CHAPTER 49
1946 Guide
important enough to justify the omission of ventilation from certain
spaces which have only small heat gains and do not require fresh air for other purposes.
The relation between supply and exhaust ventilation depends on the type of space, and the space's relation to the weather. In any case, it should be remembered that positive means for supply and exhaust must always be provided. Where natural ventilation is anticipated, infiltration' and exfiltration via .open doors, windows, etc., cannot always be con sidered adequate for this purpose.
In addition to the ventilation requirements, but closely related to and
usually forming an integral part of the study, is the manner in which
heating shall be furnished for cold weather conditions. In all spaces
which are provided with mechanical supply ventilation, where heat is also
required, the simpler method and most economical from standpoint of
weight is that in which duct type or blast heaters are fitted in the venti
lating systems. Where this type of heating is furnished, convectors.or
radiators should be provided for spaces requiring heat but not furnished
with mechanical supply ventilation. The most satisfactory arrangement
for this method of heating, except where individual space -control is
essential, is zone heating. To accomplish this, the ventilation supply
system, with the fan operating at slow speed (usually about 50 to 70
per cent delivery) passes the air over a preheater which raises the air to a
temperature of about 40 to 60 F. This preheated air is then passed
through the system and thence through one or more reheaters which are
located in the ducts and so arranged that each serves a group of spaces
which possess the same or similar heating requirements. It may be
necessary to slightly revise the individual space air quantities, which have
been determined on the basis of summer" cooling, in order to bring them
in line with the reheat or delivery temperature. In some cases central
heating is used. By this arrangement all the air needed for heating is
passed through the preheater and reheater fitted in series. This system
has the disadvantage of affording poorer thermostatic control and cruder
heating properties. In all installations of duct type heaters, however,
-.'cure must be taken in the first stage of heating (preheater) to provide
protection against freezing, either by heater design or compensating auto
matic valve control. Of course, many of the usual combinations or
variations of duct type and convection or radiant heaters may be used
with varying degrees of satisfaction, depending on basic design require
ments such as weight and space limitations and economic justification for
refinements.
.N
REQUIREMENT FOR VARIOUS TYPES OF SPACE
In the paragraphs which follow the most important considerations are given for the treatment of the various spaces, but the resulting quantities of air should in all cases be checked with those shown in Table 1.
Machinery Spaces
The prime purpose of machinery space ventilation is to maintain a habitable temperature for the operating personnel. Of secondary impor tance is the necessity for preserving temperature conditions satisfactory for the successful operation of machinery, particularly of that designed for certain maximum ambient temperatures. High dissipation of heat,, from high/temperature steam equipment or from high powered electrical installations, make it more practicable to use spot cooling of working
Marine Heating and Ventilation
881
Table 1. Typical Heating and Ventilation Practices for Ships
Space ..
Type op Ventilation
Sup.
Exh.
Toilets and Showers. Chart House----------------------
Passenger & Officers Qtrs.
Office & Similar Spaces___
Mess Rooms...................... .
Nat. Mech.
Mech.
Mech.
Mech.
or Nat. Mech. Mech.
or Nat. Mech.
or Nat. Mech. ; or Nat. Mech. or Nat.
.Type
of
Heating
Air Change Minutes
Remarks
H.B.a or D.Rb
D.R. , H.B. or D.R.
H.B. or D.R.
H.B. * or D.R.
H.B. or D.R.
5-6 3-4
5-6
4-6
5-6 Maybe' 4-6 exhausted
through Galleys and Pantries.
Dining Salons........................ Mech. Mech. or Nat.
H.B. or D.R.
Galley and Pantry.......... .. Mech. & Nat.
Deck Pantries (No.cook- Mech. ing Equipment).. ______ & Nat.
Stores Spaces (Adjacent -.Mech. to Living Quarters):____ or Nat.
Stores Spaces (Isolated Mech. Locations).......................... or Nat.
Hospital Spaces___________ Mech. Soiled Linens and Oilskin
Nat. Mech.
Group Berthing Spaces___ Mech.
CO* Bottle Space__________ Battery Room_____________ Laundry_____ _____________
Dry Cargo Holds......... .....
-.
Nat. Nat. Mech. r
Mech. or Nat.
or Nat.1 Dry Stores................ ............. Mech.
Gyro Room_________
Mech.
Passageways.......................... Nat..
Mech.
Mech.
Nat. or Mech. Nat. or Mech. Mech.
Mech. or Nat. Mech. or Nat. Mech. Mech. Mech.
Nat. or Mech.
or Nat. Nat. or Mech. Nat. or Mech.
Mech. Nat.
H.B.
H.B. or D.R.
......
H.B. or D.R.
H.B. or D.R.
H.B. or D.R.
D.R. H.B.
' H.B.
or D.R.
'v H.B. or D.R. D.R. ,
Engine & Boiler Rooms___
Misc. Machinery.........
Resistor Spaces, j__2____ Stair Wells............ ...........
Mech. or Nat. Mech.
or Nat. Nat. Nat.
Mech. or Nat. Mech. or Nat. Mech.
Nat.
......
'
D.R.
3-6
1-2
3-6 15-20 15-30 -4 / 15-20
6-10 3-6 10
2 1-4
20-30 2-6 6-10 3-6
_6_-8
`
1-2 2-4 10
May be exhausted through Galleys and Pantries. Tempered air Sup.
-
Tempered air. Sup.
desired.
Exhausting or SuDDlving adjacent Quarters.
Same as passageways. Exh. at top.
H. B.--Hot Blast System. bD. R.--Direct Radiation.