Document BRjzge8b3QO0gj20Rd8REyOwJ
MQNS 0VJ413
COMPANY CONFIDENTIAL
Distribution:
APPROVAL OF SAFETY REVIEW COMMITTEE
Technical Information Center - St. L (2)
Security File - St. Louis
J. E. Smith - St. Louis
G. L. Jessee
J. L. Corder
G. W. Miller
. H. E. Schulte
.
'"Technical Services (3)
D. Danna ~ St. Louis (3)
Plant Standards Dept. (Extras)
Signed by H. E. Schulte H. E. Schulte
Signed by P. K. Ward P. K. Ward
J. C. Landwehr J. C. Landwehr
.
MONSANTO COMPANY ANNISTON PLANT 28 JUL 70
TENTATIVE AMENDMENT "C" ` ' ' TO AROCLOR BLENDS - STANDARD MANUFACTURING PROCESS
Dated August 1968
TITLE:
PRODUCE VARIOUS BLENDS OF AROCLORS 1221, 5432, 5442 AND 5460.
OBJECTIVE:
Make Aroclor blends to replace the plasticizer grade Liquid Aroclor8 which will be discontinued 31 Aug 70.
PRESENT PROCEDURE: These blends are not presently made.
PROPOSED AMENDMENT: These blends will be made in the 2000 gallon blend tank by adding the two ingredients in their approximate proportionate weights. Agitation, sample analysis, and further adjustments will be made to get the blend to meet the tentative specifications. The blended batch will then be drummed for storage and/or subsequent sales.
M0NS 099*15
Tentative Amendment "C" Aroclor Blende Standard Mfg. Process dated August 1968
Initially the following blends are expected to be made:
Approximate Blend Name________________________ Composition
___________ Replaces
Aroclor 6090
90% 5460; 10% 1221
Aroclor 4465
Aroclor 6070
70% 5460; 30% 1221
Aroclor 1260
Aroclor 6062
62% 5460; 38% 1221
Aroclor 1254
Aroclor 6050
50% 5460; 50% 1221
Aroclor 1248
Aroclor 6040
40% 5460; 60% 1221
Aroclor 1242
Aroclor 4272
72% 5442; 26% 1221
Aroclor 1254
Aroclor 3270
70% 5442; 30% 5460
Aroclor 4465
Further blends may be required to meet marketing needs under this proposed amendment and will be done so as the need arises.
SOURCE OF DATA: 1.. Letter J. W. Baker to J. T. Bell, 15 Jul 70 2.. Letter w. S. Clark to A. W. M. coaker, 10 Jul 70
SAFETY:
This proposed amendment will not affect the safety of the Azoclor department.
QUALITY: The properties of the blends will be measured against the tentative specs issued 7/27/70.
EXTENT OF TRIAL:
Six months will be needed to work out the proportions of the ingredients for each blend necessary to meet
the desired sales specs. Research will be contacted for any changes necessary to produce a more marketable product.
Originated by:
:kd MQNS 04.941b
Tentative Amendment "C" Aroclor Blende Std. Mfg. Process Dated August 1968
3.
APPROVALS:
Department Supervisor; Prig, signed by G. w. Miller____________ G. W. Miller
6/17/70 Date
Production Superintendent: Prig. signed by J. L. Corder______ J. L. Corder
8/31/70 Date
Plant Manager:
0rl<?-
b* G- L- Je8aaa________________ G. L* Jessee
8/31/70 Date
PR6D Group Leader:Prig, signed by J. L. Brown_____________________ J. L. Brown
9/1/70 Date
Research Group Leader:
Prig, signed by J. W. Baker________ -J, W Bafctr 1 L K L o>
9/10/70 Date
Mgr. of Research a Dev. :
Prig, signed by M. W. Farrar M. W. Farrar M ' *L '?
9/14/70 Date
Manufacturing Manager:Prig, signed by J. E. Smith/J. R. Savage 9/13/70
E .'Smith
Date
MQNS 04941?
HONS 049418
MONSANTO COMPANY ORGANIC CHEMICALS DIVISION
ANNISTON, ALABAMA
STANDARD MANUFACTURING PROCESS
FOR
AROCLOR BLENDS
.
Department 826.47
Prepared by: M. J. Williams Prod. Foreman
Reviewed by: R. A. Haydel Prod. Supervisor H. L. Williams Prod. Superintendent
Issued: August 1968
COPY NO. jC
CONFIDENTIAL INFORMATION This process is the property of Monsanto Company and the recipient is responsible for Its safekeeping. It contains confidential information of Monsanto Company which must not be reproduced, revealed to unauthorized persona, or sent outside the Company without proper authorization. Either retain in a secure file or return to the Standards Department.
MCNS 049419
STANDARD MANUFACTURING PROCESS FOR
AROCLOR BLENDS
DISTRIBUTION
Technical Information Certter~St. Louis Research Security File Technical Production Manager Plant Manager Production Superintendent Production Supervisor Maintenance Superintendent Technical Service Department Files Plant Standard Department
2 copies 1 copy 1 copy 1 copy 1 copy 1 copy 1 copy 3 copies 4 copies
mons 049420
STANDARD MANUFACTURING PROCESS FOR
AROCLOR BLENDS
TABLE OF CONTENTS
SECTION I
SYNOPSIS OF PROCESS
SECTION II
FLOW SHEETS
SECTION III
PROCESS IN DETAIL
A. Pyranol Mixes Produced
B. Mix Tank Area
SECTION IV
COMMENTS ON THE PROCESS
APPENDIX - A. B.
C.
D. E. F. G. H. I. J. K. L. M. N.
Equipment List Finished Goods, By-Product, and Raw Material Specifications Physical Constants for Finished Goods, Intermediates and Major Raw Materials. Utilities Personnel Packaging and Shipping Material Balance Atmospheric & Stream Discharge & Waste Disposal Process Control Procedures Safety & Toxicity Data & Accident Reports Background Information Time Cycles Quality Considerations Miscellaneous
MONS 049421
COMPANY CONFIDENTIAL
TMl COW f?
Distribution t
Technical Information Center - St. L (
Security Pile - St. Louis
J. E. Smith - St. Louis
G. L. Jessee
J. L. Corder
G. W. Miller
H. E. Schulte
,
Technical Services (3)
D. Danna - St. Louis (3)
Plant Standards Dept. (Extras)
APPROVAL OF SAFETY REVIEW OOfMITTEE
Signed by H. E,. Schulte H. E. Schulte
Signed by P. K., Ward P. K. Ward
J. C. Landwehr
J. c. Landwehr
MONSANTO COMPANY ANNISTON PLANT 28 JUL 70
TENTATIVE AMENDMENT C" TO
AROCLOR BLENDS - STANDARD MANUFACTURING PROCESS Dated August 1968
TITLE:
PRODUCE VARIOUS BLENDS OF AROCLORS 1221, 5432, 5442 AND 5460.
OBJECTIVE: _
Make Aroclor blends to replace the plasticizer grade Liquid Aroclors which will be discontinued 31 Aug 70.
PRESENT PROCEDURE: These blends are not presently made.
PROPOSED AMENDMENT: These blends will be made in the 2000 gallon blend tank by adding the two ingredients in their approximate proportionate weights. Agitation, sample analysis, and further adjustments will be made to get the blend to meet the tentative specifications. The blended batch will then be drummed for storage and/or subsequent sales.
HONS 049422
Tentative Amendment "C" Aroclor Blende Standard Mfg. Process dated August 1968
2.
Initially the following blends are expected to be made:
Approximate Blend Name________________________ Composition____________________Replaces
Aroclor 6090
90% 5460; 10% 1221
Aroclor 4465
Aroclor 6070
70% 5460; 30% 1221
Aroclor 1260
Aroclor 6062
62% 5460; 38% 1221
Aroclor 1254
Aroclor 6050
50% 5460; 50% 1221
Aroclor 1248
Aroclor 6040
40% 5460; 60% 1221
Aroclor 1242
Aroclor 4272
72% 5442; 28% 1221
Aroclor 1254
Aroclor 3270
70% 5442; 30% 5460
Aroclor 4465
Further blends may be required1 to meet marketing needs under this proposed amendment and will be done so as the need arises.
SOURCE OF DATA: 1,. Letter J. W. Baker to J. T. Bell, 15 Jul 70 2. Letter W. S. Clark to A. W. M. Coaker, 10 Jul 70
SAFETY:
This proposed amendment will not affect the safety of the Aroclor department.
QUALITY: The properties of the blends will be measured against the tentative specs issued 7/27/70.
EXTENT OF TRIAL;
Six months will be needed to work out the proportions of the ingredients for each blend necessary to meet
the desired sales specs. Research will be contacted for any changes necessary to produce a more marketable product.
Originated by: :kd MONS 049423
Tentative Amendment "C" Aroclor Blends Std. Mfg. Process Dated August 1968
3.
APPROVALS;
Department Supervisors Orig. signed by G. W. Miller G. W. Miller
8/17/70 Date
Production Superintendent: Orig. signed by J, L. Corder J. L. Corder
Plant Manager:
Orig. signed by G. L. Jessee G. L. Jessee
8/31/70 Date
8/31/70 Date
PR&D Group Leader:
Orig. signed by J. L. Brown J. L. Brown
9/1/70 Cate
Research Group Leader:
Orig. signed by J. W. Baker J. W. Baker
9/10/70 Date
Mgr. of Research & Dev.:
Oriq,. signed by M. W. Farrar M. W. Farrar
9/14/70 Date
Manufacturing Manager:
Orig. signed by J. E, Smith/J. R. Savage 9/13/7
J. E. Smith
Date
HONS 049424
Distribution: .
COMPANY CONFIDENTIAL
Technical Information Center - St* Louis (2) Security File St. Louis J. R. Savage - St. Louis C. L. Jessee H. L. Williams R. A. Heydel H. E. Schulte Technical Services (3) Plant Standards Department (Extras)
MONSANTO COMPANY ANNISTON PLANT March 17, 1970
TENTATIVE AMENDMENT "B" TO
AROCLOR BLENDS - STANDARD MANUFACTURING PROCESS Dated: August, 1968
TITLE:
Produce Inerteen 54201-A9 by blending Aroclor 1242 and TCB In proportions such that final blend is approximately 65% 1242 and 35% TCB.
OBJECTIVE:
To produce new blend for sales.
PRESENT PROCEDURE:
Blend is not presently made. However, it will be similar to Inerteen 54201-A6 except that the components will be blended in different ratios.
PROPOSED PROCEDURE:
Aroclor 1242 and TCB will be blended in an agitated, aluminum tank to produce a blend which is approximately 65% Aroclor 1242 and 35% TCB, Actual ratios of the components will vary somewhat in individual blends depending on exact composition of the components. Upon producing each individual blend, control analyses will be run in the Lab to assure material meets specs before packaging for sales.
HONS 049425
-2-
80URCE OT DATA; Lab made pilot bland of the A-9 and developed the tentative epeca baaed on analyaea of thla pilot blend.
SAFETYi Thla proceaa has no affect on the safety of the operation*.
QUALITY I The quality of each batch produced will be lab monitored to Insure shipment of ih spec material.
(K*, # "H R. A. Haydel Department Supervisor
/md
APPROVALS:
Department Supervisor _
Production Superintendent
S'17-7a Date
Plant Manager
_
3-/7-7Q
Research Manager
Master copy signed W. R. Richard
3/27/70____
Technical Prod. Manager
Master copy signed J* R Savage
V2/7fl_____
HONS 099926
STANDARD MANUFACTURING PROCESS FOR
AROCLOR BLENDS
AMENDING RECORD SHEET
Amendment No.
To: Std. Monufacturing Process
Title
MOMS 049427
HONS 049428
SYNOPSIS OF PROCESS
STANDARD MANUFACTURING PROCESS FOR
AROCLOR BLENDS
SYNOPSIS OF PROCESS
Production of Pyranols is a blending process. Distilled Aroclors,
and other raw materials, are pumped to one of two Pyranol mix tanks.
These raw materials may come from a filtrate tank, storage tank,
tank car or drums. Each mix tank is equipped with an agitator for
thorough mixing of material.
'
.Quality of a Pyranol mix is analyzed by the laboratory and when in specification it Is loaded into tank cars or drawn into suitable contalners.
HONS 049429
FLOW SHEET
HUNS 049430
STANDARD MANUFACTURING PROCESS FOR
AROCLOR BLENDS FLOW SHEETS
HONS 049431
ethei? POXUBE TouuENe XYLENE
ocDwins
Y. V fctf ..DATE $ ] $ . } $ & XSUBJECT. Y . K A N P A ^...... > i - e . w b s .......
CHKD- BY.......... DATE........................................................................................................................
? f M M SNOW
SHEET NO JOB NO
k.
o
MONS 049433
PROCESS
DETAIL
STANDARD MANUFACTURING PROCESS FOR
AROCLOR BLENDS
III. PROCESS IN DETAIL A. Pvranol Mixes Produced
Most Pyranols are produced by the mixing of distilled Aroclor with various other row materials. Some of the Pyranols ore treated with attapulgus earth and filtered prior to loading for shipment. There are three Pyranol blends that are produced by the mixing of distilled Aroclors only. The Pyranol area is actually a part of the Aroclor Department and all Pyranol mixes are made by the Aroclor operators. The quality of each mix is analyzed by the laboratory and when approved it is loaded into tank cars or drawn out into drums. See Table I for raw materials and quantity of each used in the production of each product or mix. B. Mix Tank Area There are two mix tanks used in the production of Pyranol mixes. One is a 12,000 gallon tank and the other i6 a 2,000 gallon tank. Each tank is equipped with an agitator to assure good mixing. Each tank is also equipped with a steam coil to provide desired tem~ perature. Sales demand for some of the mixes does not warrant production of large batches which accounts for the second, or small mix tank. All mixes produced in the large tank are filtered through a Sparkler filter. Mixes produced in the small tank are not treated with attapulgus earth and are packaged in drums only and filtered through a diaper cloth sock on the end of the draw-out line.
MO NS 049434
PRODUCT
1254 - 10X Toluene
ARO.X 1242
ARO. X 1248
1260 - 10X Toluene
1262-10% Toluene
1262-10% Xylene
Pyranol A13B3B
Inerteen PPO
Inerteen 54201-KA
Inerteen 54201-CM
100.00
Inerteen 54201-A-6
Therminol FR-0
Therminol FR-Lo Temp.
Santicizer 794
75.00 80.00
50.00 ! i 50.00
Aroclor Blend
Aroclor Blend
28.00 72.00
ARO. X 125*
90.00
70.00
85.00
ARO. X 1260
ARO. X ARO.%
%
1262
4465 Toluene
10.00
% Xrlene
X PPO
X TCB
X TTCB
X EARTH
X EP221
90.00
10.00
90.00
10.00
90.00
10.00
*5.00
55.00 0.03
0.125
60.00
0.20 40.00
0.01
'i 0.20 30.00
0.03
0.20
0.01
ii i i j
i
50.00 j I
I
j
i
i
1
15.00
|
25.00
0.01
20.00
50.00
Xo ____
i !i
YS 049435
!
ii
COMMENTS ON PROCESS
HONS 049436
STANDARD MANUFACTURING PROCESS FOR
AROCLOR BLENDS
COMMENTS ON THE PROCESS Do not allow temperature on mix tanks to exceed 120C. TCB and TTCB will begin to vaporize above this temperature.
The large pyranol mix tank Is calibrated In outage whereas other tanks are calibrated In Innage.
All drums filled with pyranol mixes containing toluene are stenciled TOLUOL rather than toluene.
When a tank car Is loaded from the large pyranol mix tank samples are taken from the car and analyzed for lot number. If the remaining material In the mix tank la drawn out in drums then samples must be taken from the drums and analyzed for another lot number. The area where pyranol mixes are produced is considered a part of the Aroclor Department and these mixes are made by Aroclor operators.
Each car of TCB and TTCB must be analyzed and approved by the laboratory before being used, to prevent high chemical instability in the finished product. Special precautions are necessary when making Inerteen 54201-KA:
1. TCB ia earth treated to bring power factor below a value of ten. 2. TCB plus 1254 mix is earth treated until power factor Is below a
value of one.
3. Ether is added only after earth has been filtered out and filter cleaned.
4. Tank car is loaded only when power factor has a value of three max.
5. Most important, nitrogen is blown into mix tank through the bottom nozzle during the earth treatment to supplement the extremely poor agitation system presently employed.
HONS 049437
0VJ43B HONS
HONS 049439
STANDARD MANUFACTURING PROCESS FOR
AROCLOR BLENDS APPENDIX A - EQUIPMENT LIST
HONS 049440
Appendix A - Equipment List
Item 205
206 643
Equipment
Equlo.No.
South (large) Pyranol Mix Tank
22-0108
North (small) Pyranol Mix Tank
Pyranol Filter
15-0029
1
Description 14'-0" l.D. x 10'-0" high. Dug. D-6455 zinc-tin lined carbon steel.
6'-6" l.D. x 8'-2" jacketed 316 S.S. tank
Model 18-S-23 horizontal plate type 304 S.S. w/scavenger plate feature on pipe legs. Purchased from Sparkler Mfg. Co.
Other equipment used In the production of Pyranol mixes is considered Aroclor equipment.
MONS 049441
MUNS 049442
APPENDIX B - MATERIAL SPECIFICATIONS
Finished Goods
Material Code
Product
826.64 826.59 826.61 826.56 826.58 826.49 826.81 826.90 826.89 826.12 826.41 826.13 826.85 826.88 826.03 826.78 826.79 826.87
Aroclor 1254 - 107* Toluene Aroclor 1260 - 107, Toluene Aroclor 1262 - 107, Toluene ArOclor 1262 - 107. Xylene Pyranol A13B3B Inertecn PPO Inerteen 54201-KA Inerteen 54201-CM Inerteen 54201-A-6 Thermlnol FR-1 Therminol FR-2 Thermlnol FR-3 Thermlnol FR-0 Thermlnol FR-Lo Temp. Therminol 66 Santlclrer 794 Aroclor 1254 - 4465 Aroclor 1242 - 1248
5MT0l*A*3
moms 049443
APPENDIX B MATERIAL SPECIFICATIONS
II. Raw Materials Material Code
Product
826.12 626.41 826.13 826.14 826.IS 826.19 58900 64020 36100 60200 58500 19400 61325
Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1262 Aroclor 4465 Toluene Xylene Phenyl Glycidyl Ether Trichlorobenzene Tri-Tetrochlorobenzene Attapulgus Earth EP-221
HONS 049444
HONS 049445
APPENDIX C - PHYSICAL CONSTANTS OF FINISHED GOODS. INTERMEDIATES. AND MAJOR RAW MATERIALS
MONS 049446
Monsanto
I MOM iNAMt A
TO
>0*1 St. Louis - General Offices
January 26, 1956
Wootlnghouuo Inerteens
0. Axcell - Los Angeles K. Buddy - KBUDD L. M. Cleric - Houston R. Crabtree - Atlanta ' B. Dolimount - Pittsburgh A. Eckersley - Toronto R. Ehrhardt - New York L. Erman - Detroit M. Fitzgerald - Everett H. W. Hayden - HHAYD J. Hendricks - Cleveland C. Heybruch - Cincinnati R. Mulholland - RMUX.H V. Oliver - Pittsburgh M. Penn - Chicago F. Perkins - Minneapolis J. Rltt - JRITT W. Stewart - WSTEW F. Stupfell - Seattle J. Tannehlll - Santa Clara M. J. Tingle - Wilmington
copies for,' /*, c. <*fay
A^ COf//*am J
,c P. G. Bcnlgnus H. S. Bergen - IIBEKG
. J. Bonavoglia - Nov; York R. Damlanl - Chicago H. Day - HDAY D. E. Krlksen - Los Angoleo G. Fague - Detroit G. R. Graham - New York H. L. Gray - Anniston D. A. Hall - Cleveland H. C. Hamll - Atlanta D. L. Hosmer - Chicago W. G. Martin - Nev: York D. T. Mayer - WGK R. C. Meyer - Cincinnati G. Miller - Anniston R. Kuster - WGK T. Oneson - Montreal D. R. Pogue - Los Angeles J. Rains - WGK H. Ray - WOK D. Samford - DSAMF
_^-MvT i"Wh 1 te - MWHIT . ^^,,11. Williams - Anniston
"hTC'. Carder' - HOARD ......... W. B. Papageorge - Anniston
WeBtinghouse is now purchasing a number of our Aroclors and blends, all under the common name of Inerteen 9A201.
To differentiate between the various capacitor and trans former fluids, Westinghouse simply uses letters following the above number to signify the different types.
We are concerned that this common number showing on orders coming to us from Westinghouse may result In confusion and uncertainty as to which product is needed, and it
might result In wrong product being shipped by mistake.
To assist In avoiding such possible errors, the following definitions of the various products may be helpful:
Weatlnghouae Name
Monsanto Name
Uae
Inerteen 5^201 CC .
Inerteen PPO
Product Code: 1090-200-lS-03/09 Transformers
Composition:
Aroclor 1260 60#
TCB 40#
PPO
0.2#
MONS 0*9*4?
Wcstinchouse
-2-
January 25, 1953
Westlnfthouse Name Inortr.on 54201KA
Inertoen 54201 CM
Xnertcen 54201 Clv Inerteen 5420IA6
Monsanto Name
Iricrteon 70-30 Transformer
Product Code: 1050-210-16-03/09
Compos! tlon:
Aroclor 1254 70#
TCB
305?.
PPO 0.2?5
Inertoen 100-42 Transformer Product Code: 1050-215-16-03/09 Composition: Aroclor 1242 lOOJa PPO 0.2/
Aroclor 1242 Product Code: 1040-240-16-09 Composition: Aroclor 1242 10055
Inertoen 75-25 (Capacitor) Product Code: 1060-100-16-09 Composition: Aroclor 1242 75?5
TCB 2555
Use Trans former
Transformer
Capacltors Capacitors
It is recommended that future orders to plants show both Wcctint;houoe and Monsanto names for the Individual products:
Monsanto
WestlnKhouse
Inerteen FPO
Inerteen 7O-3O Transformer (1254-TCB)
Inerteen 100-42 Transformer (124 2-PPO)
Aroclor 1242 (Capacitor) Inerteen 75-23 (Capacitor)
(1242-TCB)
Inerteen 54201 CC Inertoen 54201 KA
Inerteen 54201 CM
Inerteen 54201 CF Inertoen 54201 Ao
/Jm
C. M. WILLIAMS
HONS 049448
r.-lonsanto
7'/t' cc-f\
C. K-. /',/:<
.n.hcst, Louis - General Offices
April 13, 1959. ThERHINOL S3
TO Anniston Harris Powell
II. J. Day - HDAY
J. R. Fallon D. E. Roush D. Gamford - DSAMF
S. Shaw M. T. White - HWHIT
^----ir.^m 11a ms - Anniston I;,.
Confirming our phono conversation, THERMINOL 33 is a new heat transfer* media being offered; and you villi bo receiving orders for this product.
THERMINOL 83 is Santowax R; however, we must be extremely earoful that all container markings and shipping papers on orders calling for THERMINOL 83 identify the product as THERMINOL 88 only. Any slip can jeopardise the special pricing for this product.
Product code - 7795-033-11-09 has been assigned to THERMINOL 38.
Marketing tentatively plans to offer this product in:
75 lb. net paper bags 225 lb. (51 gallon) lever-pak drums
which will conform with your Santowax packing.
We appreciate your assistance In protecting the identity.
/jm
HONS 049Vt9
Din art
PHYSICAL CONSTANTS DATA
mtmtt----^--1
....... .........
- tTnueruRAL rottMuu*
1
AROCLOR 1262_______________________________________
GbO
tOMPTtYD IV A'. M Ellenbur?
