Document BRo1pJVOoD5vw19p1758NZRr4
%
Air Conditioning, Automatic Heating Systems
Gilbert & Barker Mfg. Company
Springfield, Massachusetts
New York City Springfield,Mass.
Chicago, III.
Pittsfield, Mass.
Rochester, N.Y. Detroit, Mich.
Branch Offices:
l&iiMrco
Toronto
London Paris
Vienna Sydney
Buenos Aires
OnJJBOTNG-ARGONMTIONlNG
GILBARCO FLEXIBLE FLAME OIL BURNERS
"Gilbarco" Flexible Flame Oil Burners are of the pressure atomizing type, suitable for
residential and commercial use in steam, hot water, vapor, or warm air heating systems.
Their operation is fully automatic with controls and safety devices integral with the
system. Due to the flexibility of the flame, the
"Gilbarco" Burner is enabled to more completely fill
the fire box with a heat-giving radiant flame.
Each "Gilbarco" Burner combines the following
definite advantages: (1) Flexible Flame with "Econ-
O-Flex" controlled combustion--assuring tailor-made
application. (2) Forced draft--insuring complete com
bustion. (3) Radiant type flame-y-gives great heat
Model GB9
output. (4) Constant electric ignition. (5) Separate
air and oil controls--insuring complete combustion.
(6) Oil filter in oil line--assuring clean oil at all times. (7) Radio interference eliminator.
(8) Burner installed outside boiler insures long life, easy inspection and service and
general operating efficiency. (9) Quiet operation--no gears, belts or noisy mechanisms.
SPECIFICATIONS OF AND CAPACITIES FOR 60 CYCLE MOTOR BURNERS
(Write to us for capacities of D.C. and odd cycle motor burners)
MODEL NUMBER Mu. oil Capocity per boor.
U. 8. CaUooa Total Stan P .{I.Am.
(Radlattos, piping, and pickup) Total Hot Water Radiation
(Radiation, piping, and pickup)
Motor (ttxe)
Control*
RPM
CB1 3.00
1150
IMO
Continuous Made
tiudomcr I/ll H. P. Stack Derated Protectorday and Tbermpatat
1750
CB2 63
23S0
3760
Conttauotu electric Made
trandarcxr i/a h. p. Stack awaited Protectorday and Thcnaoetat
1750
CBS 113)
4400
70*0
Continuous electric Made
mufonner 1/6 H. P. Protcetarday Prateeteetat and Tbtnnoetat
1750
CB4 153)0
6000
MOO
Cratinnoiu two
transformers 1/4 H. P. Ptotectorday Protectostat and Thermostat
1750
CBS 253)0
10000
163)00
Coatisoocta electric two
transformers l/S H. P.
Ptotectorday Pretectoetat and Ttenwui
1750
GILBARCO HEAVY OIL BURNERS-- Complete Range for Industrial Heating and Power Application
GILBARCO SERIES "A6" BOILER BURNER UNITS
Three models for both steam and hot water in the " A6'\series which range in capacity
from 548 ft to 860 ft of steam radiation (gross) and 876 ft to
1376 ftof hot water (gross). The boiler,
especially designed for oil fuel, is of cast
iron, which can be molded into effective
types of heat-absorbing surfaces. "A6"
series models are completely automatic and
the high efficiencies which are attained in
the boiler are due to the fact that the heat
gases are compelled to be in direct contact
with the heat-absorbing surfaces at all
times. All series "A6' Gilbarco Boiler
Burner Units are designed to include:
Built-in hot water coil and Aquastat; Low-
water Cut-off on steam systems; Insulat
ing Refractory combustion chamber, Pres- Cutaway view showing
Outside view of the " A6" Series GUbareo Boiler Burner Unit. Furnished in two-tone
green with chrome trim.
suretrol on steam systems; Surface Aquastat on hot water systems.
904
^tehm o^deofibinl^
trek lighting of burner compart ment. Gauge* easily read through
ventilator openings.
Gilbert & Barker
Air Conditioning, Automatic Heating Systems
Unit No.
A6--19 A6--20 A6--22
GILBARCO SERIES "A6" RATINGS
SQUARE FEET STEAM RADIATION
Cross
Without
Water Coil Net
With
Coil Net
With Special
Coil
Net
SQUARE FEET HOT WATER RADIATION
Without Water Coil
WHb Coil
With Special
Coil
cTM.
Net
Net
Net
DOMESTIC WATER CCKL CAPACITIES GALLONS OF WATER IN THREE HRS.
100*F. Temperature Rise
Steam Boilers it 180*F. Averace Temp.
Hot Water Boilers at 150* F. Averace Temp.
Standard Special Standard Coil Coil Coil
548 3SO 321
291
876 560 539 514
40
80
20
40
700 450 416 391 1120 720 692 674 45 80 224 40
860 S50 515 491 1376 880 8S3 834 SO 80 25 40
SERIES "A6" ^DIMENSIONS
nn
._L_.
A B c D E| ? C H i E L M w R S T
A6--14 57 H
47M 44H
SHAt-- S7H
47K
SiA6--22 57 H M 4754
2H SIM 2M SIH
lift
2H SIH ISA
98 9
7H SH
MM S4H
;
34
I6H m. 56
2-2 H 2-3 2-3
4
I3M MM ISH
GILBARCO SERIES "BF" BOILER UNITS (Oil Fired)
There are five models for both steam and hot water systems in
the " BF " series which range in capacity from 780 to 2030 sq ft
of steam (gross) and equivalent in hot water (gross).
Like the "A6" series
the boilers of the "BF"
series are of cast iron
construction insuring
peak efficiency and great
durability. The specially
designed boiler combines
the following important
efficiency factors: (1)
Extended fin type heat
ing surfaces. (2) Low
draft loss. (3) Large
combustion chamber. (4)
" BF " Series Gilbarco Boiler Unit. (Oil Fired) Furnished in twoAone
green with chrome trim.
Quick steaming. (5)
Water-backed combus tion chamber. (6)
Showing con struction and gas travel. Gages visible through lou
Ground joints between vers in door.
sections, (7) Unique gas travel. (8) Positive internal water circulation.
(9) Large
steam liberating surface. (10) Compact size.
GILBARCO SERIES **BF" RATINGS
SQUARE FEET STEAM RADIATION
SQUARE FEET HOT WATER RADIATION
DOMESTIC WATER COIL CAPACITIES. GALLONS OF WATER \N THREE HRS.
I00*F. Temperature Rise
Grow
Net
Unit No.
BF--3 BF--4 BF--5 BF--6 BF--7
780 1095
.1405 1720
2030
Water Coil
500 700 900 1100 1300
Coil
428 628 828 1028 1228
Coil
384 584 784 984 1184
1248 1743 2248 2752 3246
Net
Without Domestic Water Coil
800 1120 1440 1760 2080
Net
With
Coil
740 1060 1380 1700 2020
Net
With
Coil
706 1026 1346 1666 1986
Boilers at INTF. Averace Temp.
Boileraat 150* F. Averace Temo.
With
With
With
Standard
Water Coil Water Coil Water Coil Water Coil
100 100 100 100 100 '
160 160 160
160 160
50 50 50
50 SO-
80 80 ' 80 60
80
Note.--Gross rating is the total output in square feet of radiation at the boiler nozzle. Net ratings represent the allowable standing cast iron radiation which can be connected to each boiler when the domestic hot water load is as shown at the top of each column. No deduction for the hot water coil, regardless of storage tank size, should be made from the net rating, since the maximum load imposed by each coil has already been deducted. Efficiency---Series "A6" Boilers show a test efficiency of 77 percent, Series " BF"
(See also Page 906)
905