fo set. Texturing may he accomplished with a float, brush, sponge or other suilable tools. GYPSUM SALES OFFICES ATLANTA P.0. Box 13505, Station K Atlanta, Georgia 30324 CHICAGO P.0. Box 309 10450 Waveland Ave. Franklin Park, Illinois 60131 DALLAS 1800 John Connally Drive Carrollton, Texas 75006 DETROIT 126 E Hudson St. Royal Oak, Michigan 48068 KANSAS CITY 1445 Taney Ave. North Kansas City, Mo. 64116 LOS ANGELES 14750 Nelson Ave. City of Industry, California 91744 SEATTLE P.0. Box 286 12815 NE 178th St. Woodinville, Wash. 98072 WASHINGTON, D.C. 8121 Ardmore Ardwick Road handover, Maryland 20785 WILMINGTON Wilmington Marine Terminal P.0. Box 310 Wilmington, Delaware 19899 Lithographed in U.S.A. on G-P Kalamazoo 70 lb. Coronet enamel Gypsum Division SGP 0026887 900 S W Fifth Avenue Portland Oregon 97204 F/8 For rated fire resistive constructiun use G-P gypsum products with G-P Panclm g. See "Georgia-Pacific Guide to Products for Interior Paneling." GEORGIA-PACIFIC RAPID PLASTE1E SPECIFICATIONS FOR G-P/BESTWALL RAPID PLASTER SYSTEM-WOOD STUDS Gypsum Lath MATERIALS G-P/Bestwall's %" x 16" x 48" [16V%" x 48 West Coast) Type X gypsum lath or Vz" x 16" x 48" Type X Special Core gypsum lath meets the requirements of ASTM Designation C-37-66 and Federal Specifica tion SSL30c. The lath may be regular or insulating. Gypsum Plaster G-P/Bestwall's Special X Rapid Plaster meets all the requirements of ASTM C-28-63, except that the setting time when mixed with one part by weight of Standard Ottawa Sand shall be not more than three hours when tested in accordance with ASTM Procedure C-472. When tested for compressive strength with one part by weight of Standard Ottawa Sand in accordance with ASTM C-472, the compressive strength shall be not less than 1800 psi. Plastering Sand The plastering sand shall meet all the requirements of ASTM Designation C-35. Gauging Plaster G-P/Bestwall gauging plaster shall meet all the requirements of ASTM Designation C-28. Finishing Lime G-P/Bestwall finishing lime shall meet all the requirements of ASTM C-206-49 or C-6, whichever is used. Metal Trim Corner beads, casing beads and other metal trim shall be no lighter than .015 U.S. gauge steel, zinc coated, with a minimum one inch perforated flanges. Cornerite Cornerite shall be formed of metal lath or welded or woven galvanized wire fabric weighing not less than 1.7 lbs. per square yard with minimum outstanding legs of one inch, or 2" glass fiber tape may be used. Stripping Gypsum Lath Application Plaster Application Stripping shall be any of the materials specified for cornerite and shall be a minimum of 2" wide. APPLICATION The lath shall be applied horizontally using 4-114" blued iath nails per stud, per lath, with staggered vertical joints. All nails shall be driven so that heads are recessed slightly below the surface of the face paper, but without breaking the paper. Minimum gauge and weight of metal trim shall be as set forth in this specification and application is to be only over wood framing. The Special X Rapid Plaster shall be mixed with not more than one part by weight of plastering sand (six No. 2 shovels per 100 lbs.), and shall be applied with sufficient pressure to form good bond on the gypsum lath to a thickness of not less than Vb". This basecoat shall be allowed to set prior to applica tion of the finish coat. The finish coat shall be applied to a thickness of not less than 1/16 inch in accordance with ASA A42.1. Finish coat may be smooth trowelled, floated or textured. Note: The basecoat plaster is designed for hand application, but may be machine applied. Precautions: (1) Openings should be screened until plaster is completely set to prevent dryout and plaster should not be applied if the area to be plastered is below 55F. (2) Basecoat shall be left rough to assure adequate bond to the finish coat. ONE HOUR FIRE RESISTANCE PROVEN BY TEST CONDUCTED JOINTLY BY THE C.P.L.I.A. AND THE GYPSUM ASSOCIATION, MAY 25, 1967, USING Vz TYPE X LATH GP-67199 GEORGIA-PACIFIC / gypsum division SGP 0026888 A IA FILE NUMBER 21-A-2 RECOMMENDED SPECIFICATIONS Gypsum Plastering FOREWORD This specification incorporates portions of American Standards Association's Standard Specifications for Gypsum Plastering A42.1-1955 and has been published with the permission of the sponsors, The American Institute of Architects and American Society for Testing and Materials. This specification varies in format and organization from that in A42.1 to conform to the current recommendations of the Gypsum Association. Important areas of change revolve around proportioning of plaster to aggregate and the use of fines in trowel finishes. 1. Extent of Work: All plastering shall be done in accordance with the procedure as herein specified. This specification includes all labor, materials, services, equipment and scaffolding necessary to complete the project in accordance with the draw ings and specifications. 