Document BroEgvLoO48ZBXNnBQD4pXpE
FR-A-7
PLAINTIFF'S EXHIBIT
more BTU's for the monep.
pm
AmemcAN-^tandard flame retention oil heating units
Put a new FR next to a "same-size" conventional boiler and you'll say "So what?" But-fire them up and compare perform ances--it's all the difference in the world! THE NEW FR OPERATES AT GREATER EFFICIENCY AND HIGHER OUTPUT--with no increase in size, no boost in price!
Two things make that difference: (1) The flame retention burner generates more heat by precisely mixing air and oil so that every particle of fuel is burned. (2) Improved internal design exposes more cast iron sectionarea to this highly concentrated flame. No combustion chamber is needed on wet-base models -- a big help on the job and there's no worry about future replacement.
19 models for steam, forced circulation and gravity hot water l=B=R approved outputs 275,000 to 3,000,000 Btuh ideal for large homes, and all commercial and industrial installations life time cast iron sections (tested at 2W times normal operating pressure) sturdy steel jacket attractively finished in gray, fully insulated provision for an internal domestic hot water coil on models FR-A-3 and FR-A-5 and an external domestic hot water arrangement on the model FR-A-7
11488
/j~^Ln$ flame retention oil heating units
FR ratings
unit number*
steam
water
FR-A-36-SBIT) FR-A-37-S8(T)
FR-A-36-WB(T) FR-A-37-WBCD
trots l=B=R output (Btu/hr)
275.000 325.000
net l=B=R ratlnts
water A steam (Btu/hr)
water steam (sq. ft.) (sq.ft)
l=B=R l=B=R burner allowance capacity for
(tph) piping*.
206,300 243,800
1375 1625
860 1016
2.45 2.90
1.333 1.333
chimney
size heifht On.) (ft)
8x12 8x12
15 IS
water content
full (Ballons)
30.5 33.8
FR-A-504-SB(T)
FR'A-505-SB(D FR-A-506-SB(T) FR-A-507-SB(T) FR-A-508-SB(T) FR-A-509-SB(T) FR-A-510-SB(T) FR-A-511-SB(T)
FR-A-504-WB(T) FRA-505-WB(T) FR-A-506-WBCT) FR-A-507-WB(T) FR-A-508-WB(T) FR-A-509-WB(T) FR-A-510-WB(T) FR-A-51l-WB(T)
384.000 472.000 560.000 648.000 736.000 824.000 912.000 1,000,000
288,100 354.100 420.100 486.100 552.100 618,200 684.200 750.200
1921 2361 2801 3241 3681 4121 4561 5001
1200 1475 1750 2025 2301 2576 2851 3126
3.55
1.333
12x12
15
57.7
4.30 1.333 12x12 20
66.7
5.10 1.333 12x12 20
75.5
5.90
1.333
12x16
20
84.5
6.70
1.333
12x16
20
93.4
7.45 1.333 12x16 20 102.3
8.25 1.333 16x16 20 111.3
9.05 1.333 16x16 20 120.2
FR-A-706-SO-B FR-A-707-SO-B FR-A-708-SO-B FR-A-709-SO-8 FR-A-710-SO-B FR-A-711-SO-8 FR-A-712-SO-B FR-A-713-SO-B FR-A-714-SO-B
FR-706-WO-B FR-707-WO-B FR-708-WO-B FR-709-WO-B FR-710-WO-B FR-711-W0-B FR-712-WO-B FR-713-WO-B FR-714-WO-B
1,160,000 1.376.000 1.580.000
,1.812.000
2 020,000 2,228,000 2.440.000 2.720.000 3,000,000
870,200 1.041.600 1,211,700 1.403.600 1,568,300 1.729.800 1,894,400 2.111.800 2,329,200
5801 6944 8078 9357 10455 11532 12629 14079 15528
3626 4340 5049 5848 6535 7208 7893 8799 9705
10.55 1230 14.15 16.35 18.15 20.20 21.95 24.10 26.30
1.333 1321 1.304 1.291 1.288 1.288 1.288 1388 1.288
16x16 16x20 16x20 20x20 20x20 20x20 20x24 20x24 24x24
30 167.3 35 . 189.5 35 211.6 40 233.7 45 255.9 55 277.9 60 302.5 70 327.1 80 351.7
Suffix "T" denotes jnlemxl tankless heater.
A American-Standard should be consulted before selecting an FR oil heating unit for installations having unusual piping and pick up requirements.
dimensions and tappings
unit number
dimensiens (inches)
AB number of flush Jacket sections Jacket extension
FR-A-36 FR-A-37
6 24% 39% 7 27% 43%
FR-A-504 FR-A-505 FR-A-506 FR-A-507 FR-A-508
FR-A-509 FR-A-510
FR-A-511
4 5
6 7 8 9 10
11
22% 27%
31% 36%
40% 45% 49%
54%
47% 52% 56%
61% 65% 70% 74% 79%
FR-A-706 6 49
FR-A-707 7 56% ' ---
FR-A-708 8 64
--
FR-A-709 9 71%
FR-A-710
10
79
--
FR-A-711
11
86%
--
FR-A-712 12
94
--
FR-A-713
13
101%
--
FR-A-714 14 109
number and size f tappings (inches)
flow
<l>-3 (l)-3
(2)-4 (2M (2J-4 (2M (2M (2V4 (2M (2)-4
(3M (3V4 (3M (4M (4M (4M (5M (5M (5)-4
return
(l)-2% (l)-2%
(4)-2% <4)-2% (41-2% (4>-2% (4V2% (4J-2% (4)-2% (4)-2%
(2)-6 (2)-6 (2)-6 (2}-6 (2)-6 (2H> (2>-6 (2)-6 (2H>
Ame Rican-Standard
s/ PLUMBING ANO HEATING DIVISION
AMERICAN RADIATOR t STANDARD SANITARY CORPORATION .0 WEST 40IH STREET NEW YORK N Y I00IS
form No. 155-2
FR oil heating units are designed and built to comply with the American Society of Mechanical Engineers' Code, and bear their approval symbol. Ratings have been approved by the Insti tute of Boiler and Radiator Manufacturers. American-Standard flame retention oil burners (115 and 230 voit/60 cycle) are listed with Underwriters' Laboratories, Inc. for No. 1 and No. 2 grades of fuel oil, whether obtained by distillation or by the catalytic cracking process. They are approved by the New York City Board of Standards and Appeals, the State Fire Marshal of the Commonwealth of Massachosetts, and the Department of
State Police, State of Connecticut.
11489
UtHo in