Document ByQRjkvEd4BaGEMRnrkDKZwj
ACUTE TO XIC ITY TO FISH (M UM MICHOG)
TEST SUBSTANCE________________________________________________
Identity: A mixture containing perfluorooctanesulfonate, which may also be referred to as PFOS, FC-95, or as a component of FC-780. (1Octanesulfonic acid) (CAS # 2795-39-3).
Rem arks: The 3M production lot number was not available. The test sample is FC-780. Current information indicates it is a mixture of 0.5% PFOS, 14% diethylene glycol butyl ether, 76.95% water, 5.5% urea, 1.0% Sultone foamer, 1.15% sodium octyl sulfate, 0.8% polyoxyethylene monooctylphenyl ether, 0.05% sodium lauryl sulfate, and 0.05% tolyltriazole.
The following summary applies to a mixture with incompletely characterized concentrations o f impurities. Data may not accurately reflect the toxicity o f the fluorochemical component o f the test sample.
METHOD:________________________________________________________
M ethod: Not given Type: Acute static GLP: No Y ear com pleted: Not given. Species: Fundulus heteroclitus Supplier: Not given. A nalytical m onitoring: Not given. Exposure period: 96-hours Test organism age: Not given. S tatistical m ethods: Not given. T est conditions:
Dilution w ater: Not given. Dilution w ater chem istry: Not given. Lighting: Not given. Stock and te st solution preparation: Not given. Exposure vessels: Not given. Num ber o f replicates: Not given. Num ber o f daphnids per replicate: Not given. Num ber o f concentrations: Not given. W ater chem istry during the study: Not given.
R E S U L T S ________________________________________________________
Nom inal concentrations: Not given.
Elem ent values: 96-hour LC50 = >5000 mg/L
002495
Element values based on nominal concentrations. Rem arks: Testing was conducted on a mixture as described in the Test Substance Remarks field. The values reported apply to that mixture and not the fluorochemical proportion alone. CONCLUSIONS ________________________________________________ The 96-hour LC50 for FC-780 was >5000 mg/L. Subm itter: 3M Company, Environmental Laboratory, P.O. Box 33331, St. Paul, Minnesota, 55133 DATA QUALITY____________________________________ ______________ R eliability: Klimisch ranking = 4. Values are from a summary sheet only raw data not found. Study lacks description and records of the method followed. There is no characterization of the test substance purity and the study lacks analytical confirmation of the amount of fluorochemical proportion in the solution. REFERENCES____________________________________________________ Test was conducted by the Naval Research Laboratory, Fire Supression Section, Washington, D.C., 1977. OTHER________________________________________________ ;__________ Last changed: 6/26/00.
002496
Product Environmental Data
Environmental Laboratory Environmental Engineering and Pollution Control
900 Bush Avenue
PO Box 33331 St. Paul, MN 55133 612/778 5104
COMMERCIAL
CHEMICALS
DIVISION
3M BRAND COMMERCIAL GRADE APPF 6% CONCENTRATE FC-780
DESCRIPTION: Fire extinguishing agent.
APPEARANCE: Clear amber liquid.
COMPOSITION:
Percent by Weight
Diethylene glycol monobutyl ether (Butyl Carbitol*)
Water Fluoroaliphatic surfactants Organic surfactants Urea
14
77 <5 <5
6
USAGE: FC-780 is employed at a 6% level (e.g., 94 parts water to 6 parts FC-780) to extinguish fires involving liquid fuels and other liquid organic compounds.
AQUATIC TOXICITY:*
Test Organism
96-Hr. LCsn FC-780
Common Mummichog or Kille Fish (Fundulus heteroclitus)
>5,000 mg/1
BIODEGRADATION: *
Chemical Oxygen Demand (COD) Ratio of Twenty-Day Biochemical
Oxygen Demand to Chemical Oxygen Demand (BOD20/COD)
0.32 g/g 0.98
* As reported by the Naval Research Laboratory, Fire Suppression Section, Washington, DC.
Date:
6/11/82 (Supersedes 1/8/80)
These data are intended for the use of a person qualified to evaluate environmental data.
A ll statements, technical information and recommendations contained herein are of a general nature and are based on laboratory tests or literature information we believe to be reliable, but the accuracy, completeness or applicability to particular circumstances is not guar anteed. 3M makes no representation that the customer's use and disposal o f the product w ill comply w ith all applicable environmental laws, regulations and rules.