Document By39nVZaYpQzGb5pbXa4wDOkJ
Specialties, Heating
The Fulton Sylphon Company
NEW YORK
Hudson Terminal Bldg. 50 Church Street
Knoxville, Tennessee
SALES OFFICES:
CHICAGO
Wrigley Bldg. Michigan Boulevard
PHILADELPHIA
Drexel Bldg. 4th and Chestnut Streets
DETROIT General Motors Building
Representatives in All Principal Cities
Boston
Federal Bldg. 136 Federal Street
Patentees and manufacturers of Sylphon products. Sylphon Automatic Air and
Vent Valves; Packless Expansion Joint; Thermostats for regulating tem
peratures of homes by warm air furnaces, steam, vapor or hot water boilers;
Temperature and Pressure Regulators, Temperature Regulating Radiator
Covers; and other Heating Specialties.
Advantages.
All Sylphon devices em body the seamless, one-piece bellows of drawn metal shown at right. There is riot a bit of solder throughout its length --no chance for leaks or breaks. It is a feature found exclusively in Sylphon Prod ucts. Sylphon diaphragms or bellowsare made in sizes rang ing from 1H to 12 in. O. D.
No. 410 Sylphon Air Line Valve
An automatic. non-adjustab!e air line valve that will silently expel air and condensation, but close against steam. Has as its basic principle the Sylphon thermostat, which will quickly and effectively distinguish between steam and air. freely allowing the . air and con densation to pass, but pre venting the passage of steam. This.means that every inch of radiating surface becomes 100 per cent efficient. Ask for Bulletin RRAV-3.
SPECIFICATION--All radiators to be equipped with Cut Open View . Sylphon Air Line Valves known as (either No. 410 or No. 410-A), as manu factured by The Fulton Sylphon Company. Knox-
. ville, Tenn.
No. 510 Sylphon Vent Valves for Primary Heating Coils
For venting air from large heating coils used in stacks and in indirect heating with fan blowers, where low-pressure steam is used. Venting port % in. dia. Has a powerful Sylphon bel lows as * thermostat which closes valve immediately steam reaches it. Does hot close against water. Can be installed in any position. Made entirely of cast brass; ruggedly constructed. Ask for Bulletin RRAV-3.
SPECIFICATION--Heating Coils, where shown on plans,-shall be vented with No. 510 Sylphon Vent Valves as manufactured by The Fulton Sylphon Company. Knoxville, Tenn., and installed in accordance with instructions furnished by the manufacturer.
No. 527 Quick Vent Valve
For venting mains, long runs of
pipe, indirect stacks, drop risers,
and all low-pressure steam jobs
where a large amount of air must
be expelled quickly. Contains
Sylphon bellows as thermostat.
Vents entire piping system and
thereby heating radiators quicker
under less pressure.. No adjust
ment. Does not close against
water. Venting port A in. diame
ter. Valve connection % in. pipe {
thread. Ask for Bulletin RRAV-3. I
SPECIFICATION--The ends
of long runs of pipe, risers or loops
shall be vented with a No. 527 .
Sylphon Quick. Vent Valve, as
manufactured by the Fulton Syl-
~
phon Company, Knoxville, Tenn. Cth Open View
No. 110 Sylphon Packless Expansion Joint for
Low Pressure Steam Heating Risers
The Sylphon Packlesa Expansion Joint eliminates all packed type expansion joints, scissors, swing loops and similar devices generally used in in stalling low pressure steam heating
risers. The pipe movement b taken ap
in the joint oy. the expansion of a Sylphon bellows so utilized as to provide,
a continuous sealed line.
Sylphon Packless Expansion Joints are designed for use on steam pressures
up to 15 lb. per so. in., but may be tem porarily subjected to steam pressures up
to 25 lb. per sq. in. They should never
be tested with steam pressures in excess
of 25 lb. per sq. in., or water pressures in excess of 50 lb. per sq. in.
Sylphon Joints should be located near the floor or ceiling. If concealed in walls, access doors or removable panels
should be provided. It b important to install them with the end marked "top"
in the correct position. Piping should
be installed_xin a true vertical position,
but the guides on the outside casing
insure correct alignment, and prevent torsional or eccentric strains on the
No. 110
Sylphon bellows. Ask-for Bulletin RREJ-100.
size, in,..
,1% 2 2%
Lengths:
A--Extended.... B--Compressed..
12 I0/i
lift
1101'%/,
13% "%
i3y, 12%
13%
15%
'8* WD--Width............. 3%
4% Wi 5% 6
i'AE--Installed....
M3/. i 12ft 13% 143/8 15*/#
il*Shipping wt^ lb....
18 25 35 50 60
List prices.................. (12 12 14 16 20 23 27
SPECIFICATION--Install where shown on riser plans No. 110 Sylphon Packless Expansion Joint, as manu factured by The Pulton Sylphon Company;Knoxville, Tenn., with end marked "top" in proper position; the joint to be
of____ in. pipe size and for steam (water) pressure of not over 15 lb. (50 lb.) per sq in.
