Document BRjDyNN7xJ2BoeDXY2Y12jgQk

PLAINTIFF'S EXHIBIT K-1466 Johns-Manville Service to the Iron and Steel Industry JOMNS-MAWIt.tr PACJOU CTH Manuals of J-M Service to Industry--No. 107 DEFENDANT'S--EXHIBIT A~3t ^ INTRODUCTORY HE purpose of this book is to present, as completely and Tyet as concisely as possible, the service Johns-Manville offers in improving the operating efficiencies of Iron and Steel manufacturing processes. The blast furnace plant, the open hearth plant, the mill furnaces and the power plant have been given special attention in describing the application of insulation and refractory ce ments. Whether pig or wrought iron, open hearth or Bessemer steel, J-M products will decrease the cost of production. Blast furnace stacks, hot blast stoves, mains and bustle pipes function much more economically when properly insu lated, as does also every furnace, regenerator, metal mixer, and waste heat boiler. In the by-product coke plant the utility of J-M materials is apparent at every turn: Insulation on the ovens, preheaters, and stills; packings on the gas, air and water apparatus; Transite for the quenching station in the yard; and built-up roofs on the buildings. In the rolling mills, sheet mills, tin plate mills, wire mills and pipe mills, J-M insulations, packings, refractory cements, brake blocks and roofings--economical, durable and efficient-- point the way to reduced operating costs by conserving heat, lessening deterioration, and maintaining production. For motive equipment--locomotives, shovels, drag lines and buckets, hoists, transfer bridges and loaders--Johns-Manville i i } 4 furnishes brake blocks and clutch facings, packings, insula tions, and housings of weather-proof and corrosion-resisting Transite. For all concrete construction--shafts, man-ways, portals, foundations and walls--Celite for Concrete adds to the work ability and insures permanence and water-tightness. For buildings, J-M roofings--built-up, insulated, ready-tolay--afford the maximum of protection and durability with the least maintenance in any climate. J-M shingles provide a roof, the appearance of which meets every architectural requirement. Transite roofing and siding used on steel frame construc tion is not only durable under the most adverse atmospheric conditions, but requires no painting or other maintenance. For the power plant -- boilers, pipe lines, pumps, com pressors--there are J-M insulations for all operating temper atures; refractory cements; packings for steam, air, surface or mine waters, and oil; Asbestos Ebony for panel control boards: Orangeburg Fibre Conduit and other electrical specialties. The number and variety of J-M products and the magni tude of the Iron and Steel Industry preclude complete discus sion of every application in a book of this size. Detailed spec ifications for the use of any J-M material, as well as drawings and other engineering data based on long and specialized experience, are available on request. Johns-Manville The Blast Furnace Plant HE proper use of Johns-.Vlanville insulation production of pig iron. In the following pages will Tand refractory materials for the blast furnace be found descriptive recommendations based on stack and hot blast stoves, mains and bustle applications which have been found successful in pipes is a great factor in the present-day economicballast furnace plant operation. Blast Furnace Stack An important application of insulation, which is now being employed satisfactorily by a number of plants, is the insulation of the blast furnace stack. Sil-O-Cel Coarse Grade is used, packed between the inwalls and the shell of the stack, above the mantel, as shown in Fig. 1. Sil-O-Cel acts as a cushion between the refractory and shell, preventing the rivet shearing action en countered when densely packed loam or granulated slag is used. Sil-O-Cel is inert chemically and cannot react upon the brick or shell as might be the case with loam, due to lime content. The effect of the Sil-O-Cel insulation is to give a more uniform heat gradient through the lining with more uniform ex pansion and a lessened possibility of cracks forming. The shell is also protected against excessive tem peratures. A number of plants are insulating stacks because of the above advantages as well as to mmimi/e the building-up action ol the refractory lining vine to condensation and chilling of zinc vapors or other impurities in the ore. Because a more uniform heat is maintained through the refractory, the vapors are carried through into the Sil-O-Cel. where condensa tion takes place. By virtue of its great porosity. SilO-Cel will absorb condensed vapors ei|ual to SO per cent of its volume. mately 3 ft. at a time, then tilling in and tamping the Sil-O-Cel Coarse Grade in place. Refractory Cement Recommendations To prevent the heat from entering the inwalls through cracks, thereby softening the brickwork at some distance from its surface, and also to reduce spalling, the brick in the blast furnace is set up with refractory cement, as in dicated by zones in Fig. 2. J-M No. 30 Refractory Cement is used in laying STCCL SHCU. st-o-ca. co*sc ca*oc n# 9*/e* Sil-O-Ce! Insulation Recommendations The J-.M recommendation for the insulation of blast furnace stacks consists of from in. to 4 in. of Sil-O-Cel Coarse Grade extending from the man tel to the bottom of wearing plates (see Fig I). The Sil-O-Cel Coarse Grade should be packed in the space between the brick lining and the steel -.hell tn a density of 22 Ih. per cubic loot. I bis i% best accomplished by carrying up the brickwork approxi -SifO-CCl CM ***** --*t*C 9**C* tl in tLL, 41 __________ J : 5 1 !11 | rJ-1 u: I--Method of Iv>liating Blvst Plknaci. Si\*k. Main and Bustle Pipe JoHSS-M VXVIU.E StRVICF. 10 THE I K0\ \M> Mhtl. ImiLs'IKV the bottom blocks, the hearth. hoh. and lower inwall brick. J-M NcS. 20 Plastic Refractory Cement is em ployed in the middle inwall and the top. J-M No. 30 Refractory Cement i> particularly resistive to the action of blast furnace slag and the erosive action of materials passing through the furnace in the blast. In the bot tom blocks, it prevents metal pene tration and cuts down labor costs, because by using No. 30 it is not necessary to chip off the blocks to level each course. J-M No. 20 Re fractory Cement strongly bonds the metal wearing plates to the brick and resists the cutting action of the ore. limestone and coke fed into the furnace at the top. Ilf, 1--Remucturs Cemf.st Reccim- Mt\lHTIO\S FOR Typical Bust Plr'.acf. Hot Blast Stoves The problem of sufficient hot blast stove capacity to enable the operator to supply high hot blast tem peratures becomes more pronounced with modern demands for greater uniformity in iron composition. Another element is the increased use of blast furnace gas for metallurgical operations, which renders deMrable further fuel economies in the stoves. Ade quate insulation of the hot blast stoves offers an obvious means of meeting each of these requirements. The approved insulation for stoves consists of 2)4 in. of Superex Blocks next to the shell, with 4'4 in. of the fire brick lining immediately inside the Superex replaced by 4)4 in. of Sil-O-Cel C-22 Brick. The older practice made use of Superex only, but the method which replaces 4)4 in. of fire brick with SilO-Cel C-22 Brick has proved highly advantageous and well justified by the excellent return secured on the additional in\estment. The following table shows the per cent return on insulation investment for the two types of construction, figured for a stove ot re cent design. Definite recommendations appear on succeeding pages. Value heat loss Value heat saved Est net cost per vear at We ov er uninsulated ot insulation per million B.t.u. stove installed Stove uninsulated ............................................... $8,430 Stove Insulated with 2)4 in. Superex Blocks on shell and dome and 6 in. Sil-O-Cel C-3 Concrete under base ................................. 4.110 $4,320 3,770 Stove Insulated with 2) ' in. Superex Blocksand 4'4 in. Sil-O-Cel C-22 Brick on shell and dome and 6 in. Sil-O-Cel C-3 Con crete under base......................................... 3.240 3.100 6.41>D Per cent vearlv gross return 113 ft S4'; The Blast Furnace Plant Cement and finished off Hush with the top ui the rivet heads. Superex Insulation of proper thickness is then placed over the cement fill so that the face of this material will be flush with the face of the adjoin ing insulation. In constructing the brick lining immediately next to the Superex. Sil-O-Cel C-22 Brick A'/i in. thick is laid to form the outer course of the brick wall. No bond is used between the fire brick and the Sil-O-Cel C-22 Brick. Sil-O-Cel C-3 Concrete, instead of Superex, is used in the same thickness as adjacent Superex around the hot blast outlet for 2 linear feet in each direc tion. This C-3 Concrete is prepared by mixing SilO-Cel C-3 and portland cement in the proportion of four parts of C-3 to one part of portland by volume, and adding sufficient water to make a plastic mixture. Walls, Recommendation "B"--\\ here the steel >hell is built with shingle lap joints <see Fig. 61, Superex Insulation and Sil-O-Cel C-22 Brick are applied as above, except that Superex is used in spe cial cut sizes to fit each section, tapering from 2 Id in. thick at the top of each steel section to 2*4 in. thick at the bottom. A drawing should be furnished, giving all dimensions and the details of joints and rein forcing plates. VERTICAL SECTION &B Fig. 6--Sil-O-Cel C-22 Brick and Superex Blocks in Side Combustion Stove Johss-M vwille Service to the Iron \nd Steel Kdistrv Dome i For Recommendations "A" and "B") --This recommendation applies to the dome of a two- or three-pass stove, where a steel shell torms a housing over the insulation. As the dome is erected. Sil-O-Ccl C-22 Brick. 4' in. thick, is laid over the tire brick, and followed by 6 in. x 12 in. x 2 in. thick Superex Blocks with all joints closely butted. All Sil-O-Cel (.'.-21 Brick 'Mould be laid with a thin rubbed joint of Sil-U-Cel Mortar. Over the insulation a 7 i in. thickness of J-.M No. 302 Cement is troweled to a smooth finish i see Figs. 5 and h). The edges ol the insulation around the rebel plug in the dome are coated with J-.M No 20 Plastic Refractory Cement. M NO. 302 INSULATING CEMENT SUPEREX INSULATION Mmm IM aft COMBUSTION CHAMBER WASH- COATED WITH J-M NO. 32 REFRACTORY CEMENT SECT/ON A-A COMBUSTION CHAMBER WASHCOATED WITH j-ftNOSi refractory CEMENT FIRE BRICK BOWED WITH jm NO 32 REFRACTORY CEMENT surerex INSULATION `STEEL SHELL FIRE BRICK BONDED WITH J-MNOJ2 REFRACTORY CEMENT * lfK g?f>s -----------Fire BRICK BOWED > WITH J*M NO -32 v REFRACTORY CEMENT -------------SUPEREX INSULATION r: ----------J-M NO 302 INSULATING CEMENT SUPEREX INSULATION -STEEL SHELL \r: f -+ DETAIL SECT/ON OF SIDE WALL STEEL SHELL HOT BLAS SM.-0<EL C-3 CONCRETE VERTICAL SECTION B-ff Pig.7--StrtREX Block Ksu.wms in I hree-P^s Slow t 16 | The Bust Furnace Plant Superex Insulation Walls,Recommendation "C"--This recommen dation is intended for stoves built so that the alter nate sections have both edges lapping inside of the adjacent ones, to form an "in and out" lapping (see Fig. 7). The steel shell is assumed to be in. thick. The insulation consists of Superex placed between the fire brick and the steel shell as the work pro gresses. The insulation between the inner rings and the brickwork is 2J4 in. thick, and between the outer rings and the brickwork is 2)4 in. thick. All joints are closely butted and pointed up with J-M No. 302 Cement. The space between the rivet heads is filled in with J-M No. 302 Cement and fin ished off flush with the top of the rivet heads. Su perex Insulation of proper thickness is placed over the cement fill so that the face of the insulation at this point will be flush with the face of the adjoining insulation. Sil-O-Cel C-3 Concrete, instead of Superex, is used in the same thickness as adjacent Superex around the hot blast outlet for 2 linear feet in each direction. Sil-O-Cel C-3 Concrete Base--The base of the hot blast stove is insulated with a minimum thickness of 4 in. of Sil-O-Cel C-3 Concrete, protected by two 2'.