Document BkyZ7bk0wQL7eakZoJKj5eLE
Air Conditioning ^fc^iiVs
The Unit Heater and Cooler Co.
Wausau, Wisconsin
. Offices In Principal Cities
MANUFACTURERS OF THE GRID UNIT
(patented)
All-cast aluminum "fins" bonded to cast high-test iron
core.
No soldered, brazed, or expand ed joints -- no unions--no seams --fewest,, connec
tions possible.
Typical Installation of Grid Unit Heater
GRID UNIT HEATER DATA
Model No.
Dimensions Inches'
A B c D`
Face . Area SqFt
Motor He Rpm
Vol. at
Fan
Capacities 5 Lb Steam 60 Air
Btu
Final Temp.
Approx. Shipping
Weight
Pipe Sites Supply Return
1000 if/. iiy. 9'/a (6
0.84
1/20
1700
578 29,400 107
100
iw
i'/."
1200 I8'/i 13'/, II'/, 17'/, ! .04
1/20
1700
71 f 46.000 119
(20
IV."
w
515 23V, 17'/, II'/, 20
1.65 * 1/10
1750
1290
59,600
102
160
)'/," I'/."
1500 m. 17'/, II'/, 20 1 67 1/10 1750 1450 77,500 109
210
i'/,"
iv,"
1520 ip/. 17l/i II'/, 20
2.2
1/10
1750
1700 (04,000 _J(3
250
i'/," i'/."
520 m. 22'/, II'/, 21'/, 2.9 _ I/s
1150 2500 102,300
97
250
2"
I'/."
2000 2S>/, 22'/, iiy. 21'/, 2.9 - 1/6
1150
2500 148,000
114
32?
2"
iv,"
2025 33'/, 22'/, ny, 21'/, 3.6 : 1/6
(150
2875 177,000
115
370
2"
IV,"
525 35'/, 27'/, 13 28
4.5 . 1/2
1150 4200 166,400
94
390
2"
1'/."
2504. 35'/, 271/, 13 28
4.5
1/4
1150
3200 210.000
118
420,
2"
iy."
2500 35'/, 27'/, 13 28
4.5
1/2
1150
4200 225,000
108
440
2"
i'/,"
2530 37'/. 27'/, 13 28. 5,3
1/2
1150
4650 282,000
115
530
2"
I'/."
530 39'/, 32>/, 13 29
6.5
1/2
1150
5300 260.500
105
600
. 2'/,"
iv."
3000 39'/, 32'/, 13 29
6.5
1/2
850 6350 341,000 109
690
2'/,"
IV."
3000 39'/, 32'/, 13 29
6.5
IV,
1150
8100 394,000
104
725
2'/,"
iy."
.`Varies with type of motor.
GRID UNIT HEATERS ARE NOT AFFECTED BY ELECTROLYTIC ACTION
No leaks--no breakdowns. Low maintenance expense. More air changes per hour. Positive "directed" heat.
Lower outlet temperatures. Larger air volume. Reduced fuel cost. Applicable to either lowor high steam pressure lines.
Send lor Bulletin on Units not listed above.
840
Air Conditioning Unit //eaters and Coolers
YIWNG RADIATOR
Kjompjouuu
Offices in all Principrwall Crititloiees
"
*
Racine, Wis.
Write
For Literature
Engineering Information At Request
A ir Conditioning Unit
Air Conditioning Units--are jnade in five physical sizes for home and industrial installations. Designed to do a complete air-conditioning job, heating, cooling, hu midifying, and dehumidifying.
Moid SH Unit Heater
Unit Heaters--Model SH and TH. A compiete.line of single and twin fan suspended units, 32 sizes ranging in capacities from 18,000 to 658,000 Btu per hr.
"FH" Unit Heaters--ten models rang ing in capacities from 120,000 to 800,000 Btu per hr. These units are equipped with two, three, and four blower type fans, driven by single or variable speed motors.
As oriel FIf Unit Heater
STREAMAIRE Convector
STREAMAIRE Convectors--areavailable in six distinct types of cabinet enclossures--free standing,! wall hung, partially
recessed, fully recessed, bathroom cabinets, and plastered-in enclosures. Designed to operate on one pipe steam, two pipe steam, vapor, vacuum and. gravity hot water heating systems.
Cooling Coils--Type "W" with con-, tinuous tubes, type "rC" with removable headers for use with water or brine.
Commercial Units
Commercial Units--Designed for use in connection with .heating, cooling, and air-conditioning units where a compact, efficient, heating surface is desired.
Blast Units---as encased heating sur face for use in connection with forced air, heating, and cooling systems. .
Blast Units
"FC" Heating Units--combine the appearance of aSTREAMAI RE convector with the higher capacity of YOUNG Unit
Heaters. Available in four physical sizes,
equipped with single and two speed motors.
FC Healing Unite
Evaporators--Designed for mechanical refrigeration systems using Freon or methyl chloride.
841
Evaporators