Document ByD5pZpnML6ydV7z12nnnJRr4

it 6 / I .* . Is no question that recovery can be effectively Increased in every major industry we now serve. If Monsanto does not assume or initiate this program for our own flults it will be done by another companyi i -' In the case of synthetic fluids, perhaps more so than other chemicals, the customer can, through improved or modified housekeeping procedures, recover synthetic fluids and most do net have to install a waste treatment facility. Each of our key iidustries is discussed separately with regard to feasibility of synthetic fluids recovery. Piecasting Waste treatment facilities are rare in this industry. The only area where treatment is found is for cutting oils and plating chemicals, where the plant machines and paints or plates the dlecast part. This market represents about 30^ of the 1000 dlecasting accounts in the United States, according to Detrex^Incorporated, the major supplier of degreasing chemicals and systems. The major products consumed by the diecaster are dlelubes (water or solvent base), lubricating oil {aid greases, cleaning solvent and hydraulic fluids. Hydraulic fluid (pydraul) usage is substantial at 20-50)5 of total fluids consumed in the plant, with larger diecast plants, l.e.,Johnson Motors using the smaller ratio of FH fluid to total chemicals. Although the amount of other products consumed is substantial there appears to be limited intermixing with the waste Fydraul. Dielubes are vaporized when contacted with the hot dieeast part and lubricating oils and greases are used in machining MONS 035182 9 outside or adjacent to the immediate diecasting area. Pydraul usage escapes Into four separate sources in the dlecast . plant.' These sources include bulk waste (major line breaks and spills) adhered to dieoast parts, water effluent .and through floor dry absorbent material. A diecaSter's "water effluent" is an open trench network in the plant floor that carries cooling water to the dlecast machine dies. This water is normally recirculated to a cooling tower with limited overflow to sewer. Table I displays results found by perscnal contacts at 9 different ' diecasting accounts. In all cases either the floor absorbent or the'water effluent represented 80-100# of the Pydraul consumed at the account. Those plants reporting nc Pydraul escaping into the water effluent have closed cooling water circulating lines. The . other accounts reporting escape to water have open accesses where liquids flow freely from the diecasting area directly into the water. In the case of Johnson Motors the machines are cleaned regularly with solvent and everything is flushed into the troughs. At Johnson Motors a total of 85-90# of their Pydraul consumption escapes directly into the water stream. Based on the above results and our knowledge of the diecasting market, several points ere Important: l) Of the estimated 1)00-500 diecasting shops using synthetic ".v., .................... ........ fii`/gvVesitt'dh^-'fl,Cfids'`:,dnly a"'small' percentage' hove open aoccss trenches where Pydraul contacts water directly. MONS 035183 10 Although a Email percentage, however, these accounts are the larger dlecasters (Johneor. Motors, Central Foundry, Leste,* Castings, etc.). 2) The diecaster Is concerned abcut pollution and all are anxious to maximize cost savings. We must expect that the larger volume cf fluid escaping into the stream will require the customer to provide adequate sumps/ponds or I virtually close off access to his water stream. The . logical choice for most is closing off access to insure complste sa'fety from tighter pollution laws. Thus, the majority of the diecasting industry would revert to . absorbent as the primary escape source for hydraulic fluids. Separate fluid analyses from the Interceptor pits of "sumps" of Johnson Motors, Lester Castings and Central Diecasting are reported in Table II. In all cases the Pydraul was found to be.of high purity. In all cases the Pydraul isn't being reclaimed. The pre sence of large amounts of solids in the Johnson Motors and Lester