- in. couise< of fire brick laid with broken joints 1 Fig. Si. Sil-O-Cel C-3 Concrete is made by mixing C-3 and Portland cement in the proportion of lour parts ol C-3 to one part of portland by volume. Care should be taken to avoid an excess of water. After thorough mixing, the C-3 Concrete is tamped into place. Walls, Recommendation"D"-\Vhere the steel shell is built with shingle lap joints. Superex Insula tion is applied as above, except that it is in special cut sizes to fit each section, tapering from V.4 in. thick at the top of each steel section to 2;i in. thick at the bottom. A drawing should be furnished, giv ing all dimensions and the details of joints and reinforcing plates. Dome (For Recommendations "C" and "D") --This recommendation applies to the dome of a two-pass or three-pass stove, where a steel shell forms a housing over the insulation. Superex Insulation, 2 in. thick and furnished in flat blocks 6 x 12 in., is applied over the fire brick as the dome is erected, with all joints closely butted (see Fig. 7). Over the insulation a Yt in. thickness of J-M No. 302 Cement is troweled to a smooth finish. The edges of the insulation around the relief plug in the dome are coated with J-M No. 20 Plastic Refractory Cement. Fic. 8--Method of Insulating Base of Hot Biast Stove Doors -J-M Special Braided Asbestos Rope i supplied as a groove packing on hot blast stovt clean-out doors as the best material to withstam successfully this severe service. Insulation o( Flues on Diehl Stoves In Fig. 9 is shown the method of insulating the flues used in conjunction with Diehl stoves. Flues are insulated with Superex Blocks. The stoves are insu lated in accordance with J-M standard recommend." tions. Refractory Cement Recommendation for Hot Blast Stoves Walls, Dome and Bottom--All fire brick in tl walls of the combustion chamber is bonded wit J-M-No. 32 Refractory Cement, and the expost brick inside of the combustion chamber is was coated with J-M No. 32 Relractory Cement. patching. J-M No. 20 Plastic Relractory Cement most satisfactory. r i7i |ohns-M wville Service to the Iron and Steel Industry --s Fig. 9-- Insulation nr Diehl Hot Blast Stove Flue to Stack Hot Blast Mains and Bustle Pipes In the matter of delivering high temperature blast at the tuyeres, the insulation of mains and bustle pipes is as essential as the insulation of the stoves. There can be no question of the desirability of this practice if reference is made to the numerous suc cessful installations of suitable insulation between the steel shell and the fire brick lining of mains, which have been in extended use. A lining failure in hot blast main or bustle pipe is, of course, an affair of no mean consequence. The cost of labor and materials incidental to repair is .a factor without importance compared to interruption of production and furnace difficulties. The superin tendent is well justified, therefore, who eves with suspicion the use of any but well-tried methoils and materials. Linings are subject to enormous stresses from fire brick expansion and general severe operat ing conditions, all of which demand the use of a high quality, mechanically strong insulation, capable of enduring high temperatures without harmful effect upon its physical properties. These specifications may seem hard to meet, but developments in this field have been rapid in the last few years, and the insulation of hot blast mains and bustle pipes now presents no problem. The cost of insulation is returned in full during the first few months' operation bv virtue of heat saving alone, to say nothing of longer life of refractories through heat equalization and improved furnace performance. Uninsulated main?, and bustle pipes lose large quantities of heat due to the comparatively thin lin ings employed. The method recommended for insu- I lit 1 > 1 X'l I't KV M.l. Pi. XX I Col<e Oven Insulation Recommendations A great main coke oxen plant' nnxx cmplm insulation tn insure maximum econonn uf operation. I hi- method ol insulating i- xlimxn in In;. 14. plant, such a' nil 'cparatorv ichcaict'. superheaters, stills anil tank>. Ha'i' arc iii'iilalcil with Sil-O-Cel C-t Concrete oxer the pnrtlaml cement concrete Inundation Sil- O-Ccl Natural Brick i' u>eil helix ecu lire brick and red brick in the regenerator walls. or .Superex Block' with a Transile or steel casing is employed. 'I he doors of the coking chambers and the Hash plates -SlcTIOXS ABOVk CiKOlM) are insulated with Sil-O-Ccl C-3 Concrete or Su- IOX..................................... perex Blocks behind the silica brick. Tops are most rio\..................... effectix'cly insulated xxith Sil-O-Ccl C-t Concrete oxer the 'ilica blocks. A paxer course is then laid oxer the C-t Concrete. -SkCIIOXs Bl-.I.OXX CiKOl M) J-.M Insulatmg .Materials are also used for insu- xi.Mhxnxriox....................... lattng piping and other apparatus in the hx-product i* xc.u Jo tn r 21 II--THE OPEN HEARTH PLANT Insulation' in the Open Hearth Plant pace 25 New Open Hearth Regenerators--Sections Above Ground t Superex Block Recommendation .................................................... Sil-O-Cel Brick Recommendation .................................................. 26 29 New Open Hearth Regenerators--Sections Below Ground Sil-O-Cel C-3 Concrete Recommendation...................................... 30 Existing Open Hearth Regenerators Sil-O-Cel C-3 ConcreteRecommendation......................................... 30 Open Hearth Fan-Tails and Slag Pockets............................................ 32 Open Hearth Furnace Hearths................................................................ 33 Open Hearth Flues ................................................................................... 33 Insulation of Soaking Pits............................................................................... 34 Refractory Cement Recommendations for Open Hearth Regenerators and Soaking Pits ................................................................................. 34 23 \\ I l| | "V-I ll U. I II I' I 1. v... | HK` I `.II 1 1 "I ll.-.K- 'MI I The Open Hearth Plant HE insulation of regenerators. slag pickets, fan- merous installations are now being attained bv this Ttails and lines is recognized a? an effective means. The regenerators ol everv important open method of increasin'; the elliciencv ol the open hearth installation made in the United State' during hearth process, and very substantial results on nruecent vears have been insulated. Insulation in the Open Hearth Plant The application of insulation to the open hearth furnace itself has been regarded as precluded by the fact that furnace operating temperatures so nearly approach the limiting temperatures of relractories ordinarily used in open hearth construction. A num ber of furnaces have been insulated under the hearths (in the pan) and also on the sloping back walls with very satisfactory results. The use of insulation in these locations is of great interest because of the enormous savings which are effected and because the structural members supporting the furnace are pre vented from buckling. In open hearth regenerators, which are mvariahlv insulated, the actual economies of operation are much greater than would be indicated by calcula tions based on increase in temperature ol preheated gas and air. because suitable insulation, properly ap plied. also minimizes leakage through regenerator walls. New and old chambers are insulated according to slightly different specifications because of con structional features involved, but the general effect is the same in either case because the additional heat saving which results from the better construction that may be used on new regenerators is matched by decreased leakage through cracked walls of old regenerators. Decreased fuel cost per Ion ol steel, increased speed of heats, diminished air leakage, increased line temperature to waste heal boilers, and more salisfactorv service in general, result from the proper 1 i Johns-M \n\III K MiKVk.r 'll'* Tilt Ikon IM) SltEL I MU > I KV FlC. I--PeKSPECTIV E CROSS-SECTION OE THE OPEN HEARTH REGENERATIVE SvSTF.M. Showing. in Heavy Lines, the Location of Ksllation use of insulation on open hearth regenerators. Some or all of these benefits are secured to a highly profit able degree in every case, and the many successful installations have conclusively shown that earlier fears as to possible ill effects on refractories were unfounded. Snaking pit furnaces and regenerator? benelif hr insulation in much the same manner a> ilu- open hearth, except that the lower furnace temperatures permit the application of insulation to all parts ul the (*us. This results in a more uniform soaking tem perature in all portions of the furnace: assists in the elimination of rolling difficulties that result Irom uneven heating; and, by conserving the heat of pre vious charges, soaking time for all stock except cold, high-carbon ingots may be reduced without forcing the burners and without danger of burning the steel. The efficiency of the soaking pit is usually less than 10 per cent. This efficiency can be materially improved by insulation ami actual cos! of upkeep reduced by minimizing temperature variation within the refractories. A suitable insulation and casing applied to the soaking pit and to the regenerator walls, with the elimination ot some common brick, raises air temperature and reduces leakage, increases production, and cuts operating costs. Insulation of New Open Hearth Regenerators SECTIONS ABOVE GROUND Superex Block Recommendation Regenerator Walls--On new steel-encased re generators built with soliil lire brick walls not less than M'j in thick, all exterior brickwork above the ground is insulated with 4 in ol Mipeiex I'dock' i'ee lug 2i. ITmiaces of tills type ale hull Imm llte nut'ide *n: that i'. the Inick'lavs .iml 'led casing are first erected, then the brickwork run up inside. The Superex, furnished in blocks 6 in. x 36 in. x 1 in., is placed between the shell and the brickwork .i' the brickwork progresses It is applied in two m. thick hirers, using broken joint construction ami w nil all tonus closely butted and pointed up with |-M \o W.2 Cement The thrust of a relies The Opfv IImkth Plwt S/L-O-CCL c-j CONCRET. -FIREBRICK -SUPEREr insulation SECTION E-F FIRE8R/CK- sil-o-cel c-j concrete SIL-O-CEL C-3 CONCRETE SUPERS* INSULATION -STEEL SHELL x SIL-O-CEL C-2E BRICK \ SECTION G-H Flo 2--Si. PI HI N. BlOCK R|Co\|.\h \milO\ loK SlUIONS AllnU liROl SD ON Ol'fc\ li Kl ol Nl K\|OK. Sll-0-Cl.L C-' C.oNiKIIE r>\ Sections IjMiiW (.'.KOI NT) IM) l NDER ii; oi Firn^cl Proper. Su-O-CfL C-22 Brick on IAn-I mi vnd Sim; Pocket Johns-Manville Service to the Iron and Steel Industry --firebrick SECTION E-F FIREBRICK SECTION J-K -SIL-O-CEL C-3 CONCRETE -SIL-O-CEL NATURAL BRICK . .r'TEEL SHELL -SL-O-CEL C-EE BRICK ssfflsssssa VVVVVVVVVUgg SECTION A-B-C-D FIREBRICKSIL-O-CEL C-3 CONCRETE SECTION G-N Pro 3--Sil-O-Ci.l Brick Kecom.menoat ms ior Sections Auove Ground on Offs IIfartii Regenerator. Sil-O-Cel C-3 Coscretl (is Sections Below Ground and L sder Hearth of Furnace Proper Sil-O-Cel C-22 Brick on Fan-Tail and Slag Pocket [28] I III I 'I'l.S II: \ K I I I Mi V\ I >IniuId imi iv carried mi ni'iil.limn .inn tile m. 111 pi.uc two ; 111 vii.it' "I |-M No 'lij ( .elllent brick >hwuU pw run solid in the arch-thrust channel are Irowelevl over tile 'urlncc I lie lii'l coal t> lelt to Regenerator Roofs- I In- recommendation iintended lor 'olid lire brick roofs .it le.i't l* in. thick I lie root 1? insulated with 1 in. tluck >iipere\ lii'Uproximatelv I j in thick la v ci v allowing from (> ! 24 hours between application ol 'iiccecdmg lavers ilrv with a rough surtace betore the application ot the second co.il. I lie second coat i' trowelevl to .1 'month lull'll. Sil-O-Cel Brick Recommendation Regenerator Walls - - \\ inn all exterior brickI-iinn Method ni . I prhi ill ion -lieinlorciilg rod worli above tile ground i' insulated with 4 .- in. ol aiul mesh are lirst erected .0 described above. Tin >11-< >-(lei Natural Brick instead ol >uperc\. the in sulation. furnished in standard lire brick size. l> in. x 4'_- in. \ 2' j in., is placed between tile shell and the brickwork as the work progresses 1 big. 4i. I11 oilier to construct a monolithic wall ot equal 111 sii 1 .i11 liu value at every point, it is necessary to lav up the Sil-O-Cel Natural Brick in a mortar of the same material, with the thinnest possible rubbed joint' This mortar is furnished at the rate of SO lb. per thousand brick. At the arches, the lire brick is carried through to the steel, as prev iously noted in the Superex recommendation. lation. applied in a single layer, with all joints lightly butted. Then a I '/< in. hexagonal mesh galvanized wire netting is stretched over the insulation and fastened securely at the edges by means of expansion bolts or staples driven in the brickwork. Alter the netting is Regenerator Roofs--When the roof is insu lated with l'/2 in. of Sil-O-Cel Natural Brick instead of Superex. the Sil-O-Cel is laid over the suriace in a single layer, with the bricks tightly butted together and finished with a slurry of Sil-O-Cel Mortar. I Ol 1 \ s- M \ \ V II l.l M-KVU.I. IO I HE IKON VXD MH.I. KllL'TItY Insulation of New Open Hearth Regenerators SECTIONS BELOW GROUND Sil-O-Cel C-3 Concrete Recommendation Regenerator Bases -- The entire base of the regenerator chambers is insulated with a minimum of 4 in. of Sil-O-Cel C-3 Concrete, covered with two 2!' in. layers of fire brick. Sil-O-Cel C-3 Concrete is made by mixing SilO-Cel C-3 and portland cement, either by hand or in a mechanical mixer, in the proportion of four parts of C-3 to one part of portland. by volume. An excess of water should be avoided. After thor- ut:"h mixing. the C-3 Concrete is tamped into place. Insulation of Existing O^T/ofTj-K SECTIONS ABC Fig. 6--Sil-O-Cel C-3 Concrete on Open Hearth Regenerative Chambers. The Insulating Concrete Is Applied to the Wails by .Means of a Cement Gun Sil-O-Cel C-3 Concrete Recommendation Regenerator Walls -- On old regenerator cham bers constructed either of solid fire brick or a com bination of fire brick and red brick, the insulation consists of a minimum of 4 in. of Sil-O-Cel C-3 Concrete l see Figs. 6 and 7). Cement Gun Method of Application --Before anv application of C-3 Concrete is started, the entire regenerator wall and steel work should be given a wet sand-blast with the cement gun. to wash olT thoroughly all loose mortar and dust from the brick work and remove loose scale, rust and paint from the steel work. After this sand-blasting, Yi in. reinforcing rods are placed through holes provided in the buckstays on approximately 3 ft. vertical centers, so that the rods will be as near as possible to 2 in. from the lace of the brick surface, thus placing the reinforcement m the center of the C-3 Concrete. To these rodv a 4 in. x 4 in. mesh of not lighter than No. 12 wne is securely fastened. [ 30 1 The Open IIe\rth Punt Sil-O-Cel C-3 Concrete is made by mixiiii; Sil-OCel C-3 and portland cement in the proportions ol four parts of C-3 to one part portland. by volume. An excess of water should be avoided. The C-3 Concrete i> then shot on the wall in ap proximately \:/i in. thick layers, allowing from t> to 24 hours between application of succeeding lasers. Form Method oj Application.