DATE 7/3/57
ciT
NAME
SOURCE & DATE
Formula Molecular V/elchl
C12H3CI3------- :_______________ -3S.5______ _____ __ ___ ____ ,____
Ltpht veil, sticlcv Resin
Bellini Point at 760 mm
390-425C__________________
Bollltil Point al mm_______________________
Monsanto Bulletin OP-115 " ` (1856
Uniting Point at mm
Boiling Point al mm_______________________
Civstalllzino Point
llUltinf Point
.
Solution Point Soecllic Gravity 9 0 /15. 5 C Soecllic Gravity * 25/25uC Pounds par Gal. as C
Coefficiento(Exoanslon 2S-fi5C
1.577-1. 587
Specs. 4/11/55
1.646
.JVUB-OP^-LS
13.72____________ ____________ 0.00064 cc/cc/C
fl
Refractive Indexs P.B0C " S mire Red Sooctrum preference;
1.648-1.650 _____________
Ultra Violet Spectrum (Reference)
Viscosity r
210F
. 86-100 SUS_________________ Specs. 4/11/55______________
Viscosity * Suisea Tension Solebllitv In Water Solubility lo
Solubility In______________________________
Flash Point 6F method) Fire Point C Heel of Combustion Hsat of Formation
Thermal Stability (cal.Ae/min.) Latent Heat of Fusion Latent Heat o( Vao. Soecllic Heat Critical Temocratuie Critical Ptessute Dissociation Constant Po:r Point
None None
35-38C
MB OP-115 II
M5 *
0
1
6
MONS 049450
'
Toxicity fGivc Hefercncc)
Contact Med. Dept.
MB OP-115
NOT G: Theft dnta should not he released outside of Monsanto Chemical Company. Use additional sheets if necessary.
k.,, PHYSICAL CONSTANTS DATA
IBUt'Au........................
i Unoy
' ..
(kc^c^o X\epOXft
tQHPflTE&W ,,i '
- ^ '
VtrtAUPT *y-S-6&
NAME
Formula
Molecular Welsht
1
Aonairancfi
Bolllne Point at 760 mm Bolllnz Point at m
<o,o) mm
-
'
Rallln* Point at mm
Boltina Point at win_______________________
Civstallizlne Point
Mnltln; Point____________________________
Solution Point
.
Soacllle Gravity a z<?/ zs 'C
Sooolllc Gravity Pounds tat Gal. <r
2.0 * C
Coefficient ol Exoansion
Rotisctlve Index a
i
Infra Red Spectrum (Refmnct)
Ultia Violet Spectrum mttvmct)
Vlicoalty________________________________
yiiwiitvi _
Saltace Tension
______ ________________
Solablllty In Water @ ZOC.____________
Solubility In
SToluObilitty Ibn k M -z.2-1
_
tTMUCTtlNAL FORMULA Q . -0>
OATC
o (C* Ht^CHrOC-O/Ct. H6)0
252.'Si
^J
"3 `54 C
: ZO"C
SOURCE 6 OATE IfEF 1
RTef -1
- ZC> 'C.
1, l-^SO 9,76
EiTl filEF 1
o. o 1
%,
2. 6 mjI <7o
|ceF i ETF1
" "
Filth Point F method) t levs Oynxt Cup Fir* Point C
Nut ol Combustion Hut ol Formation Thernai Stability (cal.Aa/min.l Latent Heal ol Fusion
Latent Heat ol V.
SmcIIIc Heat Critical Temperature Critical Pleasure Dissociation Constant
Jfoo^
Heferer.ee:-; Bl X/9&7tb -F/m pfioPS > ........ ........ ...
aM
US i 0
tox CltV (Civ* Reference)
U/JIOJJ CARiiibS CHE.I ICAJ-S *
HONS 0t9<*51
_
PHYSICAL CONSTANTS DATA
mamra --------------------------
---------------
* t RUC T UHAL FOKMUL A
'AO l UBMB ____________
Z M TM V/- liCA'V.eAJE
TtfSMutcnrrtr'
V|\ai>rr J>-ts
r
NAME
Formula
..__ X~c.6-U''^ c
Mo ecular Weiplit
AmIMUKfi________________ Polling Point al TCP mm_______ _____
Ccu Lo llc.s "C
WWW Point A mi- O.bY. v.v
_________'S.H
_____________
BollinifataUi____mm 40, TO vtjjtv_______
S 9, 1 c C.
Bolling Poinl al mm 90.00 UK
"C
Crvstelllzlnn Poinl Mailing Point
- s5 *
Solution Point
Specific Otayliy.* a/`t *_<=
Soeellic Gravity o
Po nils pci Cat. n
Coilfldont ol Expansion
Refractive Indexa
n2
Wl Rtd SPCCtIUm (Rcfctenct)
y
Ultra Violet Spectrum /Reference)
CM.
. StOeU-ReCipE 6VDATE
iCcrl feer.F i
E-avl tEr.r / \tcr 1
~ ` "
fef-T 1 fer. t 1
" 1
VlKOtUyg___ Xllcosily* Sul aoLTinslon___ 5e!i'fe!L<ly_!iLVi*tcr
Solubllilv In _ SSLdsltltvIn Ai-conou
, Err.r'e
feCF <
Tkorritivniev TPT.
EXW.pCIVE /.IMIT* Vo vou Flash Poinl F akmi O i-r,t' C.: pv>
Plra Point C ttSJ l ol Comhustion Hu of Formation Thermal Stability (cel.Aru'min.1 inenl Heat of Fusion utent Peal ol Ve?.___________ Soocllic Ileal
Cfllicol Temperature Critical Pleasure Dissociation Constant .
~\e?.S "W
),2 7 - 7, O -
feEFT TSi-tr?
KEF f
'
Reforer.ces:
tn
V
4, p
/.AiMtfCtS HtWistePK. or CylS.M|or,.'-V
L ..
___`.
i O
Toxicity /Give Rcfcrrnct)
:
pnNS 049452
PHYSICAL constants data
IrtAwittV1*--................
.................. """"
ivriweiuHAL roniiuw* C OYflpUSlrtiJII --------*
TR1-TETRA BLEND .
.
1, 2, 3, 4-Tetra 1, 2, 4, 5-Tetra
26-29% 0- 3%
cmMcnm-------
f D, K .Lynch . .
1 " NAME foimula tbltculu V/eif.ht
hlljfli Pdlrl tt 7r0 r.m
o*n _J2yJ.5i.54
Penta
0- 5.5%
Trichlqrbenzene Remainder
_Sy.S.t.iJ'Lo Afi&f _VL
... ._.
M__ixture
eojinfig r. oatk
"
--Sgefi-LUfinUop_____________ __ .
W W t Inn Id_____________ .. (GE.material D5 B 691 ?,10-270C.
Bhilln Point N mm foilin? Polnl urn fjyitilliiin? Point
-15UC. (Max '
___
Mrtion Point InecllicGravity *
r 15,5/15. 5~C,
bocllle Gravity * Pwfldl pw Gol. 4 15 FC
Coelllclont ol Em:.i:ion Mrocllvo Intox 25UC." i infra Red Socctium
Util Violet Spoetnra (Rriamctl
ViKDCfly * VIlCOlltY * IhiImi Tfcn<*lnn
'fallibility In Btlct___ Mitllitv In Jstubllilv In
,,.
or
... _
1.510-1.520
1.5775- 1.5790 --
...
---------
--
Ink Point *F HUM)
ire Polnl 'C
ell ol Coninirtlcn
tit ol Fwattlon
ffluiJl StcbJIlty (eil.A/piln.)
flint Hist of Fusion
ktnl Hot! ol Vro.
bslfie Mstt
filMlTcisorrttuie Uietl Pi&mho
.
tloelrtlon f.Ni.ljrl
--
None to H.P.
. ______ ------------------- -----------------
.
y ............
1 1
,
: '
a /
r_ MONS 049453
L
MySCiytRrittmtt) Sax, Handbook < f Dangerous Materials _Rr inhold. N.Y. 1051
L.. *" "* *UD.
3G. ,\J C. A. S.D. Sheet 54. 1953.
Cl
i>AJA_SHEET NO^JOO-D_
HOOKER SPECIFICATIONS
Description Freezing Point Distillation Range Specific Gravity, 1 5. 5*C/1 5, 5aC Moisture Content
Clear, almost colorless liquid 1 0*C max
5*C max, including 216#C 1.460 to 1.475 0. 05% max
DESCRIPTION
Hooker Trichlorobenzene is a technical grade material being a mix ture of 1,2, 4 and 1, 2, 3-trichlorobenzenes. It is a clear, almost colorless mobile liquid having a characteristic chlorobenzene odor.
Formula
C^HjClj
Molecular Weight
181.5
TYPICAL PROPERTIES
Freezing Point
0C to 5C
Distillation Range
5 *C between the limits 21 3* and219'C
Decomposition Temperature
300 + C
Color (APH)
20
Flash Point (Cleveland open cup)
240"F
Fire Point (Cleveland open cup) Specific Gravity 1 5. 5C/1 5, 5*C Density Correction Factor per 1 C
None up to boiling point
1.466 .00124
MONS
049434
POHM IIU-C
Tha pr.ianl.d hafalR, wtiila a*1 avafe.U.d, li I. Ih. b.tl af aw haawladaa (>wa and atmi.t. N. w.rranlf at t.aiaaiaa aiptau ar Inpllad ii mada raiwdla* tha parlatiRinca a< liability *1 an, p*adtd. ilnta tha m*a> .1 uta and taadlllani al tiara,a and handli.i ora bayaad aar canlral. Na tatatilaR far prd<l via. nai aayihlnt tanlalnad haal, ihail ba tamirvad 01 a r*<a"<**"deilan (at ill vt* ( Mrin#aidRt ! any anlillRI palaat.
Trichlorobenzene, Tech.
-2-
DS No. 700-D
Refractive Index, n20/D
1.570
Pounds per Gallon at 15.5*C
12.2
Specific Heat at 25 *C *
0.20
. Latent Heat of Vaporization *
54 cal/gm (98 BTU/lb)
Boiling Temp at 501b gage
280*C
Surface Tension at 25*C
38. 9 dynes/cm
Coefficient of Cubical Expansion at 30*C
.00086
Viscosity
Gentistokes
Centi poises
at 100'F at 210"F
Vapor Pressure U) at 100*C
1.100 0.549
2 3 nun
1.579 0.746
Solubility at 25 C Water in Trichlor Trichlor in Water Acetone Benzol Butanol Carbon Tetrachloride Diethyl Ether Ethylene Dichloride Linseed Oil Methanol Petroleum Ether Solvesso No 2
* Literature data
gms/j 00 gms 0. ZZ 0. 0025 Completely miscible
HONS 049455
Trichlorobenzene, Tech.
-3-
DS No 700-D
USES 1, I, 3,
4.
Insecticide: particularly effective as a soil poison in termite eradication.
Solvent: for fats, oils, waxes, resins and as a crystallization solvent.
Heat transfer medium; its physical properties indicate that it is particularly adaptable to condensing vapor systems for a range of from 210*C to about 300*C. It does not leak through ordinarily tight pipe joints. Tests indicate that at 200C its corrosion of iron amounts to less than 0. 125 mm/yr. It is also recom mended as a dielectric fluid for transformers.
Chemical synthesis: used in manufacture of dye intermediates and other organic chemicals.
PRECAUTIONARY INFORMATION
The following precautions for handling trichlorobenzene are quoted from our package labels* This caution label has been prepared in accordance with a pattern established by the Manufacturing Chemists' Association.
''CAUTION! VAPOR HARMFUL. Use with adequate ventilation. Avoid prolonged breathing of vapor. Avoid prolonged or repeated contact with skin. "
Mlt. 11-187-3
MONS 04945b October, 1961
" ^ J J ,**4 ; i! ^
/*<* *^st^ iP\t i1 O ij j*.' -\.,ii.\,---i-!-r-
T8W?*SNii,""--r"-------------
tTKUCTuft L FOfiVULA
AVirrt i~>-: '>h9 - 10% Toluol Mix
Mixcure by Weicb'.
(
w.rivrci'jr.'i' /.. M. Ei:.^:-.b-rs;
re "uln
iawskrCeM &r r; '>ir'
Ifti rri!:.; / Tl' rrv
Boi i.v- f\v' : : rrn _
rH'!ni Pr-iv
fn,s
o.; ini
;i rn
>5:nl ....
&-V.
;f
Sjs:!!fC"..-:.'
/.n/1S Rur>
Si:
niiiCui. u 25 C
CC3uicicr! c.! I^cnsic:.
Rs.'tEitIve 1."a-
3
1,.:. (!ii
riMxnf)
liift. $r.irjja
V!ce&s?i**
inn0*'
Vitae!'." s
SiO0?1 ____ __
*
If' :'!> in . Si: \y.y :r ^ * j* t :)li!t'' :n
o - r
OATS 1 7/2/S7
' i S.vTim 'iLiciild
1.497-1. 516________ 12. 7
ins S os 1477 R1IS1 4. 5 cs. Ml SUS1
0C
90% - Arcelor 1232 10% - Toluol
SOURCE & DAT"
1 I Sr>Pr
' / F.S
i " n
WGK MLr.fc 3l/l8/56
WGK Lh l?,/5/'.B_______
i
Fit ,1. ?t::,l
?ir
Vf.7 ooer. cuo }| If H
d Oc.?:-r::n
: c.- Fc.-
>.
./v.-..',................
ll:^Kjrt.s!-:!6S
105 _JLLQ__________________
1
i -,,
II
11 ff
.
1
.......................
L^:r.tXifU?Vn.
s:if!c ca lr* r/ 1 p;
.riJrs
.... . _______
J 1
. -
'
nis<fi:ir:in 8.\*>:ri_ . ..
* 1
1
.1_______________________________ _ !
1 Ji 1
'
n
, o -----------' .>
'O
1 i
`
Yb* icit" (C:vj Avkrsnsc) _____
______ 1_________________________________ L________________________
)\ v 1 --' ! Thrt,t Jr.iu ;i).ou!f?'n/i Ai r.'^rrr&.! n
r i.,-f .......... ...
0
v.. r
0.0620 t
t
`i""'
THERMAL CONDUCTIVITY
~r w
-1
I
k Sjt
-- -
!-
--
c;
--
V ... -
--
* -
rj n. >>
V* N
-
jJ [Mt
*v
=
-4*
1 THERMINOL FR-1 2 THERMINOL FR-S
" ' .............. ' " v
nT -
-
P1
4i J
i is
S <>
c
1~ s
--
Os t:.. rs -
*
i i >
,,
iS
3iv
-S L_ rv
-
wo ?:+. 300 400 ` TF.MPEr.MURE *F.
500 600 MONS 049459
6
jlSCOSUTY-TEi'.'yERATURE CHART
ABSOLUTE YICSO SITY, CEMTtPOISES
;
j
SPECIFIC G R A V ITY --G M S /C C .
D E N S ITY --L R S ./F T *
DENSITY AND SPECIFIC GRAVITY
CSC
SSSLSLU1,
1 THERMINOl FR-1
2 TKERMINOl FR-2
3 THERMIKOL FR-3
i
33 SJ
\TN
0 100 200 300 400 500 600 TEMPERATURE *F.
HONS 049*60
PROPERTIES IMPORTANT TO HEAT TRANSFER DESIGN
THERMINOL PR-1
'
' Teinpe rature
, *F.
C.
60 j 100 ! 150
; eoo i too : 000 ! 350
: 400 , 450 ! 500 350
. 600 ! eso : too
10.0 37.6 66 63 121
m 177 204 232 260 too 316 343 371
Enlholpy BTU/Lb.
4.856 16.68 32.65 48.07 63.50 79.45 65.94 112.66 130.46 146.52 107.08 186.16 205.76 225.62
Specific Heat Thermal Conduct. BTU/Lb--F. BTU/Fl!, Hr., F./Ft.
0.272
0.282 0.261 0.3047 0.3151 0.3255 0.3359 0.3464
0.3568 0.3672 0.3770 0.3880 0.3985 0.4089
0.06098 0.06060 0.06021 0.05976 0.05927 0.05675 0.05319 0.05760 0.05897
0.05630 0.05560 0.05487 0.05409 0.05329
Density Lb./Gal.
11.033 11.453 11.216 10.961 10.760 10.523 10.296 10.055 9.833 9.601 9.370 9.136 8.906 8.675
i THERMINOL FR-S
Viscosity Lb./Hr--Ft.
745.36 56.144 15.972 8.2431 6.5270 3.4158 2.4753
USSft 1.5028 1.2351 1.0428 0.90031 0.79166 0.70731
Vapor Pres, mm. Hg. Absolute
10 27
65 143 291 550
16.6 psle 31.9 pale
-
1 1 '
j
\ Tempi rature
* *F.
c.
< 60 ; 100 \ 160
M0 260 t too ! 350
i 400 450 600
: 660 too 650 700
10.0 37.8 60 93 121 149 177 204 232 900 268 316 343
371
Enthalpy Spoclflc Heel Thermal Conduct. DTU/Lb. BTU/Lb--*F. BTU/Fl!, Hr.,*F./Ft.
4.69 17.61 31.09 45.11
69.43 74.14
89.20 104.81 120.74
137.08 153.85 170.99 103.58 203.45
0.257 0.265 0.274 0.2B40 0.2922 0.3003 0.3084 0.3166 0.3247 0.3396 0.3410 0.3491
0.3573 0.3054
0.05861 0.05852
0.05801 0.05788 0.05748 0.05703 0.05655 0.05603 0.05548 0.05488 0.06424 0.05357 0.05286 0.05211
Density Lb./Gai.
12.225 12.000 11.760 11.525 11.293 11.062 10,830 10.588 10.367 10.135 9.903 9.672 9.440 .9.208
Vlsoosity Lb./Hr--Ft.
7090,0 151.01 27.83 11.971 6.949 4.531 3,201 2.399 1.881 1.529 1.2795 1.0971 0.9596 0.8536
Vapor Proa, mm, Hg. Absolute
6 15 37 84 173 340 615 20.3 pal*
Tempi future *r. c.
60 too ISO ' too 250 300 360 400 <60 600 660 600 60 700
10.0 37.8
66 83 121 149 177 204
232 260 233 316 343 371
THERMIWOL FR-3
Enthalpy Specific Heat Thermal Conduct. BTU/Lb. BTU/Lb--*f. 3TU/Ft!, Hr., *F./Ft.
4.28 16.37 29.08 41.95 55.36 69.20
83.46 96.15 113.26 128.77 144.73 161.11 177.92 192.24
0239 0.245
0.256 0.2629 0.2714 0,2799 0.2864 0.2989 0.3054 0.3138 0.3223 0.3308 0.3393 0.3478
0.05700 0.06680 0.05634 0.05520
0.0659B 0.05558 0.0S513 0.05468 0.05415 0.05360 0.05309 0.0f/41
0.35176 ',55107
Density Lb./Gal.
13.002 12.760 12.634 12.292 12.061 11.829 11.597 11.366 11.134 10.902 1M71
15.139 10.207 9.97C
Viscosity Lb./Hr--Ft.
_
1628.6 101,64 24.262 12.091
7.116 4.669
3.306 2.476 1.937 1.669?
1.309S 1.1168 0.97531
Vapor Pres. mm. Hg. Absolute
3 9 24 55 <1/ * *23 413 735
HONS 049461
Introducing Therminol FR-O...
Newest member of the growing line of Monsanto heat transfer fluids. Thcrminol FR-0 was formu lated specifically to eliminate freeze-up during cold weathor shut down for in-transit heating of sulfur, pitch, asphalt, naphthalene, bunker "C" fuel oil, and high melting resin materials. Therminol FR-0 eliminates the need for high temperature reheat ing in order to pump out the material at its destination. Low temperature pumpability makes it ideally suited for space healing applications, outdoor plants in Northern climates, or in any application where good fluidity at low tem peratures is a prerequisite.
Fire-Resistance...
Therminol FR-0 permits installation of a nonpressurized system operating with a liquid that has no fire point, and will not support combustion
I... so fire-resistant, Therminol fluids have achieved
recognition by Underwriters' Laboratory, Factory Mutual, and Factory Insurance Association. Be cause of this extreme fire-resistance and its listing by insurance companies, important savings can be made in designing a process heating system around Therminol FR-0 fluid.
Chemically Speaking...
Therminol' FR-0 fluid Is a chlorinated biphenyl, manufactured under exacting process control to rigid specifications for long term thermal stability, specific heat, thermal conductivity, vapor pressure and viscosity. The liquid is an oily, clear, nearly colorless, fluid with a pour point of -15*F and a minimum pumpablc temperature of -5"F.
Therminol FR-0 fluid is recommended for use up to 600F and will not show measurable change after years of exposure to such temperatures. The fluid is non-corrosive with all common motals used in heat transfer system designs.
Prtpirty Kinematic Viscosity, ci. Ssyboft Viscosity. SSU Vigor Pressure, mm H, Specific Hest, BTU/lb." Therjnil Conductivity, BTU/*F.FLHf.fc Density, |/cr. Density, lbs./jil.
TYPICAL PROPERTIES OF THERMINOL FR-0
" ` *........ ' * ' * `
Ttmprture, F
-f +10 40 100 ZOO 800 400 100 600
4545 1007 92.55 8.10
1.70* 0.95
-
-
-
20850
4640 429
52.43
7.99* 4.54
-
-
-
- - - - 1.35 13.00 76.0 315 915
- - - 0.27 0.29 0.31 0.33 0.35 0.36
-
-
--
0.061
0.060
0.059
0.058
0.057 0.056
- 1.45 ' 1.43 1.40 1.34 1.28 1.23 1.17 Ml
- 12.10 11.92 11.70 n 19 10.69 1(127 9.76 9.27
HONS 04946^
VAPOR PRESSURE
/
THERMAL CONDUCTIVITY (calculated)
VAPOR PRESSURE, r r m He
100 200 300 400 500 600 Temperature, *F
DENSITY
*> *e/.. .** #V-
/ 1*-.
100 200 200 400 500 "430 Tempers'.'."''. *'r
HONS 049463
SPECIFIC HEAT
0
KINEMATIC VISCOSITIES
Temperature, *F .
HONS 049464
j
THERMINOL* FR Lo-Temp Vapor Pressure
Introducing Therminol FR Lo-Temp
Therminol FR Lo-Temp is our newest fire-resist ant heat transfer fluid formulated specifically for practical pumpability at -40F.
This low-temperature fluid permits installation of a non-pressurized system operating with a liquid which has no fire point and will not support combustion.
The recommended operating range of Therminol FR Lo-Temp is -- 40F to 400F. It will not show measurable change after years of exposure at such temperatures.
The fluid is a chemically inert, noncorrosivc com pound with a pour point of -- 60F and a vapor pressure of only 300 mm of mercury at 400F.
Listed as a fire resistant heat transfer media by Underwriters Laboratories, it can be installed for a wide range of uses in both space heating and cooling, gas processing and distribution, and in dustrial heating and cooling under conditions of low ambient temperatures.
TYPICAL PROPERTIES
Composition
Appearance
Pour Po/nt Flash Point Flame Point Autoignition Temperature Boitlng Ranj'e' ' ...............
Chlorinated biphenyls and hydrocarbons
Oily, clear, nearly colorless liquid
-60 f. 280 F.
None lo boiling Over 1100* F.
" 432-F. --627*T."'* v "
)
'3
THERMINOL* FR Lo-Temp Thermal Conductivity
HUNS 049466
-- V hs _ J--L
-- VI
-50 0 50 100 350 200 250 300 350 00 Temperature --*F.
J
F. *C. ^0--^5
60--r
M
r--15
O 20 <*7
57
30 4 O3
)
'I
140 60
160 HMo
80 iso
J~S0
too--1
1 WATER 2 NITROBENZENE 3 CHLOROBENZENE 4 BENZENE
3 TQ.ULEM. 6 CARBON TETRACHLORIDE
7 METHL B ETHYL ALCOHOL 8 n-OCTANE 9 n-HEXANE
1 70
k- HONS
h
.'--7s
049468
)
; Flguie 23.1. Surface tension of s-me common U- tlds. vReproauced by permission British Chemical Engineering ' Vtft. 4, page 38, copyrfght 1958.)
