Document BvedKvYDkna6LZ9qJa3Ve25nJ

! THE FINDING OF CHLORINATED DIBENZOFURANS IN A JAPANESE POLYCHLORINATED BIPHENYL SAMPLE by JOHN A. G, ROACH and IRWIN H. POMERANTZ Division of Chemical Technology Food and Drug Administration Washington, D. C. 20204 i i l I I I i i I I I HONS 061008 Tho presence of Ultra- and pentaciilorinated dlbenzofurans and hexa- and licpCachlorlnntcd naphthalenes in two samples'of polychlorinated biphenyl mixtures (PCI)) of European origin'has been reported by VOS, cu. al. (1970a). Their interest in a content analysis of the two PCB samples for impu ricies wasi stimulated by previous work in which toxic effects observed in chicks were attributed to these two samples (VOS, et. al. 1970b). . I *. , ! Kanechlor 400: (KC-400),,a commercial PCB preparation of Japanese origin has bcon identified as the causative agent iin Yusho, a human poisoning incident resulting from the ingestion of rice oil contaminated with KC-400 (KURATSUNE, et. al. 1972). Ue have analyzed a sample of KC-400 made available to us from tha Kanegafuchi Chemical Industrial Co., Ltd. through Dr. rf. Blumenthal of the Food mid Drug Administration to determine whether potentially hazardous .chemicals, particularly chlo rinated dibenzofurans (01-DBF), were present as contamlnands. It was tho objective of this analysis. to obtain, where pos sible, structural information on these contaminants and an . estimate of their concentration in the KC-400, ' ' expertmkntat. . A hexane solution of the KC-400 was gas chromatographed, using an elettPdn capture detector, on a column of 10*4 DC-200 on Chromosorb WHP (Ho-100 mesh) and on a mixed column of 157. QF-1 + 10% DC-200 each coated on Chromosorb WHP (80-100 mesh) and mixed in a 1:1 weight ratio. The KC-400 (chlorine content ' 48%) showed only minor differences in peak locations and relative' peak heights from Amclor 1248 (chlorine content 487,), a PCB of American manufacture. Therefore, Aroclor 1248 to which -a mixture of di- tri- and tocrnchlorinatcd dibenzofurans^ had been added* * was used by Porter to devise a procedure to separate Cl-DBF ` from PCB (PORTER, lV7lb), This procedure is outlined in Figure I. ` ^ This reference mixture was kindly provided by Albert pohland, ph.D., of FDA. It wns. prepared by chlorination of dibsnzofurnn in tetrachloroethylene with iron powder as catalyst. M0NS 061009 I KC-400. in hexane solution Florlsll fcoluron. FCB In eluate A (discard) . Cl-DBF In eluate B : Alumina Micro Column (PORTER, 1971a) \ ii PCB In eluate 1 . (discard) . Cl-DBF In eluate 2 !` Figure I. Procedure for Separation of Chlorinated Dlbenzofurans from Chlorinated Biphenyls in KC-400. The Florlsll (8g. of 60/100 mesh PR grade) was activate^ by heating at 130C i 12 hr. and cooled to room temperature in a desiccator, prior to the addition of sample, to the column,!the Florlsll column was prewashed with about 25 mL hexane. The KC-400/hexane solution (< 2 ml) was placed on the Florlsll which was contained in a 10 ran i.d. 300 mm glass column fitted with a teflon stopcock and medium porosity fritted disk. The column was eluted with two eluants in succession at the rate of about 5 ml/min. Eluant A was 150 ml hexane. Eluant B was 100 ml 5% ethyl ether in hexane. Eluate B was concentrated to ; about one ml before placing the sample on the alumina micro* column. . Hie micro column was a disposable plpet of roughly 5 nn bore into which a small wad of glass wool had been inserted . to retain the aluminum oxide. Merck alumina which had been heat activated exactly like the Florlsll was- poured Into the column to a depth of 2.5 cm. Sample or eluting solvent was then added to the column with the aid of a disposable pipet 1 or a largo glass syringe. Eluant 1 was 10 ml 17* methylene chloride in hexane. Eluant 2 was 6 ml 20% methylene chlo` ride In hexano. Further PCB removal was accomplished by concentrating eluate 2 to about one ml and subjecting it to HONS 061010 I a second alumina micro column cleanup, simply repeating the alumina column procedure.' 