2. Work not Included: The following items are not intended to be a part of these recommendations: (a) Spray-on fireproofing (b) Spray applied decorative finishes (c) Wood furring and wood grounds 3. General Requirements (a) A uniform temperature of not less than 55 F. shall be maintained in the building for a period of seven days prior to the application of the plaster, during the plastering opera tion and after plastering, as required, until the plaster is dry. When temporary heat is required, proper measures shall be taken to insure that the heat is evenly distributed into all plaster areas. Deflection or protective screens shall be used to prevent concentrated or uneven distribution of heat on plaster areas near the heat source. Where required, heat shall be furnished by (insert name of the party who is to furnish the temporary heat here). (b) Ventilation shall be provided for drying the plaster during and after the application. Windows shall be kept open (cracked about 2 in.) at top and bottom to provide air circu lation. Where natural ventilation is absent, temporary air distribution systems or air conditioning units shall be used. (c) Where lath and plaster ceilings are located under roof constructions, the space thus en closed either with or without a vapor barrier and/or insulation, shall be permanently ven tilated in accordance with accepted engineer ing practice. The space above the ceiling shall be vented so that the ratio of the total net free ventilating area to the area of the ceil ing shall be not less than 1/150. Location of the vents shall provide positive ventilation. (d) Areas, such as doors, windows, etc., shall be properly closed in to prevent drafts. (e) Scaffolding shall be constructed and main tained in strict conformity with applicable laws and ordinances and in such a manner as not to interfere with or obstruct the work of others. (f) The work shall be properly coordinated with the work of other trades. (g) All products shall be delivered in their orig inal packages, containers or bundles bearing the name of the manufacturer and the brand. (h) The plaster and all other cementitious ma terials shall be kept dry until ready for use and shall be kept off the ground, under cover and away from damp walls or surfaces. (i) Metal products shall be protected against rusting. All materials shall conform to the latest edition of the following specifications: 1. Basecoat Plasters (a) Gypsum Neat Plaster, ASTM C28 (b) Gypsum Ready-Mixed Plaster, ASTM C28 (c) Gypsum Wood-Fibered Plaster, ASTM C28 (d) Gypsum Bond Plaster, ASTM C28 2. Gypsum Gauging Plaster, ASTM C28 3. Gypsum Molding Plaster, ASTM C59 4. Keene's Cement, ASTM C61 5. Lime for Finish Plasters (a) Normal Finishing Hydrated Lime (Type N), ASTM C6 (for plaster finishes where plaster is not in contact with poured concrete or concrete unit masonry) (b) Special Finishing Hydrated Lime (Type S), ASTM C206 (c) Quicklime for Structural Purposes, ASTM C5 6. Basecoat Plaster Aggregates (a) Sand, ASTM C35 (b) Perlite, ASTM C35 (c) Vermiculite, ASTM C35 Characteristics, properties or performance of materials or systems herein described are based on data obtained under controlled test conditions. The Gypsum Association makes no warranties or other representations as to their characteristics, properties or performance under any variation from such conditions in actual construc tion. Test condition details will be furnished by the Gypsum Association on request. SGP 0026890 SPECIFICATIONS GYPSUM PLASTERING 7. Aggregates for Finish Coats Aggregates for use in gypsum lime putty trowel finish, such as silica sand, perlite, etc., shall be graded within the following limits: PERCENTAGE RETAINED ON SIEVE SIEVE SIZE Perlite by Volume Sand by Weight . Maximum Minimum Maximum ; Minimum No. 20 (841 micron) ! 0 -- 0 '-- No. 30 (595 micron) 1 10 0 10 0 No. 100 (149 micron) 100 40 100 40 No. 200 ( 74 micron) 100 70 100 70 8. Water Water shall be clean, fresh, suitable for domestic consumption and free from such mineral or or ganic substances that would affect the set of the plaster. Water used to clean tools, that contains salt or alum, or other soluble salts, or from stag nant pools or wells shall not be used. 1. Proportions of sand, perlite or vermiculite to 100 lb. of gypsum neat plaster shall not exceed the following: PIASTER BASE OVER GYPSUM LATH Two Coat Work Basecoot SAND By Volume By Weight PERLITE OR <Cu. ft.) (lb.) VERMICULITE ...................................................... (Cu. ft.) Damp & Loose Damp & Loose 2Vi 250 2 Three Coat Work Scratch Coat Brown Coat or Scratch and Brown Coats 2 200 3 300 Vh 250 2 2 -- OVER METAL LATH Three Coat Work Scratch Coat Brown Coat or Scratch and Brown Coats 2 200 3 300 2V4 250 2 2 -- OVER UNIT MASONRY Two Coat Work Basecoat Three Coat Work Scratch Coat Brown Coat 3 3 3 300 3 300 3 300 3 *Where the plaster is 1 in. or more in total thickness, the proportions for the brown