-- Reinforcing rods and mesh are first erected as described above. The iiirms. cither ui wood or sheet metal, arc then erected so that the required thickness of Sil-O-Cel C-3 Concrete may be placed. After thorough mixing, the mixture is tamped into the forms. Forms should be left in place tor approximately 4S hours. Regenerator Roofs -- On old regenerators with solid fire brick roofs at least 9 in. thick, the roof is insulated with Sil-O-Cel C-3 i granular), spread out over the roof surface to an even thickness ot 2! 3 in. (see Fig. 7). n !* *V "4 > - 'V SECTION J-K -FIREBRICK -SIL-O-CEL C-3 CONCRETE i | SIL-O-CEL C-3 GRANULAR ' iWA^ Ax FIREBRICK StL-O-CEL C-3 CONCRETE SIL-O-CEL C-JICRANUIAR)- SECTION C-H Fic. 7--Sil-O-Cel C-3 Concrete Recommendation ior Existing Open Hearth Regenerator Insulation Johxs-.M\nville Service to the Ikon and Steel Industry Pig. 8--Opes Hearth Regenerators Insulated with Sil-O-Cel Insulation of Open Hearth Fan-Tails and Slag Pockets Bases--The entire base of both the I.in-tail aiul slag pocket is insulated with a minimum of 4 in. of Sil-O-Cel C-3 Concrete, mixed according to direc tions and tamped into place. Walls--The walls are insulated with Sil-O-Cel C-22 Brick or C-3 (granular) 4)1' in. thick. I he brick insulation, furnished in standard fire brick size. 9 in. x 40, in. x 2)T in., is placed between the shell and the brickwork as the brickwork progresses In order to construct a monolithic wall ol equal insulating value at every point, it is necessarv to lay up the Sil-O-Cel C-22 Brick in a mortar oi the 'ante material, with the thinnest possible rubbed joint' This mortar is lurnished at the rale oi Sti lb per thousand brick. The thrust ol arches should not be carried on the insulation, and the lire brick should be run solid lo the arch thrust channel. If Sil-O-Cel C-3 igranular) is used, it is packed in the space between the brick lining and the steel shell to a density ol 31 lb. per cubic loot. This i best accomplished by carrying up the brickwork approximately 3 ft at a time, then filling in and tamping the C-3 i granular) in place. Fan-Tail Roofs--The fan-tail roof is insu lated with Sil-O-Cel C-22 Brick or C-3 igranulari 21 _ in thick l lie Sil-O-Cel C-22 Brick is laid o\ei I lie Miriuce ot i he root m a single laser and lini'ln-d with a slum o| Sil-O-Cel Mortar. It s>il-0-< el 1 - i granular i is used il i- spread out o\er the ni| 'iirlace lo an e\en t 11 i c Is lie" ot 21.- inches. The Ope\ Hevrth Pl\st Insulation of Open Hearth Furnace Hearths The enure hearth anJ sloping back wall of the open hearth furnace is insulated with 3 in. of Sil-OCel C-3 Concrete, making proper provision for ex pansion. Immediately above the supporting steel work in the pan of the hearth, the C-3 Concrete is placed in monolithic construction I see Figs. 2. 3 and 7). Sil-O-Cel C-3 Concrete is maJe in the usual way and tamped into place after thorough mixing. The usual brick hearth construction proceeds after the C-3 Concrete has set. In certain instances it may be preferable to use 3 in. of Sil-O-Ce! C-22 or Super Brick instead of the Sil-O-Cel C-3 Concrete Fig. o--Ope\ Hearth Hevrth C .Furnace Designed by I'kkyn Engineering o igk tin. Insli.vtid with Sil-O-Cel Super Brick Si.ag I'ocklts. Ai.so Insulated with |-.M Matfriais I vik Cokpurviiun, Mii.vym.kei. Kegenervtoks and Files \\ is Insulation of Open Hearth Flues Open hearth (lues are completely insulated in base, sides, and over the top with at least 4 in. of Sil-O-Cel C-3 Concrete, outside the fire brick lining. Base --After thorough mixing, the C-3 Concrete is rammed into place, 4 in. thick, over the concrete flue base. Walls--Alter the base insulation is thoroughly dry. the brick line, including bottom -ide walls, and rool. is constructed Wooden or sheet metal Imni' are then erected so that 4 m ol Sil-(i-Cel C-3 Con crete may be placed between the forms and the brick work. I he C-3 Concrete is made as previously de scribed and. after thorough mixing, tamped into place. The forms are left in place for approximately 48 hours after pouring has been completed. Roof--When applying the 'iile wall insulation the application of Sil-< >-Cel C-1 ( ainctvte can be con tinued up over the rool and the material lamped min place, \ller thorough diving, the earth backfill may be placed over the line. Johns-M anville Service to the Iron \mi >ti:.ki. Kni'TR> Pic 10--Open Hearth Plle Being Insulated with Sil-O-Cel in Base. Sides and Over Top ,, Insulation of Soaking Pits Soaking pits are insulated in much the same man ner employed for open hearth regenerators. Three approved methods of insulating involve the use of Superex Blocks, Sil-O-Cel Natural Brick, and SilO-Cel C-3 Concrete. These methods are illustrated in Figs. 13. 14, and 13. Pic. II--Soaking Pits .at the Inland Steel Company, Indiana Harbor. Ind. Refractory Cement Recommendations for Open Hearth Regenerators and Soaking Pits \\all> Ntronitly bonded with retractors cement pre sent air infiltration and better withstand the destruc tive action of brick movements, as well as the flame impingement and daiiame action l or 1 hi >er\ice J-.M No. 2ll Plastic Retractors Cement or No 2< Refractors' Cement i> u>ed. pLKSXChi. UvtxS AND PRODUCER Gas MaISS Fig. 3--Ch.ap.mis-Stein Recuperative Billet Heating Furnace Insulated with Sil-O-Cel Billet Heating Furnace Insulation Recommendations These recommendations are based on an operat ing temperature of 2300 to 2600 deg. F. in the heat ing chamber. Furnace Walls This recommendation is intended lor solid fire brick walls not less than I3.' j in. thick, or lor walls built with a combination of not less than 13!; in. of fire brick and not more than 8 in. of red brick. All exterior brickwork is insulated with 2 in. thick Superex Insulation, furnished in blocks 6 in. x 36 in. and applied in a single layer with all joints closely butted and pointed up with J-M No. 302 Cement. Suitable openings are cut for doors, burners, etc. Around these openings the brickwork is carried through to the outside. Where the insulation is applied after the brick work is in place, a cement finish over the insulation is recommended. The insulation is secured in place by lacing it with No. 16 soft annealed wire to cables through holes in the buckstays as shown in Figs 2 and 6 All supporting steel is lelt sullicientlx exposed to present its reaching undue temperature. Oxer the insulation, I '/i in. hexagonal mesh galvanized wire netting is stretched tightly and fastened securely to the cables laced through the holes in the buckstays. Two J4 in. coats of J-M No. 302 Cement are applied over the insulation, the tirst coat being left to dry with a rough surface before the applica tion of the smooth tinislung coat. When an excep tionally hard finish is desired. J-M No, 302 Cement max- be mixed with poriland cement for the second ! j in. coat, the proportion of portland cement being from yi to '/i by sveight. depending on the degree of hardness required. If a more durable casing is needed. Transite max' be applied as shown in the detail of Fig. 2. or steel plate erected as indicated in Fig. 5. Either casing is supported by suitable angles or angle clips, spotwelded or bolted to the buckstays (see Fig. 3). The blocks are temporarily held in place until the casing is applied, by spotting them to the brick surface with J-M Fibrous Adhesive. Nexv furnaces are frequently steel cased in the original design. FTirnaces of this type are usually built Irom the outside in; buckstaxs and steel casings are first erected; then insulation anil brickxxork are H* ) Furnaces, Ovens and Producer Gas Mains Morgan Continuous Billet Heating Furnace (Oil-fired) with Side Walls Insulated with Superex Blocks Insulation of Heating Furnaces N intermediate furnaces which prepare stock for throughout the industry are so similar that standard I further rolling, such as billet, bloom, and slab insulation specifications have been prepared covering heating furnaces or sheet and pair furnaces, the materials and their application to the various de matter of uniform heating and dose temperature signs. The use of such standards should be governed join ml of u\cn more importance than in the soak by determining how close the installation under con ing pit. < 'xidi/mg conditions must be avoided in all part' ot the Itimace. because, with light sections, scaling wastes a very appreciable percentage of the sideration falls within the limits ot practice for which the specification was drawn. steel and causes other difficulties by cementing the pieces together or bv picking up bits of brick and sand which scab the surface of the finished material. Closer temperature control, more uniform heating and reduced air infiltration through the proper use of insulation in the furnace casing results in improved rolling conditions, less waste, a finer quality of prod uct and better working conditions. Furthermore, the saving in heat radiation from a properly designed job is. by itself, quite sufficient to pay a highly satis factory return on the insulation investment. There can be no justification, on a dollars and cents basis, for neglecting to provide adequate insulation in the construction of this class of equipment. For man_v furnaces in this group, the condition' I ml (>i'r \ I It- \r 111 Hi w r I io 12--Simmsf. Ckwf Ri.mowm; Hot Koot irom \ So*ki\o Pit ImiS'-M\s\ii 11 ii> 11 i i Ikhs ^ 111 i Km iki -S/L -0-CEL HA JURA L BRICK STEEL SHELL DRAIN TO SUMP -S/L -O-CEL NATURAL -S/L-O-CEL C-J CONCRETE | I,, 14--S'lVKIM. I'll l\MI\iltl\ (Million l'*l BRICK -SIL-O-CEL C-J GRANULAR- SIL-O-CEL C-J CONCRE TE DRAIN 70 SUMP SIL-O-CEL C-3 CONCRETE 'SIL-O-CEL C-J CONCRETE 1 : - k I *: i f\l I Ui-iN I \1. iINi ( ' <0 Johns-Mwvili.e Service to the Iron wd Steel Indl^tk'i KU/t*'** 0'Sw*+z~ ew *4LCS SC StTM. AHO* ~ I ft ^St '**-** ** 4'CO mrm ^ | ] f \ WfltMtttfU &A4ro "=r ! |--- ------- SCCTOM 0*0 DfTAiL OF INSULATION CONSTRUCTION ON SIOS NALLS. TRANSITS FINISH. CONSTRUCTION ON S/Of MILLS C*rNT Finish 1'lG. 1--GaS-HRED ReCLI'ERaTUE BlLU.T lltAlINO !;IRN\CE InSLLATIOV SuPEREX BLOCKS WITH Cement Finish or Transite Casing on Existing Furnaces [40] Johvs-Masville Service to the Iron and Steel Industry -ALATTOAt* OtSCHAAGC OOOA SECTION EE 600* CASING SfL-0-CL C-3 COKFCTt rmtHHCK DOOR DETAIL Fig. 4--Coal-fired L-tvpe Bar Heating Furnace Insulation. Superex Blocks and Sieei. Casino Included in Design on New Furnace Furnaces. Ovens and Producer Gas Mains laid up inside. The steel casing extends nom the floor to the furnace top and all joints between the sheets occur behind the buckstays. The corners of the casing are ordinarily secured by steel angles bolted to the outside of the plate. In places where arch thrust or other exceptional stress is transmitted to the buckstays, the insulation is omitted and the tire brick is carried through to the steel work isee Fig. 4i. Fig. 5--Oil or Gas-fired Straight Lise Billet Heating Furnace Insulation. Superex Blocks with Steel Casing on Existing Furnace Johns-\Usville Service to the Iron *nd Steel Industry CB*NT- SUK*tX INSULATION FIREBRICK BONDED WITH N**$ REFRACTORY CEHENT- RED BRICK-----------1 SIDE ELEVATION 3Q{= DOOR SErO-CCL C-J CONCRETE. '-----fmEBRKK SIDE WALL DETAIL Fig. 6--Oil or Gas-fired Straight Lise Billet Heating Furnace. Superex Blocks and Cement Finish on Existing Furnaces f-lRsvCts. v\I) Pkooi Cl k Hvs Mv.S' Billet Furnace Hearths This recommendation is intended l'<>r ' in or more of solid lire brick hearths resting on a fill, or lor ' in. or more oi solid lire brick doors of Hues underneath hearths I hoe portions are insulated with Sil-O-Cel C-* (ioncrete at least 4 in. thick, made by mixing Nil-O-tJel (i-i and portland cement in the proportion of four part' of (!-* to one part ol portland cement i'v volume An e\.e" ol water should be avoided After thorough mixing. the Nl-O-Cel (!-< Concrete is lamped into place 'see l;igs. 4. > and <>l. Billet Furnace Roofs Due to varvmg conditions, it is adv is.ible to con sult the nearest Johns- Manx ille otlice lor detinue rec ommendations lor insulating billet heating furnace roots Annealing and Heat-Treating Furnace Insulation Wastage incidental to annealing and normalizing operations ha' been gieallv curtailed in recent vears bv improvement' m lurnace design and methods ol handling the work. Not least among the laciors that .are responsible for decreased rejections are the reali zation ol the importance which insulation plavs m evenly heating all parts of the furnace and it' charge, ami the attempt to abide by logical princi ples ol design in preventing the llow ol heat Irom those portions which tend to remain at lower than mean temperature. Here again are conditions where heat loss alone does not begin to explain the benefit' that result from the proper use of suitable higlitemperature insulation materials A tepical example might be selected in the field ol horizontal 'beet normalizeis >o generally used in prc'eiii-dav practice. Designers ot well-known con tinuous 'heel normalizeis. alter numerous inul' de cided up.