TbU 22.1
X AND Y VALUES FOR SURFACE TENSION NOMOGRAPH
Qompaund Aeelal Aaetajdeftvda AMloldetlm*
Sir3s.s
ir.i 8ft
78 187
111002..5ft
189
IS. 10111
IS 103
18 M11l1.fIt
171.
84.4 1SS.0
H15.I4 SI.6
SO
iS.S lift IS.7
14ft. ft 7.2 107 .ft 108 lift 107.4
118
117.8
111084. ft
108 101.8
184
UIS S
i> 101
is.s
190.S 180.8
i?,.a.
is
148. S
IftS
US
08.4
u1.4..Sz
138
07 Iftl
S.1I :1* .IS*
80.0 08.7
ST.ft *>.*
ss.s
I
1So1rt3.8
S3
88 IMSOS
48
Si:!
8.VO
&
84
4ft.S 44
83.0. 38.8
8*
07
ss
is
i5
180.1
*8 s0o .8
103. S 134.8 ISO
m.s
180 113
8814f2t..8ft
or
S7.I 191.1
I138S3.S
ill *
ISO .1
tis
117
55
Temperature In Degrees C
MiwAf Z-t.
88*1, are uaed for any particular compound to (Iva a
point on tha central |no. tain* thia point aa a pivot for a atralcht line, the value of the * *toee tanaton may tea toad front he Intersection of this line with the t acalc aaainal tha
value of the temperature read from the Interaeetlen of thia |-- ~th h* T aril*
HONS 049469 Figure 22.1. Surface tension of liquldi au a function of temoer-'lure ;.?eproduced by permission, Industrial 6 Engineering Chemistry, Vol. 40, page 886, copyright 1948, The American Chemical Society.)
p-nwo
.&-*)**
/ ^YDROCARBON
/\
PTftOLEUM\\
riQwr* 28.1 Nomogroni fr vapor pressure, lalenl heat, end other physical properties
m end C, found from tob.2ftl,ef from experimental vulvet f vopor pressures of two points or et on point ond the valve of latent hcat. locol o point on tho grid, through which o lint It drown to Intersect on tho itfl scale vopor prei> uro, end on the right scale, tho corresponding lomperalvre, flvot point* of oil hydrocarbon* toll clot* to tho doihtd Hfti across the control grid, ond only one vopor pressure__ o.g.. Iho boding point---or latent hoot to give m, li nece*> ory to define the system. Pivot point* f oil petroleum mixtures, etudes, fractions, or residues foil dote to the petro leum mixture line oeross the central grid, this defines lo the equilibrium flash vopgrizoilon relation.
JP- 1,000
Toluene
pXvLENB n XySENO O XYL6NB
i> ..
1.2,H TCB J,2,3.*tTBTRA.CB
1.2 .St.'STIctkaCB'*
HONS 049470
jw-B"
Figure 28.1. Nomograph for vapor pressure, latent best, and other physical properties. (Reproduced by permission Industrial & Engineering Chemistry, Vol. 49,- page 125, copyright 1957, American Chemical Society.)
Pith
You can choose from seven Therminol fluids with a combined operating range from-40F.to more than 700F. No pressurization needed!
All Therminol fluids work without pressure over the enlire operating range. You save on construction, expensive monitoring and safety devices needed in high-pressure systems. With Therminol, you're assured of uniform, safe and economical flows to single or multi-users.
You can gel two big jobs done at once by delivering high heat for processing or
moderate heat for space heating lines. Because these fluids are noncorrosive,
nonvolatile, thermally stable and chemi cally inert, properly maintained equipment can operate for years with no make-up.
Therminol fire resistant (FR) fluids are the only heal transfer fluids listed by Under writers' Laboratories and recognized by the FIA and FMA.
Call on our engineers for prompt, com plete advice and technical service whore you havo a heat transfer problem, Circle the reader service card for morn informa tion. Detach this chart and keep it tor your permanent reference.
(See our oxhibn 4336 at the 31 st Ex position of Chemical Industries. Nw York Coliseum, November 27-Dccember 1.)
RetommanBid Uss Hanft
Pear Point
Vapor Prostate at Man. Recent. Tamp.
U.L. Listed
MB 700
-60'F
-157
27
197
300 mm Hg
yes
315 mm Hg
yes
550 mm Hg
yes
340 mm Hg
yes
507
225 mm Hg
yes
-15" to -187 457
525 mm Hg 168 mm Hg
no--C.O.C. Hash point 3507
no --C.O.C. flash point 4607
HONS 0*9hli
Introducing two new heat transfer fluids from Monsanto
Now you get even greater high and low range capabilities!
Thormlnol FR Lo-Temp. Our newest fire resistant fluid. Gives you a low-cost, liquid phase indirect heat transfer system with extremely good low-temperature pumpability and sub-zero mobility to -40*F. Yet it can be opereted up to 400'F, is ideal for space healing end cooling.
Thermlnol 66. Our most volatile and efficient fluid
meets your needs for higher processing temperatures at low cost. Operating between 16`F and 660*F without pressure, its heat transfer properties are 10% better then other fluids in this range. He - 15'F to -18'F pour point permits start*up et fluid temperatures as low as 15*F.
For properties of ell seven Therminol fluids, turn the page.
HONS 049473
THERMINOL FR LO-TEMP FIRE RESISTANT HEAT TRANSFER FLUID
... (he fire-resistant, low-temperature liquid phase heat transfer fluid with very low temperature pumpability.
TECHNICAL BULLETIN (T-LT)
FLUIDS
MV MMM. MMMNTO KAMI M VAMAHTIII TO TH( flTMtl 00 NtMNMTUHm
AT T NOOUCll KMHtt TO, w (MftMM (t MtMwhrr 'muM lw fHm mm cm-
miwm. wild mmwiny r
Imx mmm"
OffMh DMm/IOI k IMtoiili IM/tl Uuk Miami 111(1
--------------------------------------------------
HONS 049*79
THERMINOL* FR Lo-Temp Vapor Prooturo
Introducing Therminol FR Lo-Temp
Therminoi FR Lo-Temp is our newest fire-resist ant heat transfer fluid formulated specifically for practical pumpability at -- 40F.
This low-temperature fluid permits installation of a non-pressurized system operating with a liquid which has no fire point and will not support combustion.
The recommended operating range of Therminol FR Lo-Temp is --40F to 400F. It will not show measurable change after years of exposure at such temperatures.
The fluid is a chemically inert, noncorrosive com pound with a pour point of -60F and a vapor pressure of only 300 mm of mercury at 400F.
Listed as a fire resistant heat transfer media by Underwriters Laboratories, it can be installed for a wide range of uses in both space heating and cooling, gas processing and distribution, and in dustrial heating and cooling under conditions of low ambient temperatures.
TYPICAL PROPERTIES
Composition
Appearance
Pour Point Flash Point Flame Point Autoignition Temperature Boiling Range
Chlorinated biphenyls and hydrocarbons Oily, clear, nearly colorless liquid --60 F. 280 F.
None to boiling Over MOO F.
432 F. - 627 F.
THERMINOL* FR Lo-Temp Thermal Conductivity
HONS 049475
THERMINOL* FR Lo*Tsmp Specific Gravity
THERMINOL* FR Lo-Tomp Specific Hast
-75 -25 0 2550 100 150 200 250 300 350 400 Tsmpsrstors -- F.
THERMINOL* FR Lo-Tomp Viscosity
HONS 049476
i
DISTRICT SALES OFFICES
ALL DIVISIONS
ATLANTA GEORGIA 30326 Lenox Towart Etit 3400 Pttchtrea Pd. N. E. - Salta 1711 1/. (404) 577-2260
BOSTON. MASSACHUSETTS 02149 fwttt Station Tal. (617) 387-5010
CHICAGO. ILLINOIS 3158 Oot Pltintt Ava. Dot Plalnaa. IHinoit 60018 Tal. (312) 296-6688
CINCINNATI. OHIO 4S206 1501 Madiaon Road Tal. (613) 761-6707
CLEVELAND. OHIO 44122 3648 WattanavMa Cantor Pd. Tat. (216) 991-5400
DETROIT. MICHIGAN 48235 600 Northland Towart Eaat Tal. (313) 357-0910
HOUSTON. TEXAS 77002 1300 Main Straat Tal. (713) Cepkol 3-4011
LOS ANGELES. CALIFORNIA 90022 6670 B. Flotilla St Tal. (213) 723-2492
MINNEAPOLIS. MINNESOTA 55402 912 Northater Cantor 110 S. Seventh St Tal. (612) 339-4661
NEW YORK. NEW YORK 10017 277 Park Avanua Tal. (212) 922-4111
PITTSBURGH. PENNSYLVANIA 15222 No. 4 Gateway Cantar Bldg. Room 634 Tal. (412) 261-2166
ST. LOUIS. MISSOURI 63166 900 N. Llndbargh Bhd. Tal. (314) Oxford 4-1000
SAN FRANCISCO BAY AREA 2710 lafayatta. Santa Clara. Calif. 95062 Tal (406) 243-0414
SEATTLE. WASHINGTON 98104 911 Waatam Avanua Tal (206) Main 2-4203
SPRINGFIELD. MASSACHUSETTS 01101 730 'Noreattar Ava. Tal. (413) 766-6911
WILMINGTON. DELAWARE 19803 2008 Concord Pika. Fairfax Tal. (302) Olympia 8-6631
MONSANTO, 800 N. LINDBERGH BLVD.
Additional Dlatrict Offleaa ara maintained by:
Agricultural Division
LULING. LOUISIANA 70070 P. 0. Bon 174 Tal. (504) 704-4253
MEMPHIS. TENNESSEE 38)13 1023 Rivaiaida Dnva P.O. Box 13240 Tal. (901) Whitahall 7 3151
Taxtilat Dlvlaion
AKRON. OHIO 44313 3030 Wait Markat St. T*l. (210) 830-7941
ATLANTA. GEORGIA 30303 Atlanta Marohantfiat Man 240 Paachtraa SI..N.W. Tal. (404) 677-2260
CHARLOTTE. NORTH CAROLINA 20202 Wachovia Bank Building 120 Waal Trada St. Tal. (704) 370*9071
ENGLEWOOO CLIFFS. N. J. 07031 061 PakaadaiAva. Tal. (201) 560-2161
NEW YORK. NEW YORK 360 Fifth Ava. Tal. (201) 650*6100
Hydrocarbon* Si Polymgra OiviolonLion OH
EL OORAOO. ARKANSAS 71730 Lion OH Budding Tal. (601) Union 3*3111
JACKSON. MISSISSIPPI 39200 P. 0. Box 10037 Woatland Station Tal. (001) 362-3040
LITTLE ROCK. ARKANSAS 72203 1616 Waat Savantlt St Tal. (801) FrankNn 6-2437
MEMPHIS. TENNESSEE 30113 1023 RhranMa OHva P. 0. Box 13240 Tal. (901) Whitahall 7*3161
Organic Chamleala Dlvlaion (Robber Induatry)
AKRON. OHIO 44311 920 Brown Straat P. 0. Box 2807 Tal. (210) Hamtock 4-1021
ST. LOUIS. MISSOURI S31H
J
HONS 049477
??95M67-a LlTHO IN U.S *.
THERMINOL 77 HIGH-TEMPERATURE HEAT TRANSFER FLUID
TECHNICAL SULLETIN T-77
FLUIDS
hTmum'mdhsamo mmI'm'mhiurns n to tni fhwjs o mi*oufmuht
Of NT MIODVCTl WWMO 10. m--* ithtmum* miiwmilwi
* (MillKWT >*UHI (
*M <*
OrfMlt ONWOH/Iao N. IMtorgh
larri*. Mlwwri UtU
1
~ HONS 049478
MUNS 049577
APPENDIX G - MATERIAL BALANCE Standard and theoretical usages of raw materials for each Aroclor Blend is shown in Figure I.
MQNS 049578
FIGURE NO I
THEORY AND STANDARD USAGE FOR : LBS. PER CWT OF BUND
PRODUCT Aroclor 1254 - 107. Toluene
'
Aroclor 1254 Toluene
Aroclor 1260 - 107. Toluene
Aroclor 1260 Toluene
Aroclor 1262 - 10?. Toluene
Aroclor 1262 Toluene
Aroclor 1262 - 10& Xylene
Aroclor 1262 Xylene
Pyrenol A13B3B
Aroclor 1260 Trl-Tetrachlorobenzene Epoxide 221
Inerteen PPO
Aroclor 1260 Trichlorobenzene Glycidyl Phenyl Ether
Inerteen 54201-KA
Aroclor 1254 Trichlorobenzene Glycidyl Phenyl Ether
THEORY
90.00 10.00
90.00 10.00
90.00 10.00
90.00 10.bO
45.00 55.00 --
60.00 40.00 --
70.00 30.00 --
STANDARD
90.90 10.10
90.90
10.10
90.90 10.10
90.90 10.10
45.45 56.12
0.13
60.60 40.82
0.22
70.71 30.61
0.22
MONS 049579
FIGURE NO. X
PRODUCT
Inertcen 54201-CM
Aroclor 1.242 Glycldyl Phenyl Ether
Inertccn 54201-A-6
Aroclor 1242 Trichlorobenzene
Therminol FR-0
Aroclor 1242 Trl-Totrachlorobenzene
Thermlnol FR-Lo Temp
Aroclor 1242 Trl-Tetrachloroben2ene
Santtcizer 794
Aroclor 1248 Aroclor 1260
Aroclor 1254-Aroclor 4465
Aroclor 1254 Aroclor 4465
Aroclor 1242 - Aroclor 1248
Aroclor 1242 Aroclor 1248
Aroclor 17.60 - 5% Toluene
Aroclor 1260 Toluene
THEORY
100.00 . --
75.00 25.00
80.00 20.00
50.00 50.00
50.00 50.00
85.00 15.00
28.00 72.00
95.00 5.00
STANDARD
2
100.10 0.22
75.75 25.25
80.80 20.20
50.50 50.50
50.50 50.50
85.50 15.50
28.28 72.73
95.95 5.05
MQN5 049580
MONS 049501
APPENDIX H - ATMOSPHERIC & STREAM DISCHARGE & WASTE DISPOSAL
The following is an estimate of the atmospheric and stream discharge from the Pyranol operations.
Toluene
?y,E Atmospheric
Amount Negligible
Xylene
'
Atmospheric
Negligible
Trichlorobenzene
Atmospheric
Negligible
Tri-Tetrachlorobenzene
Atmospheric
Negligible
MONS 049582
MONS 049583
APPENDIX I - PROCESS CONTROL PROCEDURES
Raw materials are analyzed by the laboratory before being used in a Pyranol mix.
Control samples arc taken by the operator from the mix tank at various stages throughout the blending process. These samples are analyzed by the laboratory. The following control tests are performed by the laboratory.
Test
Anniston Analytical Method No.
Specific Gravity Moisture Refractive Index Resistivity Power Factor Chlorides
14-49-54 14-53-54 14-34-54 14-35-57
-014
A complete analysis is run by the laboratory on all final lot samples.
All Aroclor 1242 used in the I-54201-CM blend is analyzed for ICC, HST, and Monsanto Stability to assure top quality 1242 in the blend.
MQNS 049564
MGNS 049565
APPENDIX J - SAFETY 6 TOXICITY DATA AND ACCIDENT REPORTS
Safety of operations in the Aroclor Plant depends on the individual operator. Materials being handled and operations must be observed closely to guard against the following:
Cause and Action to Prevent
1. Chlorine Gas
Chlorine gas is a very toxic corrosive gas. Leaks or high pressure can occur to liberate it.
Action to Prevent:
a. Report chlorine gas exposure immediately for treatment with Antidote. Milk may be used in mild cases to relieve throat irritation. Oxygen from the resuscitator in the Dispensary is available.
b. Keep gas mask in good condition. Keep a good canister in the mask. Use these type masks only in chlorine concentrations to 2-37. chlorine in air.
c. Use a Scott Air Pnk in concentrations of chlorine gas above 37. in air. Three units are available in the Aroclor-Biphenyl Department.
d. If caught in chlorine gas without a mask, hold your breath and go cross wind until you are out of range of the gas. Place a handkerchief over your nose in small quantities of chlorine.
. e. Report all chlorine leaks for repair immediately. Make temporary repairs with tape if possible.
f. In case of a major chlorine leak, the source of chlorine gas must be stopped.
Notify the chlorine plant immeldately if the pressure on the chlorine manifold exceeds 30 psig. Cut off liquid chlorine from the car.
MQNS 049586
APPENDIX J - Safety & Toxicity Data & Accident Reports
2.
Cause and Action to Prevent
2. Thermal Burns
Contact with hot uninsulated product lines at the chlorinators and still areas.
Contact with uninsulated steam lines and open steam.
Contact with hot Aroclors from broken lines or leaks.
Contact with open flames at stills or from heating lines In the department.
Action to Prevent:
a. Know that contact with equipment and product will cause a thermal burn due to the high temperatures. Make changes in operations with this hazard in mind.
b. Know the first aid treatment for burns. Cold Water Treatment (See Appendix A Emergency Section of Operating Instructions.
c. Wear gloves and long sleeve shirt with the sleeves rolled down when operating. Gloves and clothing can make the difference between first and second degree burns.
d. Report uninsulated lines for repair of insulation.
e. Use only steam lines with hose and hose clamps in good condition.
f. The following .operations are hazardous v and should be done with care:
(1) Catching samples at the Aroclor chlorinator circulating lines.
(2) Sampling the Solid Aroclor still receiver.
(3) Drawing bottoms on the Aroclor stills.
MQNS 049587
APPENDIX J Safety & Toxicity Data 6r Accident Reports
3,
Cause and Action to Prevent
3. Explosion
An explosion could occur in the chlorinators by slugging liquid chlorine to the distributor. Slugs of liquid chlorine could react fast enough to cause excessive pressure in the vessel A rupture of the chlorinator could occur.
Action to Prevent;
a. Observe operation of the chlorine vaporizer and do not let liquid chlorine get into Che rotameters. Pipe lines will be frosted.
b. In case chlorine feed lines are frosted, close liquid chlorine feed valve to the vaporizer. Check steam addition to the vaporizer. Do not start up until source of trouble has been located.
c. Do not close valve in water discharge line from the chlorinator coil.
d. Observe temperature of the chlorinator periodically and be sure it is not too hot (180C. maximum),
.
A. Falls
SlLpping on cement floors, stairs, Aroclor on floor, ice conditions; tripping over objects (hose, pipe, valve handles, etc.); or losing footing on ladders, etc., can cause falls.
Action to Prevent;
a. The majority of minor, serious, and nearmiss injuries in the Aroclor Dept, are
, the result of falls. Prevention is always within the ability of the operator by use of expert operating practices.
b. The following items should be done:
, (1) Return hose to rack after using.
(2) Keep operating areas clean of all foreign objects.
(3) Return ladders to racks when not in use.
(A) Keep gloves on and hands out of pockets especially going up and down stairs.
HONS 049588
APPENDIX J * Safety & Toxicity Data and Accident Reports
A.
A. Falls (Contd.) 5. Fires
'
Cause and Action to Prevent
(5) Place guards around any area that presents a hazard that should be guarded.
c. Poor lighting due to burned out bulbs should be corrected at once. Poor light* Ing due to Inadequate facilities should be reported.
d. Spills must be cleaned up Immediately following their occurrence. Report any spill that cannot be cleaned up within the shift to the Chief Operator. Spills are to be reported In the log book.
Fires can occur by:
Biphenyl, Santovax R, or Santowax C ignition.
Chlorine problems In the vaporizer allowing reaction with steam to release hydrogen.
Furnace burner backfire.
Wood, rags, or paper on hot lines.
Sparks from welding apparatus of open flames.
Action to Prevent:
a. Area must be clear of trash or flammable materials. Use trash skips and cans.
b. Smoke only In areas so designated.
c. Use spark producing equipment only with a fire permit and proper Inspection.
d. Use care in lighting gas torch or the still furnaces.
MUNS 049589
APPENDIX J
Safety & Toxicity Data Accident Reports
Cause and Action to Prevent
Fires (Contd.)
e. Fire fighting equipment includes:
5.
O) Two wheeled dry powder units.
(2) Hose house with 200 ft. of hose.
(3) Two dry powder hand extinguishers, One CO2 hand extinguisher.
W Two 3/4" water hoses. (5) Hose connection north of Santowax.
(6) Scott Air Paks.
(7) Fire truck in fire house.
f. Observe visitors In the plant and be sure they observe safety rules.
6. The following is a list of chemicals handled in the Aroclor Plant operations and the precautions to be taken during their handling:
a. Chlorine Gas -
This Is a corrosive gas which Is toxic. Leaks or back pressure can occur and liberate chlorine gas in the area. Operators should have their cartridge type respirators h#ndv at all times while in the area.
If you are caught without a gas mask, and large amount of chlorine gas is liberated, hold your breath and go cross wind until you are out of range of the gas. Once out # of the area, obtain an emergency gas mask and return to the area and correct the trouble.
A victim of chlorine gas fumes must be removed as quickly as possible from the gaseous area. Place patient on his back with head and back elevated. Milk may be used in mild cases as a relief from throat Irritation. If the
patient has stopped breathing, start arti ficial respiration immediately.
b. Biphenyl -
Biphenyl is a flammable material which will burn. Burning should not be done in the presence of Biphenyl or Biphenyl vapors. The melting point is 68.7C., and the auto Ignition temperature is 258C. Inhalation of Biphenyl fumes is not recommended, since it can cause a drugged effect on the person.
MONS 049590
APPENDIX J - Safety & Toxicity Data ((.Accident Reports
6.
c. Santowax lx -
Santowax R is a flammable material which will burn. It is relatively non-toxic to human beings. However, the vapors of Santowax R are irritating to the mucous membranes and bronichial tract. Prolonged breathing of the vapors should be avoided. The melting point is 140C.
d. Santowax C -
Same as Santowax R, since it is the crude material prior to distillation.
e. Ferric Chloride- Ferric Chloride is a black-brown solid. It causes only slightly Irritating effects on the skin or mucous membranes. When heated it will decompose and release toxic fumes of Chlorine. It will react with water to produce toxic and corrosive HCl fumes.
f. Attopulgus Earth > This material is a dried earth. No danger in handling. Wash off with water to clean.
g. Hydrated Lime - No particular hazard in handling this material.
The dust is irritating to the eyes and skin,
and should be washed off with water.
.
h. Crude Aroclors - Crude Aroclors are hot, since all are handled In steam traced or Jacketed lines. They can easily cause thermal burns in contact with the skin. Prior to air blowing, the material has HCl fumes entrained in It which arc irritating to the skin or mucous membranes.
1. Hydrogen Chlorine Gas - This is a corrosive gas which is toxic. , It is irritating to the mucous membranes, to the eyes, and to the respiratory tract. It will react with water to form Hydrochloric Acid.
J Still Bottoms - Fumes from still bottoms are toxic. They
or Residue
are extremely irritating to the mucous
membranes, to the eyes, and respiratory tract.
HONS 049591
MONS 049592
APPENDIX K - BACKGROUND INFORMATION
History of Pvronols (Inerteeos) in Monsanto
Registered trademarks for some commercial brands of chlorinated biphenyls in the United States are the following: Aroclor , (Monsanto Company), Chlorextol (Allis-Chalmors Manufacturing Co.) Dykanol (Cornell-Dubilier Division, Federal Pacific Electric Co,), Inertecn (VJestinghouse Electric Corporation), Noflamol (Wagner Electric Corporation), Pyranol (General Electric Company), and Thermtnol (Monsanto Company). Some other registered trademarks or trade names for commercial chlorinated biphenyls found through out the world are the following: Clophen (I. G. Farbentndustrle A.G., Germany), Fenclor (Caffaro, Italy), Kannechlor (Kanegafuchi Chemical Co., Japan), Pyralene (Prodelec, France), and Sovol (Russia).
