Document By39nVZaYpQzGb5pbXa4wDOkJ

Specialties, Heating The Fulton Sylphon Company NEW YORK Hudson Terminal Bldg. 50 Church Street Knoxville, Tennessee SALES OFFICES: CHICAGO Wrigley Bldg. Michigan Boulevard PHILADELPHIA Drexel Bldg. 4th and Chestnut Streets DETROIT General Motors Building Representatives in All Principal Cities Boston Federal Bldg. 136 Federal Street Patentees and manufacturers of Sylphon products. Sylphon Automatic Air and Vent Valves; Packless Expansion Joint; Thermostats for regulating tem peratures of homes by warm air furnaces, steam, vapor or hot water boilers; Temperature and Pressure Regulators, Temperature Regulating Radiator Covers; and other Heating Specialties. Advantages. All Sylphon devices em body the seamless, one-piece bellows of drawn metal shown at right. There is riot a bit of solder throughout its length --no chance for leaks or breaks. It is a feature found exclusively in Sylphon Prod ucts. Sylphon diaphragms or bellowsare made in sizes rang ing from 1H to 12 in. O. D. No. 410 Sylphon Air Line Valve An automatic. non-adjustab!e air line valve that will silently expel air and condensation, but close against steam. Has as its basic principle the Sylphon thermostat, which will quickly and effectively distinguish between steam and air. freely allowing the . air and con densation to pass, but pre venting the passage of steam. This.means that every inch of radiating surface becomes 100 per cent efficient. Ask for Bulletin RRAV-3. SPECIFICATION--All radiators to be equipped with Cut Open View . Sylphon Air Line Valves known as (either No. 410 or No. 410-A), as manu factured by The Fulton Sylphon Company. Knox- . ville, Tenn. No. 510 Sylphon Vent Valves for Primary Heating Coils For venting air from large heating coils used in stacks and in indirect heating with fan blowers, where low-pressure steam is used. Venting port % in. dia. Has a powerful Sylphon bel lows as * thermostat which closes valve immediately steam reaches it. Does hot close against water. Can be installed in any position. Made entirely of cast brass; ruggedly constructed. Ask for Bulletin RRAV-3. SPECIFICATION--Heating Coils, where shown on plans,-shall be vented with No. 510 Sylphon Vent Valves as manufactured by The Fulton Sylphon Company. Knoxville, Tenn., and installed in accordance with instructions furnished by the manufacturer. No. 527 Quick Vent Valve For venting mains, long runs of pipe, indirect stacks, drop risers, and all low-pressure steam jobs where a large amount of air must be expelled quickly. Contains Sylphon bellows as thermostat. Vents entire piping system and thereby heating radiators quicker under less pressure.. No adjust ment. Does not close against water. Venting port A in. diame ter. Valve connection % in. pipe { thread. Ask for Bulletin RRAV-3. I SPECIFICATION--The ends of long runs of pipe, risers or loops shall be vented with a No. 527 . Sylphon Quick. Vent Valve, as manufactured by the Fulton Syl- ~ phon Company, Knoxville, Tenn. Cth Open View No. 110 Sylphon Packless Expansion Joint for Low Pressure Steam Heating Risers The Sylphon Packlesa Expansion Joint eliminates all packed type expansion joints, scissors, swing loops and similar devices generally used in in stalling low pressure steam heating risers. The pipe movement b taken ap in the joint oy. the expansion of a Sylphon bellows so utilized as to provide, a continuous sealed line. Sylphon Packless Expansion Joints are designed for use on steam pressures up to 15 lb. per so. in., but may be tem porarily subjected to steam pressures up to 25 lb. per sq. in. They should never be tested with steam pressures in excess of 25 lb. per sq. in., or water pressures in excess of 50 lb. per sq. in. Sylphon Joints should be located near the floor or ceiling. If concealed in walls, access doors or removable panels should be provided. It b important to install them with the end marked "top" in the correct position. Piping should be installed_xin a true vertical position, but the guides on the outside casing insure correct alignment, and prevent torsional or eccentric strains on the No. 110 Sylphon bellows. Ask-for Bulletin RREJ-100. size, in,.. ,1% 2 2% Lengths: A--Extended.... B--Compressed.. 12 I0/i lift 1101'%/, 13% "% i3y, 12% 13% 15% '8* WD--Width............. 