Document BypROQwNzO2v4mRMBj3eO7L0m
Tubes: Size, Length and Number Kewanee Firebox Boilers --
R*vt*4 D#wn-Dnft end
Kewanee Firebox Boiler
Riveted
Single-Pass
Up-Draft Brickset or
Portable Type K
Boiler
tubes
No. Du. Length
0 13-3"x 4' 6 " 1 17-3"x 4' 1 " 2 17-3"x 4' 8 " 3 17-3"x 5' 2 "
4 28-3"x 4' 8 " 5 28-3 "x 5' 8 " S 28-3"x 6' 8 " 8 39--3"x 6' 2 " 9 39-3''x 7' 2 "
10 46--3"x 6' 8 " 11 46--3"x 7' 8 " 12 46-3''x 8' 8 " 13 39--4"x 9' 1 " 14 39-4"x11' 1 "
15 4*-4"x10' I1/," 16 48--4/'x*12' V/," 17 2-4"x10' V/t" 18 62-4"x12' V/t" 19 82-4"X10' V/t" 20 82-4''x11' 7/,"
Not for Boilers Bulfl before 1911.
Kewanee Firebox Boiler
Riveted
Single-Pass
Smokeless Down-Draft
Brickset or Portable Type K
Boiler
TUBES No.DU. Length
104 28-3"x A- 8 "
105 28-3"x 5' 8 "
106 28--3"x 6' B "
107 39-3"x 5' 2 "
108 39--3"x 6' 2 '' 109 39-J"x T 2 "
110 46--3"x 6' 8 "
in 46--3 "x T 8 "
112 46-3 "x 8' 8 "
"113 39--4"x 9' 1 "114 39--4"x11' 1
115 4S--4'*x10' V/,"
116 48-A"x\2? V/t"
117 62-A"xVy V/t" 118 62-4"x12' v/t"
119 E2-4,'x10l V/t"
120 82--4"x11' V/t"
Net fer 8oiJr Built before 1918.
Kewanee Firebox Boiler Riveted Double-Pass Smokeless Down-Draft
DIRECT TUBES RETURN TUBES
Boiler No.DU. Length
No.DIa. Length
307 308 309
310 311 312
313 314 315 316
317 318 319 320
321 322 323 324
29-3 "x 2' 9 " 29-3"x 3' 7 " 29-3"x 4' 1 "
28-3"x V 6 " 2S-3"x 8'10/t" 28-3''x 9'10/t"
38--3"x 3' 1 " 38-3"x 3' 7 " 38-3"x 4' 1 "
36-3"x 9' 4J4" 36-3"x10' 4i/*" 36-3"x11' 41^"
28-4"x 4' V/t" 2B--4"x 5' V/," 28--4"x S'W/t" 28--4''x 6' 4 "
28-4"x11' 414" 28--4"x12' 4H" 28_4"x13' 8 " 28--4"x14' 8 "
38--4"x 6' 2/t" 38--4 "x 7' 8 " 46--4"x 6' A</t" 46--4"x 7' 2/t"
34-4"x14' 0 34--4"x 16' 0 46--4"x14' 8 46-4"x16' 0
" " " "
55--4 "x V V/t" 55--4"x V 7 " 68--4"x 8' 2 " 68--4"x11' 8 "
50--4"x15'11 50--4"x16'11 66--4"x18' 0 66-4"x22' 0
" " " "
Not for Boiler* Built before 1918.
Kewanee Firebox Boiler Riveted Double-Pass
Up-Draft
DIRECT TUBES RETURN' TUBES
Ecller No.Die. Length
No.Die- Length
407 29-3 "x 3' 7 " 28--3"x 7' 0/," 408 29-3"x 4' 0 " 28--3''x 7'11 " 409 29-3"x 5' 1 " 28-3"x 9' 6/t"
410 38-3"x 4' 6 " 36--3"x 8' 5'/*" 411 38--3"x 5' 1 " 36--3"x 9' 6/t" 412 38--3"x 5' 7 " 36-3"x10' 6/t"
<13 28--4"x 5'11'/," 28-4"x10'10H" 414 28--4"x 6' V/t" 28-4"x12' OH" 415 28--^'x V 91/," 28-4"x12` 9 " <16 28--4"x 9' V/," 28--4"x14' 7 "
<17 38--4"x 8' 6 " 34--4"x14' 0 " <18 38-4 "x 9' 7 " 34-4"x15' 7 " 419 46--4"x 8' 0/," 4S--4"x14' 0 " <20 46--4"x 9' V/," 46--4"x15' 7 "
<21 55--4"x 9' S/," 50--4"x16' 0 " <22 55-4"xir 0'-'," 50--4"x18' 0 " <23 6S-4"x IV 0 " 66--4"x 18' 0 " <24 68--4"x12' 6 " 66--4"x20' 0 "
Not for Boiler* Built before 1118.