1" { . i Tills procedure was first applied to duplicate two mg. por- tlons of KC-400. Electron capture gas chromatography of ; eluato 2 showed a gas chromatographic peak in each sample that had a relative retention time matching that of a tet.rachlo- rodibanzofuran on both a 10% OV-101 and a 1:1 10% DC-200 + 15% QF-1 column under Pesticide Analytical Manual condi- i tlons.2 The reference material for this retention time com- parlson was the tetrachlorodibenzofuran component in the miix- ture of chlorinated dlbenzofurans (see footnote 1). I j- : 1 To obcaln sufficient material from the KC-400 for combined gas chromatography/mass spectrcmatry (GC/MS) analysis, the pro- cedure was scaled up to permit cleanup of 8 mg portions of ! KC-400, Cleaned up aluates (cluatc 2) were then combined Co give two composite'samples, each equivalent to approximately 100 mg KC-400. Th.se two composites were analyzed by CC/MS (Flnnlgan 1015 quadrupole mass spectrometer) and tha re- | suiting date were -examined for evidence of the presence of i compounds that were not chloroblphenyls. A reagent blank of equivalent size was also analyzed by GC/MS. The reagent j blank contained none of the compounds found in the samples.! The qualitative results of the KC-400 analyses are summa- , rlzed in Table I. *The identification of the compounds I Hated in Table I was based on a comparison of the mass j spectra of tha sample compounds with the mass spectra of the chlorinated dlbenaofuran components in the-reference mix- ' ture described in footnote one and on comparison with mass spectral data on'Chlorinated dibenzqfurans in tha published literature (VOS at. el., 1970a; FIRESTONE, et. al., 1972; | PLIMMER, et. al., 1973). .j ' The amount of tetrachlorodibenzofuran contained in the | reference mixture.was approximated by comparing its micro- , eoulometric GC response with the response given by a known (quan tity of a tetrachlorodibenzodioxin of known structure. Thc^ totrachlorodlbenzodioxin was considered an appropriate micro- eoulometric reference .compound because of its structural t i ' : 1 ' - , I | j ! j 1 ' ; j , | , i j I ` i i 2 Gas chromatographic conditions: glass column, 6 ft. x 4 I nuld., @ 200C with 225C injector; carrier gas, nitrogen} @ 120 ml/mln.; detectortritium source (concentric type)1, operated In oloctron capture mode at 210C. Detector < voltngo was adjusted so that 1 ng hcptachlor epoxide causes 1/2 full ncalc recorder dcfloctlon at 1 x 10~* AFS. ! . i *i .. .. HGNS ' ' . Ohio11 I similarity to tetrachlorodtbenzofuran. The electron capture! GC responses of the tetrachlpro componont in the synthetic mixture and in the KC-400 extracts were .then compared to quantitate the tctrachlorodibunzofuran in the KC-400. The J I J KC-400 was estimated to contain approximately 1 ppm tetra- chlorodibenzofuran. t - .. , . I ' >' i 1 : i ! Compounds Present In Kanechlor 400 After Cleanup* V . .. . ' 4, . ; I mats (no. of Cl) and fragmentation data * ' - . molecular weight compound present ' of compound * I ' 256(3C1);M-2C1 \\ trlchloroblphenyl , 256 (! 270 (3C1) jM- (COfCl) trichlorodlbenzofuran ' 270 290(4C1);M-2C1 298(SCI) ;M-2C1 ' . totrochloroblplienyl ' t 290 pentachloroniaphthalene : 298 (( 1 304(4C1) jM- (COfCl), ' M-(C0f3Cl) . . tetrachlorodlbenzofuran i 304 ' 1 312(5C1);M-C1 `. ) t unidentified; perhaps < 312 methylpentachloro- i naphthalene or pentachloro- ' 11 phenyl cyclopentadiehe . 338(4 or 5C1); M-(C0f3Cl) indicated .V possible pentachlorodibenzofuran , 338 ` l listed In order, of elution from 37. OV-101, 6 ft. x 2 mm i;d. glass column at 220C, carrier flow 20 ml He/min.; the same MS evidence was found in both samples examined for all entries but the last (possible pentachlorodiben- . tofuran) for which a second determination was not attampted. 1 1 j 1 ; ' , ; . SUMMARY --------- iI ,I t| i Chlorinated dibenzofurans, including one ppra of totrachlorinatod dibenzofuran(s), and pontachloro naphthalene have been ; identified by combined gas chromatography/mass spectrometry id a HONS C61012 1 I polychlorinated biphenyl of Japanese manufacture (KC-400), Iho question of whether chlorinated dibenxofurans in KC-400 may have contributed to the reported Yusho incident is thus rained. ACKNOWLEDGEMENT ;j I " . I The authors wish to thank Sandra Marcier for assistance in the preparation of the samples for GC/MS analysis. I REFERENCES FIRESTONE, D., RESS, J., BROWN, N. L., BARRON, R. P. and I DAMICO, J. N.: J. Aas. Offic. Anal. Chem. 55, 85 (1972) ' ", 'I KURATSUNE, M., YOSHIMURA, T., MATSUZAKA, J., AND YAMAGUCHI, A.: Env. Health Ferspect. Expt. Issue #1, 119 (1972) ' i! PESTICIDE ANALYTICAL MANUAL,- Vol. I, sec. 311.2, Food and'Drug Administration, Washington, D.C., 1968, rev. 1969 and 1970 PLIMMER, J. R., RUTH, J. M. and WOOLSON, E. A.: 3. Agr. Uod Chem. 21, 90 (1973) . . 'I PORTER, M. and EURKE, J. A.: J. Ass. Offic. Anal. Chem. 54, (6) 1426 (1971a) . 'j PORTER, M.: Private Conkunicatlon, (Feb., 1971b) VOS, J. G., KOEKAN, J. H. , VAN DER MAAS, H.' L., TEN NOEVER DE BRAUW, M. C., and DE VOS, R. H.: Fd. Cosmet. Toxicol. 8,1 625 (1970a) .. : ' VOS, J. G., and ROEMAN, J. 11.: (3) 656 (1970b) | ' . '* V. ` Toxicol. Appl. Pharmacol .. ' `i I 17, MONS 061013