Aroclor used either alone or in blends with other materials such as trichlorobenzene, meet the need for a fire-resistant dielectric fluid with a high resistivity, a high dielectric strength, a relatively high dielectric constant, and a very low power factor. By replacing hydrocarbon oil with chlorinated biphenyls or mixtures of chlorinated biphenyls with trichlorobenzene, It has been possible to redesign equipment with a great reduction in size for the same capacity and voltage. At the same time, the fire hazards have been eliminated.
The first production of Pyranol by Monsanto was in 1936 when Pyranol 1488 was made for General Electric Co. These blends have grown through the yoars until there are now (1968) five Pyranol-Inerteen blends made at the Anniston Plant. Table I shows the approximate date when each blend was first made at the Anniston Plant.
History of Thermlnols in Monsanto
Aroclor 1248 has been used as a heat transfer medium since 1941 and In 1963 the name Therminol FR was assigned to Aroclors used as heat transfer mediums. There are now, in 1968, seven types
of Therminol made. Six are made In the Anniston Plant. The seventh (Therminol 77) is made at the J. F. Queeny plant. The various types are as follows:
Therminol FR-1 is Aroclor 1242
Therminol FR-2 is Aroclor 1248
Therminol FR-3 is Aroclor 1254
Therminol FR-0 is an Aroclor blend
Therminol FR-Lo Temp is an Aroclor blend
Therminol 66
is HB-40
Therminol 77
is an Aroclor blend
Table I shows the approximate date when each blend was first made at the Anniston Plant.
MONS 049593
APPENDIX K - Background Information
2.
History of other Aroclor Blends
Various blends are made for specific customer needs other than electrical and heat transfer mediums. The toluene blends were started ten years ago. FMC requires the 1242-1248 blende with viscosity being the critical property. Table 1 shows the approximate date when each blends was first made at the Anniston plant.
MGNS 049594
TABLE X
AROCLOR BLEND STARTING DATES
BLEND [IAME I. Pyranol 1667
PRODUCTION STARTED 1957
' REMARKS
Changed scavenger to CPE from Tin Tetraphenyl and called Inerteen PPO
2. Pyranol 1470
1957
Changed scavenger to EP 221 from Tin Tetraphenyl and called Pyranol A13B3B
3. Pyranol 1681
1957
No longer made at Anniston
4. Pyranol 1488
1957
No longer made at Anniston
5. Aroclor 1254 - 107. Secondary Butyl Acetate
1957
No longer made
. Aroclor 1254 - 107. Toluene
1958
--
7. Aroclor 1260 10% Toluene
1958
--
8. Aroclor 1262 10% Toluene
1958
-- .
9. Aroclor 1262 107. Xylene
1958
-.
10. Inerteen PPO 11. Pyranol A13B3B 12. 1254-4465 Blend 13. Inerteen 54201-KA
July 1958 Jan. 1963 Mar. 1965 Aug. 1965
'-
14. Therminol FR-0 15. Thermlnol FR-Lo Temp 16. Inerteen 56201-A-6 17. Inerteen 54201-CN
Mar. 1966 Feb. 1967 Jan. 1968 Jan. 1968
-
MONS 049595
TABLE II TENTATIVE PROCESSES
1. Therminol FR-Lo Temp
Research Report P-1441 by C. P. Duncker, dated 13 Feb. '67.
2. Inerteen 54201-KA
Research Report P-1342 by J. D. Sullivan, dated 11 Nov. '64.
3. Inerteen 54201-A6
.
First made in Anniston as lab batch (55 gal. drum) 21 Nov, '67 . Plant batch made after letter from P. G* Benignus to H. C. Carder anticipating first order. There is no know Tentative Process for this product.
4. Inerteen 54201-CM
There Is no known Tentative Process for this product. Plant batch made after phone call from P, G. Benignus to H. L. Williams and resultant sales order from Westinghouse.
5. There are no known Tentative Process descriptions for the remaining Aroclor Blends.
HONS 049596
HONS 049597
APPENDIX L - TIME CYCLES A batch process Is used for the production of all Pyranols. See Table II for time cycles and batch weights of various Pyranol mixes. These are normal size batches, however, a batch size might be Increased or decreased depending on need for the material. There are no bottlenecks in the production of Pyranols at the present time. The time required to load a car. approximately six hours, might become a bottleneck if demand for these products should increase.
HONS (H9598
PRODUCT _________________ 1254 - 107. Toluene 1260 - 107. Toluene 1262 - 10% Toluene 1262 - 10% Xylene A13B3B Inertecn PPO Inerteen 54201-XA Therminol FR-0 Santlclzer 794 Aroclor Blend
TABLE IX
APPROXIMATE POUNDS PER BATCH_______________
20,000 Pounds 20,000 " 20,000 " 20,000 " 100,000 " 100,000 " 100,000 " 20,000 " 20,000 " 20,000 "
APPROXIMATE TIME REQUIRED TO PRODUCE & PACKAGE A BATCH 24 Hours 24 Hours 24 Hours 24 Hours 24 Hours 24 Hours 48 Hours 24 Hours 24 Hours 24 Hours
MCNS 049599
HONS 049600
APPENDIX M - QUALITY CONSIDERATIONS Pyronols and Inerteens ore used os copociter and transformer fluids by the electrical industry. The Aroclors used must meet rigid electrical grade specs. The Hooker supplied tri chlorobenzenes (TCB) and Tri-tetrachlorobenzenes (TTCB) are analyzed before use. Power factor is measured to determine the need for earth treatment before use in a blend. As the batch is being made samples are analyzed for the electrical properties as well as the physical properties to determine the necessity of further earth treatment. The other blends are analyzed for physical properties only although all Aroclor 1242, 1254, and 1260 used meet the electrical specs.
HONS 049601
MOMS 049602
APPENDIX N - MISCELLANEOUS Specialized Equipment Iron rust has a deleterious effect on the electrical properties of Pyranols. Every effort is made to prevent rust from coming In contact with the product. The Pyranol mix tank and tank cars are zinc-tin lined to prevent rust. Galvanized* aluminum lines and stainless steel, pumps and valves are used.
HONS 049603
HONS 04960**
Therminol 77 is a liquid-phase heat transfer fluid particularly suitable for continuous use for tem peratures up to 700F. It has been used for several years in commercial scale and pilot plant systems in a diversity of applications; e.g., paint and resin manufacture, high-temperature plastic extrusion, lamination of plastics, chemical processing, labo ratory baths, and thermostatic devices. Unlike Monsanto's Therminol FR line of fireresistant heat transfer fluids (chlorinated hydro carbons), Therminol 77 does not contain halogen and is not fire resistant. The recommended design considerations described in the Therminol FR En gineering Manual, such as flow rate, AT, heat-flux density, etc., are also applicable to Therminol 77. Although Therminol 77 does thermally degrade at temperatures above 700F, it has been used in commercial heat transfer systems up to its atmos pheric boiling point of 830F. Degradation rate is very low at 700F and increases progressively at increasing temperatures. Therminol 77 degrada tion products are predominantly polymers which are completely soluble in the bulk fluid and, therefore, do not form insulating deposits in the system. Degraded fluid is, however, more viscous than fresh fluid but can be reclaimed economically to essentially new-fluid condition.
MOWS 049479
Tamp r 100 210 300 400 500 600 700 BOO
.
Vapor Pronuro (mm Hi)
-
0.27 1.03 9.2 44
168
530
THERMINOL 77 FLUID PROPERTIES
Vliwilty (os) (Lbs Ft-Hr)
181 505
7.78 20.8
2.65 1.50 3.74
0.96 2.28
0.66 1.49
0.46*
0.99
--
OaasHy
(QMS )
'Lbt Qal)
1.152 9.60 1.106 9.26
1.070 1.029
8.94 8.58
0.981
8.16
0.931
7.76
0.885
738
-
THERMAL CONDUCTIVITY
Tamp r too 200 300 400 500 600 700 100
Pour Point Flash Point
Spaalfla Hast (TU Lb) 0.350 0.375 0.420
0.455 0.495 0.530 0.565 0.600
(Cal am, C, aaa)
32.25x10-*
31.40x10-*
30.50x10-
29.65x10-*
28.80x10-
-
-
-
+45F
460*F
<BTU F, Ft-Mr)
0.0781
0.0760 0.0739
0.0719
0.0698
-
-
Fire Point
-
A. 1. T.
Thermal Decomposition*
Thaemal EipansJan, (aa F) 0.00034
0.00037
0.00049
0.00062
540F
HIST 800F
m MUtnifni hf IM .Mimmh AM4 II MmmM >> III* "IMMMI l Cktmul 1*4 t*l*MMD| Ml." IIAMO ll V|l Nt II >i MImM m Ik* IMUMihn it atm* Him 1 Ml M* H| Mi IWMI. m MB mm H| mi MW!.
RUNS 049460
mm Hg
VAPOR PRESSURE HONS 049481
KINEMATIC VISCOSITIES
COEFFICIENT OF THERMAL EXPANSION DENSITY MONS 049482
B TU /W -hrf-ft
BTU/lfc
THERMAL CONDUCTIVITY
Temperature, *F
SPECIFIC HEAT
Inside Film Heat Transfer Coafficlant versus
Flow Rate at 700eF
HONS 049483
Pressure Drop Per 100 Ft. of Pipe versus
Flow Rete at 700F
MONS 099984
DISTRICT SALES OFFICES ALL DIVISIONS
Additional District Office* ere maint*in*d by:
Agricultural Division
ATLANTA, GEORGIA 30326 L*nox Towets Eest 3400 Peachtree Pd. N. . -- Suite 1711 Tel. (404) 577 2260
BOSTON, MASSACHUSETTS 02149 Everett Station Tel. (617) 367-5010
CHICAGO, ILLINOIS 3158 Oet Plaines Ava. Das P/ainas, Illinois 60018 Tel. (312) 296-6688
CINCINNATI, OHIO 45206 1501 Madison Poad Tel. (513) 751-6707
CLEVELAND, OHIO 44122 3645 Warrantville Center Pd. Tat. (216) 991-5400
DETROIT. MICHIGAN 43235 600 Northland Tower* East Tel. (313) 357-0910
HOUSTON. TEXAS 77002 1300 Main Straat Tai. (713) Capitol 3-4011
LOS ANGELES. CALIFORNIA 90022 6670 E. Flotilla St. Tel. (213) 723-2492
MINNEAPOLIS, MINNESOTA 55402 912 Northstar Canter 110 S. Seventh St. Tat. (612) 339-4651
NEW YORK, NEW YORK 10017 277 Path Avenue Tel. (212) 922-4111
PITTSBURGH, PENNSYLVANIA 15222 No. 4 Gateway Cantor Bldg. Room 534 Tel. (412) 261-2156
ST. LOUIS, MISSOURI 63166 800 N. Lindbergh 8Nd. Tal. (314) Oxford 4-1000
SAN FRANCISCO BAY AREA 2710 Lafayette, Santa Clara. Calif. 96052 Tal. (408) 243-0414
SEATTLE, WASHINGTON 98104 911 Western Avenue Tal. (206) Main 2-4203
SPRINGFIELD, MASSACHUSETTS 01101 730 Worcester Ava. Tel. (413) 788-6911
WILMINGTON. DELAWARE 19803 2006 Concord Pike, Fairfax Tel. (302) Olympia 8-6631
LULING. LOUISIANA 70070 P 0 Box 174 Tal. (8041 784-6283
MEMPHIS. TENNESSEE 38113 1023 R.veu.de Oi.. PO Bn 1 3248 Tel- (901) Whitehall 7- 3) bI
Tsxtllss Division
AKRON. OHIO 44313 3030 Wen Maikai St. Tel. (219) 830-7941
ATLANTA. GEORGIA 30303 Atlanta Merehendite Man 240 Peechttaa St.. N. W. Tal. (404) 977-2260
CHARLOTTE. NORTH CAROLINA 28202 Wachovia Bank Building 129 Wait Trade St. Tal. (704) 376-9871
ENCLEWOOO CUFFS, N. 3. 07631 661 Patitadaa Ava. Tal. (201) 668-2161
NEW YORK. NEW YORK 350 Fifth Ava. Tal (201) 566-9100
Hydrocarbon* & Polymars DIvliion-Uon OH
CL DORADO. ARKANSAS 71730 Lion Oil Building Tal. (601) Union 3-3111
JACKSON. MISSISSIPPI 39209 P. 0. Box 10937 Waatland Station Tai. (601) 362-3649
LITTLE ROCK. ARKANSAS 72203 1516 Waal Seventh Si. Tal. (501) Franklin 6-2437
MEMPHIS, TENNESSEE 38113 1023 Rivertide Owe P. 0. Bex 13248 Tal. (901) Whitehall 7-3151
Organic Chemicals Division (Rubber Industry)
AKRON. OHIO 44311 920 Btown Street P. 0. Box 2307 Tal. (216) Hemlock 4-1921
MONSANTO. tOO N. UNDBCROH BLVD.. ST. LOUIS. MISSOURI S3ISS
i
1
*Qt*S
1-7*75 -5/47
TECHNICAL BULLETIN PR O <T)
THERMINOL FR-0 FIRE-RESISTANT HEAT TRANSFER FLUID
Therminol FR-0 liquid phaM heat transfer fluid with low temperature pumpobility,
FLUIDS
Mktat --MtwM Mrtfa w*nk
h * 'xiiMMat m xata>
tWaMMiMMMIh hmwimh >ti Mt. TktiMwmmmmMmmM MM*ttww
tort MMNR MurMt; M M tuawWimi m miwilmi *> *ato MM taitiMw,
i4Mnmt*%inWwamnwt iIm*uirtnmlM*
ton* m watfM. iMinii wHk INmMMMm
mcmim
m
immmt
im
+mm
0r|* OlvUn/IM I. !Mk|h
ui* lU IJIM
049486 MOWS
Introducing Therminol FR-O...
Newest member of the growing line of Monsanto heat transfer fluids. Therminol FR-0 was formu lated specifically to eliminate freeze-up during cold weather shut down for in-transit heating of sulfur, pitch, asphalt, naphthalene, bunker "C" fuel oil, and high melting resin materials. Therminol FR-0 eliminates the need for high temperature reheat ing in order to pump out the material at its destination. Low temperature pumpability makes it ideally suited for space heating applications, outdoor plants in Northern climates, nr in nv
| peratures is a nrerenuisite.
hra-Resistance...
Therminol FR-0 permits installation of a nonpressurized system operating with a liquid that has no Are point, and will not support combustion ... so fire-resistant, Therminol fluids have achieved
recognition by Underwriters' Laboratory, Factory
Mutual, and Faotory Insurance Association, e
cause of this extreme fire-resistance and its listing
by insurance companies, important savings can be
made in designing a process heating system around
Therminol FR-0 fluid.
.
Chemically Speaking...
Therminol FR-0 fluid is a chlorinated biphenyl,
manufactured under exacting process control to rigid specifications for long term thermal stability,
" ` ' lli-ini;il
;<_ ,; ,'11 .
.aid viscnftit.v. 'I he liquid is an oilv. rl**r
......................I *1 T'" - 1
J'ti <llUJ C U .t .
Therminol FR-0 fluid is recommended for use up to 500*F and will not show measurable change after years of exposure to such temperatures. The fluid is non-corrosive with all common metals used in heat transfer system designs.
Praparty Klnimatle Viscosity, e*. Siybolt VlKOilty. SSU Viper Praisura, mm Hg SpKlfie Hut, BTU/lb.* Thwmil Conductivity,
Density, |/oe Density, lbs./gal. kMMMahnMmnnimcr
TYPICAL PROPERTIES OF THERMINOL FR-0
Temperature, *F
-1 +11 40
100 800 800 400 NO ON
4545 1007 92.55 8.10 1.70* 0.9S - - -
20850
4640 429
52.43
7.99* 4.54
-
-
-
- - - - 1.35 13.X 76.0 315 915 - - - 0.27 0.29 0.31 0.33 0.35 0.36
-
-
-
0.061
0.060
0.059
0.058
0.057
0.056
- 1.45 1.43 1.40 1.34 1.28 1.23 1.17 1.11
-
12.10
11.92
11.70
11.19
10.69
HX27
9.76 9.27
HONS 049*87
SPECIFIC HEAT
SPECIFIC HEAT. B TU /lb.
KINEMATIC VISCOSITIES
Tamparatura, *F
HONS 049489 2.2|6-Om- U*HO
THERMINOL* 66 HEAT TRANSFER FLUID
... for use in liquid phase between 0-660F without system pressurization
TECHNICAL BULLETIN (T-S6)
FLUIDS
"Ne*>| ceMSiAM M<ti* is te Be ertie*E el iscerem*#* te Ult siry ret AkI
tftM'MtoM W0NIAN10 MAK(t NO WAAAANIlit *110 1H( FITHIHOA HHBCIIANIStl
lltf or ANT raOOMtt HMAMO to. *i ** f
retell* frp t*i.t*u MH
UMBWM irdsrnMrM m issemreerMlieei. ir>4 AimIsmi iH hiBrirty ler l r*i*f.t **
Orfonio DMoioo/ IM N. Uit<W|k M./St Unit. MtoMori HIM
MUNS 049490
Introducing Therminol 66
Therminol 66 is a heat transfer fluid for use in liquid phase between 0-650T without system pressurization. The low pour point of this product permits start up at fluid temperatures as low n 0"K.
To minimize fluid oxidation, systems with Therminot 66 should be blanketed with an inert almas* pherc. A system relief valve should also be provided. Therminol 66 is ideally suited to replace organic fluids that have lower boiling points and must operate under system pressure at 650F.
Therminol 66 can support combustion and should not be confused with Monsanto's Therminol FR fire-resistant fluids.
TYPICAL PROPERTIES OF THERMINOL* 69
Composition Appearance Color Odor Pour Point
flash Point
flame Point
Autoignition Temp. Coefficient of Expansion Boiling Range
Modified terphenyls
Oily liquid Practically colorless
Faint, characteristic
-26 --28C.
16S - 180C. 334 - 356'F.
190 -- 202C. 374 - 392F.
3649C. 705 F.
0.000741 cc. cc, X.
340 - 396"C 644 - 745F
HONS 049491
VAPOR PRESSURE, m m Hg
SPECIFIC HEAT
SPECIFIC HEAT. BTU/HR. (*F)
KINEMATIC VISCOSITY. CENTISTOKES
KINEMATIC VISCOSITIES
a ii n h h h n n w 10a na in im im luiuiriiaaittias > i*> na m j TEMPERATURE. F
HONS
049493
} 1ITHO IN U S *.
. hJko v,=c ct.. * ' "
pftCK. AN"P cC"Hitctrr c&.vv.
rouNoco tea*
^ .. f >
v Sw>i &> forjJwftf /'T7, WNett) e*
JJaliurml (8ottr& of JTut Uni)mufilers
K. 8. OCICL'3. Vice P*Rioew? W. C. AUSTIN. Vice fnc*. a*.o OccuCTAur
F. RAVOEY. JR.. tflCAJUnCH
fa
' ' VkV
Pile MH7640 Assignment 6104452
September 5, 1961
REPORT
on
HEAT TRANSFER FLUIDS
Monsanto Chemical Co. St. Louis, Missouri
MONS 049494
File MK7640 .
Page 1
Issued: 9-5-61
DESCRIPTION
PRODUCT COVERED:
Heat transfer fluids, "Thermofluid FR1," "Thermofluid FR2," and "Thermofluid FR3."
GENERAL CHARACTER AND USE:
These produsts are mixtures of liquid chlorinated aromatic hydrocarbons in different proportions intended for use as heat transfer mediums in systems operating at atmospheric pressure.
MARKING:
Listee's name and trade name.
HONS 0*9*95
Pile MH7640
Page Cl
Issued: S-5-61
GENERAL
The products covered by this Report are mixtures of
liquid chlorinated aromatic hydrocarbons in different pro portions intended for use as liquid phase heat transfer mediums in systems operating .at atmospheric pressure. Products
of similar formulation have been previously investigated and listed by the Laboratories for use as dielectric and cooling mediums in electrical apparatus.
The object of this Investigation was to determine the fire and explosion hazards of the products.
(In planning the investigation, consideration v;as given to the general nature of the products, their fire and toxicity
hazards, corrosive action, stability, and practicability. The method of investigation of each of these features is given below.
. Information as to the general nature of the products was obtained from identification tests.
In the study of the fire and toxicity hazards, the
products were investigated as to flammability, explosiveness
of the vapors when mixed with air, ignition temperature,
behavior in the presence of hot metals, and decomposition
temperature. The products of decomposition were investigated
in respect to flammability and explosibility. Consideration
was also given to the toxicity of the gases produced on
contact of the products with hot metal surfaces and electric
arcs. The tests included flash point tests, fire point tests.
Ignition temperature tests, tests for explosiveness of vapors
in air, explosive range tests, test of behavior in the presence
of hot metals, decomposition temperature tests, and analytical
tests of decomposition products.
-
Corrosion' tests of the products on some common metals were eonduoted.
Information bearing on the stability of the products Was obtained from decomposition temperature tests, corrosion teet3, spontaneous heating tests, and consideration of the
Chemical properties of the products.
The practicability of the products was considered from the standpoint of their general nature and available data.
HONS
049496
File MK7S40 .
Pago Tl-1
Issued: 9-5-61
TEST RECORD NO. 1
SAMPLES:
Samples representative of the products "Thermofluid ysi," "Thermofluid FR2," and "Thermofluld FR3" were used in the tests.
IDENTIFICATION TESTS: .
. METHOD
Specific Gravity - The specific gravity of each product was determined by means of a pycnometer.
Tests for Chlorine - A few drops of each product, together with a small piece of metallic sodium, were heated in a test tube over a Bunsen burner. After the reaction was completed, the test tube was broken in water, the resulting
solution filtered, and nitric acid and silver nitrate solution were added. The formation of a white precipitate of silver
chloride indicates the presence of chemically combined chlorine in the product.
Distillation Test - A 100 g sample of each product
was distilled, using theHMethod (D20-30) of the American Society for Testing Materials.
RESULTS '
The results of the identification tests are recorded in Table I.
HONS 049497
F ile MH7640
Page T l- 2
Table X
Results of Identification Tests
"Thermofluid FR1" "Thermofluid FR2" "Thermofluid FR3"
Specific gravity at 15.6 C (60 F) 15.b C (60 Fjf
Chlorine
1.384 Present
1.456 Present
1.548 Present
Distillation test: Initial boiling point Per cent, by weight, distilled at indicated temperatures
End point Residue, per cent by weight Distillation los3, per
cent by weight
312 c (594 p) 88.7 per cent
below 335 C (635 P). 10.2 per cent at 355 C (635 F) 358 C (676 F).
358 C (676 F) 0.8 0.3
330 C (626 F)
352 C (666 F)
60.5 per cent beiovr 340 C (644 F). 27.5 per cent at 340 C (644 F) - to 350 C (662 F). 9.5 per cent at 350 C (662 F) to
379 C (635 P).
72.1 per cent at
270 C (518 F) to 366 C (690 F). 24.0 per cent
above 366 C (690 F)
379 C (714 F)
374 C (706 F)
1.3 3-5 1.2 0.4
Issued: 9-5-61
HONS 049498
File MHTS40
Page Tl-3
Issued: 9-5-51
FLASH POINT TESTS:
METHOD
The flash point of each product was determined with the Pensky-Martens closed tester, using the Method (D93-^6) of the American Society for Testing Materials.
RESULTS
The results of the flash point tests v;ere as follows:
Product
Flash Point (1)
"Thermofluid FR1" "Thermofluid FR2"
"Thermofluid FR3"
176.7 C (350 F)
196.1 C (385 F) 232.2 0 (450 ?)
FIRE POINT TESTS:
METHOD
The fire point tests were made with the Cleveland open
cup tester, using the Method (D92-46) of the American Society
for Testing Materials.
.