Kewanee Firebox Boiler Riveted Double-Pass "500" Series Up-Draft
Boiler
DIRECT TUBES RETURN* TUBES
No.DU- Length
No.Dta. Length
524 526 528 530 532
534 536 538 540
542 544
38--3"x 6' 6H" 28--4"x 5' 6/t" 28--4"x 6' V/t" 34--4"x 7' 3/," 34--4"x 8' V/t"
36-3"x12` 0 "
Si-o^io-ion" 52-3 'Jt 12- 0H" 52-3"x12/ 9 " 52-3"x14' 7 "
43--4"x V 6/," 43--4"x 8' V/t" 49--4"x 7' 0/,"
49-4"x 8' 1/"
66--3"x 14' 0 66-3"x15' 7 82--3"x14' 0 82-3"x15' 7
" " " "
55--4"x 8' 6/t" 100-3"x15' 6 " 55--4"x 9'11>/," 100--3"x 17* 5 "
Kewanee Firebox Boiler Riveted Double-Pass "BOO" Series Up-Draft
Boiler
DIRECT TUBES RETURN TUBES
No.DU. Length
No.DU Length
832 833 834 835
836 837 838 839
840 841 842 843
46-3"x J'lOH" 46-3"x 4' 4H" 58-3"x 3' 9H" 58-3"x 4' 6//'
46--3''x 9'10 " 46--3"x1<yi0 " 58--3"x 9' 2H" sa-s'^iO" 5H"
66-3"x 5' 0 66--3"x 5' 9 85-3"x 4' 9 85-3"x 5' 6
" " " "
66--3"x1 V 0 ee-a^iy 3 83--3"x11' 3 83-3"x12' 6
" " " ''
104--3"x S' 0 104-3"x 6' 3 121-3"x V 3 121-3"x 8' 8
" " " "
103-3"x12' 0 103--3"x13' 9 120-3"x14' 9
120-3"x16' 8
" " "
"
"900" Series Down-Draft
Boiler
DIRECT TUBES RETURN TUBES No.DU Length No.Dll. Lertf.h
932 46-3"x 3' 3H" 46-3"x10' 1 " 933 46--3"x 3' 8/t" 46--3"x10*11 //' 934 58-3"x 2'IOH" sa-s-xio- 1 H" 935 58-3"x 3' 1H~ sa-s'-xio-ioH"
935 66--3"x 3' V/t" 66--3"x11' <H" 937 66--3"x 4'10/," 66--3"x 1 3' IV," 938 85--3"x 3*10 " 83--3"x 12? 2 " 939 85-3"x 4' 2/t" 83--3"x1 3' 0 "
940 104--3"x 3' 7 " 103--3"x12' 47, " 941 104--3"x 3' 8/," 103--3"x1 3' 0 " 942 121-3"x 4'10'/," 120--3"x14' 8 " 943 121-3"x 7' 5H* 120-3"x17' 9H"
"yj'f. WHEN ORDERING TUBES GIVE DATE OF BOILER OR SERIES NUMBER, AND CHECK ACTUAL LENGTHS AND NUMBER IN EACH TUBE NEST.
LENOTHS IN THESE TABLES INCLUDE 1 IN. FOR ROLLING AND BEADING. X'w.ntc BOiltr Corp. munio no respcmlblhty :0r tub oritrtd too lone or too ihcrt.