-in tile use ol Superex. to lie applied wli.ie possible, m iwu lavei' d lhickiu-" specified m acco; dance with result' o| experiments I lie excellent III. s - f 111 - I Mvlliw-.'l \SM\IISI, ll\ISN \kI 1 s-l - I \ 111) w 11II '!! a >-< : I I ' K i k I )i<ks \l \iu mi Ni-Il-(.||. (.- > ! , 1 si d II 11 is I 111! I. II Johvs-Mawille Service to the Iron wd Steel Indistky insulating qualities of the Superex permitted the use of relatively thin wall sections which decreased bulk iness: and the staggered double layer construction made possible the avoidance of through joints, with corresponding reduction in heat loss. The results, which the designers ascribe in no small measure to the proper use of insulation, in clude superlative deep drawing qualities, fuel costs 'veil below general practice because of heat conserva tion. increased speed, better texture by saving the bottom heat, thorough normalizing through uniform ity of temperature, and standard quality of product. Scratching and the necessity for roller leveling are reduced to a minimum, and there is a marked de crease in the number of seconds, even when operating without waster sheets. ANNEALING AND HEAT-TREATING FURNACE INSULATION RECOMMENDATIONS These recommendations, for either brick or block insulation, are based on operating temperatures ol I 'tut to 2300 deg. F. in the heating chamber. Furnace Walls All exterior brickwork is insulated with Superex block or Sil-O-Cel brick. The thickness of Superex and the thickness and type of Sil-O-Cel brick used will vary with the temperature, type of heating em ployed. and degree of temperature control required. The minimum advisable thickness of insulation is 4 in. of Superex or 4^2 in. of Sil-O-Cel brick. For electrically heated equipment, much heavier insula tion is always necessary to insure economical oper ation. Where operating temperatures are not more than I SOD deg. F.. either Superex or Sil-O-Cel Nat ural Brick are used: at higher temperature' Sil-i >-(.el C-22 Brick or Sil-O-Cel Super Brick should he ii'cd Superex Blocks are furnished 6 in. x 3o in. and are applied in two or more layer.', using broken joint construction, with all joints closely hutted and pointed tip with J-.M No. 302 Cement. Sil-O-Cel brick are furnished in standard lire brick size. 0 in. x 4JA in. x Z'/i in., and are laid in a mortar of the same material as the brick, with the thinnest possible rubbed joints. Suitable openings are provided through the insu lation for doors, burners, etc. Around these open ings the brickwork should be carried through to the outside. Where insulation is applied over the brickwork after the brickwork is in place, a cement finish over Superex Blocks or Sil-O-Cel brick is recommended i >ee Figs. 10. 11 and 12). The insulation is secured in position by lacing it with soft annealed iron wire to cables run through hides in the buck'tavs. or laced to drilled angle clipspot-welded or bolted to the buckstays. All Mipport- [46] Furnaces. Ovens wd Producer Gas Mains ing steel work is left sufficiently exposed to prevent its reaching undue temperatures. Over the insulation, 1'4 in. hexagonal mesh gal vanized wire netting is stretched tightly and fastened securely to the cables. Two 34 in. coats of J-.M No. 302 Cement are applied over the insulation, the first coat being left to dry with a rough surface before the application of the smooth finishing coat. When an exceptionally hard finish is desired. j-M No. 302 Cement may be mixed with portland cement for the second Vj, in. coat, the proportion of portland cement being from to Yi by weight, depending on the degree of hardness required. If a more durable casing is desired, steel plate or Transite. instead of a cement finish, is applied over the insulation and held in place by suitable angles or angle clips, spot-welded or bolted to the buckstays. New furnaces are generally provided with a steel casing in the original design. Furnaces of this type are usually built from the outside in: buckstays and steel casings are first erected: then Superex Blocks or Sil-O-Cel Brick are laid up inside between the lire brick and the casing (see Figs. 13 and 14). In places where arch thrust or other exceptional stress is transmitted to the buckstays. the insulation is omitted and the brickwork carried through to the steel work. tOLTS ------------------i-------------------- OOOtf rSAtJt ------------------------------- ' SECTION cc THROUGH INSULATED (ENLARGED) DOOR PLAN SECTION SH0W/N6 INSULATED WALL A E SECTION BB SIDE ELEVATION Piii. 10--Oil or G\s l nuiki iri.u Awlhimi Plrsvci. Insulation Sli'f.ria Blocks on Pmsiinc Plknacc Johvs-.M\vvili.k Service to the Iron wd Steel Kdlstry U-M iVa/6 RCFRACTOtrr CEMENT SUPEPEX INSULATION STEEL CASING OR CEMENT FINISH J-M NO 450 CEMENT DETAIL SECTION OF INSULATION ON SIDE WALL rLUC~Z r-------------------------- SUPEREX INSULATION FLUE SIDE ELEVATION LONGITUDINAL SECTION B-B T------J-M NO JOE CEMENT FLUE- -- l hi. II -- Puw Di HI D G*M -I IKM> M \M Mil 1 \\ M \l 1 \i. < >\ I S l \*l I \| |M\ \\ \| II VMI I \\\| M.INii O'i v l)i*nK Aki I\\nkim;m M \ni pi Su^'-Cii G? C.n\i hi 11. [4S] I-irv\<:k>. Ovnss \mi Prooi.r.hK G\s Muss Annealing Furnace Roofs The root is insulated over the refractory with Superex Blocks or Sil-O-Cel Brick, the thickness and type of insulation used being governed by the tem perature. method of heating emploved aiul degree of temperature control required. Insulation shoukl not he less than 4 in. of Superex Blocks, or i in. of Sil-O-Cel Brick. The Superex Blocks are applied in one or more la vers with all joints closely hutted Over the insu lation is stretched I '/ in. hexagonal mesh galva nized wire neUine. fastened securely at the edges In means of expansion holts or staples driven in the brickwork, lor a finish, two !; in. coats of J-M Nii IU2 Cement are then applied, the first coat being left to ilry with a rough 'iirlace belore the applica tion oi the second: the second coat troweled to a smooth linish i-ee l ies. It). II. 12 and 141. Where Sil-O-Cel Brick is used, it i' laid over the surface of the roof with the bricks tightly butted together. The finish consists of a slurry of Sil-t )-Cel .Mortar isee Fig. Ml. SECTION D-D INSULATION OF DOOR INSULATION OF WALL l-u; 12--Ghi-hkh> Avslai.isc I:iks\ck Insliuios Simox Hunks i>\ I:m*ii\i; Iiksui. I 4l> ] Johns-M \nvtlle pervice to the Iron wo Steel Kpl-tky -tire brick SIL-O-CEL NATURAL BRICK------- , , OR SUPEREX BLOCKS \ - - - -V y; i'.i A i-; v : A is a s s m s = = = = ________ SIL-O-CEL C-J CONCRETE- - l-4.' "a ... j. . .4 v. . a. . V,\\ "A \w\ \ \\\\\ s\\ \ A \ ' \V\V3VCTO \\ wXA'vSA A (AU V\\V N OAUUUVU\\\\\u\xUA Pic 13--Insulation Recommendation for Car-type Annealing Furnace. Sil-O-Cel Brick or Superex Blocks in Walls and over Arch, Sil-O-Cel C-3 Concrete in Door and Car. Incorporated in Design Annealing Furnace Hearths This recommendation is intended for use with 5 in. or more of solid fire brick in hearths. 3 in. or more of solid fire brick in floors of flues and for floors of combustion chambers of under-fired furnaces where the floor consists of 5 in. or more of solid fire brick resting on a fill or concrete base. These portions are insulated with Sil-O-Cel C-3 Concrete at least 4 in. thick, made by mixing SilO-Cel C-3 and portland cement in the proportion of four parts of C-3 to one part of portland cement by volume (sue (:igs. 10. II. 12 and 14). An excess ol water should be avoided. After thorough mixing, the Sil-O-Cel C-3 Concrete is tamped into place. Annealing Furnace Car Floors This recommendation is intended for car floors with 3 in. or more of solid fire brick on top of the insulation. Car-floor insulation should consist of 4 in. or more of Sil-O-Cel C-3 Concrete, mixed and ap plied as described under `Hearths." (See Fig. 13). Furnace Door Linings The insulation recommended for doors of indus trial furnaces with a maximum operating tempera ture of IS00 deg. F. consists of Sil-O-Cel C-3 Con crete not less than 4 in. thick. The exact thickness depends on the operating temperature, the method of heating employed and the degree of temperature con trol required. Sil-O-Cel C-3 Concrete door lining are usually from 6 to in. thick. For detail of door lined with Sil-O-Cel C-3 Concrete, see Figs. 10. 12 14. 13 and 16. Where operating temperatures are higher tha; 1800 deg. F., the Sil-O-Cel C-3 Concrete of th [ '0 1 Flrnaces. Ovens and Producer G\s Mains required thickness for proper insulation should be faced with lire brick. For detail of doors insulated with Sil-O-Cel C-3 Concrete and faced with fire brick, see Figs. 4, 3 and 6. Method of Lining--In doors of a greater area than four square feet, reinforcement should be pro vided. This is best accomplished in cast iron doors by installing rods or long holts projecting from the STEEL CASINO ------SUPERSX BLOCKS OP SIL-O-CEL BRICK ------------POOP ERANf iSSSShF 1--SA.-0-CEL C-3 CONCRETE SECTION A-A u-B SIDE ELEVATION SECTION D-D INSULATION or OOO* --rmeamcK some* with >>***/ *crSAcfo*r cincnt ____SUNgNCT SLOCNS rfi&t&k Pic. 14--Oil or Gas-i-ired. In-and-Out Type Annealing Furnace Insulation. Sltdrex Block on Walls and Roof. Sil-O-Cf.l C-3 Concrete in Door and Base, Provided in tiil Oricinal Design Joh\s-M wvn.i.t N-K\ic.t 10 i Mt Ikon, imi Steel Industry SECTION B B Pic. 15--Industrial Furnace Door (Max Temp. 1800 dec. F.) Insulated with Sil-O-Cel C-J Concrete A FRONT ELEVATION OF DOOR SHOWING STEEL FRAMING SECT/ON AT A Fic l(>--Channel-frame Furnace Door (Max Temi* 1800 dec. F.) Insuiatfd with Sii.-O-Cm. C-5 Concrete fVI |i K\ ',i I - I >' I \ ~ \\|l Pm i|U (.1 H ( V' \l 'I '' isii' .lilil .!i"! I.i.s mill t.'i 1 < i-11^ ! t ! l I :'.i ' -sin hi I v i eMcml mill j'.iu vi.iv lliimi^h ihe limni;. .i- >lu ii' n in I la. I v In channel inm iranie si.mi', icmini cement i' ac^nnn'Ii'lisJ I'' iii'i.ilini^ n si' m i'nii' piinectmii min I hi. lining imm liu- m.ii' tnp an.I hnttnm ni unmetal ilmir I:.mii- pl.ni.si mi.i"a' Iviwan liu- iniur iiiul mi i it 'iiri-is-'i1 i'l I it'' ilm 'f In i lit' i \ pc iln. >r iisMitinn.il icinini'Cemeni m.iv i\ prnwslcsl in nma I"iiclIici iIk- mill' hi 1 In.- piiiii'ilmil; nul' nr hull' hi I1U.MI1' nl 'llll.lhll- " III- I\i I-1". 1(11 In the ills.- nl either l\pe nl linnr. ill.- .ipjills.il.fill nl Sil-( >-(xl (>< (.niicrcie i' liu- '.inu- I hi' (am- crele i' made In mium; (!-* mnl pnril.iinl cement in lhe prnpnrtion nl Imir p.irt' nl (.-< in nile p.irt nl Portland lenient In \nlnme I he (!-i i' lii't '.ilu- raled "ilh wilier .m.l .illnwe.l In 'Imul n'erni^hl Pnril.mJ cement is linn added mul iiu\eil ihiirnnehl' uilh llie (i-f ll nece".ii\. .iilililinn:il wilier i> .ul.leJ mul "ell mi\eil. care hcina taken In iimiuI mi e\ce" ni ".Her. I he ilnnr i> laid linri/nni.ilK upnn .i lint 'itriace mnl the C.-i (aincrele. alter thnriiu.nh niivin.i:. rammed min place with a hea\ \ nuT.il l.mi|ier. I he tup mrlace n then lini'hetl 'iiinnih aiul entered "ilh a damp cloth. "huil >iumld be ke-pl wel inr approcimatel' 4S hour' < >n doors nl liirnaccs opcraim.a ai temperatures higher than 1 SOCi di-ji. |- , lire- brick are tiuhilx bmuleil mnl w edited in place hut the (!-< Concrete. I it. |N--l'i-l I 111 i mi \ "i ii ;\i. I i k\ v i I ' - I i 111 ii " n ii Si i -i 1-( a i. I'..... ... \\ i ik 1. 'ii ' inn" I Ii i Simi. V'lii'iiis hi- iiii", |ouss-M w\:i.Lt >i kmck iii mi Iko\ \\I) Mill Khimki Pig |0--Kltiim-k Nor.mal.i/img Plrskce Ksllatios In; 20--SiMii.L C\k Tvi-i; A\\i him, I i km ml CjlSTkll.il l:\lil\KCKI\l'. Co.. PlTT'IU KOII. I'v [ 54] I li. 21 --(j>\ II \l Ml > Hll.\ \SM IIIM, I I IMil CikoKCL .1 llu.W Cn. I'iiIMIIKmII. I'v Furnaces. Ovens \nd Producer Gas Mains Fig. 22--Large Electric Annealing Furnace. Powered with 3000 Kw. Heating Capacity, 15 Toss per Hour. Built by the Electric Furnace Co., Salem, Ohio. For Insulation Used, See Pace 57 Supers* -J/I-O-Cel C-ZZ Brick 5ii- O-Ce/ C-3 Concrete I Lj//t O-Ce/ C-ZZBack --5uperex Fic. 23-- SwiNDtlL Ni'KMvU/ing Firnace Insilation [ 55 ] ItillN. --M vna 11 i i ''i v\ ;> * ic :!it lko\ wn v -I ivU'lNY Z/-C Cet HafvnpiI I----------- ~--~I Ht.t\\ <lui\ nirn.u.-". *u*icm.| .uni 'unit I v ( Iih'.ii;-' lirttlik s*lt.Ut ( > . I l*n. .ic - 111 !nut hril rrt i|ht .1 ivv ,..i life iiini.m. ami util lv Iknvtr I'm 1 l.i> (o, I Jem it. ' I ..i v > > i c.t- iim I i in n.u v . M, tii.-.t .1 in *nl 11 my u*i.l l>i Kt Hi* Hi.iI lit iiltie l H I .1 It I .1 I Il'lll I III tl It. t It *lt l" ' ' nml IuiiMit*. 3 '3ilO Cel N a tu ra l O nck i .<r '|.i .min.ilme imn m .i> *ieniil .tiitl liiuli l.t \| iln VI ie Ml*llll-.t|-.l!* tllMltllli; lilt II nit i h* -1 ni*nl.itinc \ IQ'Sil-O'Cel natural Buck. I i >1 ; -I. .ion >1 ;iii.I l.tiill lit M.niiii.it.ninne It.. i * lc* 2-i -- III M-IHI VMM. I IKMth i\M | \ I I I) Willi J*M \I \ 1 | Ml \I.S [ ;6 1 ; 'C'+c?0'3>/-0-C~' S-rrr: I lK^XCLS (\fc\s VVI> P|>!U :'.H' < i\S M\IS - IQ'^ifOC.W .VMural Br-ict 'li:-r'nic|j iiMtl:itiii ra'<>mnicinlril ly *rtieral Flecrric < in thi> electric l'\ tjc mrn.tcc. Electric Kx-t>j>c iurnr.ee De*nrneJ anil ImiiIi l\ American Electric Furnace (mi*an>. lio>t--ii. Ma*s. J L= B.=J i fi ir L1r=== mn==-a2i tJi j. L= m =i! } |r l!i==jihi_i ==aii 3; 'rYsys%\K///.\ ' 'mmm. 1& Ti\> Ijne* <*i electric lie.'it i real hut mrnnce> m.ule h* I.eeU \ Nortluni'. I'hihIInI >le11l1n.1h1 1i1.1iC. >linunic their mcth-'il Sif-O-Ce! NaturalBrick- Sil-O-Csl j C-22 Brickv is V V9JWB* H I .ante Klectric luttr Furnace I .inline \ l a'-.iiu 1J II i.!c \ F.' it Inch \ *> 11 <irct>. Hmlt l.