of andAmerican Society Heating Ventilating Engineers Guide7i935-- drops into the top of the boiler header through a boiler stop valve N drips are provided on this type of runout except a very small one whi h is sometimes installed on the boiler side of the stop valve. Fig. g shows type of boiler connection which is regarded as superior to that shown i* Fig. 5 and which is the type illustrated in the system diagrams in Chapte" 31. This type is similar to that shown in Fig. 5 except that the horizontal branches from the uptakes are connected into the main boiler runout, and the steam is carried toward the rear of the boiler. The branch to the building or boiler header is taken off behind the last horizontal boiler con nection. At the rear end of this main runout, a large size drip, or balance .pipe, is.dropped down-into the-boiler-returnror into-the top of the Hart ford Loop, which is described in a following paragraph. As a result, any water carried over from the boiler follows the direction of steam'flow Fig..5. Old Style Standard Boiler Connections Fig. 6. Approved Method of Boiler Connections toward the rear and is discharged into the rearjirip, or balance pipe, without being carried over into the system. Return Cast-iron boilers are generally provided with return tappings on both sides, but steel boilers often are equipped with only one return tapping. A boiler with side return tappings will usually have a more effective cir culation if both tappings are used. Check valves generally should not be used on the return connection to steam heating boilers because they are not always dependable inasmuch as a small piece of scale or dirt lodged on the seat will hold the tongue open and make the check useless. These valves also offer a certain amount of resistance to the returns coming back to the boiler, and in gravity systems will raise the water line in the far end of the wet return several inches3. However, if check valves are omitted and the steam pressure is raised with the boiler steam valve closed, the water in the boiler will be blown out into the return system with the accompanying danger of boiler damage. These objections are largely overcome with the Hartford return connection. *See method of calculating height above water line for gravity one-pipe systems in Chapter 31. 544 Chapter .32--Piping for Steam Heating Systems Hartford Return Connection In order to prevent the boiler from losing its water under any circumtances, the use of the Hartford Connection, or the Underwriters Loop, recominended. Fig. 7 shows this connection for both single boiler and two-boiler installations. By balancing the column of water in the loop _ainst the steam pressure, the water cannot be blown out of the loop whatever the relative pressure conditions in the boiler, steam lines, or return lines. This balancing is done by raising the return to approxi mately the normal water line of the boiler, looping it back to the boiler inlet and connecting the top.of.this loop. by. means of.a.balance pipe with--. the steam runout from the boiler. It is important that this balance pipe be connected into the boiler steam line on the boiler side of all valves. tTHESE HOCUS S0JLD BE IS MET IS HDCtlCIL USING IS FEW-, \ TUEHS IS POSSIBLE. THE. SIZES SHOULD PBEFEBIHY EE HOT SMIU.EB TRIM GIVEN W TIELE BELOW. GBATE IBEA PIPE SIZE 4 S_O_._F_EET 0C LESS- -- IW 4 SO. FEET TO BSQ IEET------ IX 15 SQ FEET 00. MOOE------------- 4' THESE 0DHNECHNS TO BE TAKEN OFF BETWEEN STOP iVUVESHFINfllNDBaiEB OPEBITInJ WITEB-LEVELS Fig. 7. THESE PIPES MW EE INV SIZE COUSIOEOED PBOPEB FOB FEEDING1 WLEBS AND LESS THIN SIEIM CONNECTIONS H TIBLE IBOVE. The Hartford Return Connection Theoretically, the top of the loop should be at the normal boiler water line but since this installation often causes trouble from water hammer in the top of the loop, this top is usually made 2 in. below the normal boiler water line to keep the horizontal pipe at the top submerged under all normal conditions. It is important that this top of the loop be made with the shortest possible horizontal pipe, a close nipple being employed. Sizing Boiler Connections Little authentic information is available on the sizing of boiler runouts and steam headers. Although many engineers prefer an enlarged steam header to serve as additional steam storage space, there ordinarily is no sudden demand for steam in a steam heating system except during the ^ heating-up period, at which time a large steam header is a disadvantage rather than an advantage. The boiler header may be sized by first com puting the maximum load that must be carried by any portion of the header under any conceivable method of operation, and then applying the same schedule of pipe sizing to the header as is used on the steam mains for the building. The horizontal runouts from the boiler, or boilers, may be sized by calculating the heaviest load that will be placed on the boiler at any time, and sizing the runout on the same basis as the building mains. The difference in size between the vertical uptakes from the 545