Castings samples as well as the 3C$ non-Pydraul content in the sump of Johnson Motors is felt, to be a direct result of housekeeping. Both the level of solids and the amount of contamination from oil, etc., can be controlled. Milt Tegethoff of Findett has indicated that of all the bulk waste and "samp" Pydraul forwarded to him by our customers over the past several years for reclamation all have been of reclalmable quality. In the few cases where analysis beforehand Indicated unacceptable fluid quality discussions with plant personnel resulted in fluid of reclalmable quality.' It is - MONS 03518* )1 Important to note that In cases where the level of solids is high a solvent extraction technique is required for effective Itydraul recovery. Solvent extraction techniques were successfully evaluated by Research on Pydraul-absorbent mixtures. This subject Is discussed separately. i'V-.v >' HONS 035185 FIGURE I Wisconsin Steel SCHEMATIC OF WATER FLOW-STEEL ACCOUNTS SAMPLE ANALYSIS recycle ' to ->t water flow cont rnuous caster Wheeling Steel, --^ | wate r flow V ft . j hot strip i mill Timken Steel </ Tube mill; #3 I I Tube Mill: ! #4 caste r ' recycl? to w . mill settling basin a, 2) scale pit i scale pit scale pit (2) i cooling {-tower ,,</ overflow to sewer I (1) j(Z) . HONS 0 3 5 1 8 6 (3) V to storm 1. Caster-bottom of pit 2. Settling basin-oottom 3. Cooling tower-top at recycle and overflow point 1. Scale from pit 2. Scale oit-top at re~y' and overflow point 104) settling pond V (5) ove rflow to stream 1. Sc 2. Flow from 9cale pit to pond 2. Pond-top floating oil 4. Pond-bottom sludge 5. Pond-overflow to stream 13 Steel Industry . Figure^! outlines the operations at Wisconsin Steel, Wheeling- Plttsburgh St<el and Timken Steel where Pydraul is currently bting used and where samples wore taken of the water and scale pit areas to analyze Tor pydraul content and recoverability. The results of these analyses are valuable because each process is different yet typical of high volume Pydraul consumption that comes in direct contact with i ater. The processes ana lyzed were a continuous caster, hot strip mill and two tube mills. In these hot steel operations hydraulic fluid leakages directly contact the cooling water. Oxidized steel solids (scale) settle from the cooling water in the scale or settling pits where residence times were as much as 1-8 hours. Cooling water flow rates through vary from 300-10000 gpm, depending upon operation and size of plant. Results of the pydraul analyses from Wisconsin, Wheeling and Timken Steel are reported on Table III. The high Pydraul content in the oastlng pit and scale pits equals almost the entire reported Pydraul usage at that plant even when using a conservative estimate for the amount of scale produced per day. The overflow from the pits contains minute quantities of Pydraul. The small amount of fluid and the presence of other chemicals pre cludes economical recovery using conventional absorptive filtration techniques, Pydraul in the overflow from the settling areas of HONS 035181 14 these steel companies ranged from less than one gallon per year to about 200 gallons per year at parts per million levels of 1 or less. Although Pydraul levels are too low for recovery, escape Is directly to the sewer which opens questions to pollution control. In the case of every steel company contacted during this study (total 6) waste treatment plants were either In existence or planned for the Immediate future. All plants follow essentially the same basic approach to treatment which involves: 1) Deemulsification and flotation of oils. 2) Skimming and concentration of oils both at the scale pit and clarifier areas. Oils arn then pumped to storage and either disposed of or reclaimed. 3) Chemical flocculation and clarification of solids and preclpltable salts and acids. 4) filtration of precipitated sludges. 