Document BbXR7ObjqK9XJ3En65eV1o4X
722,
Chapter 41____________ ________
1945 Guide.
Drying time as determined by. test is 2 hr (Fig. 8). Cores weighing 6 tons, and 15-ton steel plates, trucks etc. are delivered to the dryer at 70 F. The. oven is. heated by an external heater; the products of combustion and 66% per cent recirculated air will be delivered to the oven at 825 F.. Fuel oil of 19,980 Btu gross and' 18,830 Btu- per pound net heating value, weighing 6.75 lb per gallon and having 15 lb product per pound fuel. for perfect combustion. Cores consist of 91 per cent sand, 3 per cent oil binder, and
6 per cent water. '
Solution. Heat required per ton of cores:
Lb Material X Temp. Rise X Sp. Ht . =
Sand__________________ ___ 0.91 X 2,000 X (400 - 70) X 0.2
=
Binder____________ .________ 0.03 X 2,000 X (400 - 70) X 0.4
Water heating._.:_ 0.06
X 2,000 X (212 - 70) X 1.0
=
Water evaporation 0.06 X 2,000 X
970 (Fig. 6)
=
Water superheating (approx. 50 per cent reaches 575 F) = 0.5 X 0.06 X 2,000 X (575 - 212) X 0.45 =
Btu 120,120
7,920 17,040 116,520
9,800
Total Heat______________ _____ _______________ -____________ 271,400 Btu
Heat in 1 lb fuel oil Heater Loss (10 per cent) Duct Loss (5 per cent)
= = 1883 = 942
18,830Btu 2,825Btu
Btu available to heat oven
16,005 Btu
Heat content of gases in 1 lb fuel oil at 825 F is 205 Btu
Sensible heat in products ofperfect combustion = (15 lb +205) = 3,075 Btu
Btu to heat air X and (Fig. 9)..
= .'
12,930Btu
Y (So* - Sm) '+ X (Sm. - Sn) = 12,930 Y = 2 {X + 15) for 66.7 per cent recirculation
(6)
where S = heat content of air at temperature noted taken from Fig. 6.
(Recirculation and exhaust contains water vapor, products of combustion, and a greater portion of air. Heat capacities of all vary so little that they have all been assumed to be air).
Sen -- Sot = 190 -- 91 =99 Sm - Sn = 190 - 8.6 = 181.4
Substituting values of Y, H, etc. in Equation 6,
(2 X + 30) 99 + 181.4 X = 12,930 X = 26.3 lb excess air. y = 82.6 lb recirculating air;
.
Total = 26.3 + 82.6 + 15 '= 123.9 lb air and products of combustion circulated per pound fuel burned.
Heat in air exhausted from oven at 422 F per pound fuel burned = 0.333 X 123.9 X (5 - Sn) = 41.3 (91 - 8.6) = 3,400 Btu.
Btu available for heating material = 16,005 -- 3,400 = 12,605 Btu per pound fuel.
Fuel used in first hour = 2,180,470 -5- 12,605 = 173 lb = 25.6 gal.
During the second hour the heater capacity will be much greater than required. If an automatic oven temperature control operates on the oil supply, the delivery tem perature of the air entering the oven and the quantity of oil burned will decrease, the air supply being constant.
Heat in,air exhausted ='41.3 (Sm -- Sn) -- 41.3 (127 -- 8.6) = 4,880 Btu per pound fuel.
Heat available for heating material = 16,005 -- 4,880 - 11,125 Btu.
Fuel used in second hour = 1,072,008 = 11,125 = 96.5 lb oil = 14.3 gal.
Total oil used per load = 25.6 + 14.3 = 39.9 gal.
.Drying Systems .
723 t.
- Heating Load First Hour
Hzated to
212 F
Binder3....................... .......... Water........
Superheat..... .......... ........
212 F
212 F 66.7% 66.7%
Total Per Ton.........
For 6 ton Steel plates
Radiationb______ _________
390 F 422 F Avg
142 33^ X 120,120 142 33Q X 7,920
0.667 X 116,520 0.667 X 9,800
.=
,=
= = =
Btu
51,688
.
3,408
17,040 77,680 1
6,530
l Sfi-Ufi
6 X 156,346
320 X 30,000 X 0.12
352 X
856 X 0.30
= 938,076 = 1,152,000 = 90,394
Total.......
7 180 470
| '
j '!
Heating Load Second Hour
Sand________ _____;.............. 400 F
Water.___ __ ___ __ _____..... Evaporation
"400 F
33.3% 33.3%
1 9ft
3^ X 1 QO 330 X
120,120 7,920
0.333 X 116,520 0.333 X 9,800
Total Per Ton...............
= 68,432
" 4,512
= 38,840 = 3,270
115 054
Radiationb
6 X 115,054
= 690,324
460 70 -X 30,000 X 0.12 = 252,000
575
505 X
856 X 0.30 = 129,684
Total.--,------------....------------ ;.............................................. ...._.............................. 1'072,008
Binder oxidizes and liberates heat, which is neglected in-this calculation. ^Average value of coefficient is less than 0.3 because oven is not up to 575 F. This is neglected. 422 F is arrived at by taking area under curve as compared to area under 575 F ordinate.
ESTIMATING METHODS
Values based on practical experience are available for rough estimating of drying problems. The temperature will drop approximately 8.5 F per grain of water evaporated per cubic foot of air (measured at 70 F) or approximately 0.62 F per ppund of air at any temperature. Air will drop 55 F per cubic foot for. each Btu extracted. Generally air will absorb from 2 grains to 5 grains per cubic foot of air in one passage through an air dryer, depending on the temperature and the degree of contact with the material. The amount of steam required to evaporate a pound of water will vary from 1.5 lb to a more usual figure of from 2.5 to 3 lb of steam per pound of water evaporated.
REFERENCES
Drying Apparatus, by H. C. Russell (A.S.H.V.E. Transactions, Vol. 18,1912, p. 76).
Commercial Drying Apparatus, by L. P. Dwyer (A.S.H.V.E. Transactions, Vol. 22.
1916, p. 479).