\ :*.e F.lectnc luin.ue 4 Salem. Oi l-1 t>er Fur. JJ>. Kailu .iv Mau-ri.il> l |j.. Tlcik. htiililcr> iiiC 4 ,. Detroit. l ie 2i--IIht-iki \tim-. "uswets Iwi.uin v\mi 1-M Mxtihuis |OM\ -- \l WVILI.E SkRVICt TO THE IRON XSD STEEL KdlSTRV Method of insulating Westinghouse Electric & Manufacturing Co. rotary hearth electric iurnace. Duraiunnn heat - treating turuacc. U,'*ncil .111 1 built hv >trmiir. 1 .irU'.e iLmimoiul Co . Cleveland, Ohio. High speed Steel furn.tcc lvsigned hv Industrial (haling Equipment Co.. IVirmt. Walking Inmik umu.icc. ile-*igm*l ami )>uih I" K>an. Scully ( . l*ltil.<U l|-lia. Fig. 26--llEvr-7RF\Ti\G Flknxcls Ksu.vtco with ,|-M Mvrumis Flrwcej Uvfcvs wn Frodlt.lr Gv> Mun> C Cs- C-ffr,c<c ,J O Ce/ Car ami roll furnace. \V S k*ckwcll Company, designers and builders. New York City Furnace Co.. Detroit. Method of insulating mm mrnace as designed by American oas l* uniacc Elizabeth, N ). hearth lurunci, designed .md built '*v McCann* Harrison C*rf-.ratin. Cleveland. Uhi". Insulated with Sd-O-t I t .V Hnck. Sittwrc* Illocks. and S.;'c Magnesia iMocks. Hardening inmate. show me method oi iitMilating used by the Snnace Combust ion In, mrnace designers and builders. at Toledo. Ohm Furnace di signed and limit by Ilcvi Durv Kb-ctrrc Tic. 27--Hi \T-m\iiNG Firwcis Kslutid wiiii J-.M Munmi Mihv.iui.ee, W'n |oh\--M \N\ii ; : NkVIl.l H> fill Ike'. wii Sit 11 Km -inv Mftin* I <i inMtl.it mar ` i* titnl 11* mu Imiv* inrn fr 11 (.tmin nilt l i>v }*..i i.i i.tin 1-n.mii' M.tiiti: turrin.' < *> . K.iltiniorc. M*1. \ in.imi litur ............... l-mlt l* l-iri*. Kmtml ^. l. ivu l;iii'!. .it I.*>u*\ill*- K'l.nm lfij l,r**it:ct* < * . I.**iti*\ ill*-. K^. litMilaUil unli I.* ,, in Sil O-t cl N'.mir;il Hrtik. l.'ii'lnc tmr.i lmu iurr..Ki' l.K l.i|iii;-mfiil h::"uinni; l I'liil.tilf li-iu.i. | '.I. M n nil 11*111111 : *t v 111. .it' i ti i i*i. imj ic*m t ''*1 I ir. Jf*--\ ITKR.'l > I- \ \ Mil I \|. I l\ul. I \l I \l I 11 \\ 11II |-M M M I KIM s [<*>! TlirNACF.S Oae;n> WII HkoDICI.K Cj as Main Sil-O-Cel as a Combination Insulating and Refractory Material I ir, Jw--Itl.tCTKICAl.LY llEATEO TuKNACE. DeSIGNID BY Rv an So. li.y \ Company. Philadelphia. S11.-O-C1.1 C-22 Uku.k. A'/, in. Thick. Is Lsed As Inner Lining in W alls. Car Top. and Arch. Backed L i> with l> in SilO-Cei. Natlrai. Brick Tiie Only Tire-clay Refrac tory Is That Supporting the Ribbon Tlements I u; ill--I'.iectric III at-tri aiing I lrnace (Ip to dh; T.) Lulling Sii-O-Cei. .Materials As Combinaiion Reeractory and Insiiation, Designed and Bviit by Iaiis Li.i.ctric Tlrnace Corp . Bleealo. V Y. While in most cases Sil-O-Cel is useil as an insu lating material behinil fire brick linings, its use as a combination refractory anti insulating material in certain types of equipment has been attenileil with great success. .Sil-O-Cel C-22 Brick ami Sil-O-Cel Super Brick because thev bate been calcinetl at high tempera tures. are semi-refractory anil serve very well with out lire brick protection when not subjected to ero sion anil abrasion. The great advantage of such construction lies not only in excellent insulating qualities but also in niarkeil reduction in heal stored in the furnace lining ami time leqmreil lo reach operating temperature. Sil-O-Cel C-3 Concrete for Monolithic Furnaces and Ovens Core ovens and furnaces operated at moderate temperatures are in many cases now being con structed entirely of Sil-O-Cel C-3 Concrete without fire brick linings. The walls and tops of the core ovens in Tig. 31 are composed of 12 in. of Sil-O-Cel C-3 Concrete and the doors are Sil-O-Cel C-3 Concrete, d m. thick. I see F:ig. 32 also). Ovens of this type can be con structed and operated at very great savings over the ordmarv tipe of masonry construction Due to the insulating properties of Sil-O-Cel C-* Conciele ami the tact that all masonry joints are eliminated. I m l consumption is surprisingly low This construction Ip. '! -- Baiora >ii I mi k Mnsiii ihiii t , a--i iki n O.ki (His- lit II I I N OKI I V 1 'I Nil -t M j I ( M (jiNOEII. IJ IN I IIIlK in W Al I s and I III- Dihrs III Sii-O-Ci l ( !- t Coni km I . " I N I Mil K |oHxS-M VNVILl.f. PEKVIUE Til I HI IRON VNI1 >lhhl IsDLSlR' can be satisfactorily employee! for many types of equipment. Detailed recommendations and specifications for this construction on anv specilic type of equipment "ill be gladly supplied by an experienced J-M engineer upon request. Fie. 32--Japanning Ovens at the Durand Steel Locker Co.. Chicago Heights. Illinois. Built Entirely of Sil-O-Cel C-3 Concrete. 9 in Thick in Walls and Tops Size of Ovens 9 ft. Wide. 22 ft. High. 50 ft. Long Core Oven Insulation TEMPERATURES TO 600 DEG. F. On brick core ovens operating at temperatures up to o<t(_l deg. F. the side walls, roof and dour arc insu lated with 2V; in. thick J-.M 85% Magnesia Insula tion dor temperatures below 4(K) deg. R u>e 2 in thick S?7o Magnesia). Side Walls --The Magnesia blocks, (i in. x 36 in. x 2% in. thick, are firmly attached to % in. thick Transite sheets by J-M Fibrous Adhesive, lorming panels. The blocks are tightly butted and till joints pointed up with J-M No. 302 Cement. These panels are securely fastened to the interior ol the side walls by means of suitable expansion bolts in the brick wall, as shown in Fig. 34. Roof--No. 6 gauge wire fabric, with b in. square niesh. is fastened to the lower flange of the roof I-beams by large, square washers and bolts tapped in cm approximately 2 it. centers along the beam'. The Magnesia blocks arc laced under, and wired to this fabric. All joints are tightly butted and pointed up with J-M No. 302 Cement. Pic 33--ChurluVilo Trvnsite Roof Over J-M Insllvud Coke Ovens I Flks:aCES. (.Hess wp Producer 0 \5 M\ISS Over the insulation. 1,'j in. hexagonal mesh gal vanized wire netting is stretched and wired to the lacing wires. Two % in. coats of J-M No. 302 Ce ment are then applied. The first coat is allowed to dry with a rough surface before the application of the second coat. Door--The door insulation is applied between steel plates, bolted together through the insulation, as shown in Fig. 34. Angles, suitably fastened, pro tect the insulation at the edges. I lie blocks are tiehth hutted and pointed up with J-.M No. 302 Cement. Light angles, riveted to the outside plate, give the door added stiffness. Combustion Chamber-Side walls of the com bustion chamber are insulated with 2 in. of Superex Insulation applied in one layer over the exterior with all joints tightly butted and pointed up with J-M No. 302 Cement. The insulation is protected with at least in. of lire brick. SBCTIONB-B l ie 14--Tvncai Cuke Oven Ksllauos run I cmclkatcki.s to 600 dec. F. Com-i iked K-asd-Out Type [63 1 JoH\"M WVll.I.H M KVICh TO IHt IkO\ \\[> Ml-.I-.L Kl)L--TKV l-io. 3'--Typicvl Gt 0\i\ Insulvtios for Tempf.ratlres to SIX) dtc F. On-Finrn Car-iyi'L [64] IlKXUI-.s \ ^ I* PkOI)LU:R Gvs MvlXS Core Oven Insulation TEMPERATURES TO 800 DEG. F. On brick curt: ovens operating at temperatures up to 8<)0 deg. F.. the side walls. roof and door are insulated with 3 in thick Superex Gombtnaiion I nsulation. Side Walls --The .Superex Combination Insu lation. 3 in. thick, consists of 11 j in. J-M 85% .Magnesia Insulation, applied to the inside of the wall next to the brickwork, and 1% in. of Superex Insulation applied over the .Magnesia. All joints are broken, tightly butted, and pointed up with J-M No. 311) Cement. The blocks. 0 in. x 3h in., are ap plied vertically and held in place by % in. x 2 tn. horizontal band iron on IS in. centers, bolted through the insulation to the brickwork by expan sion bolts on 24 in. centers isee Mg. 33 i. Over the insulation a I !/> in. hexagonal mesh gal vanized wire netting is stretched and fastened se curely to the band iron. Then two coats of J-.M No. 319 Cement are applied to a total thickness of % in. The first coat should be thoroughly dry before appli cation of the second coat. Roof.--On the top of the roof 1/ in. of Superex Insulation, then l'/i in. of J-M 83% Magnesia are applied, using broken joint construction, with all joints tightly butted and pointed up with J-M No. 302 Cement. Then two c m co.it> ot J-M No *02 Cement are applied. The lir>t coal i> left to dry with a rough surtace belore the application ol the second coat. Door--The dixir insulation is applied between sheet steel, bolted together through the insulation, as shown in Fig. 35. Angles, suitably Listened, pro tect the insulation at the edges. Against the outside plate. I'in. of J-.M 85% Magnesia, then 1% jn. of Superex Insulation are applied, using broken joint construction. All joints are tightly butted and pointed up with J-.M No. 319 Cement. Light angles meted to the outside plate give the door added stiffness. Combustion Chamber and Oven Floor -Side walls of combustion chambers and the lloor of the oxen are insulated, as shown in Fig. 35, with 2'1- in. of Superex Insulation applied in one layer, with all joints tightly* butted and pointed up with J-.M No. 319 Cement. The insulation on the combustion chambers should be protected by at least 9 in. of lire brick. The insu lation on the floor should be protected by at least one layer of red brick or paving brick. Insulation in Producer Gas Mains Insulated linings in producer gas mains effect op erating economies entirely apart Irom s.i\ mgs in sen sible heat. By maintaining a high temperature in the gas. the insulation inhibits the condensation of tarry vapors resulting from the breaking down of unstable Indrocarboiis. which subsequently deposit on tilelire brick lining. These vapors, by remaining in sus pension. increase the calorific value of the gas at the furnaces, and. as a corollary effect, the length of lime between shut-downs for burnout is materially in creased. The remarkable economies through heat conserva tion incidental to the proper use ol insulation appear m producer mams as elsewhere. Ileal loss through an uninsulated main lined with 4'.- in ol lire brick with a gas temperature of I4!HI deg. F . approximates 1250 Bin. per square loot per hour. Insulated in accordance with a much-used J-.M standard speci fication. this loss is reduced to <25 Bin. On the basis I ti. *o--Mux If-is.. Is-i i \mi won Sil-0-Ci.l X Ml K vL IfKll i; [65] Johns-.M wmlle Service to the Iron and Steel Industry of heat worth 25 cents per million Btu. and con tinuous operation, the saving corresponds to S2.00 per square foot per year on an outlay of less than 33 cents per square loot lor insulating materials. The take-offs from the producers, the soot catcher, and the mains should always be insulated. Fig. 33 shows typical cross-sections through this class of equipment. Producer gas mains are insulated either when old mains are being re-lined with fire brick or when new mains are being installed. Insulation Recommendations Producer gas mains should be insulated with a minimum of lyi in. of Superex Block or Sil-O-Cel Natural Brick. Block Insulation--Superex Blocks, 2/ in. to 4 in. thick, depending on requirements, are applied in a single layer on the inside of the main next to the steel shell. Superex is furnished in blocks 6 in. x 36 in. or 3 in. x 18 in., curved to fit if necessary, and is applied with all joints tightly butted and pointed up with J-M No. 302 Cement (see Figs. 37 and 38). If desired, the blocks may be stuck to the shell with J-.M Fibrous Adhesive. The fire brick lining is applied over the insulation. Brick Insulation --The brick insulation, de pending on requirements, consists of Sil-O-Cel Nat- Fic. 38--Cross-section of Take-off. Soot-catcher and M ms Issli virus I-lksvchs. Ovfcs* am) Pkodlo.k Cvs M\iv ur.il li rick. 2'J in. or 4'.. in. I luck. iimiishcd in standard lire brick si/.e. P \ 4'j \ 2C in. I he lire brick anil insulation are simultaneously applied to the in>ide of ihe shell. To insure a monolithic con struction oi equal uiMiialing value at evcrv point. .vil-O-Cel Natural Brick are laid with vii-ii-(A| Insulating Mortar, usinu the thinnest possible nibbed joints. This mortar n lurnished with the insulating brick at the rale ol Sit lb per thousand brick *ee lags, lo and i. Refractory Cement Recommendations Heating and Forging Furnaces The brick in walls and roof oi heating furnaces are bonded with J-.W No. *1. 12 or 20 Refractory Cement. No. 31 is a dry cement used in making a bond joint: No. 32 i> a dry cement unexcelled for brick to brick joints: No. 20 is a plastic cement suitable lor either kind oi joint. These cements pay lor themselves several times over in reduced spalling and slag action. J-.M Plastic Tire Brick Material is well adapted for patching. J-.M No. 20 Plastic Refractory Cement is used for bonding brick in the Hues, where it goes a long wav in checking erosion. 1-or those who prefer a dry cement. J-.M No. 26 is equally efficient in making a bond joint. brick lining of a main is laid up with a mint that will prevent the seepage of tar and oilier condensible matter, the insulation will he rendered very inellicient. due to its impregnation hy these substances. All lire brick in the take-offs, mains and dust catch ers is bonded with J-.M No. 2d Plastic Refractory Cement. The brick are laid in a thin mortar and tapped into place. I he exposed brickwork inside the take-offs, mams and dust catchers is protected with a wash coat of J-.M No. 20 Plastic Refractory Cement. Annealing and Heat-Treating Furnaces The brick walls anil arches of these furnaces are bonded wiiii No 31. No 20 or No. 2<v The No 20 is a plastic cement lor bond or brick lo brick minis, lor electric annealing furnaces No. 20 or No. 20 arc generally recommended. Both No. 20 and No. 20 are sulphur free and therefore will not atTect resistor elements. I learths and walls of old furnaces are made to last much longer by a '/ in. plaster-coating of J-.M No. 33 Super-Refractory Cement. This cement is extremely resistant to the cutting action of llames and slag. Before application, incrustations must be removed and glazed or smooth surfaces chipped away and well scarified. The brick in Hues arc bonded with No 26 or No. 20. Producer Gas Mains In this class of equipment, the use of a suitable refractory cement is very essential. Unless the lire bn. >u--\ Pi vii Mni I iksvii i>i mi I\i\miV||i| <!.. Sir l i> vvmi |-M Rimvi u>nv Ci.mim IV--THE POWER PLANT ! AGE J-M Materials is the Power Plant............................................................. 