RESULTS
The products "Thermofluid FR1," "Thermofluid FR2,"
end "Thermofluid FR3" gave negative results in the fire point tests.(2) Intermittent flashes were obtained, but the products
did not continue to burn. The samples ware heated to the boiling point, and the test then discontinued.
(1) The flash point alone is not necessarily a true
measure of the fire hazard of a liquid. In
.
this connection, see note (2). .
(2) In view of the negative results obtained in the fire point tests, it is clear that the flash point tests cannot be depended upon to give a
true measure of the fire hazard of these products. It was therefore necessary to conduct tests for explosiveness of vapors in air.
MONS 049H99
File MH7640
Page Tl-4
Issued:. 9-5-61
IQNITION TEMPERATURE TESTS:
METHOD
The apparatus consisted essentially of a combustion
ohambor surrounded by a molten solder bath, which was heated at a constant temperature during the test. The temperature of the solder bath was measured by means of calibrated thermocouple provided with a quarts tube to protect the hot Junction.
The combustion chamber consisted of a quartz flash
of conical form with flat bottom, 11.4 cm in height, 6.0 cm in diameter at bottom, and 2.8 cm in diameter at top. It
was of about 160 ml capacity (rated capacity 125 mi) having a ratio, of surface area to volume of about 1:1.
Measured test samples of the products in the liquid phase were introduced into the heated combustion chamber by means of a micropipette. Different amounts of the product were admitted to the chamber in successive tests at progres sively lower temperatures in order to determine the minimum
temperature at which the vapor, in any proportion with air, will ignite without application of a flame. The residual vapors or gases in the combustion chamber were displaced by a stream of air in the interval between tests.
RESULTS
The results of the ignition temperature tests were as follows:
Product
Ignition Temperature (3)
"Thermofluid FR1" "Thermofluid FR2" "Thermofluid PR3"
652 C (1206 F)
672 0 (1243 ?) 571 C (1060 F)
(See note (3) on following page.)
HUNS 049500
File im&iO
Page II-5
Issued: 9-5-61
(3) The main value of the ignition temperature test . is to determine the minimum temperature required
to produce ignition under the most favorable conditions in the absence of a flame or spark* including ratio of vapor to air and ratio of heated surfaceto volume of vapor-air mixture. Under less favorable conditions* as when the liquid is applied to a hot place, a higher temperature for ignition is required. A limitation of the ignition test in a small vessel is that it does not show whether flame propagation for any material distance will occur. After determining the ignition iem perature, therefore, it is necessary to obtain additional data having a bearing on flame propagation. These data are given by tests , for explosiveness of vapors in air.
TESTS FOR EXPLOSIVENESS OF VAPORS IN AIR:
METHOD
' The apparatus consisted of a horizontal cylindrical steel vessel, 6 in. in diameter (interna^ and 26 in. long. It was provided with a small mica window and an outlet to the atmosphere, this outlet being normally closed by a loosely fitted asbestos plug. Openings were provided half way between the ends of the vessel to admit electrode terminals connected to an induction coil. The electrode terminals were centrally located in the vessel, and were spaced to give a spark gap of 1/4 in.
The vessel was heated externally by gas burners. An Iron constantan thermocouple connected to a potentiometer was used for rough measurements of the temperature of the vapor inside of the vessel.
Samples of the liquid products, ranging in volume from 20 to 80 ml, were introduced into the vessel which had previously been heated to a predetermined temperature. Sparks were passed between the electrode terminals at intervals of 1/2 rain, and observations made as to whether ignition of the test mixture and flame propagation occurred.
HONS 049501
File MH7640-
Page Tl-6
issued: 9-5-3
Residual gases and vapors were displaced from the cylinder by a stream of air in the interval between tests.
results
"Therm.ofluld FR1" - No propagation of flame occurred in mixtures of tne vapors of the product with air at temper atures up to l4l C (26S F). Flame propagation with weak" pressure effects (sufficient to push asbestos plug from the outlet of cylinder) occurred at 144 C (291 F). Moderate pressure effects (asbestos plug thrown about 3 or 4 ft horizontally from outlet of cylinder) were obtained at temperatures somewhat above 144 C (291 F).
"Thermofluid FR2" - Ko propagation of flame occurred in mixtures of the vapors of the product with air at temper atures up to 148 C (298 F). Flame propagation with weal:' pressure effects (sufficient to push asbestos plug from the outlet of cylinder) ooourred at 150 0 (302 F). Moderate pressure effects (asbestos plug thrown about 3 or 4 ft horizontally from outlet of cylinder) were obtained at temperatures somewhat above 150 C (302 F).
"Therm.of3.uid FR3" - No propagation of flame occurred in mixtures of the vapors of the product with air at temper atures up to 204 C (399 F). Flame propagation with weak pressure effects (sufficient to push asbestos plug from the outlet of cylinder) occurred at 208 C (4oS F). Moderate pressure effects (asbestos plug thrown about 3 r 4 ft horizontally'from outlet of cylinder) were obtained at temperatures somewhat above 208 C (406 F).
MONS 049502
Pile mjSkO
Page 11-7
Issued; 9-5-61
EXPLOSIVE RANGE TBS1S:
METHOD
The apparatus consisted essentially of an explosion chamber of glass equipped with a spark gap and a stirrer. The chamber was cylindrical with the lower end hemispherical. It was approximately 3 in. in diameter, 8 in. in height, and had a net volume of 52.6 cu. in. (8S3 cc). The chamber was provided with a glass lid supporting the stirrer and the leads to the sparlc gap near the bottom of the chamber. An opening In the lid was provided for introduction of the sample. The glass chamber was immersed in a molten solder bath to a depth of 6 in.
1 In conducting tests, the solder bath was maintained at a constant temperature of 400 C (752 F), a measured quantity of the liquid product to he tested was placed in the chamber, and the contents of the chamber stirred to produce a uniform vapor-air mixture. The electrical discharge from an induction coil was then passed at the spark gap while observations were made for flame travel (upward propagation) and pressure effects. Following each test the residual gases and vapors were displaced from the chamber by a slow stream of air in preparation for the next test.
RESULTS
The results of the explosive range tests of "Thermofluid FR1," "Thermofluid FR2," and "Thermofluid FR3" in air at 400 C (752 F) are shown in Table II.
HONS 049503
F ile MH7640
Table II
Results Of Explosive Range Testa
--
Lower Limit
Upper Limit
___
----------------------- ---- -------------- per Cent' " '
FeFUent
Lb Valorized Vapor By
Lb vaporized Vapor By
Liquid Per Volume In
Liquid Per Volume In
-
Volume Of 1000 Cu Ft Mixture
Volume Of 1000 Cu Ft Mixture
Liquid Used Of Air
With Air Liquid Used Of Air
With Air
Product In Test, Ml (Calculated) (Calculated) In Test, Ml (Calculated) (Calculated)
"Thermofluid FR1"
"Thermofluid FR2" "Thermofluid FR3"
0.038
0.033 0.038
' 3.9
3.5 3-7
1-3 0.110
1.1 0.119 1.0 0.100
11.4
13.0 9.7
3-9
3-9 27
Weak pressure effects were obtained In these tests as would be expected for mixtures near the limits of flammability.
Page T l-8
Issued: 9-5-61
o z in
o sD o
File KH7640
Page Tl-9
Issued: 9-5-61
TESTS 0? BEHAVIOR IN THE PRESENCE OF HOT METALS:
METHOD
Tile apparatus consisted essentially of a horizontal
steel plate, 10 in. square and 1/4 in. in thickness, heated by Gas burners underneath. Flames and hot gases from these burners were deflected from the upper surface of the steel plate by a thin sheet of steel extending 10.in. horizontally
beyond the edges of the plate. This deflector was bo?.ted to the edges of the plate, asbestos gaskets being provided at
the joints. A calibrated chromel-alumel thermocouple (No. 14 Av:g), connected with an indicating potentiometer, was used to measure the temperature of the plate, the hot junction
of the thermocouple being brazed to the center of the upper
surface of the plate. Check measurements of the temperature of the plate were also made using an optical pyrometer of the disappearing filament type.
In conducting tests, measured samples (up to 10 ml)
of the product "Thermofluid FR3" were dropped onto the center of the upper surface of the heated plate. A slow stream of air was applied to the evaporating sample in some of the tests. The minimum ignition temperature was determined by successive trials, during which the steel plate was maintained at pro gressively lower temperatures.
RESULTS
The product "Thermofluid FR3" when applied to the steel plate heated at 754 C (1390 F), or higher. Ignited. The combustion wa3 very weak ar.d did not show any tendency to propagate beyopd the vicinity of the heated surface. It will be noted that there was no confinement of the vapors in these tests with the heated steel plate.
HONS 049505
File MH7S40
Page Tl-lO
Issued: 9-5-61
DECOMPOSITION TEMPERATURE TESTS:
METHOD
The apparatus previously described in connection with ignition temperature tests was used in these tests.
The vapors evolved on introducing samples of the products into the heated chamber were tested with moist blue litmus
paper, a change in the color of the paper from blue to red Indicating decomposition of the product. The minimum tem
perature at which litmus paper showed an appreciable change in color within a short time (3 min) was considered to be the decomposition temperature.
RESULTS
The results of the decomposition temperature tests are recorded below:
Product
Decomposition Temperature
"Thermofluid FR1" ' "Thermofluid FR2" "Thermofluid FR3"
309 C (588 F)
305 0 (581 F) 300 C (572 F)
ANALYTICAL TESTS OF DECOMPOSITION PRODUCTS:
METHOD
Hot Iron Surfaces - The cylindrical vessel previously described under tests for explosiveness of vapor in air was also used for exposing vapor-air mixture to hot iron surfaces. Connections for withdrawing samples of the decomposition products for analysis were inserted in the outlet pipe. The cylinder was externally heated to a temperature of 600 C (1112 F) by gas burners.
The heat transfer fluids, in the liquid phase, were introduced into the heated cylinder at a uniform rate. Samples of the decomposition products vrere withdrawn from the outlet pipe and hydrochloric acid, free chlorine, phosgene, carbon dioxide, oxygen, carbon monoxide, gases absorbed by fuming sulphuric acid or bromine, methane and other paraffin hydrocarbon gases, and in some eases hydrogen, were deter mined using the following methods.
HONS 049506
me MH7S'tO
Page Tl-l1
Issued: 9-5-61
Hydrochloric acid was determined toy absorption in water end subsequent titration with standard alkali solution. Samples wore collected in evacuated glass sampling tubes, or a measured sample was dra'wn by means of a calibrated aspirator bottle through an absorption train consisting of three spiral form bubbling toveers. Free chlorine interferes with the determination and is removed by mercury in contact with the absorbing water.
Tests for free chlorine were made by liberation of iodine from aqueous potassium iodide solution and subsequent titration with sodium thiosulphate solution, using starch solution as an indicator. A measured sample was drawn by a calibrated aspirator bottle through an absorption train conSlsting of two spiral form bubbling towers containing potassium iodide solution.
Phosgene was determined by absorption in aqueous aniline solution. Phosgene reacts quantitatively with aniline to form diphenylurea, one molecule ox' phosgene being equivalent to one molecule of diphenylurea. A measured" sample was drawn through a train of three bubbling towers containing freshly prepared aqueous aniline solution saturated with diphenylurea. Free chlorine interferes with the determination end was removed by granulated antimony con tained in a tube through which the sample passed before entering the bubbling towers. The precipitate of diphenylurea was separated from the aniline solution by filtration, washed with cold water, dissolved in ethyl alcohol, recrystallized, dried, and weighed.
Carbon dioxide, oxygen, gases absorbed by bromine or fuming sulphuric acid, and methane and other paraffin hydro carbon gases, were determined using either the Morehead form of gas analysis apparatus or an Orsat form of gas analysis apparatus of the precision type. In some tests, hydrogen was also determined, using the Orsat apparatus'. Samples of the decomposition products for these determinations were collected in evacuated glass sampling tubes. The samples were treated with silver nitrate solution to remove hydro chloric acid, before proceeding with the gas analyses.
HONS 049507
Pile KH7640
Page Tl-12
Issued: 9-5-61
Electric Arcs - These tests viere conducted with the product '"Thermo fluid PR3."
The apparatus consisted of a cylindrical steel vessel 10 in. in diameter (internal) and 18 in. in height. It was provided with a small mica window and an outlet to the atmo sphere. Openings were provided in the vessel to admit two electrode holders, one holder being fixed and the other movable. The electrodes v/ere copper rods 1/2 in. in diameter, their arcing terminals being horizontal. A connection for withdrawing samples of decomposition products for analyses was inserted in the wall of the vessel, above liquid level. A small cylindrical settling chamber for the removal of solid products of decomposition was attached to the sampling connection.
The electrodes were connected to a 230 v, d-c test circuit, the current being controlled by resistors. An ammeter was connected in the circuit, and a voltmeter was conneoted across the electrode terminals.
A sample of the product, about 15 lb, vras placed in the vessel, the arcing terminals of the electrodes being partially immersed in the sample. The arcing terminals were located on the axis of the cylinder, 3-1/2 in. above the bottom. A continuous arc (170 amp) was maintained between the electrodes until destruction of the arcing terminals (5 min).
Samples of the decomposition products were withdrawn continuously from the test vessel while the arc was in oper ation, and tested for phosgene and chlorine, using the methods previously described. Samples of the decomposition products were also collected in evacuated glass sampling tubes at the conclusion of the test, and the chief constituents determined, using the following methods.
HONS 049508
File MK7640
Page Tl-13
Issued: 9-5-61
Hydrochloric acid was determined by absorption in water
and subsequent titration with standard alkali solution. Carbon dioxide, carbon monoxide, oxygen, gases absorbed by bromine, and paraffin hydrocarbon gases were determined using the i-torehead apparatus. The samples were treated to remove hydrochloric acid before conducting the gas analyses.
Tests were also conducted with the arcing terminals of
the electrodes immersed 2-3/^- in. below the level of the sample
in the vessel. A 21 lb sample of the product was used in these
tests. The arcing terminals vrere located on the axis of the
cylinder, 2 in. from the bottom. A continuous arc (125 to
190 amp) was maintained between the electrodes until destruction
of the arcing terminals. Samples of the decomposition products
were withdrawn at intervals during the tests (see Table V),
and the chief constituents determined using the methods pre
viously described.
,
RESULTS
Hot Iron Surfaces - The results of analytical tests of the decomposition products of the heat transfer fluids "Thermofluid FR1," "Thermofluid FR2," and "Thermofluid FR3" in the presence of hot iron surfaces are shown in Table III.
Electric Arcs - The results of analytical tests of the decomposition products of the heat transfer fluid "Thermofluid FR3" in the presence of an electric arc between
terminals partially immersed in the fluid are shown in Table IV.
The results of analytical tests of the decomposition
products of the heat transfer fluid "Thermofluid FR3" in the presence of an electric arc between terminals totally immersed in the fluid are shown in Table V.
HONS 049509
Table III
Results Of Analytical Tests Of Decomposition Products In Presence Of' Hot Iron Surfaces
Concentration, Per Cent'By Volume (1)
"Thermofluid FR1" 5 Min (2l 13 Min
"Thermofluid FR2"
5 Min
13 Min
"Thermofluid FR3"
5 flin
13 Min
Carbon dioxide (CO2)
20.&
24.1
16.9
10.5
27.6
20.2
Carbon monoxide (CO)
Oxygen (O2)
Gases absorbed by fuming sulphuric acid or bromine
8.7 6.2 0.5
11-8 0.6 0.7
12.2 2.7 0.5
13.0 4.4
0.4
13.2 1.0 0.0
8.0 1.0 0.0
Paraffin hydrocarbon gases 2.5
1-6
1.4 . 1.4
0.0
0.0
calculated as methane
Hydrogen (H2)
0.8 3.8 0.7 3-5 -
-
5 to 13 Min
Hydrochloric acid (HC^)
25.3
34.8
22.3
44.8
11.2
5 to 13 Min
5 to 13 Min
Chlorine'(CI2)
0.000
0.000
0.000
Phosgene (C0C12)
0.000
0.000
0.000
(1) In addition to the volatile decomposition products some finely divided carbon
. wa3 formed. (2) Time of sampling, after start of test.
HONS 049510
V H
O
G\
O
C0r) KJ H1 E
H
W
OQWC* vo Vo1J\l
H
UH7640
Page T l-1 5
Results Of Analytical Tests Of Decomposition Products In Presence Of Klectric Arcs Between Terminals
Partially Immersed In Heat Transfer Fluid
Concentration, Per Cent By Volume (l)
"Thermofluid FR3" 5 Min C2l
Carbon dioxide (CO2)
1.3
Carbon monoxide (CO)
7-7
Oxygen (02)
7-7
Gases absorbed by bromine
Paraffin hydrocarbon gases calculated as methane
0.0 0.0-
Hydrochloric acid (HCi)
26.7 Start Of Test To 5 Min
Chlorine (CI2)
0.000
Phosgene (COClg)
0.000
(1) In addition to the volatile decomposition products a large amount of finely divided carton was formed.
(2) Time of sampling, after start of test.
Issued: 9-5-61
HONS 049511
P ile MK7640
Page T l-1 6
Table V
Results Of Analytical Tests Of Decomposition Products In Presence 0? Electric Arcs Between Terminals - -- Totally aiw3r,saiS"ln Heat Transfer Fluid
Concentration, Per Cent By Volume (1)
____________ "Thermofluid ^3"
2-1/2 Min (2)
5 Min
5-1/2 Min
Carbon dioxide (CO2) Carbon monoxide (CO)
Oxygen (02)
Gases absorbed by bromine Paraffin hydrocarbon gases
calculated as methane Hydrochloric acid (HCi)
0.0 0.8 12.4 0.0 0.0
0.0 0.5 7.4 0.0 0.0
0.0 0.4 5-7 0.0 0.0
36.5
62.0
69.2
Start Of Test To 5-1/2 Min
Chlorine (CI2)
0.000
Phosgene (COClg)
Less than 0.000
(1) In addition to the volatile decomposition products a large amount of finely divided carbon was formed.
(2) Time of sampling, after start of test.
issued: 9-5-61
nqns 049512
File MH7540
Page Tl-17
Issued: 9-5-51
SPONTANEOUS HEATING TESTS;
METHOD
The apparatus used for the spontaneous heating tests
consisted essentially of a vertical.- cylindrical test chamber,
7 in. in height and 4 in. in diameter, surrounded at the side
and bottom by a water bath heated by an electric hot plate.
The test chamber vras provided tilth a cover having two air
vent tubes ar.d an opening for introduction of a thermocouple
or a maximum registering thermometer. The sample was con
tained within the test chamber by a cylinder of wire gauze,
6 in. in height and 1-1/2 in. in diameter. This cylinder
was concentric with the axis of the test chamber, there being
an annular space through air of 1-1/4 in. between the cylinder
and the wall of the chamber.
In conducting the tests, 3.4 g of the product were
evenly distributed over 7 g of cotton fiber (commercial
absorbent cotton) and placed in the containing cylinder within
the test chamber. A maximum registering thermometer was
Inserted in the cotton bearing the test sample so as to measure
the temperature at the approximate center of the mass. The
cover was then placed on the test chamber and the water bath
surrounding the chamber maintained at boiling for a period
of 24 hr. A rise in the temperature of the sample above the
temperature of the ambient water bath under the conditions of
the test is an indication of spontaneous heating of the material.
RESULTS
'
The products "Thermofluid FR1," "Thermofluid FR2," and "Thermofluid PR3" showed no indications of spontaneous heating.
MOWS 049513
File KK7640
Paso Tl-18
Issued: 9-5-61
CORROSION TESTS:
METHOD
The metals used in the corrosion tests were copper, yellow brass, iron, tin-lead solder, copper ar.d lead-tin solder, and copper and iron coupled. Test specimens, 3/4 in. vrld and 6 in. long, were cut iron sheets of the metals. The specimens were buffed, measured, cleansed with soap and water, washed with ethyl alcohol and ethyl ether, dried, and
weighed.
Each metal specimen was immersed separately for half
Its length in a sample of the product contained in a glass tube provided with a cork stepper. The tubes and contents were maintained at a temperature of SO C (19^ F) in a thermostatically controlled electrically heated oven.
The metal specimens were examined visually at weekly intervals during the test for evidences of corrosion. At the conclusion of the test, the metal specimens were cleansed, dried, again weighed, and the change in weight per square
oentimeter of surface area calculated.
RESULTS
When heated in glass tubes containing the product
"Thermofluid ER2" at 90 C (19^ F) for 1465 hr, the specimens of metals showed little visible evidence of corrosion, except for a slight discoloration of the surfaces above the liquid. The change in weight of the specimens was very small (less than 1.0 mg/sq cm).
When heated in glass tubes containing the product
"Thermofluid FR3" at 90 C (194 P) for 1680 hr, specimens of
copper, yellow brass, copper and tin-lead solder, end cooper
coupled with iron showed no visible evidence of corrosion,
except for a slight discoloration on the surfaces above the
liquid. Specimens of iron, iron coupled with copper, and
tin-lead solder showed no change in appearance. The change
in weight of the.specimens was very small (less than
1.0 mg/sq cm).
RED Fit
MOWS 049514
File I'&j6!i0
Page Cl
Issued: 9-5-61
CONCLUSIONS
GENERAL NATURE:
These products are essentially mixtures of aromatic
hydrocarbons, the nature of which is considered'.a trade secret and is on file at Underwriters1 Laboratories, Inc.
The results of identification tests Indicate the products to be of the compositions stated by the manufacturer.
FIRS AND TOXICITY HAZARDS:
(These products are nonflammable at ordinary temper atures. They are capable of forming moderately combustible and explosive mixtures with air wider laboratory test con ditions at higher temperatures, beginning at a temperature level of 144 C (291 F) in the case of "Thermofluid FBI," 150 C (302 F) in the case of "Thermofluid FR2," and 208 C (5o6 F) in the case of "Thermofluid FP.3" but under practical conditions formation of combustible or explosive mixtures is
regarded as extremely unlikely. The fire hazard is very
email.
* With respect to fire hazards, the products are classed 2 to 3 in accordance vr.ith Underwriters' Laboratories, Inc.'s Standard for the Classification of Liquids in which:
Ether rates Gasoline rates Alcohol (ethyl) rates
Kerosene (ICO F flash closed cup) rates
Paraffin oil rates
100 $0-100 60-70
3~^0 10-20
It will be noted that the flash points of these products ere comparatively high, and that a so-called "fire point" was not obtained. Although intermittent flashes occurred in the fire point tests in the open cup, the products did not con tinue to burn. The flash point and the so-called "fire point" tests, particularly the latter, in the case of chlorinated aromatic hydrocarbons, are of limited value as a measure of
fire hazard, but are useful for the purposes of identification. The practical significance of the above tests in uil`3 cs.se Oi* these products is that their fire hazard is of a low order.
MGNS 049515
File MH7640
Page C2
Issued: 9-5-61
As shown by the results of tests for explosiveness of vapors in air, vapors of "Thermofiuid FR1" failed to Ignite or explode in tests at initial temperatures of l4l c (286 ?), but propagated flame with weak pressure effects in tests at 144 C ('291 F). Vapors of "Thereofluid FE2" failed to ignite or explode in tests at initial temperature of 148 C (298 F),
but propagated flame with weak pressure effects in tests at
150 C (302 F). Vapors of "Thermofiuid FR3" failed to ignite or explode in tests at initial temperature of 204 C (399 F), but propagated flame with weak pressure effects in tests at
208 C (4o5 F). Moderate pressure effects were obtained in tests with mixtures at somewhat higher initial temperatures. At a temperature of 4-00 C (752 F), the lower and upper limits
of flammability (upward propagation) of the vapors'of the products were found to be as follows:
Produot
Per Cent Vapor Of Product, By
Volume, In Mixture With Air
Lower
Upper
Flammable
ammahl.o Flammable
Limit
. Limit
Range
"Thermofiuid FR1" "Thermofiuid FE2"' "Thermofiuid FR3"
1.3 3.9 2.6
1.1
3-9
2.8
1.0 2.7 1.7
It will be noted that these are relatively narrow flammable ranges.
