Document Byv3QDzNg6J6xjX4be5GN9J2X
PAPE 1 TITLE: COPY: (Bold-face)
SUBHEAD: COPY:
SUBHEAD: COPY:
Convert To Therrainol For Dramatic Savings
When the need to modernize a heating system arises, you will find that Therminol liquid phase heating offers: * Superior operating efficiency. * Elimination of licensed boiler operators
in many cities. * Maintenance reduced by up to 80 percent. * Easy conversion and installation.
Operating Savings
The use of high temperature Therminol eliminates the need for system pressurization. A high temperature primary loop (see diagram below) 13 vented to atmosphere, and thus the heaters usually are not classified as pressure vessels. This in turn eliminates the need for a crew of licensed low pressure boiler operators, a major factor in the cost of many old systems.
Cut Maintenance Costs
Operation of the new plant 13 entirely automatic
except for preventive and operational maintenance
and system shutdown and startup. These operations
can be performed by the regular building maintenance
staff.
HOMS 077260
SUBHEAD: COPY:
SUBHEAD: COPY:
Easy Conversion and Installation
Installation basically involves replacing steam boilers with fluid heaters. A steam generator can furnish hot water during the conversion to minimize inconvenience to your building's occupants.
Each of the fluid heaters are connected to heat exchangers. These converters generate hot water for building heating and domestic hot water heating and steam for kitchen equipment, garage heating systems and the building ventilation. Two pumps recirculate the fluid between heaters and converters.
Space No Problem
All system changes can bo confined to the previous boiler room area. Existing piping and equipment for the secondary services, including building heating service pumps, domestic hot water pumps, and condensate receivers remain in place. Thus, your building's services can continue to utilize water and steam as before.
HONS 077261
River House Cooperative Apartments - Detroit
This system, which has been In operation for more than five years, provides an annual savings of $36,000 compared to the old steam system; $25,000 through the elimination of licensed boiler op erators and $11,000 through reduced fuel costs. The latter saving results from an increase in over all efficiency from 60 percent with the old system to 83 percent with the new, and from switching to gas firing.
Holy Cross Hospital - Detroit
The conversion of this 250-bed hospital addition to Therminol liquid phase heating yielded an annual savings of $40,000 in operating costs. This saving was estimated to pay for the cost of conversion in three years. Moreover, the improved efficiency of the system added additional savings through lower fuel costs. J. P. Noble, Detroit consulting engineer, received the first honor award for mechanical engineering in the 1968 awards competition of the Consulting Engineers Council of Michigan for his design of this Bystem.
MGNS 077262
AKHON CUTLINE This Monsanto office and laboratory building in Akron, Ohio, was the first to use a high tempera ture, non-pressurlzed, fire-resistant fluid system for all direct heat needs. These include re frigeration, pre-heat, re-heat, base-board, steam generation and hot water. The completely auto matic and unattended system utilizes conventional off-the-shelf heating and air conditioning hardware. Installation costs were $10.50 per square foot, or 13 percent of the total building cost.
HONS 077263
PAGE 3 TITLE: COPY:
Thermlnol For Heatlnp; And Cooling In Campu3-Type Buildings
In addition to high-rise structures, Thermlnol heating systems offer considerable savings for campus-type buildings. Ferris & Hamig, Inc., St. Louis consulting engineers, prepared a feasibility study comparing a conventional system with high pressure steam distribution to four varieties of Thermlnol systems.
The Monsanto office complex in Creve Coeur, Missouri, was. used as a blsis for comparison. This complex comprises a powerhouse and five office buildings totalling 425,000 square feet and including a cafeteria and kitchen.
Here's a summary of the five systems and their
comparative costs:
System
Description
Initial and Operating Cost*
1. High pressure steam distribution to the five office buildings; with steam pressure reduced in each building to 10 lbs. pressure. Low pressure steam was distrib uted to heating coils in the air
conditioning units.
A central electric motor driven centrifugal water chilling system with condensing water pumps and cooling tower would be installed in the powerhouse. Chilled water mains would be run parallel to the steam mains
in the tunnels with braches to the air conditioning units in each
building. '
.
$86,997
MOMS 07726*
2. Varies from No. I in that Thermlnol heaters replace pressure boilers. Thermlnol supply and return piping are used in the tunnel with branches to each building.
. '
At each building a booster pump
with a three-way valve would be
installed to reduce the temperature
of Thermlnol from 550 to about 275P
The Theraiinol would then be pumped to
heating coils in the air conditioning
units.
`
$82,555
The water chilling system would be the same as in No. 1.