Tukeet Sti*,
e*4 Number
Kwim Firkn Beileri
Kewanee Firebox Boiler Weld + Rivet Double-Pa**
Kewanee Residence Boiler Welded Two-Pai* Tube*
Round Type "R"
BOTLER Coal- Oil
6029-5129 SO**-6133 50*4--51*4 6036-5136
SOU-5136 50*9-5139
5040-5140 6041--5141
6042-5142 6043-5143
5044-5144 5045-5145
DIRECT TUBES RETURN TUBES No. DU. Length No. DU- Length
30-3"* 4' 3(4" 49--3"x 3' 7(4"
49-3"* 4' 7/," 49-3"* 5' 7*4"
80-3"* 9' 8 " 48-3"* V 7%" 48--3"x10* OH"
48-3"*11' 7 *
60-3"* 4*11(4'' 60-3"* 6' 1 /4"
62-3"x 6' 1/," 62-3"* 7' 4(4"
66-3"*10'11/i" 66-3"* 12* 7 "
76-3"*12- 7 !4" 76-3"*14' 4(4"
101-3"* 6'10(4" 98-3"*13'10J4" 101-3"* 8' 1(4" 98-3"* 15' 7(4"
122-3"* 8' 7(4" 106-3"*16' 1(4" 122-3"*1(r 1(4" 108-3"*18' 1(4"
BOILER Coa! - on
735-2735 1735 736-2736 1736
DIRECT TUBES 1 RETURN TUBES Ko.DLa. Length | No.DU- Length
4-4"* 17 " 5-4"* 19/j"
4-4"x 27 " 5-4"x 29 "
Square Type "R"
740-2740 741-2741 742-2742 743-2743
1740 1741 1742 1743
745-2745 746-2746 747-2747 748-2748
1745
1746 1747 1748
7-4"x V 6(4"
7-4"x r oh"
7-4"* 2* 6%" 7-4 * 3' OH"
10-4"x 3' OH" 10-4"* S' 6H" 10-4"* 4' 0%" 10-4"* 4' 6H"
7-4"x 2- 4(4" 7-4"* 2'IOH" 7-4"* 3' 4H" 7-4"* 3'1C(i"
10--4"x 3'10(4" 10--4"x 4' 4(4" 10-4"X 4'10(4" 10-4"* 5' 4(4"
'6000" Series Down-Draft
6027-6127 6028-6128 6029-6129 6030-6130 6031-6131 6032-6132
6033-6133 6034-6134 6035-6135 6036-6136
6037-6137 6038--61U 6039-6139
6040-6140 6041-6141
6042-6142 6043-6143
6044-6144 6045-6145
30-3"* 2* 2H" 30-3"x 2* 9(4" 30-3"* 3' 2(4" 40-3"x 2- 7%" 40-3"* 3' 2H" 40-3"* 3' 7H"
49--3"x MOH" 49-3"x 3' 4(/," 49-3"* 3' 9(4" 49--3"x 4' 5 "
60-3"x 3' 2 " 60--3"x 3*10(4" 60--3"x 5' 4(4"
82-3"* 4'11J4" 82-3"x 6' 3'/,"
101-3"* 6' 1(4" 101-3"* 8' V/,"
122-3"* 8' 5(4" 122-3"* 10' 2/,"
30-3"x 7' 9(4" 30-3"* 8' 6(4" 30-3"* 9* 6(4" 36--3"x 8' 8 " S6-3"x 9' 3 " 36-3"* 9'11 "
48-3"* 8'11 " 48-3"* 9' 7%" 48-3"* 10" 6(4" 48-3"*11' 2(4"
66-3"* 9'11%4" 66-3"x11' 0(4" 66--3"*12*11(4"
76-3"* 12' 9(4" 76-3"*14' 3(4"
98-3"*14' 5/," 98-3''*16'11 "
108-3"*17' 3H" 108-3"x19' 6 "
Kewanee Firebox Boiler
Welded
Single-Pas*
"G" Serie* Up-Draft
Boiler
TUBES No.DU. Length
Kewanee Type "C" Boiler Welded Two-Pas* Tube* Smokeless and Direct Draft