71 Insulation of Brick Settings for Boilers.................................................... B. & \V. Type Boiler--Block Recommendation............................... Stirling Type Boiler--Block Recommendation............................... Springfield Type Boiler--Block Recommendation........................ Insulating Brick Veneer Recommendation.................................... Core Wall Insulation Recommendation.......................................... 71 71 73 7' 7o 77 Water-cooled Boiler Wall Insulation and Casing..................................... 78 Air-cooi.ed Boiler Wall Insulation and Casing.......................................... 81 Waste Meat Boiler Insulation....................................................................... 82 Drum and. Drum-head Insulation................................................................. 83 Boiler Tube Door Lining................................................................................. 83 Fire-box Type Boiler Insulation................................................................... S4 Cast-iron Sectional Boiler Insulation....................... 84 H. R. T. Boiler Insulation ............................................................................. 83 Steam Turbine Insulation ............................................................................. 85 Feed-water Heater Insulation ..................................................................... 86 Pump Cylinder and Chest Insulation.......................................................... 86 Breeching and Duct Insulation..................................................................... 87 Internal Insulation--Superex Blocks ............................................ 87 Internal Insulation--Sil-O-Cel Brick ............................................ 87 External Insulation--Blocks Over Air Space............................. 87.86 External Insulation--Blocks Without Air Space......................... Sl> Stack Lining...................................................................................................... Sil-O-Cel Brick Reco.mmendaiion...................................................... Vitribesios Recommendation .............................................................. lH) 00 01 Pipe Insulation ................................................................................................. 93 Boiler Wall Expansion Joints....................................................................... 95 Refractory Cement Recommendations......................................................... 98 J-M Aertite Boiler Wall Coating................................................................. 90 1 <>o I II The Power Plant OHNS-MANVILLE furnishes a wide varictv of outside the insulation on boiler settings has been at J power plant materials for improving perform tended with great success. Transite furnishes excel ance. increasing capacity and reducing operat lent protection for the insulation, resists mechanical ing costs. Insulation is particularly important in inabrasion, and is not subject to deterioration. It lends suring economical operation of power plant equip attractiveness to the boiler-room, lasts indefinitely, ment. Fuel cost is one of the principal items of ex and requires no painting. pense wherever heat is generated, and the problem of Transite is also furnished in corrugated sheets for fuel conservation is a matter of major consequence. use as roofing and siding. These sheets are adaptable A complete line of insulating materials in all forms lor the construction of housings over coal and ash is available to save heat otherwise dissipated from handling equipment and for similar purposes. boiler settings and drums, economizers, breechings and stacks, turbines, pumps, feed-water heaters, and piping. J-M Asbestos Ebony is a durable, attractive ma terial of high dielectric strength, used for switch boards. controller plates, switch bases, bus-bar sup J-.M Refractory Cements lengthen the life of boiler ports and similar applications. Thick sheets of flat furnaces and lessen maintenance costs by reducing Transite also serve as bus-bar barriers, disconnect spalling, by preventing the entrance of tlame at the switch housings, cell structures, etc. joints, and by decreasing the destructive action of low-fusion ash. The tight sealing of the joints, par ticularly when wash-coating is also employed, inhib its the infiltration of air or the extrusion of furnace A complete line of packings and gaskets for all purposes in and around the power plant is set forth and described in the J-M Packing Catalogue. This catalogue may be had by applying to any Johns- gases. Old settings which are not effectively sealed may be made air-tight by the application of J-.M Aertite Boiler Wall Coating over the exterior surface. Manville office. Among other Johns-Manville materials for the power plant are included Industrial Brake Blocks For expansion joints Johns-Manville furnishes re and Linings; Orangeburg Fibre Conduit for cable- silient. high-temperature materials especially devel wavs: Celite for improving workability of concrete oped for packing these joints in boiler furnaces. J-.M No. 4200 Asbestos Rope. Jelly-Rolls. Roll Fire-Felt. R.\ Fibre, and No. 3'2 Cement are used extensively in this class of work. mixes: Asbestos Membranes and Asphaltic Materials for waterproofing and damp-prooting: Asphaltic Concrete Flooring to prov ide resiliency and to resist wear: and a lull line of Asbestos and Asphalt Roof The use of tint Transite sheets as a casing material ings and Shingles. Insulation of Brick Settings For Boilers The development of insulation suitable lor use on boiler furnaces has been coincident with that of the refractories in connection with which it is used. The furnace setting is simply a container for the com bustion of the fuel, and the more thermally efficient the container, the greater will be the capacity of the furnace and the lower the fuel consumption. The necessity for materials designed to retard heat tlow arose as a corollary to the use of thinner walls of better grade brick, as well as increasing demands fur higher elliciencies. Raw fuel has been steadily increasing in price during recent rears, and modern construction has eliminated the great thickness of brick that formerly tended to cut down heat losses. Both of these factors point directly toward the use of an efficient material to block the flow of heat from combustion chamber and hot gas passes. When it is considered that heat loss from one square foot of bare surface often amounts to a matter of several dollars per year, the proper emphasis begins lo be laid on insulation which will save a major portion of this loss. Johvs-.M vvville Service to the Iros ami Steel Imhstry As an example, if the heat from an uninsulated 241HI deg. F. furnace with IS in. (ire brick walls is worth 40 cents per million Btu.. the dollar equivalent of the heat lo>s amounts to $2.67 per square foot per year. If the walls are insulated with 3 in. of Superex Blocks, this loss is reduced to $1.21. saving SI.40 per square foot per year. In such a case the invest ment represented by the cost of the insulation is repaid by the savings in operating cost long before the end of the first year. Aside from heat conservation, the insulation re duces the temperature gradient through the refrac tories. lowering the temperature differential between the two faces of the fire brick, and thereby lessening internal strains and spalling. The more uniform tem perature throughout the lire brick wall reduce' cracking due to expansion and contraction. Insulation itself, if properly applied over the ex-.terior of the brick, tends to seal cracks in the wall, thereby operating to prevent the infiltration of air. This feature is often of even more importance than the saving of heat and reduction in fuel cost. The capacity and efficiency of a boiler are usually directly dependent upon the operating temperature. With the recent improvements in refractories and the protection against internal stresses afforded to the brickwork by insulation, the effort is continually to carry on at higher and higher temperatures in spite of limitations imposed by the heat-resisting properties of refractories. j-tttrfi utcMnu tauumoK *ojorci"t*T " ij_C SECTION A-A SECTION B-B r( bokk SET urn with jOMS-mutnU ntntCTCKr longitudinal section through center LINE OF SETTING SIDE NALL llG. -Blolk Kslimios RlCO.MMIADATIOS Kir B. & W. Tvi't BiiII.LK Shtisc The Power Pi. wt However, increased steam production per unit of heat does not wait upon the use ot increased temper atures. The saving of the heat, the side flow of heat to the back passes, and the elimination of air infil tration which may be obtained through initiation, have resulted in a very material improvement in economy of boiler operation. There is also the im portant human advantage of cooler boiler-rooms. Insulation (or B. & W. Type Boiler Setting Block Recommendation Furnace and Side Walls--All exterior brick work on the furnace and side walls is insulated with 3 in. thick Superex Combination Insulation, as shown in Fig. 1. The fire brick in the furnace section is assumed to be at least IS in. thick and in the first pass at least 13)4 in. thick. Rear Wall --The exposed brick section in the rear of a B. & W. boiler is seldom in the path of gases containing useful heat and. in these cases, is not insulated. Application of the Insulation -- Superex Combination Insulation 3 in. thick consists of 1)4 in. thick Superex Insulation to be applied next to the brickwork and 1)4 in. thick J-M 83% .Magnesia to be applied over the Superex. These materials are furnished in blocks 6 in. x 36 in. and are applied in broken joint construction, all joints being closely butted anil pointed up with J-M No. 302 Cement. The blocks are applied between the buckstavs and horizontal steel work. It is to be noted that all steel work is left sufficiently exposed to prevent its reach ing undue temperatures. Vertical supporting angles are spot-welded to the corner columns and buckstavs. as shown in Fig. I. Light horizontal angles are used where insulation terminates at top and bottom of walls, at exposed horizontal steel members and where distance between horizontal supporting members exceeds -12 in. The vertical legs are punched with )4 in. holes on ap proximately 12 in. centers, the first hole starting at a point 6 in. from the end of the angle. These angles are spaced on not greater than 42 in. centers. The insulation is secured by lacing it to the angles with 16-gauge annealed iron wire. Transite Finish--Transite sheets in. thick are applied over the insulation. These are clamped in place with steel battens fastened to the angles by means of ',< in. x IJa in. round-head stove bolts, so that the bolt heads bear on the inside face of the angle. Washers are used under all bolt heads anil nuts. After the nuts are set up tight, bolt ends are cut Hush with the top of the nut. All vertical joints are tightly butted and battened with 3 in. wide. rj in. thick batten strips of flat steel. All horizontal joints are battened similarly with 2)4 in. wide.-'j in. thick steel strips. Cement Finish (Alternate) --Over the insu lation is stretched 1)4 in. hexagonal mesh galva nized wire netting, fastened securely to the angles and wires. Two J4 in. coats of J-.M No. 302 Cement are then applied, the first coat being left to dry with a rough surface before the application of the smooth finishing coat. Where an exceptionally hard finish is desired. J-.M No. 302 Cement may be mixed with Portland cement for the second J4 in. coat, the pro portion of portland cement being from )4 to )4 by weight, depending on the degree of hardness required. Suitable openings are cut for doors, burners, etc.. as required. The edges of the insulation at these openings are coated with J-.M No. 20 Plastic Re fractory Cement. Boiler Tops --The boiler tops are insulated over the fire brick with 2)4 in. thick J-.M S5% Magnesia Insulation, which is furnished in blocks 6 in. x 36 in. and applied in a single layer with all joints closely butted and pointed up with J-.M No. 302 Cement. Over the insulation is stretched I) j in. hexagonal mesh galvanized wire netting, which is fastened securely by means of expansion bolts or staples in the brickwork. The cement is applied as described in the foregoing paragraphs. Recommendations for insulating boiler drums and tube doors will be found on subsequent pages. Insulation (or Stirling Type Boiler Setting Block Recommendation Furnace and Side Walls --All exterior brick work on the furnace and side walls of Stirling type boilers, with the exception of that portion to tile rear of rhe bridge wall, is insulated with 3 in. thick Superex Combination Insulation, as shown in Fig. 2. The balance of the side walls, extending from the floor to the top of the boiler in the section to the 173] |011Nj-.M WVILLC >F.RVIC TO THE IROV AM) STEEL KdlSTRV rear of the bridge wall, is insulated win 3 in. thick J-M S3% Magnesia isee Fig. 2>. On the furnace proper the fire brick walls are assumed to be at least IS in. thick. On the other portions where Supercx Combination Insulation is used, the tire brick walls are assumed to be 13r ' in. thick. Rear Walls --All exterior brickwork in this section of the boiler is insulated with in in. thick J-.M 83% Magnesia Insulation. Application of the Insulation --All insula tion 3 in. thick or o\er is applied m two or more kncrs. broken joint construction, with all joints 4%T ^ * fc idsr< ro+r ct*r*r LONGTTUOtNAL SECTION OF BOILER SETTING SECTION A-A FRONT ELEVATION. rme n*cx sct u mrm OCnucTOmr C*f*r j-of ji cr-*f*r -amcic jctree l ~3 Cl<+t aerm^rymr f>*C BAKU sfr t* mn cr*c*r DETAIL HORIZONTAL SECTION THROUGH SIDE hall TOMtstrc---------------- su*te* a*--m*rom rto* -- DETAIL VERTICAL SECTION THROUGH S/OE HALL detail or Expansion jo*nt A0 / AND NO 2 CRVHS Fig. 2--Block |\$li.