Document ByZvNZRjwBO2nLVVDmqnrOVvw
i
rt
4PHYSICAl 'CHEMISTRY
V '-V
ANALYTICAL CHEMISTRY ^SPECTROSCOPY ^COMPUTER TECHNOLOGY STATISTICS
li&INSTRUMENT -RESEARCH
^,
r?
MONTHLY SUMMARY
n- toM Riv t/#
CONFIDENTIAL
INFORMATION
fNit document (oniiint cenl'denhel (nformetten which >i the property of Memento Compeny. Only thot* portion! of IN* document relevant to dulr euno ted 'iivwlunf v need to Inow my be etterpted for turn. the report mutt not be tent outude tNe cempenv without r.t*en approve! end the *v<ho' red '*'0 eriountebfe for ttt lefekeeping. eicerptinq or otherwite ditclotine of iti corrtenti end for *ti prooer d'teotel. Oertroy fhit report within two mentht
WATER PCB-SD0000019946
}
AROCLOR DEFENSE
As per our earlier agreement, the Wisconsin Research Alumina Foundation has submitted to us, for mass conf1rmation, five cleaned up extracts of composite fish samples taken from the Manlstee River (Michigan), Burns Ditch (L. Michigan), Manitowoc River (Wlsconsln) and the Kewaunee River (Wisconsin). The fifth sample Isa human biopsy fat specimen. All samples are estimated to conta1n ppm levels of PCBs along with other chlorinated hydrocarbons (DDT, DDD, DDE, BHC, and Die!dren).
An effluent sample taken from the fifth settl1ng pond at the ffcMC Central Foundry Division was analyzed for PCBs. The effluent con tained about 10 ppm of apparent PCBs which were not identical to either Aroclor 1242 or Aroclor 1248 but 11ke a mixture of the two. The alteratlon of the electron capture chromatogram could be due to the use of 1 248 as make up 1n reclaimed 312, some biological a 1tera tlon of 1242, or the presence of other electron capturing materlals In the sample. It was suggested that more samples be examined.
The initial bloloqlj^aXl^-jaLOOul ated river water (Meramec River)
degradation study of Aroc 1 ors 1221, 1
1248, and r2F4~Tra$ been
completed. The results 1nd1&&t&d_ that only Aroclor 1221 was
significantly degraded. Aroclors 1242, 1 24B, and 1254 we?e unaffected
aft^an exp.p.TunIlperjo.d of-Tnqfcfcjeeks .. A rgp^TT~wTl 1 be Issued .
The semi-continuous activated sludge degradation studies carried out 1n St. Louis confirm the rlver water results in that the major isomers 1n Aroclor 1221 were readily degraded. Additionally, some slight degradation of the lower chlorinated Isomers In Aroclors 1242 and 1248 was observed. The Aroclor 1221 and 1248 exposures have been dis continued to free two of the four semi-continuous units, being operated, to study the^effeet of biphenyl accumulation on the degradatlon of Arocl or 1 242 and theTegradatlon' of Arobrom 1228, a potentla 1 Aroclor substitute-. ..... ""
The appl1cabi11ty of ex tend 1ng the analytical techniques developed
to monitor Aroclors, Bromo Aroclor 1242, Arobrom 1228, and tri-tetra chlorobenzenes has been established. Only siight mod1f1 cations are -- necessary.
Samples of Bromo Aroclor 1242, Arobrom 1228, and two blends of Aroclor 1142 have been sent to Ruabon, U.K., for biodegradation studies.
Plans have been made to determine the feasibility of Incineration as
a means of disposing of non-reclaImable Aroclor and Aroclor conta1ning
waste. Three materials, Aroclor 1242, waste Intereen, and Aroclor 1260,
wl11 be tested at 1600F, and 2000CF. The tests will be carried out
by John Zink Company In Tulsa, Oklahoma on March 10th. Provisions have
been made to sample the stack gases for PCBs.
~
A discussion on the analysis of sediment and wa'ter samples for PCBs was held with W.G.K. personnel to determine 1f the plant 1aboratory could take over this function. Support analysis of W.G.K. plant samples will be continued until they are set up and prepared to do their own
analysis.
'
' COMPANY
TRAN 021706
CONFIDENTIAL
WATER PCB-SDOOOO019947
The Anniston plant analytical laboratory Is currently in the process of setting up the equ1pment to do their own PCB analysis. In support of this, one man week'was spent In St. Louis fami1iar izing Don Turner, who will be doing the analysi s at Anniston, wi th the analytical methods and equipment.
Yellow crystal 1ine solid recovered from W.G.K. process top oi1 scum was shown by IR to be an Inorganic compound, probably a metal halide. No chlorinated biphenyls or chlorinated terphenyls were detected.
GC support was given to the laboratory reformulation of distillation cuts of Aroclor 1130 1n an attempt to produce biodegradable species.
SKYDROL 500
IR analysis of hydraulic fluids from two Pan American test flights of Skydrol 500C showed that both were grossly admixed with Oronite Hi jet fluid. A/C 320 contained 10-12* Hi jet and A/C 321 contained 25-30* Hi jet.
Deposits in the brake system of an Eastern Airlines DC-9 are due to a s11icone polymer and not decomposltlon products of Skydrol 500. IR 5nalysis of sol Ids recovered by filtration of the fluid through a 1 /j mi 111 pore f 11 ter and deposl ts from the valve and f 11 ter showed that only a s11 leone polymer was present. The solids from the right hydraulic systern also contained an 1norganic carbonate. Skydrol 500 decomposition products were not detected.
Identification of FC-98, a purchased additive, was made for patent coverage. IR Indicates it is a perf 1 uori nated sulfonate- sal t con taining no hydrogen. Atomic absorption Indicates the principal metal present is potassium (6.2*). A hydrolyzed portion of FC-98 was analyzed by mass spectrometry using the heated solids probe inlet. The major component appears to be a cycl1c perf1uorosulfonic acid with a molecular weight greater than 400.
A BAC 111 feel valve spool in a system using Skydrol 500 A/B developed a white depos11. IR shows 11 to be a hydrated inorganic metal phosphate salt which 1s water soluble.
Deposit from a Braniff BAC 1-11 aircraft filter bowl was shown by IR to be an Inorganic^ metal phosphate.
The dielectric strength, power factor, dielectric constant, and AC resistivity of Skydrol 500C (Lot QL-2) and Skydrol LD were measured at 25 and 100C as a customer service for Lockheed.
THERMINOL 66
,
A. Gross and Company reported a 1ow bollIng liquid in their Therminol 66 system. As an aid to determining the source of this 1Iquid, a catch tank sample was characterized by GC/MS. It Is a mixture of
COMPANY CONFIDENTIAL
mN O2W07
WATER PCB-SD0000019948