The minimum ignition temperatures of the products
under laboratory conditions were found to be 652 C (l205 F),
672 C (1243 F), and 571 C (1060 F) for "Thermofluid FR1," "Thermofluid FR2," and "Thermofluid FR3," respectively, as recorded in the results of ignition temperature tests.
The produot "Thermofiuid FR3" when applied to a hot iron surface did not ignite at plate temperatures below
75^'C (1390 F). At higher temperatures the combustion was
very weak and did not propagate beyond the vicinity of the heated iron surface.
MUNS 049516
File Fu-17640
Page C3
Issued: 9-5-51
Tiie gases produced by burning, or decomposition of the products by heat, are nonflammable or nonexplosive, as evolved or minced with air. The gases formed by burning or thermal decoamoosition were similar, whether formed by hot surfaces or electric arcs.
The gases or fumes produced by decomposition of the products include hydrochloric acid, carbon monoxide and in some cases trace amounts of phosgene. This will ordinarily constitute a. toxic ha.sa.rd only where the conditions are such as to cause confinement of the fumes, as in a closed room in which combustion or decomposition of the products is main tained by fire, highly heated surfaces, or electric arcs.
The exceedingly unpleasant and irritating fumes from the decomposition of these products, even in concentrations of a very lovr order, act r.ot only to give warning of their presence but to prevent dangerous exposure of persons. While carbon monoxide is odorless and toxic, its formation from these products is always accompanied by the simultaneous formation of hydrochloric acid gas, -which gives adequate warning of its presence as brought out above.
It will be noted that combustion and decomposition of the products were maintained by heated surfaces (600 C, 111? F) or by an electric arc in carrying out the analytical tests of the decomposition products. As shown by the results of the decomposition temperature tests, the products were not appreciably decomposed at temperature below 300 C (572 F).
CORROSIVE ACTION:
No corrosion occurred in the tests conducted with representative metals and alloys in the presence of the products, as recorded under corrosion tests.
It will be noted from the results of analytical tests of decomposition of products that appreciable amounts of hydrochloric acid, a corrosive agent, are formed on combustion or decomposition of the products in the presence of hot metal surfaces or electric arcs.
HONS 049517
Pile mj6ko
Page C4
Issued: 9-5-61
STABILITY:
The products are reasonably stable, and in use are unlikely to undergo decomposition resulting In an increase in fire hazard.
In the decomposition temperature tests the products did not undergo appreciable decomposition at temperatures below 300 C (572 P). Considerations of the chemical com position and properties of the products also indicate that they are reasonably stable.
In the spontaneous heating tests, the products showed no tendency to heat or ignite spontaneously under test con ditions designed to start and accelerate the process.
PRACTICABILITY:
It is considered practicable to use these products as.
heat transfer fluids in systems operating at atmospheric
pressure.
'
The products are not Intended to replace other heat transfer fluids unless the equipment is designed for such . heat transfer fluids or these products. Due to the fact that some gasket, seal, packing, and hose materials may not be suitable for use with these produots, the equipment manufacturer should be contacted with respect to his recom mendations in connection with the replacement of such materials.
CONFORMITY:
These products have been classified as to their fire hazard in accordance with the Laboratories' Standard of Classification.
FOLLOW-UP PROGRAM:
These heat transfer fluids will be placed under the Reexamination Service of Underwriters' Laboratories, Inc.
MONS 049518
File KH7S40
Page C5
Issued: 9-5-61
RECOMMENDATION
TO THE'FIRE COUNCIL OF UNDERWRITERS1 LABORATORIES,, INC.
Wo recommend promulgation of 'chc following notice to subscribers and the action indicated thereby.
Guide No. 5^0 1.8, Heat Transfer Fluids.
September 5, 1961
MH7640.
Monsanto Chemical Co., St. Louis 66, Mo.
"Thermofluid FR1," "Thermofluid FR2," "Thermofluid FR3."
Mixtures of chlorinated aromatic hydrocarbon liquids intended for use as heat transfer fluids in systems operating at atmospheric pressure.
The fire hazard of these products is small, being consider
ably less than that of paraffin oil. Upon heating the liouid to temperatures of the order of
144 C (291 F) in the case of "Thermofluid FR1," 150 C (302 F) in the case of "Thermofluid FR2," and 2c8 C (406 F) in the
case of "Thermofluid FR3," it may burn weakly upon ignition.
Form moderately combustible and explosive; mixtures with air at somewhat higher temperatures, xgnltion temperature 652 C (1206 F) for "Thermofluid FR1," 672 C (1243 F) for
"Thermofluid FR2," and 571C (ICGO F) for "Thermofluid FR3." Not subject to spontaneous heating.
Classed 2 to 3 in respect to fire hazard.
800 N. Lindbergh Blvd.
Reexamination Service - See General Information Card of above guide number.
HONS 049519
File MH7640
Page C6
Issued: 9-5-61
Report by:
-R. E. DUFOUK Senior Assoc. Managing Engr Chemical Department
REVIEWED BY AND SUBMITTED:
r**> U"''-C- * ( / :'7
t
E. N. DAVIS Managing Engineer Chemical Department
The foregoing Recommendation has been accepted MOV 9 jcgj
UNDERWRITERS' LABORATORIES, INC.
REDsDCO
(SI2ME0) XL S. AUSTiCi
Vice President and Secretary
MONS 0495i0
--Ihor
L
FR
FLUID HEAT
SYSTEMS
ENGINEERING HEAT TRANSFER DATA
A Design Guide For Engineering Low-Cost, Low-Pressure FIRE-RESISTANT HEAT TRANSFER SYSTEMS
HONS 049521
TABLB OP CONTINTS
Introduction........................................................................................ Properties Important To Heat Transfer Design................................ Curves: Viscosity/Temperature; Density, Specific Gravity............. Curves: Specific Heat; Thermal Conductivity.................................. Specific Heat of Therminol Fluids: Relationship To Density........... The Heater........................................................................................... Therminol System Components.........................................................
Pumps, Piping, Valves, Rotary Joints, the Expansion Tank, etc. Testing, Cleaning, Filtering................................................................ Controls for the Therminol System................................................... Operation and Maintenance of the Therminol System..................... Typical Therminol Systems................................................................ Therminol Engineering Data............................................................... Resistance of Valves and Fittings To Flow of Fluids........................ Pressure Drop; Heat Transfer Rate, Heat Exchangers...................... Viscosity Conversion Chart................................................................ Engineering Conversion Factors........................................................ Typical Applications for Therminol Systems.................................... Safety of Handling Therminol Fluids................................................. Notes....................................................................... .............................
1 3 4 8
a
11
14 15 ia 18 aa
as
30 38
30 48 40 47
MONS 0495i2
^hermJUriaJL PR FLUID HEAT SYSTEMS...
Delivering High-Temperature Process Heat as a Liquid
Aa recently as 1941, process engineers were limited to two methods of delivering process heat: DIRECT FIRING or PRESSURIZED VAPOR. Each method had definite draw backs. Direct firing was often unsatisfactory because the heating was uneven, the tempera tures difficult to control, and the processing of combustible materials extremely hazardous. Prossured-vapor, such as steam, required costly, high pressure piping, valves, and proc essing equipment--plus constant chemical "conditioning" of boiler water. Heat energy and temperature loss were common with pressured-vapor systems because of "blowdowns," condensation, and the inevitable pressure loss with long runs of piping.
Today, non-pressurized, high-temperature, fire-resistant heat transfer systems based on Monsanto's THERMINOL FR Heat Trans fer liquids overcome practically all the de
ficiencies and drawbacks of direct firing and
pressurized-vapor heating. THERMINOL
FR--a series of high-boiling, heat-stable
organic liquids, delivers processing heat to
single or multi-users as a liquid without pres
surizing. THERMINOL fluids are safe and
fire resistant. Heating is uniform; and tem
perature control accurate within a range of
plus-or-minus 2F.
,
Heat transfer systems now in use for several years have proved THERMINOL fluid heat successful in a wide variety of process heating operations ... from food cooking to chemical processing, from distillations to drying ovens and in petroleum refining.
Design engineers and manufacturers have developed a variety of THERMINOL FR Fluid Systems ranging from small electrically heated units to giant gas or oil fired units-- all capable of delivering heat AS A LIQUID.
HONS 0*9523
1
This manual explains and illustrates the fundamentals of THERMINOL fluid heat transfer systems design. It lists materials of construction and components for use with THERMINOL, and explains how each is "designed in" to make the most efficient system for safe, economical and reliable opera tion. It shows how these systems can be
adapted to a wide variety of heating and cooling processes. This engineering heat trans fer data has been compiled to aid the Process Engineer in designing a safe, minimum main tenance system for delivering heat to the points of use in practically any commercial or industrial process.
t\
t 1
\
1
\
a:
fhermJUrioiLFR HEAT TRANSFER LIQUIDS...
Monsanto THERMINOL FR heat transfer liquids are chlorinated biphenyls, manufac tured under exacting process control to pro duce fluids consistent in all properties impor tant to heat transfer. THERMINOL FR products are unique in that they are actually produced to rigid specifications for thermal stability, specific heat, thermal conductivity, vapor pressure, and viscosity.
There are three THERMINOL FR products, with a range of low temperature fluidity and boiling points that allows the user to select the best balance of fluid properties for a specific use:
THBRMINOL FR 1 with lowest temperature fluidity -- excellent for processes requiring both heating and cooling
THBRMINOL FR 8 with optimum balance of properties for use in most common industrial heating applications
THBRMINOL FR 3 with highest boiling point for special proc essing equipment applications
MONS 049524
2
PROPERTIES IMPORTANT TO HEAT TRANSFER DBSION
THIRMINOL PR-t
Temperature
c.
SO 10.0 100 97.6 ISO 68 0 03 080 121 900 140 980 177 400 204 480 898 800 200 BB0 288 800 316
880 843 700 371
Bnthatpy PTU/Lb.
4.696 18.66 32.88 46.07 83.80 70.46 09.04 112.86 130.48 148.82 167.08 186.16 208.78 228.82
8plfle Heat Thermal Conduct. TU/Lb.--*F. TU/Ft!, Hr., F./Ft.
0.272 0.282 0.281 0.3047
0.9161 0.3288 0.3380 0.9404
0.8808 0.8072 0.8770 0.3880 0.3888 0.4080
0.06008 0.08080 0.08021
0.09878 0.08027 0.08878 0.08818
0.06760 0.06687
0.06880 0.08800 0.06487 0.08408 0.08328
Dancity Lb./Oat.
11.683 11.488 11.216 10.001 10.760 10.680 10.206
10.088 0.83S 8.801 0.370 0.188 8.006 6.678
Vlceealty tb./Hr.-Ft.
749.36 86.144 15.672 8.2431 9.8270
2.4763 1.8808 1.6028 1.2381 1.0428 0.60031 0.70180 0.70731
H|. Abootute
27 08 149 221 950 18.8 pal* 31.8 pala
Temperature
F. c.
80 10.0 100 87.8 180 86 800 83 880 181 BOO 148 80 177 400 204 480 232 600 280 880 288 800 916 080 949 700 371
TH RMINOL PR .a
Inthalpy IpnlBe Haat Thermal Conduct TU/Lto. TU/Lb.--*F, TU/Ft?, Hr., *F./Ft
4.66 17.61 31.02 48.11 68.48 74.14 68.26 104.61 120.74 187.08
158.86 170.02
102.80 208.48
0.267 0.286 0.274 0.2640
0.2822
0.3008 0.8084 0.8188 0.6247 04321
0.8410 04481 0.8878
0.8884
0.08881 0.00882 0.06801 0.06780 0.08748 0.08703
0.08888
aoeooo
0.08148 0.05488
0.08424 0.08857
0.06288 0.06211
Denetty Lb./Cat
18.B6 12.000 11.780 11.825 11.298 11.068 10.830 10481 10.807 10.188 8.008 6.872 6.440 0.208
Vlaeaelty Lb./Hr--Fi.
7010.6 181.01 27.83 11.671
6.646 4.831 3.201 2.300 1.881 1.828 14766 1.0871 0.6808 04585
Hp. Abaelwte
6 18 87 4 178 940 616 264 pia
Tarnpimature
F. c.
80 10.0 100 37.6 160 66 200 03 260 121 300 149 380 177 400 204 480 232 800 260 880 286 600 318 060 343 700 371
THKRMINOL PR-3
Enthalpy TU/Lb.
4.28 1647 26.06 41.28 68.38 82.20 33.40 08.16 119.26 191.77
144.73
151.11 177.92 102.24
pectfte Haat Tharmal Cendaet TU/Lb.-*F. TU/FL', Hr., F./Ft
0482 0445 0.255
0.2622 0.2714 04790 0.2384 0.2660
0.3064 0.9136 0.3223
0.3308 0.3363 0.3470
0.08700 0.06680 0.06034
0.05620
0.08698
0.08558 O.0S813 0.06466
0.08416 0.06300
0.08302 0.06241
0.05178 0.05107
Penalty Lb./Oal.
13.008 12.780 12.834 12.202 12.081 11.829 11.897 11.386 11.134 10.002 10471 10.430 10.207 0.070
Vlaeaelty Lb./Hr.--Ft.
.
1828.0 101.84 24.282 12.081 7.116 4.669 3.306 2.476 1.037 1.8090 1.3098 1.1133 0.97891
Vapor Free. mm. Hg. Aboelutc
6 24 88 114 223 739
MONS 049525
VISCO*ITY-TMPRATURI CHART DINBiTV AND RKOIRIO ORAVITV
MONS 0<952t
SPECIFIC GRAVITY--6 MS/CC
PtCIPIC Ml AT '
HONS 049527
' n i/M L . FT*. F.fFT.
SPECIFIC HEAT BTU/LB..
8PBCIFIC HEAT OP
PR Its Relationship to Density
Specific heat--the quantity of heat required to raise the temperature of a material one degree, compared to the heat required to raise a like mass of water one degree--compares the material with water, pound for pound.
When comparing specific heat values of THERMINOL FR liquids with correspond ing values of other heat transfer fluids, it is important to note that the density of THERMINOL is much higher than the den sity of other fluids commonly used in heat transfer. In consequence, the heat capacity of THERMINOL fluids is greater than imme diately apparent from the specific heat values.
In transferring heat, a volume of fluid is circulated to give up or absorb heat and the heat capacity of that volume of fluid is the
When a comparison is made on a volume basis (as illustrated below), THERMINOL
liquids are comparable to other organic liq uids and superior to some:
SPECIFIC HEATS OF VARIOUS FLUIDS at ROOM TEMPERATURE
Pounde/ Gal.
Specific Heat Heat Capacity
(BTU/lb./ (BTUfeal./
F.)
THERMINOL FR 2 Organic Fluid "A" Petroleum OH
12.03 8.82 7.8
0.276 0.376 0.378
3.32 3.33 2.M
THE FLUIDS
THERMINOL FR liquids are unique. They permit installation of a non-pressurized sys tem operating with a liquid which has no fire point, and will not support combustion. THERMINOL FR liquids are so fire-resist ant they have been lifted with Underwriters' Laboratoriesl
Because of this extreme fire resistance and its recognition by insurance companies, impor tant savings can be made in designing a process heating system around THERMINOL FR fluids. The savings include not only the lower capital cost of non-pressurized equip ment, its simplified installation and lower maintenance; but also elimination of some of
the costly safety devices required in equip ment circulating a flammable fluid at or above its fire point. These economise show up both in the type of components needed and in the layout of the system.
Still another unique property of THERM INOL fluids is their unusual chemical inert ness. They are among the most oxidationresistant compounds known. This inertness prevents the formation of oxidation eludgee if the hot fluid comes in contact with air. This extends the useful service life of the heat transfer fluid; occasionally allows economies in design. However, THERMINOL FR fluids are not intended for use in open vessels but in properly vented, closed systems.
HONS 0495^0
Chemically, THERMINOL FR fluids are resistant to strong acids, mild alkalies, and dilute solutions of strong alkalies.
THIRMAL STABILITY
THERMINOL FR fluids are thermally stable. They are manufactured to meet strict thermal stability specifications. Each produc tion run is tested in Monsanto's laboratories with special equipment developed by Monsanto to assure that these fluids meet the high standards of thermal stability. Any material which does not meet these standards is rejected.
It is characteristic of almost all organic mate rials to undergo chemical change when ex posed to high temperatures for long periods of time. The type of chemical change depends upon the molecular structure of the fluid; the degree of change depends on the temperature, and the length of time of exposure.
THERMINOL FR fluids resist chemical change up to temperatures of 600F. and show no measurable change after years of exposure to such temperatures. Exposure to temperatures above 600F. -- even localized overheating will only cause some formation of "high boilers": molecules of THERMINOL FR will join together to form larger molecules quite similar to the original material, but higher in viscosity and in boiling point. These high boilers are soluble m the fluid up to reasonable concentrations; so overheating only increases the fluids' room temperature viscosity slightly. When a concentration of approximately 5-10 percent "high boilers" has been formed, however, the viscosity begins to rise quite sharply.
With this change, small but measurable amounts of dry hydrogen chloride gas are evolved. This should be removed from the system by appropriate venting. When THERMINOL FR fluids operate at high bulk temperatures, or, where some local over heating may occur, the system should be designed to prevent moisture from condensing in the vapor spaces where this hydrogen chloride gas is being vented.
When the hydrogen chloride is dry, it has little or no effect on metals in the system. However, if the hydrogen chloride dissolves in moisture, an acid corrosive to certain metals is formed. A properly designed heater and distri bution system operated at or below 600F., will allow use of the same fluid for many years.
While THERMINOL FR fluids normally are operated to a maximum temperature of 600*F. --systems specially designed for operation at higher temperatures have proved successful. At higher temperatures--"high boiler" forma tion with attendant viscosity increase is, of course, accelerated and a shorter service life must be expected. However, side stream dis tillation can be employed to constantly re move higher boiling materials while the sys tem is in operation. Periodic make-up is added to replace the quantity of the high boiler material removed.
An alternate procedure for higher tempera ture operation, which is sometimes more suitable for smaller installations, is periodic replacement of the THERMINOL charge, reclaiming the used fluid by straight take over distillation. (Monsanto should be con tacted for details regarding this procedure.) On systems containing only 60-100 gallons of THERMINOL, it is usually most economical to periodically discard the entire charge and replace it with new fluid.
THSRMINOL SYSTEM DESIGN
When designing a THERMINOL FR system it is important to remember this fact: THE FLUID CAN BE NO BETTER THAN THE SYSTEM! THERMINOL FR liquids are ideally suited for high temperature preci sion heating and temperature control applica tions, but only if the heater and distribution system are properly designed, constructed and operated. While there is nothing profoundly different or complicated about a THERM INOL system, certain design parameters must be rigidly observed if the system is to operate trouble-free, efficiently, and with realization of the full benefits of heat de livered by a liquid.
MONS 0^9529
Two basic heater designs for THERMINOL fluids are available: the liquid tube and Are tube types. In liquid tube heaters, the THERMINOL is pumped through the tubes at a definite flow rate as it is heated; in fire tube types, THERMINOL flows through the "shell" of the heater surrounding the fire tubes.
Wheh operating temperatures of 500F. (or higher) are required, a liquid tube type heater is to be preferred . . . unless a specific design is devised to force a steady flow over the heat donor surfaces.
Since THERMINOL fluids transfer heat in liquid form, they do not form vapor to ac celerate convection circulation. To avoid hot spots in a THERMINOL heater, the fluid should be pumped over the heating surfaces so that no area of stagnant fluid occurs.
Fluid velocities over the heat donor surfaces should be relatively high; generally 4 to 10 feet per second. This helps avoid both exces sive fluid film temperatures and also reduces the quantity of fluid in the high temperature film that is in direct contact with the heat donor surface.
The illustration shows the effect of fluid velocity on film temperature and indicates the importance of this design requirement.
EFFECT OF LIQUID VELOCITY ON FILM TEMPERATURE DURING HEATING
High Liquid Velocity
Low Liquid Velocity
Importance of Fluid Velocity and Film Tem perature through Heater
A bulk fluid temperature of 600F. and a maximum film temperature of 640*F. assures long service life of THERMINOL FR fluids. Note the significance of "maximum" film temperature: heating ia not uniform in fired
MONS 049530
heaters, and maximum conditions--not average--mut be used to determine the recom mended 640F. ceiling.
Example: The film coefficient for THERMINOL in a given heater is 250 BTU/hr. sq. ft., F., and the fluid temperature is 570F.
The average radiant absorption rate is 9,000 BTU/sq. ft., hr. The maximum ra diant absorption rate is 17,000 BTU/sq. ft., hr.
The average film temperature is then
--s- -
but the maxmium film temperature is . !' - w
Past experience shows that when purchasing a heater, the buyer should insist that design and capacity provide optimum film tempera ture for the fluid.
The method of Lobo and Evans0 is useful in calculating film temperatures in radiant heaters.
When electric heaters are used--heat flux is more even. However, it is important to re member that all of the heat from the electric element passes into the fluid. The watt-density on the surface of the heater tube and the fluid velocity past the tube should be in proper
balance to avoid excessive THERMINOL film temperatures. Watt-densities in the range of 8 to 10 watts per square inch with a minimum velocity of 4 feet per second are suggested. However, watt-densities in the 18 to 22 watt per square inch range have proved satisfactory in properly designed installations.
Heaters for THERMINOL should meet local code requirements. However, the fire resist ance of THERMINOL FR fluids will often permit important economies in the design and placement of fired heater equipment. With gas-fired heaters, the THERMINOL unit need not be placed outside of the building or isolated in a fireproof structure unlees the use process requires such precaution. Steam or inert gaa smothering devices can generally be eliminated and a vapor tight firebox to retain smothering gases is not necessary.
The fuel for THERMINOL heaters is purely optional. Gas- or oil-fired heaters, and elec tric resistance heating are all used with success. Coal-fired heaters are generally not recommended because of their slow response to change of load at the heat source.
The over-all thermal efficiency of a fired heater will generally be comparable to steam boilers of similar size. Efficiencies of 75 to 80 percent can be expected when convection sections are added. Efficiencies of 60 to 70 percent are achieved with only a radiant section.
Lobo. W. E., and J. C. Evana. Trana. AiChC. 35, 743 (1939)
MQNS 049531 t
20
FLUID HEAT SYSTEM...
In selecting pumps for a THERMINOL system, it is important that the pump ca pacity and pressure head bo sufficient to circulate the fluid at the rate demanded by the particular installation. For large flow rates, the fluid circulating pump should gen erally be the centrifugal type and any one of a number of brands of standard high tem perature centrifugal pumps designed for hot liquid service is suitable. Dean Brothers, Worthington, Ingersoll-Rand and Chempump for example, are all used satisfactorily. For most THERMINOL systems, cast steel pumps are best. Pump manufacturers usually specify that above 450F. fluid temperatures, a water jacketed, deep stuffing box or me chanical seal and water-cooled bearings be used. Mechanical seals are used widely today.
It is suggested that with a stuffing box, eight rings of packing be provided. Durametallic No. D-110, Garlock No. 736 and equivalent packings are satisfactory for the pump, and an open, non-overloading impeller is desirable to handle the cool, relatively viscous liquid at start up.
Whan s new system is first put into operation, a slight leakage may be noticed at the pump packing. It is not advisable to tighten the pump gland, however, until the system has heated up close to the temperature of operation.
Canned pumps such as Chempump Series T require no seal and have proved very service able in THERMINOL systems. Small gear
pumps are also used successfully in THERM INOL FR service because the fluids have good high temperature lubricating properties. However, gear pumps characteristically de crease in pumping capacity after extended use. When gear pumps are used, care should be taken in selecting the capacity so there is a margin that will assure adequate flow through tho heater. Regardless of the type of pump selected, the flow rate should be checked regularly against its performance when new.