BOILER Coel - on
DIRECT TUBES RETUIIN TUBES Xo.DU. Length No.DU. Leagth
749-2749 750-2750 751-2751 752-2752 753-2753 754-2754 755-2755
1749 1750 1751 1752 1753 1754 1755
756-2756 1756 757-2757 1757 758-2758 1758
759-2759 760-2760 761-2761 762-2762
1759 1760 1761 1762
763-2763 764-2764
765-2765 766-2766
1763 1764
1765 1766
767-2767 768-2768 769-2769 770-2770
1767 1768 1769 1770
21-3"x 2* 6H" 21-3"* 2'11(/i" 21-3"* S'11/j" 21-3"x 4' 7H" 27-3''x 4' 2(4" 27-3"x 4' 10 (4" 27-3"* 5' 9(4"
35-3"* 5' 6/*" 35-3"* 6' 1(4" 35-3''* 6' 8/j"
48-3''* 5' 7(4" 48-3"* 6' 8H" 62-3"x 6' 1H" 62-3"* 7' 0(4"
70-3"* 7' 6(4" 70-3"* 8' 9(4" 82-3"x 7' 9(4" 82-3"* 8'10(4"
94-3"* 8' 7(4" 94-3''* 9'IIH" 124--3"x 8' 8 " 124-3"x10* 2 "
24-3"* 4' 2H" 24-3"* 4' 8(4" 24--3"x 5' 8H" 24-3"* 6' 5 " 30-3''* 5'11/j" S0-3''x 6' 7/," 30-3''* 7' 7 "
34-3"* 7' 3/," 34-3"x 7'10H" 34-3"* 8' 5H"
48-3"* T 6/," 48-3"* 8' 8 " 56--3 "x 8' 1(4" 56-3"* 9' 0 "
62-3"* 9' 8 " 62-3"*10'11 " 86-3"* 9'11(4" 86--3"x11' 0 "
92-3"x10'11 " 92-3"* 12' 3(4" 118-3"*11' 0 " IIS-S"*^ 6 "
G-23 C-28 G-32 C-36
G49 G-44 G-51
G-55 G-64 G-71
36-3"* 3' 9(4" 36--3"x 4' 8(4" 36-3"* 5' 8(4" 36-3"* 6' 7(4"
52-3"x 5' 0(4" 52-3"x 5'10(4" 52-3"* 6'10H"
66--3"x 5'11(4" 66-3"* T 0(4" 66-3"x 7*11 (4"
EXCEPTIONS FOR EARLIER STYLES
Boilers Prrvloue to Date: 8erlei
BOILER Cod Oil
12- 6-29 1-X 1-21-31 IX
12-22-32 1-X 12-22-32 1-X 12-22-32 1.x
750-2750 1750 759-2759 1759
756-2756 1756 757-2757 1757 758-2768 1758
DIRECT TUBES RETURN TUBES
No.Die. Length
No.DU. Length
21-3"* 3' yt-
48-3"* 6' 2%"
24--3"x 4' 9H" 48-3"x 6' 1(4"
40-3"x 4' 4H"
40-3"* 4'10(i" 40-3"* 5' 4(4"
44--3"x 6' 2 " 44--3"x 6' 8 " 44-3"x 7' 2 "
NOTE:
WHEN ORDERING TUBES GIVE DATE OF BOILER OR SERIES NUMBER, AND CHECK ACTUAL LENGTHS AND NUMBER IN EACH TUBE NEST.
LENGTHS IN THESE TABLES INCLUDE 1 IN. FOR ROLLING AND BEADING
EXCEPT ON RO.R--SO.R TUBE LENGTHS INCLUDE ONLY W TO 1".
Kevenee Boiler Corp. mumi no reepocelbllltr for tubee ordered loo long or too ehort.
n
TV DATA BOOK 1 TAB 1 X-D. 21 SP 4-M REPLACES 11-47
Tubes: Size, Length and Number KEANES, Firebox Boilers (Simplified Practice)
