Document BkyZ7bk0wQL7eakZoJKj5eLE

Air Conditioning ^fc^iiVs The Unit Heater and Cooler Co. Wausau, Wisconsin . Offices In Principal Cities MANUFACTURERS OF THE GRID UNIT (patented) All-cast aluminum "fins" bonded to cast high-test iron core. No soldered, brazed, or expand ed joints -- no unions--no seams --fewest,, connec tions possible. Typical Installation of Grid Unit Heater GRID UNIT HEATER DATA Model No. Dimensions Inches' A B c D` Face . Area SqFt Motor He Rpm Vol. at Fan Capacities 5 Lb Steam 60 Air Btu Final Temp. Approx. Shipping Weight Pipe Sites Supply Return 1000 if/. iiy. 9'/a (6 0.84 1/20 1700 578 29,400 107 100 iw i'/." 1200 I8'/i 13'/, II'/, 17'/, ! .04 1/20 1700 71 f 46.000 119 (20 IV." w 515 23V, 17'/, II'/, 20 1.65 * 1/10 1750 1290 59,600 102 160 )'/," I'/." 1500 m. 17'/, II'/, 20 1 67 1/10 1750 1450 77,500 109 210 i'/," iv," 1520 ip/. 17l/i II'/, 20 2.2 1/10 1750 1700 (04,000 _J(3 250 i'/," i'/." 520 m. 22'/, II'/, 21'/, 2.9 _ I/s 1150 2500 102,300 97 250 2" I'/." 2000 2S>/, 22'/, iiy. 21'/, 2.9 - 1/6 1150 2500 148,000 114 32? 2" iv," 2025 33'/, 22'/, ny, 21'/, 3.6 : 1/6 (150 2875 177,000 115 370 2" IV," 525 35'/, 27'/, 13 28 4.5 . 1/2 1150 4200 166,400 94 390 2" 1'/." 2504. 35'/, 271/, 13 28 4.5 1/4 1150 3200 210.000 118 420, 2" iy." 2500 35'/, 27'/, 13 28 4.5 1/2 1150 4200 225,000 108 440 2" i'/," 2530 37'/. 27'/, 13 28. 5,3 1/2 1150 4650 282,000 115 530 2" I'/." 530 39'/, 32>/, 13 29 6.5 1/2 1150 5300 260.500 105 600 . 2'/," iv." 3000 39'/, 32'/, 13 29 6.5 1/2 850 6350 341,000 109 690 2'/," IV." 3000 39'/, 32'/, 13 29 6.5 IV, 1150 8100 394,000 104 725 2'/," iy." .`Varies with type of motor. GRID UNIT HEATERS ARE NOT AFFECTED BY ELECTROLYTIC ACTION No leaks--no breakdowns. Low maintenance expense. More air changes per hour. Positive "directed" heat. Lower outlet temperatures. Larger air volume. Reduced fuel cost. Applicable to either lowor high steam pressure lines. Send lor Bulletin on Units not listed above. 840 Air Conditioning Unit //eaters and Coolers YIWNG RADIATOR Kjompjouuu Offices in all Principrwall Crititloiees " * Racine, Wis. Write For Literature Engineering Information At Request A ir Conditioning Unit Air Conditioning Units--are jnade in five physical sizes for home and industrial installations. Designed to do a complete air-conditioning job, heating, cooling, hu midifying, and dehumidifying. Moid SH Unit Heater Unit Heaters--Model SH and TH. A compiete.line of single and twin fan suspended units, 32 sizes ranging in capacities from 18,000 to 658,000 Btu per hr. "FH" Unit Heaters--ten models rang ing in capacities from 120,000 to 800,000 Btu per hr. These units are equipped with two, three, and four blower type fans, driven by single or variable speed motors. As oriel FIf Unit Heater STREAMAIRE Convector STREAMAIRE Convectors--areavailable in six distinct types of cabinet enclossures--free standing,! wall hung, partially recessed, fully recessed, bathroom cabinets, and plastered-in enclosures. Designed to operate on one pipe steam, two pipe steam, vapor, vacuum and. gravity hot water heating systems. Cooling Coils--Type "W" with con-, tinuous tubes, type "rC" with removable headers for use with water or brine. Commercial Units Commercial Units--Designed for use in connection with .heating, cooling, and air-conditioning units where a compact, efficient, heating surface is desired. Blast Units---as encased heating sur face for use in connection with forced air, heating, and cooling systems. . Blast Units "FC" Heating Units--combine the appearance of aSTREAMAI RE convector with the higher capacity of YOUNG Unit Heaters. Available in four physical sizes, equipped with single and two speed motors. FC Healing Unite Evaporators--Designed for mechanical refrigeration systems using Freon or methyl chloride. 841 Evaporators