coat may be increased to 3 cu. ft. Note 1. The proportions in the preceding table are applicable for both hand and machine application of plaster. See manufacturer's instructions for application of machine applied plaster. Note 2. Use of an accurate device such as a measuring box or container to measure quantities is highly recom mended. Where such a device is not available, six No. 2 shovels of damp, loose sand may be considered as the approximate equivalent of 1 cu. ft. or 100 lb. 2. Gypsum Wood-Fibered Plaster (a) Gypsum wood-fibered plaster shall normally be used without the addition of aggregate. (b) Over masonry bases or over lath as a brown coat, sand, perlite or vermiculite aggregates may be used; the proportions shall not exceed 1 cu. ft. of aggregate per 100 lb. of gypsum wood-fibered plaster. 3. Gypsum Ready-Mixed Plaster: The term "readymixed" means that aggregate has been incor porated with the gypsum plaster by the manu facturer. It requires the addition of water only for use. 1. Plaster shall be of the following thickness when measured from the face of the plaster base to the face of the finished plaster surface (allowing approximately % G in. to l/8 in. for finish coat). (a) Metal Lath ... % in. minimum (when meas ured from the back of the lath, excluding riblath, thickness shall be % in. minimum). (b) Gypsum Lath . . . V2 in. minimum. (c) Unit Masonry ... % in. minimum (except gypsum tile, % in. minimum). (d) Monolithic Concrete (1) Walls ... % in. maximum. (2) Ceilihgs . . . % in. maximum. (3) Where greater thicknesses are required, metal lath shall be firmly attached to the concrete prior to the application of the plaster. 2. Plaster Grounds (a) Metal grounds, screeds, etc., shall be furnished GYPSUM ASSOCIATION SGP 0026891 3 and installed by the (lath) (plaster) contractor. (b) Plaster screeds shall be applied by the plaster ing contractor. (c) Wood grounds shall be furnished and installed by others. 1. Surfaces that are to receive plaster shall be care fully inspected before the plaster is applied thereto. Surfaces that are not satisfactory for plastering shall be called to the attention of the general contractor and architect. By proceeding with the plastering operation, the contractor ac cepts the responsibility that the surfaces were satisfactory to receive the plastering. 2. All metal grounds, corner beads, screeds, picture molds, etc., shall be carefully examined to see that they are straight, plumb, level, square and true to the required angles before the plaster is applied. 3. Plaster shall not be applied to masonry or concrete surfaces that have been coated with a bituminous compound or other waterproofing agents. 4. Masonry surfaces exhibiting high suction shall be evenly dampened to provide proper suction prior to plastering. Allow sufficient time for surface suction to equalize. 5. Monolithic Concrete (a) Monolithic concrete surfaces to receive bond plaster shall be cleaned of all dust, loose par ticles and other foreign matter. Laitance and efflorescence shall be removed by washing with a ten per cent solution of commercial hydrochloric acid (muriatic acid) and water and then rinsed with clean water to remove all traces of acid. Grease and oil shall be com pletely removed. (b) Concrete surfaces shall have sufficient rough ness to provide a proper bond. If surfaces are not rough, they shall be hacked or brushhammered or a dash coat of Portland cement grout composed of one part cement to IV2 parts of fine sand mixed to a mushy con sistency shall be applied. The Portland cement grout shall be forcibly applied to the concrete surface, using a stiff fiber brush, with a whip ping motion. This coat shall be kept damp for at least two days immediately following its application and then allowed to dry. Before application of plaster, the surface shall be evenly dampened, if necessary, to provide proper suction. ic) The use of dressed (smooth) lumber, metal and plywood forms, oiled or greased forms, or vibrated concrete, produces concrete surfaces which are too smooth to receive plaster. 6. Grouting Metal Framing and Bases (a) Hollow metal bases, metal door frames and metal framed openings, when used for solid partitions, shall be fully grouted prior to lath ing. The grout shall be screeded approximately in. below the top edges of the base so as to form a center groove to permit the lath to extend below the top edge of the base. (b) Metal door bucks and framed openings in hol low steel stud partitions shall be fully grouted prior to lathing. Where basecoat plaster is flush with metal base, metal frames, etc., plaster shall be cut free from these metal sec tions before the plaster sets. The finish coat shall be grooved at this junction to prevent chipping. 