Document Bv8Z7XMXdJmRBqx94GO2gzE0w

o o .- O .V.ONi-'.XTO COMPANY . j-oui i, Missouri March ij. 1 970 CALL REPORT XO. IP-3 JOHNSOX IvlG VG'LS Wuuki.,^-* Illinois Present lor Johnson Motors: Present for Monsanto: .:roo.sc: CC: R. A. Dar.-.ic.-.i - Ch. ;i c. C. Decker - Eiedis.;, Chicvs R.A. Circii - .Akron W. R. iii chard - V/S1CK L, R. St a?* - LSC.AR Claude Trebeck - Master Me eh. Bill Lupi ow - Chemist John Xavill - foreman Machine Repair Tom Banski - Division MetaUurgis A1 Hanson - Environmental Services Ccorc. R. A. Datr.iani C. Docker - Biodico D. R. Pogue ' Pollution - Pydraul reclamation systems study. Z\e sui t s: Er.t husi as: i call y supported our efforts. 111 inoi s Department o; Publi c Health maintains regular check of air and water quality. Air discharge from aluminum melt furnaces primary concern. Smoke contains oil, solvent and Pydraul residues, Biodiao will recontact Johnson on air clean-up system. V/utor effluent' discharges have evident Pydraul content. Xogl gi ole treatment and inefficient reclamation now exists f or e: fl uer.t--except for plating operation. Complete data on fiosvs and chemicals consumption and samples for analysis from xcy waste flow point s wore ootained* Johnson promi sod `iuilow-uo of anal yti cal and study results. MCNS 072667 o o o 1 Do le ii *: Doth i*r unci water pollution arc concerns to Johnson Motors. Smelling 300, 000 lb aluminum monthly --50ft' scrap and 30ft new pig, Scrap from diccasting contains estimated 10ft by weight adhering Pydraul ar.d die lube, which arc primary source for dense, black smoke from the plant. State of Illinois complaints have stirred moderate activity by Johnson to solve problem. No solution yet, however considering higher temperature {1800*? instead of 1600''?) incineration of fluid contaminates during aluminum smelting. Studies by Aluminum-Magnesium, Incorporated on contaminated aluminum scrap show complete decomposition (no smoke )ut 1S00F. Above scrap contamination indicates 15, 000 lb or 1500 gal ($4500) Pydraul io*t monthly up the stack. Discussed possible wash and recovery of Pydraul. Contaminants would include Hi-Dri absorbent, aluminum fines, dirt, die lube among others. Dotrex Chemical Co. markets heat treating and chlorinated solvent wash system to this market. Johnson will plan eventually to incinerate at 1300*r, probably with wash as recommended by U.S. Reduction who offers system that tumble washes and sizes scrap prior to smelting. Decker . arranged for Biodize contact to pursue incineration opportunities he re. *' Several water outfalls from this location. All appear under control or not problem except diccasting area. Outfall from plating, anodizing and painting of diecast parts has been controlled oy treatment designed by Betz Laboratories, Trevose, Pennsylvania. Initial 516, 500 study and extensive analysis program in `oS resulted in system to reclaim and/or dispose of treated chromates, cyanides and metallic contaminates. Obtained copies of Betz study reports. Decker reports thru 3iodize recent joint agreement with eastern firm Monsanto has also acquired capability to engineer similar plating-anodizing treatment systems. Our potential for these * systems m metalworking-diccasting should be fully assessed assuming market exists for Pydraul reclamation systems. . Pydraul A 600 consumption in '69 was 95, 000 gallons. This usage went to four outlets; 1. Air via aluminum scrap smelting e. Dumpster -absorbed by Hi-Drir absorbent ' HONS 072668 3 3. Century Liquid Waite Company - Kenosha, Wisconsin bulk liquid wastes 4. Waste stream effluent Quantity of Pydraul in air already cited. Samples obtained for analysis from bulk waste and waste stream. Expect absorbent and waste stream account for 80% Pydraul outlet (83, 000 gal), air 10-15% ar.d bulk waste 5-10%. They estimate three 4000 gallon tank trucks of bulk waste fluid are picked up weekly by Century. Waste effluent from diecasting shown on diagram attached. Waste includes water and oil based dielubcs, pydraul, salv-a-sol solvent (for machine and floor cleaning) and small amounts of SAE 30 petroleum oil. Samples taken from oil interceptor and both waste outfalls, although only one outfall should contain above waste components. Johnson roughly estimated waste content a: less than 5 % Pydraul, 50% salv-a-sol and remainder diclubes. Johnson will provide suppliers, usage and brand of all above chemicals and record of bulk waste tanker shipment* for our study. Further Action Required: I ` 1. Letter of thanks to Trebock 2. - Inorganic Division check on boiler water scale chemicals for Hanson. 3. Further checks on Betz. Labs; Detrex; and W. R. Brill Company (per Betz report. ) 4. Market potentials for plating-anodizing treatment. D. R. Pogue /lb HONS 072669 j o SON .V.OTOKS -- PLANT ( 1