Document ByV50jR1b4qNOKDZX0qBxMw8o
USCPA jr time subsequent to the cffcctht ' data of Mils Section, the owner or operator...
of an (otistc* source located In that count/ . ' or an/ count/ coot tguous to that count/ who ' would othbnfise be subject to the coopltance
date In subsection (b) shall comply with the requirements of . Sections 21S.641 throu9b 21S.603 within one year from the date or wedes Ignat Ion but in no case later than Oiecember 31.. 15(87..
(Source:: Adopted at 7'111. Reg.. 1244. effective Janwar/' 21. 1983.)
Section 21S.605 Compliance flan ..
a) The owner or operator of an emission source subject to Section 215.604(a) shall submit to the Agency * .compliance plan, pursuant to 3$ 111. Ada. Code'201. Subpart N. Including a project completion schedule where .applicable, no later than, for Section 215.601(a) and (b). April 21. 1983.
b) The* owner or' operator of an emission' source subject to Section 2t5:604(b) shall submit to the Agency a compliance plan, including a project completion schedule where applicable, no later than December 31.. 1986.
. c) The owiier or operator of an. emission source subject to Section 21'S:604fc) shall submit a compliance plan. Including a project completion'schedule within 90. days after the date of redes IgnatIon. but In'no case later than Oecember 31. 1986.
d) Unless the submitted compliance plan or schedule Is .disapproved by the Agency, the owner or operator of a facility or emission source subject to the rules specified In subsection.(a), (b) or (c) may operate the emission'source according to the plan and .schedule as submitted.
e) The plan and. schedule shall meet, the requirements of 35 111. Ada. Code 201. Subpart H. Including specific Interim dates as required In 35 111. Adm. Code 201.242.
(Source: Adopted at 7 III. Reg. 1244, effective January 21. 1983)
Section 21$.606 Exception to Compliance Plan
Coin-operated dry cleaning operations and dry cleaning facilities consuming' less than 30 gallons per month (360 gallons per year) of perchloroiethyTene are not required to submit or obtain an Agency approved compliance plan or project completion.schedule.
(Source: Adopted at 7 111. Reg. 1244, effective January 21, 1983)
Section 215.607
Standards for Petroleum Solvent Dry Cleaners
a) The owner or operator of a petroleum solvent dry cleaning dryer shall either:
1) Limit emissions of volatile organic material to the atmosphere to an average of 3.5 kilograms of volatile organic material -per 100 kilograms dry weight of
articles dry cleaned.-or
2) Install and operate a solvent recovery dryer. In a manner such that the dryer remains closed and the recovery phase continues Until.a final solvent flow rate
of 50 milliliters per minute Is attained.
b) The outer or operator of a petroleue solvent filtration system shall either:
1) Reduce the volatile organic material .content -In all filtration wastes to 1.0
kilogram or less per ISO kilograms dry weight' oT~afdcter'dr/'cleaned.1 before disposal, and exposure to the atmosphere. 1 or
2) rnstaTT and dperar* a carlrfdje
'
.filtration system, and drain the filter
cartridges In their sealed housings tor 8
hours or more before their removal.'
. (Sources Added.ot U Reg-2296. tUttU.ipr.Vl 3. 1987)
Section 215.608
Operating Practfees for Petroleum Solvent Dry Cleaners
*. a ,
_
In order to minimize fugitive solvent emissions,
the owner or operator of a petroleum solvent dry
cleaning facility shall employ good housekeeping
practices including the following:
a) General. Housekeeping Requirements
1) Equipment-containing solvent (washers,
dryers, extractors and filters) shall renin closed at- all times except during , load transfer and maintenance. tint filter and button -trap .covers shall remain.,closed-except when solvent-laden
material Is being renoved.
2) Cans, buckets, barrels and other containers of'solvent or of solwot-Jade*material shall be covered except when In
. . use.
3) . Solvent-laden material- shall be exposed
to the atmosphere-only for the mlntBum time necessary for load (ran'sfer.
b). Installation and operation of equipment:
1) All. cartridge filters shall be enclosed
and operated In accordance, with the procedures and specif ications recommended by-the-manufacturer-fbrtbe cartridge-
filter. After Installation, the cartridges, shall, be inspected..monitored
and maintained' In accordance with the manufacturer's -recommendations: and
2) Vents on containers for new solvent and for solvent-containtAg waste shall be constructed and maintained so as to minimize solvent vapor emissions.
- 127 -