15 Lb., alto HI Prenure.
) Kewanee Firebox Boiler Riveted Double-Pass "500" Series Up-Draft
Boiler
DIRECT TUBES RETURN TUBES
No.DIa- Length
No.DI*. Ltorth
576 577 578 579
580 581 582 583
584 585 588
587 588 589 590
24-3"x3' 254" 24-3"x4' 254" 32-3''x3` 354" 32-3"x4' 0/,"
23--3"x 7' 8 " 23--3"x 8' 7/i" 30-3"x 7' 9 -
30-3"x r sy2"
42-3"x3' 6/," 42-3"x4' 3%"
53-3"x3' 4 * 53-3"x4' 2 "
39--3"x 7'11/j" 39-3"x 9' 3 " 50-3"x 9' 8 '' 50-3"x11' 4 "
68-3"x4` 3 68-3"x5'10 82-3''x5' 8
" " "
62-3"x11' 5 62-3"x13' 4 74-3''x13' 2
" " "
101-3''x5' 2'/,'* 101-3"x7' 0*4" 117-3"x7' 0 yx" 117-3"x8' 9/j"
87-3"x13' 0 " 87-3"x15'10y,"
108-3"x15'105i" 108-3"x18` 1'/,"
Kewanee Firebox Boiler Riveted Double-Pass "400" Series Up-Draft
480 481 482 483
484 485 488
487 488 489 490
24-4"x 5' 84" 24--4"x 6'11'/(" 28--4"x 5' 7/j" 28--4"x 6'10/,"
38--4"x 8'11 '/j" 38-4"x 9' ^Zt 46--4"x 711 "
55--4"x 8' 054" SS-i'-xlO1 8*4" 68--4"x 9'10 " 68-4"x12' 054"
20-*"x10' 2 " 20--4"x1 VIOJ/j" 28--4"x11'11 |/j" 28--4"x14' 0/j"
34-*"x14' V/," 34--4"x16' 7y2" 46--4"x15' 5 "
50--4"x1S'105V' 50-4"x19' 6 " 66-4"x18' 8 " 66--4"x2V 5 "
K ewanee Firebc x Boiler Riveted Double-Pass "300" Series Smoicele ss Down-Draft
376 377 378 379
24-3 "X 1'1054" 24--3"x 2' 8*4" 32-3"x 2' 1'/," 32-3"x 2- 854"
380 Hl.Pr. 42-3*x 2' 4 54*
380 381 382 383
24--4"x 4' 41/*" 24--4"x 5' 4 54" 28--4"x 4'lli/j" 28--4"x 6' 2 "
384 385 385
38--4"x 6' 4 38--4"x 8' 5 46--4"x T 4
" " "
387 388 389 390
55--4"x T 5*4" 55--4"x10' 0*4" 68--<"x 9' 2 " 68--4"x 11' 5 "
23-3"x 7' 4 " 23-3"x 8' 4 " 30-3"x T 65V 30-3"x 8' 4 "
39-3`x 7'llH'
20-4"x 9'11 i/j" 20--4"x1 V 8 " 28--4"x1 V i/2~ 28--4"x13' 4 "
34--4"x13' 6 34--4"x15'11 46--4"x14'10
" " "
50--4"x15' 3 i/j"
5O-*''x18'10y," 66--4"x18' 0 ' 66--4"x20' 9 "
Kewanee Firebox Boiler
Riveted
Single-Pass
Brickset & Type K Up-Draft
Boiler
TUBES No.DIa. Dearth
3- 3 K 4- 4 K 5- 5 K 6- 6 K
17-3"x 5' 2 " 28-3"x 48" 28-3"x 5' 8 "
28-3"x 6* 8 "
8- 8 K 9- 9 K 10-10 K 11-11 K 12-12 K 13-13 K 14-14 K
39-3"x 6' 2
39-3"x r 2
46-3"x 6' 8 46-3"x 7' 8 46-3"x r 8 39--4"x 9" 1
39-4"x11' 1
" * " " "
"
15-15 K -16 K
1718-18 K 1920-20 K
48-4"x1CX 1/," 4*-4"x12' V/," 62-4"x1(r 7/t" 62-4"x12" V/," 82-4"x 10* 1/," 82--4"x11' 7'/a"
Kewanee Firebox Boiler Welded Single-Pass "G" Series Down-Draft
Boiler
TUBES No.DIa. LanrtA
G-18 G-22 G-26
G--30 G-35 G-40 G--45
G-50 G--60
36-3"x V 5J4" 36-3"x 3' 5J4" 36-3"x 4' 354"
36-3"x 5' 354" 36-3"x 6' 4'/," 52-3"x 5' 054" 52-3"x 5'10y,"