1. If mixing is done in the building, waterproof pro tection shall be provided under the mixer, mixing boxes and water barrels. Mixer, mixing box and tools shall be cleaned after mixing each batch. When the mixer is used intermittently, a sufficient amount of water shall be added to clean the mixer after dumping each batch. This water shall be run in the mixer for a few minutes and then dumped. The mixer then will be clean, ready for the next batch. Partially set material shall not be re tempered or used. Frozen, caked or lumpy material shall not be used. 2. Hand Mixing (a) Gypsum Neat Plaster--(Aggregate required) Aggregate and plaster shall be mixed dry to a uniform color at one end of the mixing box, hoed into the water and thoroughly mixed to the proper consistency. (b) Gypsum Ready-Mixed Plaster -- (Aggregate shall not be added ) Plaster shall be hoed into the water and thoroughly mixed to the proper consistency. (c) Gypsum Wood-Fibered Plaster -- (Without aggregate) Plaster shall be hoed into the water and thoroughly mixed to the proper consistency. (d) Gypsum Wood-Fibered Plaster--(With aggre gate) Plaster and aggregate shall be mixed dry to a uniform color at one end of the box. hoed into the water and thoroughly mixed to the proper consistency (see section C-2). 3. Mechanical Mixing With the mixer in operation, the following pro cedures shall be followed: (a) Gypsum Neat Plaster (1) Put in the approximate amount of water. (2) If sand is used, add approximately half of the amount of sand. If perlite or vermiculite is used, add all of the aggregate. 4 SGP 0026892 SPECIFICATIONS GYPSUM PLASTERING (3) Add all of the plaster. (4) Add remainder of the sand aggregate. (5) Mix to proper consistency, adding water if necessary. (6) Dump the entire batch and use. (7) Clean the mixer. (b) Gypsum Ready-Mixed Plaster (1) Put in the approximate amount of water. (2) Add the plaster. (3) Mix to proper consistency, adding water if necessary. (4) Dump the entire batch and use. (5) Clean the mixer. (c) Gypsum Wood-Fibered Plaster--May be used with or without the addition of aggregate. (See section C-2b.) (1) When aggregate is added, the procedure outlined in section F-3a shall be followed. (2) When used without aggregate, the pro cedure in section F-3b shall be followed. G. 8ASF.COAT PLASTER APPLICATION 1. Three coat plaster application shall be used on the following constructions: (a) Metal lath, wire lath or paper-backed wire fabric. ( b) y2-in. gypsum lath attached to horizontal sup ports spaced more than 16 in. o.c. (c) Gypsum lath on ceilings attached by clips pro viding edge support only. (d) %-in. perforated gypsum lath on ceilings. 2. Three Coat Work (a) Scratch (first) coat shall be applied with suffi cient pressure to form good full keys on metal lath, wire lath, or wire fabric and a good bond on gypsum lath or masonry. Sufficient mate rials shall be used to cover the face of the lath and to allow for scratching or cross raking. (b) Brown (second) coat shall be applied after the scratch coat has set firm and hard, and shall be brought out to the grounds, straightened to a true surface without the application of water, and cross raked or scratched to receive the finish (third) coat. To insure full plaster thickness, plaster screeds should be applied to the scratch coat prior to the application of the brown coat. (c) The plaster shall be accelerated, if necessary, to provide a setting time of not more than four hours. 3. Two Coat Work (a) The base (first) coat shall be applied with sufficient pressure and material to form a good bond on the gypsum lath or masonry and to cover well. Then, before the plaster has set, and without raking its surface, material of the same proportion shall be doubled back to bring the plaster out to the grounds. Straighten to a true surface, without the application of water, and cross rake or scratch to receive the finish coat. (b) The plaster shall be accelerated, if necessary, to provide a setting time of not more than four hours. 4. Monolithic Concrete (a) Monolithic concrete walls and columns shall have a scratch coat of bond plaster, followed by a brown coat of gypsum plaster propor tioned 100 lb. of gypsum neat plaster to not more than 3 cu. ft. of sand, perlite or vermiculite, troweled into the scratch coat before it has set. The brown coat shall be brought out to the grounds, straightened to a true surface without application of water and be cross raked or scratched to receive the finish coat. (b) Monolithic concrete ceilings shall have a coat of bond plaster scratched in thoroughly, dou bled back and filled out to a true, even surface, without the application of water and be cross raked or scratched to receive the finish coat. 5. Solid Plaster Partition (metal lath--channel studs) (a) Solid plaster partitions with channel studs shall not be less than 2 in. thick and shall have a scratch, back-up, brown and finish coat. (b) The scratch coat shall be applied to the lath side with sufficient material and pressure to form good full keys, to cover well, and then scratched to a rough surface. Where tempo rary