3. This system is the same as No. 2
except that centrifugal water chillers
would be replaced by absorption units
in the powerhouse; the cooling tower
and condensing water pumps would be
increased to reject the additional heat
from the absorption units.
$83,514
4. This system varies from No. 3 in that individual absorption units will be Installed in each building. Con densing water from a central cooling tower and condensing water pumps at the powerhouse will supply condensing water through the tunnel to these units.
$94,806
5. This system varies from No. 4 in that Individual cooling towers and con densing water pumps would be in stalled in each building.
$77,476
* These costs do not include savings in labor.
The report's conclusion: for this campus, application,
a Thermlnol heating system costs less than a con
ventional system using high pressure steam. And,
in addition to eliminating an operating engineer on
each shift, the Thermlnol system would offer; no
trap maintenance, no water treatment and lower liability
insurance rates. '
HONS 077265
TITLE: COPY:
Thermlnol PR-1
The Monsanto Thermlnol heat transfer fluids have been used for a number of years In a variety of heat transfer applications; from rubber rolling to food processing. Thermlnol PR-1 represents the best fluid for space heating systems.
Thermlnol PR-1 Is unique. It permits Installation of a non-pressurlzed system operating with a liquid which has no fire point and will not support combustion. Thennlnol FR-1 Is so fire-resistant, It has been listed with Underwriters' Laboratory.
Still another unique property of Thermlnol FR-1 Is Its unusual chemical Inertness. It Is among the most oxidation-resistant compounds known. This inertness prevents the formation of oxidation sludges if the hot fluid comes in contact with air. This extends the useful service life of the fluid; occasionally allows economies in design. However, Thermlnol FR-1 Is not Intended for use in open vessels but in properly vented, closed systems.
Chemically, Thermlnol'PR-1 is resistant to strong acids, mild alkalies and dilute solutions of strong alkalies.
RONS 077^66
Cicr-t~J
On the basis of animal toxicity studies,
THERMINOL FR may be considered only
slightly toxic from the standpoint of acci
dental massive skin exposure or accidental
ingestion. Similarly, single exposures to high
concentrations of vapors (when heated suffi
ciently to volatilize) or high concentrations
of decomposition products {if the fluid is
accidentally discharged into the fire chamber)
are not serious hazards because the irritating
character of such concentrations preclude vol
untary exposure.
.
Repeated or prolonged skin exposure should
bo avoided since THERMINOL FR acts as
a solvent for fats and oils of the skin. Re
moval of these natural, protective barriers
can lead to drying and chapping such os
occurs with exposures to paint thinners. More
important, THERMINOL FR may be ab
sorbed if it is allowed to remain on the
unbroken skin. For these reasons, we recom
mend that the skin be washed with soap and
water if there is contact. A skin burn resulting
from accidental contact with hot fluid should
be treated in the normal manner for any
thermal burn due to hot oils.
*-
Because of its low vapor pressure, there is no significant vapor inhalation hazard when THERMINOL FR is at room temperature. For example, there is no vapor exposure prob lem while transferring the fluid from its ship ping container to the heat transfer system. On the other hand, the vapors emitted by THERMINOL FR heated to elevated tem peratures are injurious on prolonged exposure. It is indicated that the "threshold limit value" or atmospheric vapor concentration which
cannot be safely exceeded (on a daily basis) is 0.5-1.0 milligrams of THERMINOL FR vapor per cubic meter of air in the workroom. In heat transfer installations, the fluid must be used in a closed system free from leaks with the expansion tank vended to the out doors. Accordingly, there should be little or no opportunity for workers to come In con
tact with vapors. .
HONS 077267
I
\
Do You Need More Information?
If the Therminol concept of heating system design Interests
you, let's tal-c some more. Our local Phemine-l fluid specialist can give specific answers to your questions about designing and specifying a I'herminol system. Or toll you more about high temperature, liquid phase heating in general.
Things like the states and municipalities that do not require ' a licensed boiler operator for such systems.
Just send in this card.
El Call for an appointment.
' Drop by any time.
'
Name
_____ ___
____
Title _
Company
Address
City, StateZIP
Phone
HONS 077268
PAGE 5 COPY :
SUBHEAD: COPY:
Total Therminol Systems in New Buildings
From open flame, to steam, to liquid phase
fluids. Unhappy with early direct-fired
heating, engineers centralized the fire and
used steam to bridge the gap. Now you can
bridge that gap more efficiently with new,
high temperature liquid phase heating.