52-3"x 6' 754" 52-3"x 8' 254"
Kewanee Firebox Boiler
Welded
Single-Pass
"P" Series Up-Draft
P-18 P-22 P-26
P-30 P-35 P--40 P--45
P-50 P-60
36-3"x 3' 3 36-3"x 4- 2 36-3"x 5' 0
3S-3"x 6' 0 36-3"x 7'. 1 52-3"x 5' 8 52-3"x 6' 6
52-3"x T 3 52-3"x 8'10
Kewanee Boiler Scotch Marine Type Welded "M-8000" Series
Boiler I
TUBES No.DIa. Lenf.h
M8173 M8174 M8175 M8176 M8177
23-3"x 6' 6*4" 23-3"x T 8*4" 37-3"x 6' 0 "
37-3"x 6'1154" 37-3"x 8' 05V'
M8178 M8179 M8180 M8181
M8182 M8183 M8184 M8185
53-3"x 6' 6 '/j" S3--3"x T 3'/*" 71-3"x 6' 8%" 71-3"x 7- 9*4"
89-3"x T B'/V 89-3"x 9' 0*4" 109-3"x 9' 4 " 109-3"x11 ' 3 "
M8186 M8187
M8188 M81B9 M8190
128-3"x1 V 254" ^S^'V^IO "
146-3"x14' 0 " 178-3"x14' 0 " 200-3"x13' 4*4"
Kewanee High Pressure
Portable
Riveted
"Scottie Junior" Series
Boiler
TUBES No. DIa. Lonpvh
HM 9 HM 15 HM 20 HM 25 HM 30
28-3"x 3' 6 28-3"x 5' 3 28-3"x T 0 36--3"x 6'11 36-3"x 8' 4
" " '' "
NOTE:
WHEN ORDERING TUBES GIVE DATE
or BOILER OR SERIES NUMBER. AND
CHECK ACTUAL LENGTHS ALSO NUMBER IN EACH TUBE NEST.
LENGTHS IN THESE TABLES INCLUDE 1 IN. FOR ROLLING AND BEADING.
Kem-aate Boiler Corp. aijumea do rejponeibJJity fcr lubej ordered loo Ion* or loo abort.
Tubes: Size, Length and Number Kewanee Firebox Boilers (Simplified Practice]
Kewanee Residence Boiler Welded Two-Pass Tubes
Round Type "R"
BOILER mm for 7734*7734 im for 0734*0736
DIRECT TUBES No.DIa. length
RETURN TUBES No.DU. Leant)
--1733 734-1734,1 X
733-1735,4A5X 6X
73S-1736,4ASx
CX ___ 1737.1 X
4-3 " x 13 /, "
4-4 4-4 5-4 5-4
5-4
x1'S " *x1'5 "X17 -x17 " "x2'9/i"
4-3 "xl*/, " 4-3/,"x2' 0 4-4 "xZ 3 ' 4-4 "xZ 4/,'
5-4 "xZ 4H"
5-4 -x2* 6H" 5-4 *'x3' </,"
Square Type "R M
*m for 7740*77*1 Mme for 0740*0741
740-1740 741-1741 742-1742 743-1743
745-1745 746-1746 747-1747 748-1748
7-4 "xl-6%-
7-4 "x2'0K" 7-4 "xZW
7-4 "x3`OJ4"
10-4 10-4 10-4 10-4
"x30&" "x3'6%" "x4'0?4" "x4`6U"
7-4 7-4 7-4
7-4
"xZ 4H" "X2-10H" "x3` 4H"
"x3'10H"
10-4 10-4
10-4
10-4
"xS-lOH'' "x4' 4^"
"x4'10H"
"x5' 4H"
Square 83 "R"
83R1 83R2 83R3 S3R4
83R6 83 R7 83RB 83R9
1S-2/,"x1'6%" 16-2/,''x2'0i4" 16-2/,"x2'6H" 16-2/,"x30%"
21-2/,"x3'0?4" 21-2/i"x3'6%" 21-2^,"x4-054" 21-2/,"x4'6%"
15-2/,"x2' 4H" 15-2/,"x2-10H" 15-2/, "x3' 4H" 15-2/,"x3,10H"
20-2/,"x3'10H" 20-2/,"x4' 4*" 20-2/,"x4'10H'' 20-2/,"x5` 4^"
Kewanee Type "C" Boiler Welded Two-Pass Tubes Smokeless and Direct Draft
BOILER
am* for 2773-2710 am* for 0771-0710 um for 27L73-27L10
DIRECT TUBES No.DJa. Lopth