bracing of the studs is required, bracing shall be attached to the channel side of the partition and maintained until the back-up coat of plaster has set. (c) After the scratch coat has set firm and hard on the lath side of the partition, the back-up coat shall be applied to the channel side of the partition in not less than two coats. This coat shall adequately cover the keys of the scratch coat and the remaining coat or coats applied to bring the plaster out to full grounds. GYPSUM ASSOCIATION SGP 0026893 5 Plaster thickness shall be not less than y2 in. over the unlathed face of the channel studs. It shall then be straightened to a true surface, without the application of water, and cross raked or scratched, to receive the finish coat. id) After the back-up coat on the channel side has set, a brown coat shall be applied on the lath side over the scratch coat, brought out to full grounds, straightened to a true surface with out the application of water and be cross raked or scratched to receive the finish coat. (e) Plaster shall extend to the floor except where metal bases are used, in which case the plaster shall extend below the top edge of the metal base to the grout. All spaces between grounds shall be filled. Hollow metal door bucks shall be filled solid. (Note: see section E-6.) Wherever possible, plastering shall be commenced at the bottom of partitions. 6. Solid Plaster Partitions (metal lath--studless) (a) Studless solid partitions (metal lath and plaster) shall be not less than 2 in. in thick ness, and the plaster shall be applied in the sequence below and in the same manner as specified for solid partitions with studs. (Note: see section G-5.) (b) Where rib metal lath is used, temporary brac ing shall be attached to the rib side and the scratch coat shall be applied on the flat side first. Where diamond mesh (flat expanded) metal lath is used, the temporary bracing may be attached to either side, and the scratch coat shall be applied to the opposite side. (c) The sequence of application of brown and back-up coats shall be in accordance with one of the following alternate methods: (1) The back-up coat shall be applied on the braced side of the metal lath and shall be followed by the brown coat applied over the face of the scratch coat. (2) The brown coat (second) shall be applied over the face of the scratch coat, then the back-up coat shall be applied on the braced side of the partition. (d) Plaster shall extend to the floor except where metal bases are used, in which case the plaster shall extend below the top edge of the metal base to the grout. All spaces between grounds shall be filled. Hollow metal bucks shall be filled solid. (Note: see section E-6.) Wherever possible, plastering shall be commenced at the bottom of partitions. 7. Solid Plaster Partitions (gypsum lath--studless) (a) Studless solid partitions (gy-psum lath and plaster) shall not be less than 2 in. in thick ness and shall have a separate scratch, brown and finish coat on each side. (b) The scratch coat shall average % in. in thick ness with a minimum thickness of %6 in. at any point and shall be applied first to the side opposite the temporary bracing with sufficient pressure to form a good bond. A % in. scratch coat shall be immediately applied to the op posite side. These coats shall be scratched or cross raked to form a rough surface. (c) The brown coat shall be applied to the side opposite the bracing, after the scratch coat has set firm and hard and is partially dry. When this brown coat has set firm and hard and is partially dry, the temporary bracing shall be removed and the brown coat applied to the braced side. The brown coats shall be straightened to a true surface without appli cation of water and cross raked or scratched to receive the finish coat, allowing ylG to % in. on each side for the finish coat to bring the over-all partition thickness to not less than 2 in. (d) Plaster shall extend to the floor except where metal bases are used, in which case the plaster shall extend below the top edge of the base to the grout. All spaces between grounds shall be filled. Hollow metal bucks shall be filled solid. (Note: see section E-6.) Wherever possible, plastering shall be commenced at the bottom of partitions. 8. Solid Plaster Partitions (multiple thickness gypsum lath) (a) Studless solid partitions (gypsum lath and plaster, multiple thickness lath) shall be not less than 2 in. in thickness and the combined thickness of the base coats and finish coats on each side shall be not less than y2 in. The thickness of the separate coats and the sequence of plastering on each side shall be in accordance with the proprietary specifica tions for the system employed. (b) The scratch coat shall be applied with suffi cient pressure to form a good bond and shall be scratched or cross raked to form a rough surface. (c) The brown coat shall be applied after the scratch coat has set firm and hard and is par tially dry. The brown coat shall be straight ened to a true surface without application of water, and cross raked or scratched to receive the finish coat, allowing to % in. on each side for the finish coat to bring the over all partition thickness to not less than 2 in. (d) The plaster shall extend to the floor except where metal bases are used, in which case the plaster shall extend below the top edge of the base to the grout. All spaces between grounds shall be filled. Hollow metal bucks shall be filled solid. (Note: see section E-6.) Wherever possible, plastering shall be commenced at the bottom of partitions. 