Document D00NpbwZk8Nr08XOy57BBLRd

CEA NO. 1430 PROGRESS REPORT 1 AH NO. ! -------- DATE March 27, PRODUCT TITLE ' Aroclors ___Increas-.e Arcelor Capacity 1963 DISTRIBUTION CED SECTION MANAGER________ R. M. KOUntZ CED PROJECT MANAGER________R` PsterSOH DIVISION Organic PLANT Anniston ... V""'' ' DIVISION REPRESENTATIVE______ W . _F . T?f BS v_ ...-------.------------------------ O. R. Bailey J. M. Depp M. Dmytryszyn R. E. Emling F. W. Enoch F. J. Holzapfel R. W. Kaltenrieder F. P. LaBelle R. E. Lenz Russell L. Miller E~~ ifeg-r-oC. L. Parish A. B. Terry (2) W. J. Burkett R. R. Cook/R. C. Herman R. E. Howard ORGANIC DIVISION (General Office) C. E. A.nagnostopoulo P. G. Benignus w. A. M. KcEwen H. L. Minckler W. R. Richard f ... ANNISTON PLANT i l. V V, l.O. / W. B. Papageorgs H. L. Williams SCOPE Aroclor production facilities at Anniston will be expanded by the addition of`tankage for storage and for the preparation of blends, drumming facilities in a new building (to be expanded on another project, CEA 1452, into a product warehouse), new and larger flakers for solid Aroclors and for biphenyl in the same building, and packaging equipment for flaked products. Tank truck loading and a new track spur with tank car loading and unloading facil ities are included. DEFENDANTS EXHIBIT^ i-si-ov fey osvj *>2485 WATER_PCB-SD0000051379 productAroclors________________________________________ i rrptir.n Anniston, Title Increase Aroclor Capacity Dale Tabulated As Cf February 29, .1968 r.?A Ho. 14 30 AR Ko. Appicpriaiioii HS 1,400 ij Current Estimate MS 1,307 * ji Process Design, % Cc.n?lcte Dale 0? Estimate Expanded & Committed Spent This Month Dec err.be r 1967 MS 403 M S 86 Sjl,`5cii3!iica! Design, % Cra/ctciiConstruciien, % Complete i;E crtcnt-ej $ Coamitkd Scheduled ComplelicoTli Farm 7/63, Flatters 10/68 IjLi-akn ibrtpKver On Schedule? Tk , F arm 8/68 Due to Sewers jiCo.:Un>uiso "sripowor Alabama -- Last ibr.li) 80 65 - 26 12 8 This lb. 85 65 3 31 12 15 * 593,000 is being handled by CEA 1452.. warehouse building. SUMMARY; Sewer corrections are now complete. The tank farm has thus lest about 5 weeks, indicating August 196S completion. The flake r vendor strike is over and October start-up still seems possible. Tank farm design is basically done, and flaker-packaging design is in high geerr. Most plant comments are new reconciled. The 30% estimate is deferred to April to reflect recent decisions. Field Work: Now that the 24" process sewer is relocated, excavation for tank foundations has begun. Good progress on warehouse excavation was made. Tanks, pumps and some pipe supplies are on hand. Piping prefabrication will begin soon. Tank Farm Desiqn Piping drawings have been issued and alloy take-off made. The tieins at the manufacturing area have been identified and a general layout developed. Space is reserved for future porocell treatment columns and a solid Aroclcr line. Flaker-Packaginq Are a Our layout has been revised at the request of the plant to favor gravity flow of solids. Other alternates have been resolved and considerable effort can be applied to firm equipment design. De sign is generally behind previous schedules, but we still expect October start-up. vo R, W. Peterson Project Manager osV4 392486 WATER PCB-SD0000051380