Document BroEgvLoO48ZBXNnBQD4pXpE

FR-A-7 PLAINTIFF'S EXHIBIT more BTU's for the monep. pm AmemcAN-^tandard flame retention oil heating units Put a new FR next to a "same-size" conventional boiler and you'll say "So what?" But-fire them up and compare perform ances--it's all the difference in the world! THE NEW FR OPERATES AT GREATER EFFICIENCY AND HIGHER OUTPUT--with no increase in size, no boost in price! Two things make that difference: (1) The flame retention burner generates more heat by precisely mixing air and oil so that every particle of fuel is burned. (2) Improved internal design exposes more cast iron sectionarea to this highly concentrated flame. No combustion chamber is needed on wet-base models -- a big help on the job and there's no worry about future replacement. 19 models for steam, forced circulation and gravity hot water l=B=R approved outputs 275,000 to 3,000,000 Btuh ideal for large homes, and all commercial and industrial installations life time cast iron sections (tested at 2W times normal operating pressure) sturdy steel jacket attractively finished in gray, fully insulated provision for an internal domestic hot water coil on models FR-A-3 and FR-A-5 and an external domestic hot water arrangement on the model FR-A-7 11488 /j~^Ln$ flame retention oil heating units FR ratings unit number* steam water FR-A-36-SBIT) FR-A-37-S8(T) FR-A-36-WB(T) FR-A-37-WBCD trots l=B=R output (Btu/hr) 275.000 325.000 net l=B=R ratlnts water A steam (Btu/hr) water steam (sq. ft.) (sq.ft) l=B=R l=B=R burner allowance capacity for (tph) piping*. 206,300 243,800 1375 1625 860 1016 2.45 2.90 1.333 1.333 chimney size heifht On.) (ft) 8x12 8x12 15 IS water content full (Ballons) 30.5 33.8 FR-A-504-SB(T) FR'A-505-SB(D FR-A-506-SB(T) FR-A-507-SB(T) FR-A-508-SB(T) FR-A-509-SB(T) FR-A-510-SB(T) FR-A-511-SB(T) FR-A-504-WB(T) FRA-505-WB(T) FR-A-506-WBCT) FR-A-507-WB(T) FR-A-508-WB(T) FR-A-509-WB(T) FR-A-510-WB(T) FR-A-51l-WB(T) 384.000 472.000 560.000 648.000 736.000 824.000 912.000 1,000,000 288,100 354.100 420.100 486.100 552.100 618,200 684.200 750.200 1921 2361 2801 3241 3681 4121 4561 5001 1200 1475 1750 2025 2301 2576 2851 3126 3.55 1.333 12x12 15 57.7 4.30 1.333 12x12 20 66.7 5.10 1.333 12x12 20 75.5 5.90 1.333 12x16 20 84.5 6.70 1.333 12x16 20 93.4 7.45 1.333 12x16 20 102.3 8.25 1.333 16x16 20 111.3 9.05 1.333 16x16 20 120.2 FR-A-706-SO-B FR-A-707-SO-B FR-A-708-SO-B FR-A-709-SO-8 FR-A-710-SO-B FR-A-711-SO-8 FR-A-712-SO-B FR-A-713-SO-B FR-A-714-SO-B FR-706-WO-B FR-707-WO-B FR-708-WO-B FR-709-WO-B FR-710-WO-B FR-711-W0-B FR-712-WO-B FR-713-WO-B FR-714-WO-B 1,160,000 1.376.000 1.580.000 ,1.812.000 2 020,000 2,228,000 2.440.000 2.720.000 3,000,000 870,200 1.041.600 1,211,700 1.403.600 1,568,300 1.729.800 1,894,400 2.111.800 2,329,200 5801 6944 8078 9357 10455 11532 12629 14079 15528 3626 4340 5049 5848 6535 7208 7893 8799 9705 10.55 1230 14.15 16.35 18.15 20.20 21.95 24.10 26.30 1.333 1321 1.304 1.291 1.288 1.288 1.288 1388 1.288 16x16 16x20 16x20 20x20 20x20 20x20 20x24 20x24 24x24 30 167.3 35 . 189.5 35 211.6 40 233.7 45 255.9 55 277.9 60 302.5 70 327.1 80 351.7 Suffix "T" denotes jnlemxl tankless heater. A American-Standard should be consulted before selecting an FR oil heating unit for installations having unusual piping and pick up requirements. dimensions and tappings unit number dimensiens (inches) AB number of flush Jacket sections Jacket extension FR-A-36 FR-A-37 6 24% 39% 7 27% 43% FR-A-504 FR-A-505 FR-A-506 FR-A-507 FR-A-508 FR-A-509 FR-A-510 FR-A-511 4 5 6 7 8 9 10 11 22% 27% 31% 36% 40% 45% 49% 54% 47% 52% 56% 61% 65% 70% 74% 79% FR-A-706 6 49 FR-A-707 7 56% ' --- FR-A-708 8 64 -- FR-A-709 9 71% FR-A-710 10 79 -- FR-A-711 11 86% -- FR-A-712 12 94 -- FR-A-713 13 101% -- FR-A-714 14 109 number and size f tappings (inches) flow <l>-3 (l)-3 (2)-4 (2M (2J-4 (2M (2M (2V4 (2M (2)-4 (3M (3V4 (3M (4M (4M (4M (5M (5M (5)-4 return (l)-2% (l)-2% (4)-2% <4)-2% (41-2% (4>-2% (4V2% (4J-2% (4)-2% (4)-2% (2)-6 (2)-6 (2)-6 (2}-6 (2)-6 (2H> (2>-6 (2)-6 (2H> Ame Rican-Standard s/ PLUMBING ANO HEATING DIVISION AMERICAN RADIATOR t STANDARD SANITARY CORPORATION .0 WEST 40IH STREET NEW YORK N Y I00IS form No. 155-2 FR oil heating units are designed and built to comply with the American Society of Mechanical Engineers' Code, and bear their approval symbol. Ratings have been approved by the Insti tute of Boiler and Radiator Manufacturers. American-Standard flame retention oil burners (115 and 230 voit/60 cycle) are listed with Underwriters' Laboratories, Inc. for No. 1 and No. 2 grades of fuel oil, whether obtained by distillation or by the catalytic cracking process. They are approved by the New York City Board of Standards and Appeals, the State Fire Marshal of the Commonwealth of Massachosetts, and the Department of State Police, State of Connecticut. 11489 UtHo in