Document BeGJM20qzKpkYprQ1dRG81jJ

RESEARCH Mr. A. L. Jonas JOPLIN PLANT Sept. 16. 1957 PLAINTIFF'S* EXHIBIT >\fsG-.is:o'W:o Ret Partial Replacement of Whits Portland C*aent with Molding Plaster in Ons-Cote Formulation - Charaoteristics of Plant Made Batches. \S-'J As a continuation of our study of the partial replacanant of whita portland canant with an equivalent weight of molding plaster, several plant batches were made following the formulation suggested in our note of August 30. In each case 18 lbs. of molding plaster were used in the formulation and 18 lbs. of white Portland cement removed from the formulation. At the time these experimental batches were made, a single bag of One-Cote Cement, made just prior to the batch which contained the gypsum, was also removed for evaluation. In most oases. Tern Carico and Melvin Sherwood performed Independent tests on the samples with re gard to wet coverage. In addition. Sherwood made tests for shrinkage upon dry ing. abrasion resistance, hardness when saturated with water, compressive hard ness and setting up time. Tabulated below are those results that can be re ported as numerical valuest Lot No. Wet Coverage frd.ft/100 lbs. 9629 Ho Qypsum With Gypsum 35.7 35.6 9631 No Gypsum 36.5 With Oypsum 36.1 Shrinkage upon Abrasion Loss Tested by Drying - i ........................... 10-mln. 20-mln. None None 13.30 16.6 23.30 29.9 Sherwood . NAy,Oo-,n.Demi 13.3 12.8 24.1 23.1 Sharwood 9631 No Gypsum With Qjrpaua 9632 No Gypsum With Gypsum 9632 No Qypsum With Gypsum 35.2 35.5 39*2 41.2 35.2 35.2 None None 20.75 20.2 39.6 36.3 Carico * Shmerwood Carico 963^ No Gypsum With Qypsum 42.1 39.9 None None 42.4 30.9 55.4 Sharwood a 9634 No Gypsum With Oypsum 34.6 35.5 Crieo The additional tests mads by Sherwood showed that at all times the One-Cote Canent formulated with the gypsum had the ability to remain hard, even though the cement was saturated with water. Also his tests for compressive hardness showed that One-Cote Canent without gypsum sustained a load of 187*5 pel with a 30 083377 MNP Mr. A. L. Jones 9-16-57 2 redaction in thickness, while the One-Cote Cement formulated with gypsum was able to sustain a load of 189.25 psi for the sane reduction in thickness. An attempt was made to determine if the addition of gypsum changed the setting time of the modified One-Cote Cement formulation. Samples of both formulations were mixed and allowed to set for periods of time up to two hours. As would be expected, both formulations showed a gradual stiffening with time, but both of them were still towslable after standing for a period of two hours. The dried cements in both instances showed similar fall-off in their abrasion resistance and compressive hardness. As all these changes were of the same order we believe that the addition of the gypsum has not resulted in any changes which would be detected during field application. In our report of the characteristics of the laboratory formulated cements with gypsum, we indicated that the substituted formulations showed dry adhesion proper^ ties. The plant batches were evaluated for this characteristic, but no consist ent adherence to metal can be reported from batch to batch or even within a batch. At times Carico would report that the sample he tested stuck to a steel surface. Sherwood found the same characteristic of adhsrance, but these results were not consistent and we hesitate to claim that One-Cote Cement, with gypsum, has the property of dry adhesion. As a final point of evaluation, Carico examined the formulations containing gypsum for the possibility of rust formation whan the samples were applied to steel. Following our standard procedure used in testing this characteristic in Super "66" Cmnent, he found that the addition of gypsum did not result in s emsent that caus ed the formation of rust on the steel surface to which it had been applied. Regular One-Cote Cement has never showed any indications of promoting the rusting of s steel surface. Our evaluation of the plant batches confirms in every respect the results we obtained through our laboratory evaluation. It is our opinion that gypsum can be safely substituted to the amount of 18 lbs. for an equivalent weight of white Portland cament in our One-Cote formulation. We believe that this substitution should be used until all the molding plaster now in inventory la consumed. In the meantime we will study the benefits which might be derived if gypsum were to be added to our One-Cote formulation as a standard ingredient. As of this writ ing we have yet to hear from the 0. S. Gypeum Company regarding the samples of various gypsums which we requested for our testing program. A letter has also been sent to Certain-Teed Products Ccmpany in order to obtain samples of the various gypsums which they manufacture. As results from our additional laborat ory work become available wo will keep you advised. PLL/s cet Mr. 01en J. Chrlstner MT. Larue Cook ^ Paul L. Loose 083378 UHR 000228