6 SGP 0026894 1. Gypsum-Lime Putty Trowel Finish (a) Gypsum-lime putty trowel finish shall be mixed in proportions of one part gauging plaster (cal cined gypsum) to not more than three parts of lime putty by volume. Note: This proportion is equivalent to 1 -100 lb. bag of gypsum gauging plaster to not more than: 4-50 lb. bags of hydrated lime, or 4.5 cu. ft. of lime putty, or 34 gal. of lime putty. (b) Where the basecoat plaster aggregate is perlite or vermiculite, a gypsum-lime putty trowel finish shall, in addition, contain fine aggregate such as silica sand, perlite or vermiculite in the propor tions of not less than V2 cu. ft. nor more than 1 cu. ft. per 100 lb. bag of gypsum gauging plaster used in the finish. This finish, containing aggregate, may also be applied to sanded gypsum basecoat if desired. 2. Prepared Gypsum or Lime Based Trowel Finish Note: Additional materials, such as sand, shall be added only in accordance with the manufac turer's instructions. 3. Keene's Cement-Lime Putty Finish Keene's cement-lime putty finish may be proportioned to obtain a standard hard, medium hard or extra hard finish as follows: (a) A standard hard finish shall be mixed in the pro portions of 100 lb. of Keene's cement to 100 lb. of dry hydrated lime. Note: This proportion is equivalent to 1 1100 lb.) bag of Keene's cement to: 200 lb. of lime putty, or lVk gal. of lime putty. (b) A medium hard finish shall be mixed in the pro portions of 100 lb. of Keene's cement to 50 lb. of dry hydrated lime. Note: This proportion is equivalent to 1 (100 lb.) bag of Keene's cement to: 100 lb. of lime putty, or 8-3/4 gal. of lime putty. (c) Extra hard finish shall be mixed in the propor tions of 100 lb. Keene's cement to 25 lb. dry hydrated lime. Note: This proportion is equivalent to 1 (100 lb.) bag of Keene's cement to: 50 lb. of lime putty, or 4'k gal. of lime putty. (d) Where the basecoat plaster aggregate is perlite or vermiculite, a gypsum-lime putty trowel finish shall, in addition, contain fine aggregate such as silica sand, perlite or vermiculite in the propor tions of not less than V2 cu. ft. nor more than 1 cu. ft. per 100 lb. bag of gypsum gauging plaster used in the finish. This finish, containing aggregate, may also be applied to sanded gypsum basecoat if desired. 4. Gypsum Sand Float Finish This finish shall be mixed in the proportions of 1 part of gypsum neat unfibered plaster to not more than 2 parts of sand, by weight. 5. Keene's Cement-Lime Sand Float Finish Sand Float Finish-mix 100 lb. of Regular Keene's Cement, 400 lb. of sand (4 to 5 cu. ft.) and 100 lb. of Hydrated Finish Lime (200 lb. or 17V2 gal. of lime putty). 6. Vermiculite Finish Coat (for use over vermiculite basecoat only). This finish shall be mixed in the proportions of 100 lb. of unfibered gypsum plaster to one (1) cu. ft. of vermiculite finish aggregate. 1. Gypsum Lime Putty Trowel Finish Lime to be mixed or soaked in accordance with the manufacturer's directions. Mixing on a Mortar Board (a) The proper proportion of lime putty, as specified in H-l-a, shall be placed on a mixing board and formed into a ring. (b) Proper amounts of water, gauging plaster, and aggregate if used are added to the center of the ring. The gauging plaster shall be soaked until wet. (c) Materials are then inter-mixed until all ingre dients are well dispersed throughout the lime putty. Mechanical Mixing (a) When mechanically mixing gypsum-lime putty finish, the water shall be put in first, then the dry lime (autoclaved) or the lime putty -- whichever is used, the aggregate, and then the gauging plaster, and mixed until uniformly blended. (b) Dump the entire batch and use. Clean the mixer preparatory to mixing the next batch. (c) The mechanical mixer may be a conventional plaster mixer, which has been cleaned carefully so as to remove all adhering material, or a high-speed mechanical mixer designed for this use. A heavy duty 'k in. electrical drill, with a paddle type agi tator, in combination with a clean metal drum of suitable size may be used. SGP 0026895 2. Prepared Gypsum or Lime Based Trowel Finish Mixing must be done with the high-speed mixer, or a paddle type, such as described in I-l-c -- Mechanical Mixing. (a) Put all but 1 to 2 quarts of the required mixing water in the mixer. Note: Starting with an insufficient amount of mixing water will seriously degrade mixing and application performance. (b) Add the prepared trowel finish and allow to soak for about 1 minute, then mix until thoroughly wetted. If preferred, the plaster may be added with the agitator of the mixer running. (c) Add additional water, when required, to bring to the desired consistency and mix to a uniform lump-free consistency. (d) Dump the entire batch and use. Clean the mixer preparatory to mixing the next batch. J. APPLICATION OF FINISH COATS 1. General (a) The finish coat shall be applied to a partially dry basecoat or to a thoroughly dry basecoat which has been evenly wetted, brushed or sprayed. The use of excessive water shall be avoided in the application of all types of finish coats. lb) Where the plaster finish is flush with metal base, door bucks, or metal window frames, etc., the plaster finish shall have a V-groove finish at such intersections. 2. Application (a) Gypsum-Lime Putty Trowel Finish (1) Gypsum-lime putty trowel finish shall be scratched in thoroughly, double-backed and filled out to a true, even surface. The thickness shall be 1/16 to 1/8 in. The finish shall be per mitted to draw up a few minutes and then it shall be well troweled, with water, to a smooth finish, free from blemishes or irregularities. Continue troweling until finish coat sets. (b) Prepared Gypsum Trowel Finish ID Prepared gypsum trowel finish shall be applied in accordance with the directions of the manufacturer. The thickness shall be 1/16 to 1/8 in. The finish shall be well troweled, with water, to a smooth finish, free from blemishes or irregularities. (c) Keene's Cement-Lime Putty Trowel Finish |1) Keene's cement-lime putty trowel finish shall be scratched in thoroughly, double-backed and filled out to a true, even surface. The thickness shall be from 1/16 to 1/8 in. unless the finish coat is to be marked off or jointed, in which case the thickness may be increased as required by the depth of the marking or joint. The finish coat shall be allowed to take up and then well troweled, with water, to a smooth finish, free from blemishes or irregu larities. Maintain in a damp condition until set. Id) Float Finishes ID Sand float finishes shall be scratched in thoroughly with a trowel to an even surface and then floated (wood, carpet, cork, rubber, or other type floats, depending upon the tex ture desired) to a true, even surface, free from slick spots or other blemishes. (el Acoustical Plaster and Colored Finishes (D These plaster finishes shall be applied in accordance with the printed directions of the manufacturer. 8 SGP 0026896 APPENDIX SGP 0026897 9 All work shall be performed in accordance with the requirements of the Gypsum Association's "Recom mended Specifications -- Gypsum Plastering" and American Standards Association A42.4, "Standard Specifications for Interior Lathing and Furring," except as modified below: 1. Lath and plaster shall be kept a minimum of % in. above the top of the tub or shower receptor. A cas ing bead or similar plaster stop is recommended. 2. Where the brown coat of plaster is to receive tile, it shall be brought out to the grounds, straightened to a true surface and troweled to a smooth, dense surface. Plaster shall be kept out of the space between the casing bead and the top of the tub or receptor. 3. If a finish coat of plaster is to be applied, mate rials and application of basecoat plaster and finish coat plaster shall be in confoimance with the above mentioned "Recommended Specifications-- Gypsum Plastering." 4. When mopped-in-place shower subpans are used, Portland cement plaster shall be used for the curb and floor. The curb shall extend at least 1 in. above the base course of tile. 5. Waterproofing of the plaster shall be accomplished by one of the following two methods: (a) With the flat edge of a trowel, a full %6 in. skim coat of an approved grade of tile adhe sive shall be evenly applied to the entire surface to receive the tile. Apply to the bot tom edge of lath and plaster and fill the cut out spaces around pipes, soap dishes, towel bars, etc. Allow to stand well beyond the normal "take-up" time, preferably 24 hours. The recommended adhesives for ceramic tile are those tested and found to comply with Commercial Standard 181-52. Particular at tention is called to a list of such adhesives as published by the Tile Contractors'Association of America. All have been tested by an inde pendent laboratory and found to comply with CS 181-52. After the skim coat has hardened, so that it cannot be grooved by the notches of the trowel, a bedding coat of the same adhesive is applied in the usual manner. The bedding coat shall extend down over the lip of the tub to form a water dam behind the bottom edge of the tile. (b) A waterproof sealer may be used in lieu of the skim coat of tile adhesive. Acceptable sealers shall be only those specifically made for