5) Disposal of filtered sludges either by incineration, lagooning or land fill. The minute quantities of Pydraul overflowing from the scale pits Can thus be expected to end up in the sludge. The growing trend for sludge disposal is incineration due. to 'restrictions now being placed on land fills and private lagoons. For those operations using PR fluids in direct contact with the cooling water, the descaling area has been identified as the prime escape source. Economic recovery of the FR fluids from scale v;ould require solvent extraction. This process, although favorable for MONS 035168 15 diecasting appears impractical for the steel industry as: 1) Outside contaminates are high and unooutrollable. In I the case of Wheeling Steel the ratio of Pydraul to the other products consumed in their 80 inch hot strip mill | is about 1:2 Pydraul:kerosene solvent and 1:500 Pydraul: i soluble rolling oil. '. ' 2) The growing practice in the steel Industry is to sinter dredged scale from the scale pits. The by-product is reused in the steel making process. Sintering temper\tures are over 1000F. Indicating aihered fydraul is vaporl: sd at the sintering plant. A substantial amount of synthetic fluids are consumed in the steel Industry in equipment not in direct contact with water. For example, scrap chargers, increased use of hydraulically operated furnaces, CPE soaking pits fuel-air regulators, etc. Findett customers for reclaimed Pydraul have included Laclede Steel and Wisconsin Steel. It is reasonable and conservative to assume that at least 10-20# of the consumption from the primary Bteel producers is reclalmable. Fluid in these cases will come from leakage, spillage end mass line breaks. . MONS 035169 TABLE I PTDFAVL USAGE ESTIMATES-SELE CTED DECASTING PLANTS - Gallons/Year j Source - % Total usage Johnson Motors "Waukegan Lester Castings Bedford, Ohio Central Diecasting Chicago Pydraul. Usage 90, 000 Nr. Machines 100 Water Effluent 23-60%* Floor Absorbent Bulk 66-25% 2 . ?5% 12, 000 20 25-501'3 60-40% . <5 3, 000 18 --------->95X- <5 Diecast Flash 5-10% 5 Other --- -- .- Milwaukee Diecasting Milwaukee 3, 000 Carter Carburetor . St. Louis, Missouri 18, 000 4 Peat Mfg. Company Norwalk, California 7, 000 4 International Cast. Pro 3, 000 ducts, Gardena, Calif. .4 ITT General'Controls Clendalc, California 4 /Withrow Diecasting Hollywood, California 10, 000 3,300 22 48 18 .9 17 . 16 0 0 0 20 0 25 >90 <5 *. ' 70-80 - . 25-20 100 SO 100 "" '+ 75 "" 5 --* 5 ----. --' ' * * ---- **" ! 1. From actual water effluent sample analyses. 2. Absorbent solvent washed down water drains, thus effluent estimated @ 85-90% total usage. 3. Storm sewer sample. Total includes their estimate of 500-1000 gallons per year recovered from sump. 4. J. H. Davidson survey 5/70. w 06TSC0 SNOW TABLE II SALVAGE FLUID DUALITY-DIECASTING 40 Company Fluid Used Johnson Motors Pydraul A- 200 Lesser Castings Pydraul 312 Central Diccasting . Pydraul 312 Location-Sample Sump Stream Bed Sump . Analysis-Sample % Solids 70 80 44 % Fluid 30 20 56 Specific Gravitv 1.32 . Fluid 1. 41 1.09 . Specific Gravity 1.42 New Pydraul 1.42 1.10-1.20 % Pydraul 70% 100% 95-100% Solids Present Absorbent Aluminum Fines Absorbent Absorbent & Inorganic Aluminum Fines Dommcnts on Pydraul Recovery' Solvc nt Solvent extraction extraction required. re quired Sol vent extraction required v9 Oo Sump 2 98 1.13 1,10-1.20 Absor bent Aluminum Fines Filtration type only MONS 035191 TABLE III PYDRAUL EFFLUENT ANALYSES STEEL INDUSTRY (see Figure I) 41 . Solid/Fluid Pydraul Ratio ppm0 ` pal/yr % Total Wisconsin Steel (1) Castor Pit -- (2) Settling Basin -- 3727 2400c ~-100% 1. 53 0.2 ' nil (3) Cooling Towe r Overflow 0.63 0.1 nil Wheeling Steel (1) Scale -- 155 2200d .90 (2) Scale Pit overflow 0.1 200 10-12 Timken Steel ' (!) Hi Tube Mill (2) #4 Tube Mill (3) Pond-Top . (4) Pond-bottom --1:50 4:1 0. 017 25 0.125 200 . -'-- --- 0.1 1 nil. -- (5) Pond-overflow 0.126 r ' a) excluding water b) cxpressod as PCB content c) at 100 lbs per day scale (solids) throughput c)at 1 ton per day scale (solids) throughput Recoverability Difficult- solvent extract N/A N/A Difficult-solvent extract N/A N/A N/A No evidence of Pydraul-all oil No evidence of Pydraul, all oil. Solvent extraction from solids requirc< HONS 035192