To avoid shaft trouble and leakage at the seals, it is important to provide adequate expansion joints and to support the piping in a way that avoids stresses on the body of the pump. Direct-connection pumps driven by 1,750 rpm. motors are most commonly used. Each pump should be fitted with a control to switch off the burner in case of pump failure.
If expansion loops are used in the pump suction piping, they should be horizontal or vertically downward. They should not be vertically upward, for in such a position they form a trap which can collect air and non condensibles, and seriously hamper the pump's performance.
PIPING...
The most important factors in the piping layout for a THERMINOL FR system are; (A) Proper sizing for the required flow rate And (B) minimizing pressure drop. Because the system will undergo temperature changee,
HONS 049533
adequate expansion joints and loops to relieve expansion and contraction stress are essential.
Generally. Schedule 40 seamless steel pipe is used with THERMINOL FR systems. It is characteristic of most organic fluids (includ ing THEKMINOL) to have a tendency to leak through joints and fittings at high ternperatures unless these fittings are very tight. Therefore, flanged joints should be used sparingly to minimize potential leak points.
Threaded connections are used with THERMINOL FR up to a one-inch maxi mum size. Care is required in cutting the threads to assure a proper fit; a clean, new die is recommended. Careful attention to threading procedure should provide a good threaded connection. It is not wise to rely upon the use of pipe dope to eliminate leak age. However, pipe dope should be used. Q-seal (Quigley Company, Inc.); Plastiseal (Johns Manville); and Crane'B No. 425 are all UBed successfully in THERMINOL FR systems.
In larger size pipes, welded connections should be used wherever practical. Careful layout and use of curved sections of pipe can mini mize the welded or flanged connections re quired. When a flanged connection is made, 150 pound raised face flanges are recom mended. The flange should be backwelded to the pipe and proper gasketing used. Spiral wound (Spiratalic or Flexitallic) asbestos and stainless steel gaskets are good. Small lip spiral wound gaskets are preferred over the wide lip type, because they allow better compression with the 150 pound flange. Garlock short fiber, pre-cut and cured as bestos gaskets have also proved satisfactory.
It is recommended that high temperature bolts, such as Crane Triplex steel bolts, which do not stretch, be used.
All high points in the piping system should be provided with vent valve connections.
VALVBS...
One hundred and fifty pound cast steel valves with deep stuffing boxes are satisfactory for THEKMINOL systems. Cast steel ball valves
designed for high temperature (such as offered by Hills McCanna have also proved very effec tive, particularly where quick open-and-close action is desired.
ROTARY JOINTS...
It is wise to take particular care in the in stallation and maintenance of rotary joints in order to assure long service life and mini mum leakage. Install such joints with proper flexible connections to assure alignment at all times. Rotary joints should not be operated in a new system until the system has been thoroughly cleaned of abrasive particles which could score the sealing faces and cause leak age. Rotary joints such as those manufac tured by the Johnson Corp. and Perfecting Service Co. are satisfactory with THERMINOL FR.
TH BXRANSION TANK...
Proper design of the expansion tank for the THERMINOL system is quite simple, but is also very important to proper system operation.
Characteristic of moat organic liquids, THERMINOL expands in volume about 4 percent for every 100F. temperature rise. In heating THERMINOL from room tem perature (70F). to 600"F., the fluid in the system expands about 20 percent. Therefore, the expansion tank should be large enough to accommodate about 20 percent of the total volume of the entire system, including the fluid content of the heater, piping and all heat users. The tank should be sized so it is about one quarter full when the system is cooled to 70F. and three quarters full when the system is at a maximum operating temperature. The expansion tank should be fitted with a sight glass at the "full'' range and with a float operated, low-level switch to shut off the burner in case of accidental fluid loss in the system.
Place the expansion tank in the circuit on the pump's auction side--above the highest point in the system.
The expansion tank also serves as the major venting point of most THERMINOL sys-
MOWS 049534
12
twnB' The temperature of the fluid in the expansion tank ia much lower than the bulk fluid temperature in the system. Connect the expansion tank to the system with a small diameter line to avoid thermal recirculation. However, make this line large enough to readily pass the flow caused by expansion and contraction in the system and to permit recirculation of fluid for moisture removal as explained below.
Because THERMINOL FR fluids are fire resistant, the vent need not be isolated from potential sources of ignition. However, the vent should be out of doors, particularly away from working areas, to eliminate pro longed or repeated contact with the vapors.
Care should be taken to prevent the entry of atmospheric moisture into the system as the expansion tank 'breaths' air. The vent can be equipped with an air dryer, such as a calcium chloride pot or other desiccant.
An alternate procedure would be to blanket the expansion tank with nitrogen. However, if thie is done, the THERMINOL system should be dried thoroughly before the system is sealed with nitrogen.
In systems using THERMINOL above 600F. (or in systems where accidental high film temperatures may occur in the heater) some provision must be made for venting any hydrogen chloride gas formed in the system and to assure that the system remains dry. Gas or water vapor will not escape readily through the "cold seal" connecting the ex pansion tank to the THERMINOL system. It is advisable to provide a pipe to feed a small side stream of hot THERMINOL through the expansion tank as illustrated at right to allow hydrogen chloride and water vapor to flash from the fluid. A small stream of hot THERMINOL from near the pump discharge should be piped directly into the vented expansion tank, so it enters the tank above the highest liquid level. A globe valve should be installed in the line to permit throttling the flow to the desired rate.
Experience shows this simple procedure to be extremely effective and completely satisfac
tory for removing hydrogen chloride and moiature from the THERMINOL system. Analysis of samples drawn from systems operating with such a device show that the THERMINOL fluid maintains minimum acidity and holds moisture at the low levels equivalent to newly manufactured fluid, even after prolonged periods of operation. Provision should be made to prevent moisture from condensing in the vapor space above the liquid level in the expansion tank and in the vent. It is advisable to trace and insulate the expansion tank and the vent so that any moisture accidentally entering the system will remain as a vapor and will not condense. This will prevent corrosion of steel and elimi nate the need for higher cost alloys. The use of non-metallic vent pipe is also recom mended. Polyester piping (available from Fibercast), resin lined steel piping or other non-metallica resistant to THERMINOL vapors and to hydrogen chloride are com mercially available and have been used with great success.
NOT1S. .. The expansion tank and vent should be traced and Insulated. If steam Is not available at the site, hot THERMINOL fluid can be passed through steel tracing tube.
HOMS Q49535
13
TESTINO FOR LKAKAOI.. .
When a new system has been installed, it is important to test for leaks. Probably the most widely used technique is to check for leaks with ammonia gas. In this method, the system must be relatively dry and sealed. All vent valves should be closed and a tem porary pipe cap or slip blank installed at the expansion tank vent and at other points where there is no valve.
Ammonia gas is fed into the sealed system followed by air under pressures up to ten pounds per square inch. Any leakage areas can be readily detected by the escape of ammonia. Tiny amounts of ammonia vapors can be made visible as white smoke by directing a small stream of hydrogen chloride gas over each joint or fitting, and around each welded connection. Any leakage points can be marked, tightened, and then the system purged free of ammonia with plenty of air.
A satisfactory alternate procedure is Halogen Testing: in this procedure, introduce one pound of Freon F-12 or Freon F-22 for each fifty cubic feet of volume of the system. Carefully introduce air not exceeding 10 psig of pressure. At this air pressure, the con centration of Freon will be sufficient to give a sensitive test.
Attach a halide torch to an acetylene tank and light it. Using the H inch flame as a probe, explore for leaks by passing the end of the flame along seams and joints. If a leak is present, the escaping Freon will be drawn
into the acetylene flame turning it green. A large leak will produce a violet color.
Leak testing with water is not recommended. Though effective, it creates a problem of introducing a large amount of water into the THERMINOL system which will be hard to remove.
CLEANING THE SYSTEM...
After testing for leaks and making any required adjustments, the system must be thoroughly cleaned.
A new system will contain dirt, weld and mill scale and other foreign particles. Unless re moved, these particles will be carried in sus pension by the circulating THERMINOL. They may "lodge" in valves, controls, mechancial seals, rotary joints and other mechan ical equipment, causing faulty operation or component failure.
When purchasing the heating equipment, the supplier should be requested to clean the equipment as thoroughly as possible using brushes, wiping rags and suitable solvents, such as tri- or perchlorethylene.
When completed, fill the system with the operating charge of THERMINOL. Bring the system up slowly to approximately 200*F. At this temperature, the viscosity of THERMINOL will be very low. The turbu lence from this low viscosity, plus the excel lent solvent action of THERMINOL fluid, will further clean the system. Circulate the warm THERMINOL through the system without operating rotary joints (if they are installed in the system).
FILTERING...
Install a strainer, made of ordinary fine mesh screen backed up with M' screen, in the pump suction of the new system. As foreign material collects, this screen should be peri odically removed and cleaned. When, after several days during which the strainer col lects no material, remove it permanently from the line. The system should be heated and cooled for a minimum of two cycles with the suction screen in place, since the resultant expansion and contraction will loosen mill
MUNS 049536
W
, j ^
v i .
j
;
G
14
scale. The screen may be placed in the main stream line, gasketed between two flanges.
It is advisable, when operating where solids and contammaut-s might enter the system, to permanently install a high temperature filter on a by-pass line that can be isolated with valves for periodic cleaning.
CONTROLS...
Controls for heating systems using THERMINOL should be installed both on the heater itself and on the heat-using units. A wide variety of thermal-operating controls are available, and any reliable standard equip ment is satisfactory.
Install heater controls to regulate the firing mechanism in direct proportion to the re quired output. These controls should increase or decrease the heat in-put to maintain the THERMINOL at the operating temperature required by the heat-demand of the user. Small units may be operated satisfactorily by relatively simple "on-off" or "high-low" con trollers; larger units will operate more uni formly if equipped with modulating tem perature controls.
Install user controls to regulate the flow of the heat transfer fluid in proportion to the heat-consumption of the heat-using equip ment. In a multiple-user system, separate controls should be installed on each consum ing unit, to assure tho proper heat-delivery.
Safety Controls. In addition to activating controls, the heater must also be fitted with the proper safety controls to meet the local code requirements. Safety controls should include;
a. High temperature cutoff at tho hoater outlet... to shut off the burner in the event of an excessive temperature rise.
b. High tube wall temperature cutoff. A thermocouple sensing element should be installed in contact with the radiant heated surface at the highest temperature point in the heater and protected as much as possible from direct or reflected radiation. Such a controller is usually of the on-off type with the switch wired into the flame
safety circuit so that the burner is shut down when the switch opens. Aside from protecting the tube bundle, this safety con trol protects the THERMINOL fluid from overheating. c. Low flow cutoff. This control will shut down the burner should flow rate drop below design rates, or if a loss of flow occurs due to pump mal-function or failure. Equip burners with regular automatic ignition controls and flame failure controls. In wide range firing operations, an over-fire draft con trol will increase the economy of the opera tion. Electric power failure and instrument air failure safety controls are also desirable. In general, the practice of "fail-safe" instru mentation and control is essential: use good quality indicating and recording gauges, with scales calibrated for the particular limits of operation for best reading accuracy.
HONS 04953^
IS
OPERATION AND MAINTENANCE OP THE THERMINOL. SYSTEM
*
The following recommendations are intended only as guides. These suggestions are sup plemental to the equipment manufacturer's recommendations as they relate to the par ticular heater or the user equipment in the installation. The following comments on start-up, shut-down, power failure precau tions, and periodic fluid check-ups apply generally to all sizes and types of equipment.
NSW tYSTIM START-UP...
For a new installation, or an existing system that has been drained and ia idle:
1. Check the safety and control devices. Check the safety and control devices for proper installation, proper range settings for the operation, and actual operation (by manually activating the instrument).
For protection of the over-all system and for predictable long fluid life, it is vital that all instruments and controls perform properly.
2. Check for leaks (see section on leak testing, page 14.)
2. Pull Vacuum on System.
a. The vacuum should be pulled from a point of high elevation in the system; usually at a point just below the expansion tank. Prior to drawing a vacuum, dote all valves to the expansion tank; close all valves and vent connections to the atmos phere; close all valves to non-pressure equipment in the system (such vessels may collapse under vacuum) and open all valves in the interconnecting piping of the system.
b. Turn on vacuum equipment and evacu ate theentire system (including the "users") to 26-27 inches of mercury vacuum (if possible), or until the absolute pressure of the system has reached the limit of the available vacuum equipment.
c. Shut off vacuum equipment.
4. Charge the System with THERMINOL.
a. Fill the expansion tank with THERM INOL, and introduce the fluid slowly into
the system through the expansion tank valve until the tank is almost empty. Close the valve and again All the tank. Open the valve allowing the fluid to enter the system and repeat until it no longer flows by gravity.
b. Open all valves then start the main circulating pump in accordance with the manufacturer's recommendations. Observe the liquid level in the expansion tank re peating "a" above until the system has been filled. The thermal expansion of THERMINOL must be allowed for in determining the cold charge level. (A 20% expansion can be expected when heated to 600F.--as a guide, the expansion tank should be 70-76% full at the hot operating condition.)
c. Circulate the THERMINOL fluid through the system for about 3 to 4 hours to eliminate air pockets and to assure com plete fill of the system.
BEFORE FIRING HEATER, BE SURE THAT THERMINOL IS CIRCULATING FREELY.
5. Fire Heater.
a. On new installation start-up, or after prolonged shut-down, bring the system up to temperature slowly--about 100*F. per hour. This will prevent thermal shock to heater tubes, tube/header joints, refrac tory materials, etc., and allow operators to check the functioning of instruments and controls and become familiar with the equipment's operation. The slow heat-up will also allow any moisture trapped in the system to escape as a vapor.
b. Bring system to operating temperature and put "users" on the line.
DAILY START-UP ... when equipment has been shut down overnight or for week ends, follow this procedure:
1. Start the circulating pump and check the expansion tank level to see that the
HONS 049536
>
16
THERMINOL is at the proper cold-start level (H-full).
2. Start burner at the "low" flame setting and continue full circulation until the THERMINOL bulk temperature reaches 180F.
3, Turn heater up to full heat.
SHUT-DOWN . . . should be performed as follows to avoid overheating:
1. Shut off burner completely with circulating pump still operating. Continue to run the pump at full capacity for at least 30 minutes to dissipate residual heat in the combustion chamber of the burner.
2. Shut ofT circulating pump after H hour, and switch ofT all heater electrical controls.
COLD WtATHIR PRECAUTION ... When the THERMINOL system is exposed to low ambient temperatures, it is often most practical to leave the system "idling." Turn the burner to "low" position, and allow the fluid to circulate continuously at about 200F. The unit will then be "at ready" for imme diate high-temperature operation, and the viscosity of the fluid will remain low and workable.
IN CASK OP POWIR PAIUURI...
The burner circuit should be shut down by the heater controls. When the power comes on, run tho circulating pump for a few momenta to eliminate any vapor pockets that might have been formed by the fluid remain ing static in the hot combustion chamber. If there is no knocking in the piping system, full-flre may be resumed immediately if the fluid temperature is above 180*F.
PERIODIC CHICK-UPS...
The regular maintenance inspection schedule should include the manufacturer's recom mendations, as well as inspection of the THERMINOL. Following is a listing of in spection check-points:
1. Lubrication of moving parte.
2. Operating fidelity and accuracy of readings
of safety controls and temperature limit controls.
3. Inspection of heater tubes, burner, refrac tory linings.
4. Periodic inspection of heater surfaces.
5. Inspection of water cooling at the circu lating pump.
6. Repacking of stuffing boxes (according to manufacturer's specifications).
7. Semi-annual or annual sampling and anal ysis of THERMINOL.
Under normal operating conditions, it should not be necessary to check on the condition of the fluid more than once or twice annually. The analysis for fluid condition is a simple test of fluid viscosity. The exact viscosity limits will be affected by the specific mode of operation and can vary somewhat from sys tem to system. Monsanto should be contacted to determine specific values for the intended operation. Most users do their own testing; some have the viscosity determination made by an outside laboratory. A simple test kit for in-plant testing of THERMINOL is available at a low cost.
Customers can have their fluid tested by Monsanto free of charge. For sampling con tainer and application data form, write to:
MONSANTO COMPANY FUNCTIONAL FLUIDS MARKETING ORGANIC CHEMICALS DIVISION ST. LOUIS, MISSOURI 83166
Analysis results will be returned to the cus tomer with complete recommendations for improving or continuing the performance of THERMIN.OL heat transfer liquid.
MOMS 0<*9539
TYPICAL --^hormJjnLnLlL PR SYSTEMS THE HEATINO PLANT
18
HEATING A SINGLE USER:
2 FRC=FLOW RECORDER CONTROLLER WITH LOW LIMIT CUTOFF TO BURNER
Note that the user temperature can be controlled by either (a) rate of flow of THERMINOL to the user, or (b) temperature of THERMINOL, varied by fuel Input to the heater.
MBATINO MULTIPLE USERS:
PUMP
FRC--FLOW RECORDER CONTROLLER
3 WITH LOW LIMIT CUTOFF TO BURNER
Note that each user can be controlled at a different temperature by control of the flow of THERMINOL and therefore the rate of flow of heat offered.
HONS 049541
1
r
HONS 049542
4
20
ft
SinQle heater system provides varying THERMINOL temperatures to users ... finds application lor processing heat-sensitive materials.
r- ^ t- - ^-----.Tiinnrinrmri m--man ir
'
,lTr 'trin'ir-i-nn'rrmnMiii-twifijiijm
MONS 0495*3
21
O
c
thermlfua
FR ENGINEERING DATA
The design and installation of THKKMINOE indirect heating systems requires a heat balance between the user(8) and the heater. The amount of heat which will be absorbed by the user in a given time depends upon the over-all heat transfer coefficient, the heat transfer area of the user, and the mean temperature difference between THKRM1N0L and the process or area being heated.
In processing most organic chemicals, oils, food cooking -- the rate of heat transfer is usually dictated by the process and not by the heating medium. However, in designing a system- it is important to know the heal transfer coefficient of THKRMINOh. This is affected by a number of variables, probably the most important of which is flow rate.
The following curves provide engineering data on THERMINOL heat transfer coefficients as a function of flow rate ... and pressure drop as a function of flow rate ... in various common sizes of pipes and tubes.
NOTE: The following charts depicting heal transfer coefficients
and pressure drops for various sizes of pipes and tubes are
available in full page reproduction for greater accuracy In Inter
pretation. Write to:
Monsanto Company
Organic Chemicals Div.
800 N. Lindbergh Blvd
St. Louis, Mo. 63166
MOMS 049544
I*
22
THERMINOL FR-1
10
10 90 40 50 70 100
tOO 900 600 1000 2000 4000 6000
FLOW--G.P.M.
HEAT TRANSFER COEFFICIENTS INSIDE TUBES
HONS 049545 23
THERMINOL FR-2
H*AT TRANSMR OOBPPIOlBNTS INSIDB SOHEDULI 40 PIP* ^ FLOW--G.P.M.
24
C O E FFIC IE N T
THERMINOL FR-3
HEAT TRANIFIR COEFFICIENTS INSIDE SCHEDULE 40 FIFE
HEAT TRANSFER COEFFICIENTS INSIDE TUBBS
MQNS 049547
THERMINOL FR-t PRESSURE DROP IN SCHEDULE 40 PIPE
PRESSURE 0R0P-P.S.1. PER I X FEET
FLOW-G.P.M.
HONS 0495<*8
20
THERMINOL FR-2
JURE DROP--P.5.1. PER 100 FEET
PRESSURE DROP IN TUBES
HONS 049549
27
THERMINOL FR-3
PRESSURE DROP IN SCHEDULE 40 PIPE
PRESSURE DROP IN TUBES
MONS 049550 2H
RESISTANCE OP VALVES AND PITTINOS TO PLOW OP PLUIDS
A simple way to account for the reaietanco offered to flow by valve* and fitting* I* to add to the length of pipe in the lino a length which will give a preenure drop equal to that which occur* In the valve* and fitting* In the line.
20oo
Example: The dotted line *how that the resistance of a 6-Inch Standard Elbow I* equivalent to approximately 16 teot of
6-lnch Standard Steel Pipe.
"i
42-
ai
0-
24
SB --
20' 18--
tE
I Close Return Bond
U4 jjSudden*tfilargement I----- d/O-X
t
lOrdinary Entrance
< > 5
A-4(Sudden Contraction , 2
K\L-d/D-X Y--tf/O-K '------d/O-tf
E-
5 4tf --
< X -- < *-
iTM
*H
ix-
> 45 Elbow
MONS 049551
PRESSURE DROP AND HEAT TRANSFER RATE FOR HEAT EXCHANOERS
Parti
PROCEDURE TO OBTAIN PRESSURE DROP SHELL SIDE OF TUBULAR EXCHANGERS WITH THERMINOL FR-2
1. Enter Chart No. 1 with GPM & average flow ing temperature-read average shell side velocity.
2. Multiply average shell side velocity with baffle correction (Be--Chart No. 3) to obtain cor rected velocity.
3. Enter Chart No. 3 with corrected velocityread uncorrected pressure drop.
4. Correct pressure drop-3 above-for temper ature, tube diameter and tube length.
Example:
THERMINOL FR-2 400*F.
20" Shell %" Tubes on 15/10"
Baffles
12" Pilch
Tubes
10' Long
400 GPM
1. Chart No. 1 400 GPM-20" shell--2.7 ft/ssc. average velocity.
2. Chart No. 3 12" Baffle Pltch-0.0 correction 2.7 ft/sec. x 0.6*1.02 tt/sec. corrected ve locity
3.1.02 It/sec. In 20" Shell * 4.1 PSI uncorrected preesure drop.
4. Correct for temperature, tube size and length. Pressure Drop 4.1 x 1.2 x 1.0 x 1.33 * 6.64 Ans.
Pari II
PROCEDURE TO OBTAIN HEAT TRANSFER RATE SHELL SIDE OF TUBULAR EXCHANGER8 WITH THERMINOL PR-t
1. Enter Chart No. 1 with GPM at average flow ing temperature-reed average shell side velocity.
2. Multiply avorage shell aide velocity with baffle . correction (Bel, Chart No. 2) to obtain cor rected velocity.
3. Enter Chari No. 2 with corrected velocity-
read uncorrected h.
,
4. Correct h-(3 above)--for temperature end tube diameter.
Example:
THERMINOL FR-2
20" Shell 1" on V/"
Baffles
10" Pitch
3009
360 GPM
1. Chert No. t 350 GPM-20" Shell *2.35 fl/sec. average velocity.
2. Chert No. 2 10" Baffle Pilch--0.078 correction 2.35 ft./sec. x 0.875 * 2.00 ft./sec. corrected velocity
t. 2.00 ft./tec. Chart No. 2 * 226 uncorrected h.
4. Correct h for temperature end lube diameter. 225 x 0.01 x 0.66* * 121 Ana.
Pert III
NOTES:
a. Tubee to be on triangular pitch %* on W on 'W; 1" on 1
b. All baffles cut 1 row of tubes past horizontal centerline.
c. Charts have base condition-- %" on %*;
Baffles at 8" pitch. THERMINOL FR-2 at 550F.
Data on Shell aide pressure drop and coefficients Courtesy of Struthera Walla Corporation.
HUNS 04955^
80
---------------------- 1 Norn. Shell Diameter Inch**
r-
Tube
Length Feel
i-
6 12
16 24 16
UNIT SELECTION CHART ARRANOEMENT
%'O.D. on No. of Tube*
96 96 6
114 114 164
(86 48 432 432 632
Trl. Surface Sq. Ft.
24 48
86
160 224
822 412 662 684 660 1192 1710
W O.D. on No. of Tube*
28
48
82 82
120 152 208 252 814 814 474
Trl. Surface Sq. Ft.
20 40 75
120 183
283 958 400 863 740 85 1485
1* O.D. on No. of Tube*
14 14
2$
48 48
66 82 110 138 174 174 268
1V4" Trl. Surface Sq. Ft.