RETURN TUBES No.DJa! Lcnftb
1773-7 L73 774-1774-7 L74 77 5-1775-7L75 776-1776-7 L76
777-1777-7L77 77 6-1778-7L78 779-1779-7 L79
780-1780-7L80 781-1781-7L81 782-1782-7 L82 783-1783-7L83
784--1784-7L84 78S-7L85 786-7L86
47-1787-7 L87
788-1788-7 L83 789-1789-7 L 89 79O-179O-7L90
21-3"x 2* 5%" 21-3"x 2'11 H" 21-3"x 3' 5H" 21-3''x 4' 4 /"
27-3"x 4' 2Vi" 27-3"x 4'10Vi" 27-3"x 5' 5%"
35-3"x 5' 6/4" 35-3"x 6' K" 48--3"x 5' 9%" 48-3-x r 1 "
62-3 "x 7' 3t" 70-3"x 7'10Ji" 82-3"x T 2>i* 82-3"x 8' S%"
94-3"x 9' By," 124--3"x 9' 1/4" 124_3"x1CM0/4"
24-3"x * 2%" 24-3-'x V 8%" 24-3"x 5' 2y," 24-3'x 6' 1/,"
30-3"x 5'11 /," 30-3 "x 6' 7/," 30-3"x V 3 "
3-3"x 7' 3/," 34--3"x 8' S%" 48-3"x T 9 " 48-3"x 9' 0/4"
56-3"x 9' 3H" 62-3"x10' OV' 86--3"x 9- 4/,86-3"x10' 7/,"
92-3"x1? 0/," 118-3''x1 V 5/4" 118-3"x13` 2/4-
Kewanee Firebox Boiler Weld -J- Rivet Double-Pass
"5000'' Series Up-Draft
BOILER CoaJ - on
DIRECT TUBES No.DIa. Lccpth
RETURN TUBES No.DIa. Lcoptb
5076-5176 5077-5177 5078-5178 5079-5179
80-3"x1'11 30-3"xZ 8 30-3"x 3' 1 30-3"x3' 6
" " * -
5080-5180 5081-5181, IX
2X A Up
5082-5182 5083-5183
40-3"x3' 8% 49-3"x3' 14" 40-3"x4' 7
49-3"x3' ay," 49-3"x4' ty,"
5084-5184 5085-5185
60-3"x4' 9," 60-3"x6' 6/4"
5086-5186 5087-5187
78-3"xS' ty," 78-3"x6' 9%"
5088-5188
97-3"x6' 3H"
5089-5189 5090-5190
116-3"x7' OH" 116-3"x8' 9H"
30-3"x V 4
30-3 "x r 1
30-3"x 8' 0
30-3"x 8-11
" " " "
36-3"x 8' 8 "
48-3"x 8' 1 "
se-a'xio' oy,"
48-3"x1Cr 0 " 48-3-xlV 8 -
60-3"x11'11/," 60-3"x14' 0 "
78-3"x13' 0/," 78-3"x14' 7/,"
98-3"xl5' 1/,"
108-3"x15'10/," 108-3"x18' 1/,"
"6000" Series Down-Draft
6077-5177 6078-6178 6079-6179
6080-6180 6081-6181 6082-6182 6083-6183
6084-6184 6085-6185 6086-6186 6087-6187
6088-6188 6089-6189 6090-6190
30-3''x1' 9t" 30-3"xZ 3H" 30-3"x2' 9y,"
40-3"l2'10%" 40-3"x3' 7%" 49-3"x3' 41/t" 49-3"x4' 2/"
60-3"x4' 4y,"
60-3"x6' 0%" 78-3"x5' 1%"
78-3"x6' *y,"
97-3"x5'11H" 116-3"x6' 8/,"
5/,'
30-3"x T 2,"
30-3-X T ty," 3''x 8' 7 "
36-3"x 8' 6 " 36-3"x 911 " 48-3"x 9' 7/," 48-3"x11' 3/,'
60-3"x11' 6/," 60-3-X13' 6/,' 78-3"x12' 7/,' 78-3"x14' 2/,-
98-3"x14' 9/," 108-3"x15' 6 " 108-3"xir 9 "
NOTE' W C-
WMEN OROERINO TUBES CIVE DATE OP BOILER OR SERIES NUMBER, AND
CHECK ACTUAL LENGTHS NUMBER IN EACH TUBE NEST.
ALSO
LENGTHS IN THESE TABLES INCLUDE 1 IN. FOR ROLLING AND BEADING. . . . EXCEPT ON RO.R--SQ.R--JR BOILERS LENQTHS INCLUDE
Kiv4J>m Boiler Corp. aueaumea do rwpooalbllliy for tuba ordered too lo&p or too abort.