588
The Fulton Sylphon Company
Specialties, Heating
No. 22 Steam Damper Regulator
Used to control the dampers oo steam heating boilers. A simple, accurate regulator which will control the draught so as to maintain a con stant steam pressure up to 5 lb. Thb regulator b sensitive, positive in action and will last a life time, due to the Sylphon one-pieoe, seamless, -solderless, flexible metal bellows which it contains as dia phragm. Ask for Bulletin RRDR-8.
SPECIFICATION--The boiler shall be equipped with a No. 22 Sylphon Steam Damper Regulator, as manu factured by The Fulton Sylphon Company, Knoxville, Tenn., and installed in accordance with instruction of the manufacturer.
No. 22-J Steam Damper Regulator
Thb Regulator b identical in construction with No. 22
except that it contains a smaller Sylphon bellows as its
diapnragm and b
therefore suitable for
small steam boilers
or those having light H9
dampers which do
not require much
power for their op
eration. Will main
tain a constant steam
pressure up to 8 lbs.
_
gauge.
Ask for Bulletin RRDR-8
SPECIFICATION--The boiler shall be equipped with a No. 22-J Sylphon Steam Damper Regulator, as - manufactured by The Fulton Sylphon Company, Knoxville, Tenn., and installed -in accordance with mstractions of
No. 924 Steam Damper Regulator
For low pressure steam boilers where extra sensitiveness and greater power are required to op erate the damper. Is identical in con struction with No. 22 except that it contaiosa larger Sylphon bellows as its dia phragm, and dis tance between rocker pivot and plunger pivot b greater. Will operate with pressures up to 3 lbs. gauge.
Ask-for Bulletin RRDR-8
SPECIFICATION--Boiler shall be equipped with a No. 924 Svlphon Steam Damper Regulator as manufac tured by The Fulton Sylphon Company, Knoxville, Tenn., and installed in accordance with instructions of the manu facturer.
No. 925 Vapor Damper Regulator
Specially designed to control dampers on boilers used.with
vapor heating systems. Extremely powerful and sensitive.
Hna extra large
flexible Sylphon
bellows as dia-'
phragm. One
ounce change in
vapor pressure
produces a 6l/i
ibe. force to open
or close damp ers. Operates from 2 ozs. to 1 lb. gauge, perfectly smoothly
and will not "flutter" under any condition.
Ask for Bulletin RRDR-8 .
SPECIFICATION--The boiler shall be equipped with'
a No. 925 Sylohon Vapor Damper Regulator, as manu
factured by The Fulton Sylphon Company, Knoxville,
Tenn., ana installed in accordance with instructions of
the manufacturer.
'
No. 45-A Hot-Water Damper Regulator
Used to control the dampers on hot-water heating boilers Contains Sylphon Bellows as diaphragm. A simple, accurate regulator which will control the draft so as to maintain a constant temperature of the water at any point between 120 deg. and 220 deg. fahr. Prevents the tempera ture of the water from rising higher than necessary, installed on -domestic hot-water heaters, insures faucet water of even tem perature every hour of the day. Prevents the generating of steam in the system, thus eliminating disagreeable sputtering and blowing-off when faucet b open. Ask for Bulletin RRDR-8.
No. 45 Hot-Water Damper Regulator
Same as No. 45-A exceptbulb
b 4 in. instead of 2 in. long and rocker does not
have adjustment. The longer bulb permits the use of thb
regulator in a pipe fitting.
Ask for Bulletin RRDR-8
No. 46 Hot-Water Damper Regulator
Thb regulator with bulb 1 in. long, b designed especially for small hotwater-heating boilers, or those having light dampers, also, domestic hotwater supply heaters. Construction same as No. 45 except that it contains a rnnidW Sylphon bellows as its diaphragm, as it requires less power to operate the light dampers of such heaters. Also suitable for laundry heaters, garbage burners, garage heaters, etc. Ask for Bulletin RRDR-8.
SPECIFICATION--(Boiler, beater, or tank heater whfttl be equipped with a No. (45,45-A, 45-B or 4<5) Sylphon Hot-Water Damper Regulator, as manufactured by The Fulton Sylphon Company, Knoxville, Tenn., the regulator to have a temperature range of (specify temperature range. No. 45 and 45-A have temperature range of 120 deg. to 220 deg. fahr.; No. 45-B has temperature range of 100 deg. to 200 deg. fahr.; No.46 has temperature range of 130 deg. to 200 deg. fahr.) and to be installed in accordance with instructions furnished by the manufacturer.
Nos. 42, 45, 44, Hot-Water Damper Regulators
These regulators are used where conditions require side instead of direct connections. The hot-water circulates `around an inner bulb containing a volatile Canid, which in turn causes the Sylphon bellows to expand or contract as the temper ature of the water rises or falls, thus dosing or opening the draft dampers.
Ask for bulletin RRDR-8. SPECIFICATION--(Boiler heater or tank heater) shall be equipped with a No. (42, 43, or 44) Sylpnon Hot-Water Damper Regulator. as manufactured by The Fulton Sylphon Company, Knoxville, Tenn., the regulator to have a temperature range of (specify--No.'42 controls from 120 deg. to 180deg. fahr.; No. 43 from 160 deg. to 220 deg. fahr.; No. 44 from 190 deg. to 240 deg. fahr.) and to bo installed in accordance' with instructions furnbhed by manufacturer.
589