15 30
65
101 151
208 256 946 434 546 790 1122
a
rrr
ir*a
M0N5 049553 3)
CHART NO. 1 AVIMOI SHtlX SIDB VELOCITY
0
GJPM. A$
92
ELL SOE VELOCITY--ffT./'SEC.
CHART No. 2 HEAT TRANSFER SHELL SIDE
MGNS 049555 33
CHART NO. 3 PRESSURE DROP SHELL SIDE
C
R DROP-PSI CORRECTION FACTOR
049556
k in e m a t ic vrscgsmr, in c e n t is t o k e s
G R A V ITY , IN OEGREES A P I.
0
VISCOSITY CONVERSION CHART (Converting Kinematic and Saybolt Viscosity to Absolute Viscosity)
i- 10.000
8,000
1,500- r
1,000
900 800 700 600 500
400 J
800
5.000 4.000 8,000
'.ooo 1.500
0)
Os
a
if)
8,000
800-T 160 -f 750
<2
500 <00
-800 60 850 <0-3
800 I 800
I?
F- 80 5
1.4 1.8l.f-1
1.0-J 10 1> 2
50 0.7-j 70
0.6
0.5 -
r-'
HONS 049557
ENGINEERING CONVERSION FACTORS
MULTIPLY
ATMOSPHERES ATMOSPHERES ATMOSPHERES ATMOSPHERES ATMOSPHERES ATMOSPHERES British thermal units British thermal units British thermal units British thermal units British thermal units British thermal units British thermal units Btu/cu. ft. Btu/hr. Btu/hr. sq. ft. Btu/(hr. sq. ft. 0 F.) Bfu/(hr. .q. ft. 0 F.) Btu/(hr. sq. ft. 0 F.) Bfu/(hr. iq. ft. 0 F.) Btu/(hr. iq. ft. F.| (Btu/hr. q. ft.)/( F./in.) (Btu/hr. sq. ft.J/( F./n.) (Btu/hr. sq. ft.)/( F./ft.) (Btu/hr. iq. ft.)/( F./ft.) (Btu/hr. sq. ft.)/( F./ft.) Btu/mln. Btu/min. Btu/min. Btu/lb. Btu/lb. mol. Btu/lb. 0 F.
BY
14.70 2116.8 760 29.92 33.90 1.033 s I0` 778.2 107.6 1055 0.2520 3.930 * 10-' 2.930 I0-* 0.S556 8.90 3.927 x 10 * 2.712 4.882 1.0 1.356 x 10-' 5.68 x 102.035 x IO-* 12.9 3.945 i I0-* 4.13 x IO-> 0.0173 14.88 12.97 0.02358 0.01758 0.556 0.556 1.0
TO OBTAIN
lb./sq. in.
Ib./tq. ft.
mm. Hg.
in. Hg. ft. of water
kg./sq. meter
ft. ib.
kg.-mofers
joules kg.-eal. hp. hr.
W. hr.
P.C.U.*
kg.-eal./eu. meter
hp' kg.-cal./hr. sq. meter
kg.-cal./(hr. sq. meter 0 C.)
P.C.U.*/(hr. sq. ft. C.)
gram-cal./sec. cm.* 0 C. waHs/cm.* 0 C.
watts/sq. In. F.
(kg.-cal./hr. sq. meter)/( C./cm.)
(gram-cal./sec. cm.*)/( C./cm.| (gram-cal./sec. cm.*)/( C./cm.) (watts/cm.1)/!0 C./cm.)
(gram-cal./hr. em.*)/( C./cm.)
ft. Ib./sec.
,
hp.
w.
gram-cal./gram gram-cal./gram mol. gram-cal./gram 0 C.
,
*Poun4`C#nt!gr4* Unit
30
MONS 04955a
MULTIPLY
Btu/sec.
Btu/sec. Btu/sec. Btu/sec. Btu/sq. ft. Btu/sq. fl. CALORIES CENTIMETERS CENTIMETERS
cm. H9. cm. Hg. cm. Hg. cm. Hg. cm. Hg. cm. Hg. cm./0 C. cm./sec. cm./sec. cm./sec. cm./wc. cm./sec. CENTIPOISES CENTIPOISES CENTIPOISES CENTIPOISES cubic centimeters cubic centimeters cubic centimeters cm.Vsec. cm.'/>ec. cm.Vsec. cm.'/tec. em.'/grem em.'/grem mol.
CUBIC FEET CUBIC FEET
ENGINEERING CONVERSION FACTORS
BY
778.2 1.4147 1.0549 107.6 0.2712 2.712 See grem*cal. 0.3937 0.0328
0.01316 0.1934 27.85 136.0 5.353 0.4461 0.2187 1.969 0.03281 0.036 0.60 0.02237
0.01 2.42 6.72 > 10- 3.60 0.06102 3.531 > I0-* 2.642 1 10- 2.119 I0-* 0.0864 0.01585 3.6 0.01602 0.01602
0.02832 7.481
TO OBTAIN
ft. Ib./iec. hp.
lew. kg.-meter/sec. grenvcel./cm.* kg.-cal./sq. meter
In. ft. etm. Ib./sq. in. Ib./sq. ft. kg./sq. meter in. of water ft. of water in./0 F. ft./mln. ft./sec. km. /hr. mefers/min. mph poises Ib./ft. hr. Ib./ft. sec. kg./meter hr. eu. in. cu. ft. gal. eu. ft./min. cu. meter/day gal./min. liter/hr. cu. ft./lb. cu. ft./lb. mol.
cu. meters gel.
MGNS 049559
ENGINEERING CONVERSION FACTORS
MULTIPLY
BY
CUBIC FEET CUBIC FEET cu. ft. gas (60 F. at 1 atm) cu. tt./lb. cu. ft./min. cu. ft./mln.
cu. ft./tec. cu. ft./sac. tq. ft. CUBIC INCHES CUBIC INCHES CUBIC INCHES CUBIC INCHES CUBIC METERS CUBIC METERS cu. metars/day
dagraas/sec. degreos/sec. ERGS FEET FEET ft. of wafar ft. of wafar ft. of wafar ft. of watar ft. of wafar ft. of watar ft./mln. ft./mln. ft./mln. ft./mln. f*./c. Il./uc. fl./wc. FOOT POUNDS
FOOT POUNDS
FOOT POUNDS FOOT POUNDS
28.32 62.43 2.636 x 10 "* 62.43 472.0 0.1247 44B.B 0.0305 16.3? 5.7B7 x I0-* 0.01639 4.32? x I0-* 35.31
264.2 11.67
2.779 x I0-* 0.1667 1.0 x 10-' 30.48 0.3048 0.02?5 2.242
0.8826 304.8 62.43 0.4335 0.508 0.01667 0.0182? 0.01136 1.097
IB.29 0.6818 1.285 x IO-`
3.239 x 10
3.766 x 10 5.05 x I0-T
TO OBTAIN
liters lb. of watar lb. mol. cm.'/gram cm.'/sac. gal./sac. gal./mln. Illcr./.ec. cm.* cm.' cu. ft. Ilt.rt gal. cu. R gal. cm.'/sac. rev./sec. rpm joules cm. matars atm. cm. Hg. In. Hg. kg./sq. matar Ib./tq. ft. Ib./sq. In. cm./see. ft./sac. km./hr. mph km./hr. matars/mln. mph Btu kg.-eal.
kw. hr. hp. hr.
wj
MOMS 049560 38
ENGINEERING CONVERSION FACTORS
ft. lb./min. ft. Ib./mln. If. Ib./sec. If. Ib./sec. ft. Ib./sec.
ft. Ib./sec. GALLONS (Imperial) gal. (U.S.) 9al. (U.S.) gel. (U.S.) gel. (U.S.) gal./hr. gel./mln. gel./min. gal./min. gal./min. of wafer GRAMS GRAMS gram mole gas gram-cel. gram-cal./gram gram-ceL/gram mol. gram-cal./gram 0 C. gram-cel,/cm.* (gram-eal./cm.*)/cm. gram-cal./(tec. cm.* 0 C.) (grem-cal./sec. cm.')/( C./cm.) gram-cm. gram-cm. gram-cm. gram-cm. grami/cm. grems/cm.*
grami/cm.' grami/cm.* grami/cm.* grami/cm.* grams/cm.*
3.03 x I0-* 2.26 x 10-" 0.0771 1.818 x 10-" 0.01943 1.356 x 10-'
1.201 231 0.1337 378$ 3.785 3.71 x 10"' 2.228 x 10-" 0.227 0.06309 500.8 980.7 2.205 x 10-' 2.24 x 10* 3.968 x 10-' 1.8 1.8 1.0 3.687 1.452 7.373 x 10' 2.903 x 10* 9.294 x 10-' 980.6 7.233 x 10- 2.342 x 10-' 5.60 x 10-' 1.0 62.43 0.0735S 10 0.394 0.03281
10 OITAlN
hp.
Itw.
Btu/min. hp. kg.-cat./min.
Itw.
gal. (U.S.) cu. In. cu. ft. cm.* liters cu. ft./sec, cu. ft./iee. cu. meferi/lir. Itteri/iec. Ib./hr. of wafer dynes lb. cm.' gas (0 C. and 760 mm.) Bfu Btu/lb. Bfu/lb. mol. Btu/lb. F. Btu/sq. ft. (Bfu/sq. ft.)/in. Btu/(hr. sq. ff. 0 F.) (Btu/hv. sq. ft.)/( F./ln.) Btu ergs ft. lb. kg.-cal. Ib./in. specific gravity at 4 C. Ib./cu, ft. cm. Hg. kg./sq. meter in. of water ft. of water
ENGINEERING CONVERSION FACTORS
MULTIPLY
gremt/cm.a grams/cm.* grerm/em.1 HORSEPOWER HORSEPOWER HORSEPOWER HORSEPOWER HORSEPOWER hp, (boiler) hp. (boiler) hp. hr. hp. hr. hp. hr. hp. hr. hp. hr. hp. hr. hp. hr. INCHES in. Hg. tn. Hg. In. Hg. In. Hg. In. Hg. in. of water in. of water In. of water In. of water In. of water In. of water In./0 F. KILOGRAMS KILOGRAMS KILOGRAMS KILOGRAMS kg.-metort kg.*meters kg.meter* kg.-meter*
*fim^Ciitl(r*d* Unit
40
BY
9.678 x 10 -< 0.01422 2.048 42.41 2.3 x 10* 550 10.7 0.7457 3.3479 > 10* 9.804 2.845 > 10* 1.98 x 10* 2.684 > 10* 641.2 2.737 10* 0.7457 1.414 > 10* 2.54 0.03342 1.133 0.4912 70.73 345.3 2.458 10'* 0.07355 0.1869 26.40 0.03613 5.202 4.572 9.807 x 10* 70.93 2.205 1.102 x 10-' 9.302 x 10' 7.233 2.344 x 10- 2.724 x I0-"
TO OBTAI
atm. Ib./sq. in. Ib./sq. ft. Btti/min. ft. Ib./mJn. ft. Ib./tec. kg.-eal./min. kw. Btu/hr. kw. Btu ft. lb. {ouiei kg.-cel. kg.-meter* kw. hr. P.C.U.* cm. atm. ft. of w.f.r ib./iq. in. Ib./q. ft. kg./sq. meter atm. In. Hg. cm. Hg. kg./sq. meter Ib./sq. in. Ib./iq. ft. cm./0 C. dyne* poundel* lb. tons (short) Btu ft. lb. kg.-cal. kw. hr.
HONS 049562
MULTIPLY
kg.mafars kg./eu. matar kg./cu. matar kg./matar kg./sq. matar kg./sq. matar kq./iq. m.t.r kf./iq. m*Ur kg./$q. meter kq./iq. mUr KILOMETERS KILOMETERS km./hr. km./hr. km./hr. km./hr. KILOWATTS KILOWATTS KILOWATTS KILOWATTS KILOWATTS KILOWATTS kw. hr. kw. hr. kw. hr. kw. hr. kw. hr. kw. hr. LITERS LITERS LITERS LITERS LITERS lltars/gram mol. Iltars/hr, liters/kg. litars/min. lltars/mln.
ENGINEERING CONVERSION FACTORS
Y
6.165 a I0-* 1.0 a I0-* 0.06243 0.6720 9.678 a I0-* 7.355 x I0-* 3.281 a I0-* 2.896 a I0-* 0.2048 1.422 a 103.281 a 10' 0.6214 27.78 64.68 0.9113 16.67 56.92 4.425 x 10* 737.6 1.341 14.34 1 a 10' 3.413 a 10' 2.655 x 10* 1.341 3.6 x 10* 860.5 1.895 a 10' 1 X 10' 0.0353 61.02 0.2642 1.057 16.02 0.2778 0.01602 . 6.0 a I0` 5.885 a 10-
TO OIT>
P.C.U.* gram/cm.1 Ib./eu. ft. Ib./f9. atm. cm. Hg. ft. of water In. Hg. Ib./tq. ft. Ib./sq. In. . ml. em./ic. ft./mln. ft./sac. maters/min. Btu/mln. ft. Ib./mln. ft. Ib./c. hp. kg.-cal./mln. watts Btu
ib. hp. hr. {oules kg.-cel. P.C.U.* cm.* cu. ft. cu. In. 9*1- (U S.) ql. (Ilq.) cu. ft./lb. mol. cm.-'/sac. cu. ft./lb. cm.yhr. cu. ft/sec.
*limd-Cinltf(idi Unit MGNS 049563
engineering conversion factors
MULTIPLY
litert/mln. litert/mln. litert/iec. cm.* METERS METERS meters/0 C. mefars/min. metert/mln. metert/min. mefert/mln. melert/iec. mefert/iee. meters/sec. OUNCES OUNCES OUNCES (fluid) OUNCES (fluid) ox./sq. In. ROISES ROUNDS ROUNDS ROUNDS lb. mob gat lb. of water lb. of water lb. of ~weter/hr. lb. of water/hr. Ib./cu. ft. Ib./cu. ft. Ib./cu. In.
Ib./ft. hr. br.
Ib./gal. Ib./ln. Ib./tq. ft. lb./4. .
IY
IS.85I 4.403 i 10-> 32.8 3.281 39.37 1.824 1.667 0.05468 0.06 0.03728 196.6 3.6 2.237 28.35 0.0625 1.80$ 0.02957 1.732 y 4.448 i 10s 453.6 32.17 379.4 0.01602 0.1198 2.669 IO-< 1.997 x I0~* 0.01602 16.02 27.68 1.488 4.13 I0-' 0.413 0.1198 176.6 0.01602 4.882
TO 08TAIN
gai./hr. gai./sec. cu. ft./tec. tq. ft. ft. in. ft./0 F. em./iae. ft./tec. km./hr. mph ft./min. Itm./hr. mph grams lb. cu. )n. Uteri In. of water gram/cm. tec. dynet grami poundalt cu. ft. gat (60 F. at I atm.) cu. ft. gal. cu. ft./min. gal./min. grams/cm.' kg./cu. meter gramt/em,* kg./meter grami/cm. tec. cenfipoitet gramt/cm.* gramt/cm. ft. of water kg./tq. meter
HUNS 099564
ENGINEERING CONVERSION FACTORS
MULTIPLY
BY
TO OBTAIN
ib./iq. ft. Ib./iq. In. Ib./sq. In. Ib./tq. In. Ib./sq. In. Ib./tq. In. Ib./tq. In. REFRIGERA7ION-STD. TON SQUARE CENTIMETERS SQUARE CENTIMETERS SQUARE FEET SQUARE FEET SQUARE FEET SQUARE INCHES SQUARE INCHES SQUARE INCHES SQUARE KILOMETERS SQUARE KILOMETERS SQUARE METERS temperature 0 C. 273 temperature C. 17.8 temporaturo 0 F. 460 temperature F. -- 32 TONS (long) TONS (long) font (metric) tom (metric) torn (short) font (short) font (shorfj/sq. ft. font (thorf)/tq. ft. font (thorfj/iq. In. tom (short)/sq. In. tom of refrigeration WATTS WATTS WATTS
6.944 * I0"1 0.06804 2.307 2.036 BI.7 703.1 144 200 1.076 x I0-* 0.1550 929 144 0.0929 6.452 6.944 x I0-* 6.452 x I0" 1.076 x 10' 0.3861 10.76
1.8
0.5555 1.016 x 10s 2.24 x 10' 1 x 10* 2.205 x (O' 907.2 2 x 10' 9.765 x 10* 13.89 1.406 x 10 2 x 10* See refrigeration 0.05692 I x I0T 44.26
Ib./sq. in. atm. ft. of water in. Hg. mm. Hg. kg./sq. meter Ib./iq. ft. Btu/min. sq. ft. sq. In. tq. cm. iq. In. tq. meters
sq. ft. sq. meters sq. ft. sq. ml. sq. ft. abs. temp. K. temp. 0 F. abs. temp. 0 R. temp. C. kg. lb. kg. lb. kg. lb. kg./sq. meter Ib./sq. In. kg./sq. meter Ib./sq. in.
Btu/mJn. ergs/sec. ft. Ib./min.
% MONS 049565
ENGINEERING CONVERSION FACTOR8
MULTIPLY
WATTS WATTS WATTS WATTS WATT HOURS WATT HOURS WATT HOURS WATT HOURS WATT HOURS WEEK WEEK WEEK YEARS (common)
BY
0.7376 1.341 x I0~ 0.01434 1.0 x IO- 3.413 2.65S x 10' 1.341 x 10' 0.8605 367.1 168 1.008 x 10( 6.048 x 10* 8.76 x 10'
m Si.
TO OBTAIN
ft. Ib./ioc. hp. kg.*col./min.
kw.
Btu ft. lb. hp. hr. kg.-cl. kg.-motor hr. min. soc. hr.
STEEL. PIPE DIMENSIONS--CAPACITIES AND WEIGHTS*
NomlMt OullM*
Will
.l4i*,0*Ik,
Him., lch*4K thick, hi. N*. nwi, in.
K 0-S40 40
H om 40
H 0.440 40
H 40
1 1.31$ 40
m
1.450
40
IK
1.440
40
40
2K
tl
40
)
t.MO
40
)H 4.000 40
4.S00
40
1
I.S4)
40
Mil
40
40
II 10.7$ 40
40
.004 HI 10) .11) .IS)
.140 .14) m .M3
in
m 337
363 .M0 31? .MS .404
to A. A. A. StMdwdi 1)1-10.
IntM* Him..
in.
M4 .4)9 .12) .014 1.040 I.J40 1.410 2.047 2.441 3041 3544 4.024 $.142 4045 2.401 10.020 11.431
CronMCtlOMl
UH m*t*l, iq. tn.
inWi wcUomI
rt*. iq. II
.12$ .142 .250 .333
414 .44) .244 1.02$ 1.204 2.224 2400 112) 4.904 $.504 1.344 11.40 15.77
.00072
.0013) .00211 .00371 .00500 01010 .01414 02330 .03322
.0SI30 04470 .01440
.1340 .2004 4474 .$475 .7771
iCqII.l.r,feto.wrpni*fwtifr*liint.e,M*s.( lonilh
OutM* IntMi
.141
.177 420 .27$ 444 .4)$ .444 .127 .753 .417 1047 1.174
1454 1.734 2.251 2.114 9.331
0454
.1243 .1130 .2151 .274$ .342 .422 $42 .447
404 JO 105$ 1422 1.540 2.040 2420 9.19
CiPKily H 1 It. p*r uc. wlettly
U. S. Lb. Mr hr. 1*1. Mr *i*r
min.
.373 .696 244.0 .44$ 1445 132$ 2.140 1,3450 4.57 434 104$ >492 7.440.0 2300 11.5000 SOM 11.4000 345 14.4000 423 400 IS.0000 1557 77.4500 245.0 123.000 0 34)0 174,500 0
W*)*hl <v Mill.
lb
53.1
MQNS 049566
TYPICAL APPLICATIONS FOR " thePITlJLiTLnJl'=
LIQUID HEATINO SYSTEMS...
Indirect liquid healing with THKKM1N0I. Fit Byetems is recommended wherever lowpressure, high-temperature proc essing- requiring safe, uniform delivery of heat-- is needed. Here are a few typical applications.
)
. -i' /'
,V
f A ' v
V- r 'zkm
CHEMICAL PROCESSING . . . especially where flammable materials are handled.
VARNISHES AND RESINS PROCESSING ... where a single "circuit" with multiple users and varying temperatures is desirable.
PLASTICS AND RUB8ER MOLDING . . . where uniform heating, rapid temperature flux, and pin-point control is essential.
BITUMINOUS MATERIALS HEATING ... for maximum safety where explosive gases and volatile fumes occur.
FOOD PROCESSING ... for controlled, quality "cooking" of potato chips, pre-cooked soups, other foodstuffs.
MATERIALS CONVERSION ... to heat corrugating rolls, crimping presses, calenders.
METALS TREATING OVENS ... for heat-treating metals such as titanium and vanadium; for "seasoning" weldments, castings and forgings.
MALT COOKING AND LIQUID DISTILLATION ... for efficient indirect heating of distillation equipment.
HONS 049567
45
* -%
^hormJUrinlk fr SAFETY
OF HANDLING
' 4
iA
:
;/ ' '
On the basis of animal toxicity studies, THEHMINOL FK may be considered only slightly toxic from the standpoint of acci dental massive skin exposure or accidental ingestion. Similarly, single exposures to high concentrations of vapors (when heated suffi ciently to volatilize) or high concentrations of decomposition products (if the fluid is accidentally discharged into the Are chamber) are not serious hazards because the irritating character of such concentrations preclude vol untary exposure.
Repeated or prolonged skin exposure should be avoided since THKKMINOIj Fit acU as a solvent for fats and oils of the skin. Re moval of these natural, protective barriers can lead to drying and chapping such as occurs with exposures to paint thinners. More important, THEHMINOL FK may be ab sorbed if it is allowed to remain on the unbroken skin. For these reasons, we recom mend that the skin be washed with soap and water if there is contact. A skin burn resulting from accidental contact with hot fluid should be treated in the normal manner for any thermal burn due to hot oils.
Because of its low vapor pressure, there is no significant vapor inhalation hazard when THEHMINOL FK is at room temperature. For example, there is no vapor exposure prob lem while transferring the fluid from its ship ping container to the heat transfer system. On the other hand, the vapors emitted by THEHMINOL FH heated to elevated tem peratures are injurious on prolonged exposure. It is indicated that the `Threshold limit value'* or atmospheric vapor concentration which cannot be safely exceeded (on a daily basis) is 0.6--1.0 milligrams of THEHMINOL FH vapor per cubic meter of air in the workroom. In heat transfer installations, the fluid must be used in a closed system free from leaks with the expansion tank vented to the out doors. Accordingly, there should be little or no opportunity for workers to come in con tact with vapors.
MONS 049568
t
40
#
t
I
HONS 049569
I
I
\
MONS 049570 i-om io utmo.
HONS 049571
Ai^J>xO-rJ!n.kmKS The following is a list of utilities supplied to the Pyranol mix area. Steam Steam Is supplied to the department through a 6" main at 120 psig. Standard practice on steam is 25 lbs/cwt. Recovered Water Water is not used in this department. Electricity Electrical power is supplied at 440 volts for power and 110 volts for lighting. Standard practice is 500 KWH/cwt,
MGNS 049572
MONS 049573
APPENDIX E - PERSONNEL Production of Pyranol mixes Is a part time operation. When these mixes are produced they do not require constand attention of an operator. All Pyranol mixes arc produced .by Aroclor department operators.
HONS 04957b
Me
HONS 049575
APPENDIX F - PACKAGING AND SHIPPING Pyrnnols ate packaged in 55 gallon steel drums, 33 gallon galvanised drums and five gallon steel cans. These containers arc transferred to warehouse for storage until time of shipment. Some Pyranols are loaded into tank cars for shipment. All tank cars are entered, cleaned and inspected prior to loading.
MONS 049576