\tios Recommendation for Stirling Type Boiler Setting The Power Pi.wt closely butted and pointed up with J-M No. 302 Cement. Insulation less than 3 in. thick is similarly applied, but in only one layer. The method of sup porting the insulation in place is the same as that described in the corresponding paragraph for B. & W. boiler settings. J-.M No 3i>2 Cement. The insulation and cement finish are applied as described previously. Recommendations for insulating boiler drums and accessory equipment will be found on subsequent pages. Finish --As a finish over the insulation, either a Transite casing or J-.M No. 302 Cement may he used, as outlined for B. & \Y. boilers. Boiler Tops --Boiler tops are insulated over the fire tile with 3 in. thick Superex Combination Insulation which consists of IJ-a in. thick Superex, followed by in. thick J-.M 83% Magnesia with all joints broken, closely butted and pointed up with Insulation (or Springfield Type Boiler Setting Block Recommendation Side Walls and Rear Walls--On boilers of the Springfield type, where there is no bridge wall, all exterior brickwork on the furnace, side walls and rear wall is insulated with 3 in. thick Superex Insu lation (see Fig. 3). The fire brick walls are assumed to be 22'.2 in. thick. su**er msuLATto* __________ rme [75] ] OWN s- M \N VI ].I.L: SERVICE Til THE I RON \ND StEEI. KdIsTRY Tile ;>uperex Blocks are applied in two 11c in. thick layers, broken joint construction, with all joints closelv butted anil pointed up with J-.M No. 302 Cement. The insulation is secureil in place ns de scribed in the recommendation for B. \ W. type boilers A Transite casing is applied over the Superex. or a cement finish is used, as previously described. Boiler Top --The boiler top is insulated over the refractory with 3 in. thick Superex Combination Insulation, employing broken joint construction with all joints closely butted and pointed up with J-.M No. 302 Cement. A cement finish over wire netting is applied in the usual manner. Recommendations for insulating boiler drums and tube doors will be found in subsequent pages. Insulating Brick Veneer Recommendation Insulating brick can be used as a veneer insulation on the outside of either new or existing settings. The methods employed are described below, it being as sumed that at least 18 in. of fire brick are used in the furnace and first pass. New Settings--On new settings, the outer course of brick consists of 4'/2 in. of Sil-O-Ce! C-22 Brick, as shown in Fig. 4. The insulating brick are laid up with the fire brick. In the combustion zone the C-22 Brick are bonded to the fire brick bv means of a course of C-22 Brick laid as headers ewrv fifth course vertically. In the balance of the selling the bond consists ol C-22 Brick headers even lilth course, but with three stretcher brick between bunds, horizontally, instead ol a solid row- ol lieudei'. Over Sil-O-Cel C-22 Brick no finish is mxe"ary. as the brick themselves offer an attractive and dur able surface. If a positive air seal is desired, how ever. the surface is primed with J-.M Insiilkoie Fnmer and then coated with a C in. lo in. ihickiU's ol Insulkote. This presents a dark blown surlace which may be left unpainted, or, if desiied. alu minum paint may be applied. Existing Settings--Existing sellings an insu lated with 4IT in. of Sil-O-Cel Natural Brick (Fig. s i. Spikes or expansion bolls with wires at tached to their heads, located on 2 It. cenieis driven into the mortar joints of tile hrickwoik. pmvi.le leniforcemenr. file Sil-O-Cel Natural Buck air then laid up tightly against the hrickwoik ami I in. hexagonal mesh galvanized wire net ling i' applied 17b] I hi: Powuk Hi v\t n\cr the insulated surface and fastened by the ('in ject iny tie wires. Two ;4 in. coats of J-M No. 302 Cement are then applied over the inflation, the tirst coat being left to dry with a rough surtace before the application of the smooth finishing coat. J-M No. 302 Cement may be mi\ed with portland cement for the second '^ in coat, the proportion of portland cement being from '.! to 1 j by weight, depending on the degree of hardness required. Where an additional air seal is desired. Aertue may be applied over the cement fin ish or. as an alternate. Insulkote may be substituted for the second coat of No 302 Cement. Sote--For veneer constructions, the mortar fur nished with Sil-O-Cel C-22 Brick and Sil-O-Ce! Nat ural Brick should not be used. For this purpose. J-M No. 20 Plastic Refractory Cement should be thinned down to a creamy consistency and the brick dipped to prov ide a thin rubbed joint. Where Sil-O-Cel C-22 Brick are used and no additional finish is desired, the excess cement may be washed off with water before the cement sets. Core Wall Insulation In core wall insulation construction, insulating brick are built in a> a "core" between the lire brick and an outer wall o| red brick I lie J-M recommen dation lor core wall insulation o re'tricted to water tube boiler' of '(to hp. or less and to return tubular boiler settings (.ore wall construction is also em ployed very successfully on such equipment as heattreating furnaces, malleable annealing ovens, ceramic kilns, etc. For water tube boilers. Sil-O-Cel C-22 Brick are used 4J' in. thick in the furnace and first pass be hind at least I3'j in. of lire brick. On the remainder of the setting Sil-O-Cel Natural Brick are used 4'/j in. thick behind at least l> in. of lire brick. (Figs, rt. 7 and 8). In the furnace and first pass the bond consists of a solid course of tire brick headers and a solid course of red brick headers joined through the insulation course. This bond is formed every fifth course ver tically. In other parts of the setting the bond consists I o'. i>--IIiim. Hmi i k Si i i ivr, I\sliviii> vuiii Sn-(M.u Ukuk is Ouki H mi ij'V-mu imv Iohns-Manville Service to the Ikon wd Steel Industry Fio 7--Core Wall Insulation Recommendation for Boiler Setting (300 Up. or less) Fig. S--Core Wall Insulation Construction in Boiler Furnace Fired with Blast Furnace Gas of two adjacent fire brick headers and two adjacent red brick headers joined through the insulation cour>e. This bond is formed every fifth course verlically. with three insulating brick a> stretchers be tween the bonds, horizontally. (Note: In core wall construction, insulating brick should not be used as bonds.) To eliminate any possibility of heat leakage through joints, the Sil-O-Cel Brick should be laid up in Sil-O-Cel Mortar with the thinnest possible rubbed joints. This mortar is turni'hed at the rate ol Si) |b. per thousand brick. The insulating brick are backed up with an S in. wall of red brick laid in portland cement mortar. Water-Cooled Boiler Wall Insulation and Casing Johns-.Manville engineers have developed methods of insulating and casing water walls which offer max imum efficiency, durability and ease of application. Complete specifications and drawings have been worked out in co-operation with the designers of the walls. Bailey furnace walls, for instance, are insulated with: First, a filler coat of J-.M No. 430 Cement ap plied over the metal work to provide a level surface lor the application of the insulating blocks: then two layers of insulation, either J-.M S3(v Magnesia, or Superex and Magnesia (if the temperatures are above POO deg. F.) are applied. The insulation i' then encased with removable and replaceable panels of Transite. \s in. thick (see Fig. 9). This construc tion permits the changing of a lew blocks, or one or two tubes, without disturbing the insulation any where on the wall except that portion which covers the parts to be changed. It has proved eminently satisfactory on every installation of Bailey furnace walls. Detailed specifications and drawings lor the insu lation and casing of other types of boiler water walls are also available and may be had on applica tion to any Johns-.Manville office. The usual con- [7S] I lit IK IJ1 W I '>1 < "mbin.iimn liiMil.ilion nun ol >u|viv\ .iinl mit l.iwi "I J-M S'r ,\l:n:in>ia i applied mtr :he wiir wall? in broken ii'iir ."M';: .. :."ii \ rennnaHe and leplaceabic panel i_\ pe w.i'iMu mi l.-.mvin . in ;huk. i- applied over iin- nwilaiiun l ie )*' C CO CO OO QO CO CO y1 CO C SECTION ASCO " -O J>_Kji-*7r'.fc9*ZsSze/ZwuSJiS*i ***.TZ".a~ctm ;\z v;s -u\' j<: rsr "c cove* , * J*G\Z-i fLOC'S . r.c . - >f'. o.s.* ;/if v r sr-',.*wf~d,sr~*sVrCr>^e*$."555V5rsr*-*jS&r-r/v-$ *T/ * IT---5-" *s M*c'73**str s-~s /.ji;m-00r/,rKr>nNUtLntstrrsnflfBT^9rrsgnNitTsfr*$ KiLLOIOS Rccom.mlndvtios 'A * :r r-*-'" >v- - J *:*<* * 0> z:.-iz ;*`:'V. {*\jrfsTo.tzss ; y wty -- ' <v .r--jrm-- i FAONT CUCVATION *- L-. Fic. |i>--Tile-fvcld W'ulr-wxlu 1n>il\tion [7y| Johns-M\nvili.e J>tRvtcE iu mt Ikon \m> Sitht Indlstk^ -g'rronsife -Super Ftre-Lett -J-fl N9/0/-3 F///board J-FFscso Cement eefracTorq idol/ o +?--r O-: ---J <;__;I s L?j o^i L_J O'. Tf------------- -I--------1 Clevat/on -gTrans/fe rSuper Fire-felt V-NtP/Ohs fill!board rJ-M A/Q 450 Cement J-lieoll \F/re-fe/tGi75Xef3 usual Method Alternate method Method Of Eaetenino t&ans/te Panels Pic. 1J--Insllviion Recommlnihmon iok \ik-cimud \\ u ls I ill Povv i k Pi w i Air-Cooled Boiler Wall Insulation and Casing Whatever kind of .iir p.i"aee' are provided over tile 'iirlace nl ventilated Killer walk lileir lunctioil is in retain the heal ruuu-riJ by the air luniisli a suitable clearance tor an travel m lh.it .lek-qualc 'eml''Kinu :iK.`tmn i' vti>mbiiit^i with the elimination ol undue Iriciion In" and ii'i't tile infiltration nl .nr which would interrupt liie llow over surlaces to be ciiiiliil Furthermore. the construction should he lireprnni and .ible successfully to withstand abrasion, ordinarv mechanical impact and liidi temperature. A> in tile case of water walls. delinile specifications have been developed by Jolnis-Mam ille lur the inLilaliun and casin" ol various types nl air-cooled walls. I lie constructioii most generally used consists nl removable and replaceable panels composed of outside sheets of Traiisite. in. thick, inside sheets of J-.M No. 101-S Millboard, 'j in. thick, and an intermediate layer of J-.M Super Fire-Felt Sheets I in. thick i Pi". 12). These panels are fabricated as a unit by means of k in. x 21' in. round head stove bolts with standard bolt washers outside and with nut' oil the inside bearing auuiii't . ill \ < in. \ < in square iron washers laid a.uanist the larnace 'iirlace ol the Millboard. ISelund each vertical huckstav. >ui'e: lire-lelt It locks I in. thick, and ol a width ei|ual to that ot tile back ot ltie buck'tuv. are ended with ail ui'ule pu>leciive laver of ' i in. thick \o 11 > I -S Millboard aikl held in place by means ol A in. bolts passim; throui>li bevel washers to the backim; channel of tile buckstay and terminatin'; inside with nuts bearint; upon in. x 3 in. x T m square iron washers laid against the furnace side of tile Millboard. Previous to the erection of the fabricated panels, all hon/.ontal 11-beams over tile air-cooled portion of the wall are filled with J-.M No 4ill llenient from the web to a point level with the top ol the llan.ne. Application of insulation and casing is ordinarily completed prior to the erection of brick furnace walls i Pi". I I). Casin" panels are erected in place over the walls after fabrication is complete, and maintained in [SI ] 1 o! i s -- \l vs v i : >t k\ :< l i" i m I k> i\n Mill Isoi -1kv position h\ 2'j in. x '4 in. horizontal sled battens bolted in till: Imri/imKil I I-beams In means of in. \ I 'in cap screws \\ uli w.i'iu i' \ cr11c.1l 101111- between c.i'inii panels and Kn*;U"!.1 \- are sealed in mt'iiih 11I I ' - in. x 1' _ in x ' . 