the purpose, and compatible with the tile adhesive, such as certain rubber base seal ants. A heavy brush application of sealer is necessary. All edges of cut-outs for pipes, soap dishes, towel bars, etc., must be sealed--and then caulked with waterproof, nonhardening caulking compound. After the sealer coat has thoroughly dried, the bedding adhesive is then troweled on to receive the tile. The bed ding coat must be compatible with the sealer. The recommended adhesive for ceramic tile is one complying with CS 181-52. Gypsum plaster can be satisfactorily used in conjunc tion with radiant heating installations, either hot water or electric systems. However, certain precau tions must be taken to minimize the possibility of such things as cracking due to thermal shock, shadowing under pipes due to unequal rate of dry ing or calcination of the gypsum plaster due to overheating. Gypsum lath and metal lath shall be installed in accordance with the requirements of American Standards Association A42.4 "Standard Specifi cations for Interior Lathing and Furring" and plastering shall be in conformance with the Gypsum Association's "Recommended Specifications--Gypsum Plastering" except as modified below: 1. In systems where the heating elements are em bedded in or behind the gypsum plaster, the sur face temperature of the plaster shall not exceed 115 F. This condition shall be met by requiring the temperature of the heating element, in contact with the plaster, not to exceed 125 F. 2. Electric heating elements may be securely attached to lath, but hot water coils must be supported by the framing members and not the lath. 3. All inspections and testing of the heating system shall be completed before the application of the gypsum plaster. Do not use the heating system for temporary heating of the building during plaster ing operations. Portable heaters or ventilating units should be provided. 4. The heating system shall not be used or put into operation until the plaster is thoroughly dry. At this time, the temperature rise in the heating elements shall not exceed 5F. per 24-hour period until the maximum temperature of 125F. has been reached. 5. Application of Plaster (a) Only sand aggregated plasters shall be used. Perlite and vermiculite have far greater re sistance to heat flow and should not be used. (b) A minimum of % in. of gypsum plaster over the heating elements is required. The total plaster thickness shall not be less than % in. over gypsum lath and % in. over metal lath. (c) Where more than % in. total thickness of plaster is required over the face of gypsum lath, plastering shall be done by the three coat method. (d) Where the three coat method is used, the 10 SGP 0026898 scratch coat shall be thoroughly cross raked and shall dry at least one day before applica tion of the brown coat. (e) To avoid shadowing under the heating ele ments, the base coat shall be almost dry be fore the finish coat application. If the base coat is completely dry, it may be wetted APPENDIX down to reduce suction for the finish coat application. (f) Decoration of the finish plaster, including sizing or sealing, shall not proceed until the heating system has been test operated for a minimum of 24 hours. The system should then be turned off before and during decorating. Gypsum plaster may be used on ceilings of open porches, carports, or walkways, on soffits of eaves, or other exterior areas that are protected from direct exposure to water. MATERIALS AND APPLICATION Materials and application shall be in strict conformance with the applicable requirements of "Recommended Specifications -- Gypsum Plastering," published by the Gypsum Association, and American Standards Asso ciation A42.4. Adequate ventilation shall be provided for the space immediately above such installations. The ratio of the total net free ventilating areas to the area of the ceiling shall be not less than 1/150. Screening shall be not less than 8 mesh per in. Expansion joints shall be provided at a minimum of 20 lineal ft. or 200 sq. ft. of area. Where framing is spaced 24 in. o.c., use 1/2 in. gypsum lath and 1 in. No. 66 galvanized casing bead. Where framing is spaced 16 in. o.c., use 3/8 in. gypsum lath and 7/8 in. No. 66 galvanized casing bead. Insulating gypsum lath may be used. Gypsum basecoat plaster shall be used with sand aggre gate only. Application of basecoat and finish coat plaster shall be done only when the temperature during appli cation and set of the plaster is above freezing. DECORATION After the plaster is dry, paint with two coats of a good quality exterior paint, such as an acrylic paint. CAR PORT or PORCH Va' GYPSUM LATH -I' 1 ik y2" GYPSUM PLASTER -- 7/h" galv. STEEL CASING BEAD MASONRY WALL FRAME WALL GYPSUM ASSOCIATION SGP 0026899 n GYPSUM ASSOCIATION 201 NORTH WELLS STREET CHICAGO ILLINOIS 60606 1SOO NORTH HIGHLAND AVENUE HOLLYWOOD. CALIFORNIA 90028 SGP 0026900 Form IP 3 ( Revised 2 i Primed m U 5