3% 4% Wi 5% 6 i'AE--Installed.... M3/. i 12ft 13% 143/8 15*/# il*Shipping wt^ lb.... 18 25 35 50 60 List prices.................. (12 12 14 16 20 23 27 SPECIFICATION--Install where shown on riser plans No. 110 Sylphon Packless Expansion Joint, as manu factured by The Pulton Sylphon Company;Knoxville, Tenn., with end marked "top" in proper position; the joint to be of____ in. pipe size and for steam (water) pressure of not over 15 lb. (50 lb.) per sq in. 588 The Fulton Sylphon Company Specialties, Heating No. 22 Steam Damper Regulator Used to control the dampers oo steam heating boilers. A simple, accurate regulator which will control the draught so as to maintain a con stant steam pressure up to 5 lb. Thb regulator b sensitive, positive in action and will last a life time, due to the Sylphon one-pieoe, seamless, -solderless, flexible metal bellows which it contains as dia phragm. Ask for Bulletin RRDR-8. SPECIFICATION--The boiler shall be equipped with a No. 22 Sylphon Steam Damper Regulator, as manu factured by The Fulton Sylphon Company, Knoxville, Tenn., and installed in accordance with instruction of the manufacturer. No. 22-J Steam Damper Regulator Thb Regulator b identical in construction with No. 22 except that it contains a smaller Sylphon bellows as its diapnragm and b therefore suitable for small steam boilers or those having light H9 dampers which do not require much power for their op eration. Will main tain a constant steam pressure up to 8 lbs. _ gauge. Ask for Bulletin RRDR-8 SPECIFICATION--The boiler shall be equipped with a No. 22-J Sylphon Steam Damper Regulator, as - manufactured by The Fulton Sylphon Company, Knoxville, Tenn., and installed -in accordance with mstractions of No. 924 Steam Damper Regulator For low pressure steam boilers where extra sensitiveness and greater power are required to op erate the damper. Is identical in con struction with No. 22 except that it contaiosa larger Sylphon bellows as its dia phragm, and dis tance between rocker pivot and plunger pivot b greater. Will operate with pressures up to 3 lbs. gauge. Ask-for Bulletin RRDR-8 SPECIFICATION--Boiler shall be equipped with a No. 924 Svlphon Steam Damper Regulator as manufac tured by The Fulton Sylphon Company, Knoxville, Tenn., and installed in accordance with instructions of the manu facturer. No. 925 Vapor Damper Regulator Specially designed to control dampers on boilers used.with vapor heating systems. Extremely powerful and sensitive. Hna extra large flexible Sylphon bellows as dia-' phragm. One ounce change in vapor pressure produces a 6l/i ibe. force to open or close damp ers. Operates from 2 ozs. to 1 lb. gauge, perfectly smoothly and will not "flutter" under any condition. Ask for Bulletin RRDR-8 . SPECIFICATION--The boiler shall be equipped with' a No. 925 Sylohon Vapor Damper Regulator, as manu factured by The Fulton Sylphon Company, Knoxville, Tenn., ana installed in accordance with instructions of the manufacturer. ' No. 45-A Hot-Water Damper Regulator Used to control the dampers on hot-water heating boilers Contains Sylphon Bellows as diaphragm. A simple, accurate regulator which will control the draft so as to maintain a constant temperature of the water at any point between 120 deg. and 220 deg. fahr. Prevents the tempera ture of the water from rising higher than necessary, installed on -domestic hot-water heaters, insures faucet water of even tem perature every hour of the day. Prevents the generating of steam in the system, thus eliminating disagreeable sputtering and blowing-off when faucet b open. Ask for Bulletin RRDR-8. No. 45 Hot-Water Damper Regulator Same as No. 45-A exceptbulb b 4 in. instead of 2 in. long and rocker does not have adjustment. The longer bulb permits the use of thb regulator in a pipe fitting. Ask for Bulletin RRDR-8 No. 46 Hot-Water Damper Regulator Thb regulator with bulb 1 in. long, b designed especially for small hotwater-heating boilers, or those having light dampers, also, domestic hotwater supply heaters. Construction same as No. 45 except that it contains a rnnidW Sylphon bellows as its diaphragm, as it requires less power to operate the light dampers of such heaters. Also suitable for laundry heaters, garbage burners, garage heaters, etc. Ask for Bulletin RRDR-8. SPECIFICATION--(Boiler, beater, or tank heater whfttl be equipped with a No. (45,45-A, 45-B or 4<5) Sylphon Hot-Water Damper Regulator, as manufactured by The Fulton Sylphon Company, Knoxville, Tenn., the regulator to have a temperature range of (specify temperature range. No. 45 and 45-A have temperature range of 120 deg. to 220 deg. fahr.; No. 45-B has temperature range of 100 deg. to 200 deg. fahr.; No.46 has temperature range of 130 deg. to 200 deg. fahr.) and to be installed in accordance with instructions furnished by the manufacturer. Nos. 42, 45, 44, Hot-Water Damper Regulators These regulators are used where conditions require side instead of direct connections. The hot-water circulates `around an inner bulb containing a volatile Canid, which in turn causes the Sylphon bellows to expand or contract as the temper ature of the water rises or falls, thus dosing or opening the draft dampers. Ask for bulletin RRDR-8. SPECIFICATION--(Boiler heater or tank heater) shall be equipped with a No. (42, 43, or 44) Sylpnon Hot-Water Damper Regulator. as manufactured by The Fulton Sylphon Company, Knoxville, Tenn., the regulator to have a temperature range of (specify--No.'42 controls from 120 deg. to 180deg. fahr.; No. 43 from 160 deg. to 220 deg. fahr.; No. 44 from 190 deg. to 240 deg. fahr.) and to bo installed in accordance' with instructions furnbhed by manufacturer. 589