Some examples of the ways others have
designed Therminol into their heating systems are detailed -below, ov'- "tVls
.
Therminol Versus Steam in an Eleven Story Hospital
Kaiser Engineers sought the most economical heating system for the Tower addition to an Oakland, Calif. Hospital. Consequently, they made a detailed analysis of steam versus Therminol for their 2^3,000 square foot expansion. Their findings: Therminol's initial installation' cost is $21,850 less than steam. The reduction in capital costs was due to the elimination of low and high pressure steam boilers, deaerator feed water heaters, condensate drainage system for absorption chillers, steam piping, related equipment and mechanical equipment floor space. * Therminol's operating cost is$8,000 less than steam; a 22 percent annual savings.
HONS 077269
The reduction In annual operating costs were due primarily to the anticipated added thermal efficiency of the Thermlnol System and the reduction In preventative maintenance and repair. It was projected that If licensed boiler operators had been required, as Is generally the case, an additional operating savings of approvlmately $25,000 per year would have been realized by utilizing the Thermlnol System approach. In addition to these outstanding cost savlngB, the study found Thermlnol: 1. Provided excellent response to building
load changes. 2. Created no venting problems. 3. Offered Increased safety because of the
non-pressure characteristics of the system. On this basis, a number of hospitals have used Thermlnol In their heating systems or Incorpor ated It into their designs. Diagrams detailing the design of these two systems are on the next page.
(The following page illustrates the blueprints for a steam and Thermlnol system.)
HONS 077270
1*> :
<3
'"(Lc-clIa* c
PAGE 5
Total Therminol Systems In New Buildings
COPY :
From open flame, to steam, to liquid phase
fluids. Unhappy with early direct-fired
heating, engineers centralized the fire and
used steam to bridge the gap. Now you can
bridge that gap more efficiently with new,
high temperature liquid phase heating.
Some examples of the ways others have
designed Therminol into their heating systems are detailed -beiow. o ^ "tVls
.
. SUBHEAD: COPY:
Therminol Versus Steam in an Eleven Story Hospital
Kaiser Engineers sought the most economical heating system for the Tower addition to an Oakland, Calif. Hospital. Consequently, they made a detailed analysis of steam versus Therminol for their 2^3,000 square foot expansion. Their findings: Therminol's initial installation cost is $21,850 less than steam. The reduction in capital costs was due to the elimination of low and high pressure steam boilers, deaerator feed water heaters, condensate drainage system for absorption chillers, stesm piping, related equipment and mechanical equipment floor space. * Thermlnol's oDerating cost is$8,000 less than steam; a 22 percent annual savings.
MONS 077271
The reduction in annual operating costs were due primarily to the anticipated added thermal efficiency of the Therminol System and the reduction in preventative maintenance and repair. It was projected that if licensed boiler operators had been required, as is generally the case, an additional operating savings of approvlmately $25,000 per year would have been realized by utilizing the Therminol System approach. In addition to these outstanding cost savings, the study found Therminol: 1. Provided excellent response to building
load changes. 2. Created no venting problems. 3. Offered increased safety because of the
non-pressure characteristics of the system. On this basis, a number of hospitals have used Therminol in their heating systems or incorpor ated it into their designs. Diagrams detailing the design of these two systems are on the next page.
(The following page illustrates the blueprints for a steam and Therminol system.) s'
HONS 077272
r
DATE
May 19, 1970
f{
JOB
Space Heating Brochure
V
P.V
TITLE:
Aut:
COPY:
A New Answer To Old Problems
JU
In Heating System Design
1
Scfcrw-p'cf
hjI h&K
^P^cr
Thermlnol high temperature liquid phase heating
offers new answers to questions you may be facing
In heating system design. Questions like:
* How do you lower the capital Investment for
heating/coollng equipment?
* How do you cut operating costs -- particularly
rising labor expenses?
* How do you save valuable floor space?
* How can your system meet rapid changes In
heat demand?
* How can heating system safety be maximized?
A liquid phase system designed around Thermlnol
heat transfer fluid -- In a new building or In
the modernization of an old one -- may be your
4 answer to many or all of these questions.
UX fb<.
U&k'*
hQ
1 .1 \ 2*Z)K* .<3-K>CLiu{Xj~`
,, C' l f 'nn
^ 2_
IL^J> p(Ko^>-
>
'S
- A 0*0 (S^tr
HONS 077273
n4^ :CM c
O'
** (jl /1M^
HmJ ^ludifctt
<^yyi Cw~ ^o-'y
?k
jf[) rv^1 '
AONS 0 7 777*