111 angle' with 'lotted holes inr A in. bull-, cm approxmi.i'.dv IS m. \criic:iI vcnld' I he'c angles ;iic bolted -ecurdv In the channel backing ul tile buckslavs and pressed lirmlv against the Transite panels as the linat operation. All joints between supporting steel work and casing winch iliav be subnet to air leakage -hould i\ 4.:'keled. during erection, with Roll I ire-l elt. - m. :n llllckllC". I his construction combine' adequate iii'i;i.it;ou with high heat resistance linpernieabilitv . durui'ih.tv and a permanently attractive exteiioi suilace I lie removable and replaceable panel' otTer tb.e Inrtlier distinct advantage ol maximum uccc'sibiluv I hispecification meets everv requirement deinaikied o! the ideal casing ior air-cooled boiler walls. Waste Heat Boiler Insulation When tile gases irom open hearths and 'imilar equipment are used in waste heat boilers, heat con servation is particularly important. I11 such cases 11m only should the furnaces and regenerators be insu lated anil sealed against air infiltration, but the en tire Hue svstem and the waste heat boilers them selves must be thoroughly blanketed against heat loss if the system is to operate economically. A dif ference of UK) degrees in the temperature of g.i'cs delivered to the waste heat boilers may determine whether the boilers operate at a los' or pay a worth while return on the investment. Complete insulation, therefore, is an absolute necessity wherever so-called 'waste heat" is utilized. The methods of insulating waste heat boilers are usually the same as those employed in direct-fired boilers. fir, 14--Mniicii) or Issuvrisr. WhmVmriCM OiTs-nrsRTii Waste Heat Boiler I 1,. I---Si i-iiiin C.amhisatios Ism i miik (2 i\ Srmux I', is Mv.m-ih Btisc Isstaliid is Wi-ii. Ill si Khiiik [S2] I 1th Powkk Plwt J-n N- JQZ Cement jm/sh^ Z35 Pic. 16--Method of Kslutinc Drums ssd Drum-Heads Drum and Drum-Head Insulation Exposed drums and drum-heads are insulated with J-.M S5% Magnesia Insulation, which is furnished in blocks 6 in. x 36 in. and applied in one laser with all joints closely butted and pointed up with J-.M No. 302 Cement. The insulation is I',j m. thick ior steam pressures of 25 to 100 lb.; 2 in. thick for pres sures of 100 to 200 lb.; and 2)4 in. thick for pres sures of 200 lb. and over. On the drum-heads the insulation is held in place by suitable cables and lacing wire (see Fig. 16). Over the insulation. I.'J in. hexagonal mesh galvanized wire netting is stretched anti fastened. Two '.i in. coats ot J-.M No. 302 Cement are then applied o\er the insulation, the first coat being left to dry with a rough surface before the application of the smooth finishing coat. Where an exceptionally hard finish is desired. J-M No. 302 Cement may be mixed with Portland cement for the second )4 in. coat, the proportion of Portland cement being from to by weight, depending on the degree of hardness required. Boiler Tube Door Lining Sil-O-Cel C-3 Concrete Lining W here boiler tube doors have not yet been bun:' and can be laid horizontally so that the material can be tamped in place, the insulation consists of Sil-O-Cel C-3 Concrete of such thickness a> to com pletely fill the inner portion of the door. The C-3 Concrete is reinforced by installing bolts projecting from the door face so as to extend part way through the lining (Fig. 17). Sil-O-Cel C-3 Concrete is made by mixing Sil-< >Cel C-3 and portland cement in the proportion of four parts of C-3 to one part of portland cement by [S3] Jonv.x-M \svii i.i. Srmii.h in int. Ihos. \m> >ti i-.i. Kni'im S/L-O-CEL C-3 CONCRETE-` 11 *5b0o0o0o0o0ooooo 'OOOOOOO , FomrnOOOOOOOO:' OOOOOOO DOOOOOOO OOOOOOO DOOOOOOO OOOOOOO OOOOOOO. Fie 17--Met min w- Ksu viim; lenr Doors with Sil-O-Cei. C-3 Comjiltl SUPER FIRE-FELT- ^ OOOOOOO \ 1)0000000 I OOOOOOO i )0000000 'OOOOOOO ' 50000000 OOOOOOO JOOOOOOO i iOOOOOOO , J] 1p)o0o0o00o0o0o0 iOOOOOOO O J-M IOI-S M/LLBOARt I'lG. IS--MfcTIIl D fl I SSL L\TIM. Tl BE DooKS w i r11 Si hr I iki -I 11 I volume. An excess of moisture should he avoided. After thorough mixing, the Sil-O-Cel C-3 Concrete is rammed in place in the door with a -heavy tamper. The top surface should be kept damp for approxi mately 48 hours. Super Fire-Felt Lining When the use of Sil-O-Cel C-3 Concrete is not practical, the tube doors are lined with Super FireFelt Sheets. 2 in. thick, secured in place by means of 1 >i in. x 3 in. x 3 in. plate washers which are fast ened to the door by bolts running through the insu lation and the door i Fig. 18). All joints between sheets and around the edges of outside sheets are sealed with J-.M No. 3Id Cement. The exposed surface of the insulation is covered with H in. J-M No. 101-S Millboard, held in place by means of the plate washer construction described above. Bolts and washers should be provided on approximately 12 x 12 in. centers. Insulation of Fire-Box Type and Cast-Iron Sectional Boilers All exposed metal stir I aces ol fire-box type boilers and cu-t-iron sectional boilers are insulated with J-M S'b Magnesia Insulation of the proper thick ness. defending upon steam pressures see Figs. I1* and 2di. For steam pressures up to 2i lb.. I in. thick Magnesia should he used, lor pressures Hum 2' to 1011 lb. 11 j in., and tor pressures of 100 to 200 lb.. 2 in. The lini'h consists of in. No. '02 Cement, applied in two la>ers. as prevailed) de scribed lor drum insulation on page SF j * m*j*/ lie, J<i--Mitiioo Is-i i viis,, ('-i-Ikm\ SiiO"sm liull I ks I S4| I m: PouhK lJi.\\r 4'/2 S/LO-CEL Brice- Between Fire Bnce And Eed Brtcx yJ-tA ( 85 % Magnesia B/ocxs -Hexagonal Wire netting till 21 -- MtTlIOD Ol lssU.VTING H R. I . BolLfcK Insulation of H.R.T. Boilers and Settings The settings of H.R.T. boilers are ordinarily insu lated in core wall construction with a 4JT in. course of Sil-O-Cel Natural Brick (Fig. 21) between the lire brick and red brick as described on page 77 As alternate constructions, insulating block or buck mat be applied on the outside of the brickwork. The e\po-ed siirlaces ol the boiler shell arc insu- lated with J-M 8^fr Magnesia Blocks of the follow ing thickness: For steam pressures up to 25 lb.. 1 in. thick: tor ptesstire' of 2' to 100 lb.. I'j in., and for pressures ol |0d to 2nd lb 2 in. (Her the insulation I: _ in. hexagonal mesh galvanized wire netting is stretched and two : . in coats of insulating cement applied, as described under drum insulation. Steam Turbine Insulation Steam Temperature--600 deg. F. and Over The iron surfaces of the upper anil lower halves of the high pressure turbine shell, including inlet pipe, bodies of the controlling and throttle valves, flanges between throttle and controlling valves and between the controlling valves and the turbine shell, are insulated with VA in. thick Superex Insulation and I'j in. thick J-M SV' Magnesia, together with a in. J-M No. <02 Cement finish--a total thick ness hI 5'j in. In apphing the insulation, all irregularities are first tilled with J-M No. >2 Cement. Then each laser ol insulating blocks is securely wired in place on the surface ol the shell, using broken joint con struction. closely butting all blocks, and pointing up joints with J-M No <02 Cement. A cement finish is then applied oxer the wire netting in two '/j in. coats, as previously described. Steam Temperature--400 to 600 deg. F. I lie casings ol turbines supplied with steam at these temperatures are insulated with i inches of IS5 | |i>n\>-M ii 11; >hk\icp. ro the Iron: wn >iku Km. sirs J-M '''C Magnesia I>UhjU>. prekrably applied in two Livers with all joint' closely butted and sealed with J-M No. 3()2 Cement and securely wired in place A cement finish is then applied over wire nett ins in two m. coats m the usual manner. Steam Temperature--400 deg. F. and Under 1 lie casings of turbines supplied with steam at temperatures from 30U to -100 deg. F. are insulated w ith 2 in. thick J-M Magnesia Blocks. For tem peratures below 3(10 deg. F.. IK' in. thick J-.M 839c .Magnesia Blocks are applied as previously described, and finished with cement in two K in. coats. Asbestos Blanket Insulation for Turbines The demand tor removable insulation construction which would prm ide quick accessibility to bolt heads of turbine Manges, lilting Manges and valve bonnets, and which would be durable, clean and not damage the surrounding insulation when it was removed, has been responsible lor the development of a highly efficient asbestos blanket insulation. I he lollow in- p.uis (l| tile turbines are insulated with J-M Asbestos Blankets o! the same thickness as the adjacent block insulation: Horizontal Manges between the upper and lower halves ol the turbine 'hells. Throttle valve top bonnets T hrottle valve bottom bonnets. Controlling valve top bonnets. Controlling valve bottom bonnets. Controlling valve strainer bonnets. J-.M Asbestos Blankets are made of pure asbestos cloth in envelope form, filled with brown asbestos fibre and tufted with copper wire at close intervals. The edges and seams are sewed with asbestos cord, using sewed-on monel metal hooks or rings in lieu of holes through the cloth. The blankets are made to suit each individual case. Blankets are applied in two layers of equal thick ness. except when the space allowed for insulation bv the design of the sheet metal cover is less than 3 in., in which case the blanket is made and applied in a single layer: Insulation of Feed-Water Heaters, Pump Cylinders and Chests Feed-Water Heaters The entire exposed surface of the feed-water healer is insulated with J-.M S'C Magnesia Blocks, IK- in. thick, secured in place with suitable cables and wiring, all joints being closely butted and sealed with J-.M No. 302 Cement. Over the insulation is applied wire netting and two coats of cement, as previouslv described. (.See I ig "1. Pump Cylinders and Chests The steam and hot water cylinders and chests of all pumps are lagged with J-.M 85% Magnesia Blocks, 2 in. thick, with all joints tightly butted and sealed with J-.M No. 302 Cement. Over the insula tion. an iron jacket is applied. I he insulation on the chests and cylinder heads should he applied in such a manner that it. together with the iron jacket, may be readily removed and replaced. [ 86 ] I m. Howi H Pi wi Insulation of Breechings and Ducts No niic doubt> ihe advisability ni insulating >moke iliiw breechings and ducts m order in maintain the 'cii'iMe heat of the eus being aimeved Steel duets are proteeted Irom eorro-ion. dralt i' improved. exce"ive room temperature' are avoided, and work men are shieleled from burns on the hot metal. Vi hen economizer' or air preheaters are used the sustained temperature head tnereuses the elleetiveness ol heat recovery. In the following paragraphs are set forth several insulation methoels. which may be adapted to meet any refillirements. Internal Insulation -- Superex Block Temperatures to 1000 deg. F. Breechings anil ducts are lined with 2 in. thick Miperex Blocks laid longitudinally anil bonded to the steel with J-.M bibrous Adhesive. The insulation blocks are held m place by means of two 14-gauge iron tie wires laced over each block and lustened to the inside ot the line as described below: Suitable anchors for the tie wires, such as angle clips with a hole punched in the outstanding leg, small washers or nuts set on edge, are welded to the inside surface ot the flue. These anchors are placed on 12 x IS in. centers on ceiling and 12 x 24 in centers on side walls and have the tie wire' fastened through them. An additional set of 14aauee annealed iron lie win-' lor la'ieiiine the wire niesh to the siirtucvol the block are Listened through the anchor clips. with J-.M l ibroti' Adhi'iie and lurther held in place by lacing wires as described below : Anchor' lor the tie wins i which mav be angle clips with a hole punched in outstanding ieg. or si|tiare vva'hers or nut' on edge i ate spot-vveideil to the inside breeching stirlace. spaced on 12 x IS in. centers on the top and 12 \ 24 in centers on the 'ilies. No clips are necessary on the bottom. As the brick are applied, they are secured m place hv wires, laced through the anchor clips. (See big. 2Vi Over the surface of the brick is stretched Bi-gauge I m. hexagonal mesh galvanized wire netting, se curely fastened to the lacing wires. A finish of Jj in. J-.M No. 319 Cement is then applied in the same manner as described previously lor the Superex lining. External Insulation--Magnesia or Superex Blocks Applied Over Air Space bor temperatures up to 600 deg. b., breechings and ducts are insulated on the outside with 2 in. thick J-.M 83% Magnesia Blocks applied over an air space formed by projecting stiffeners. (tier the blocks. l('-gauge I in. hexagonal tile'll galvanized wire netting is stretched and secured to the clips be means of the tie wires. Over this netting J-.M No Ml> Cement is applied in two coat' to a total I hie Liles' of 1J m. The lirst coat i' worked well into the wire mesh, left rough and allowed to dry thoroughly before the succeeding coat i' applied. I lie finishing coat is troweled to a smooth, tinilorm stirlace. Internal Insulation--Sil-O-Cel Brick Temperatures to 1000 deg. F. Breeching' and duct' ale lined on the ni'ide with 2'.- m. >il-( >-( !el N.iiurul Brick, bonded to the Meel .s. Fill 2 t--Cuxsl KY Fl LE l'Sl Lvri 1) III III Si N HI X III K- VI I III (j Ml s I I ISI'll |uii\ -- M \n\ :i ! N h'\ '.I : 11 : Ml I Ki >N I\sli > I I I Kill - I ki l"ii; J' -- I'jIik i; U-i i \ im\ Aitiiidv \ RiorciiiM: ss The Power Plwt Pur temperature.' out nun deg. P . breechings and ducts are insulated uver an air space with 2 in. thick Superex Blocks instead of .Magnesia Blocks. The air space is formed by applying 6 in. square mesh 6-gauge wire t a hr ic over the stiiTenmg mem bers (Pig. 27 i. On Conner)- llucs the fabric is spotwelded to the \-ribs at suitable intervals. On other llues the fabric is securely laced to stiffening angles. On up-takes or surfaces not provided with project ing stiffeners, the air space is not less than I in. in depth, and formed w ith \ -rib metal lath securely wired in place. The insulating blocks are secured over the fabric with suitable cable fastenings. Over the blocks, 1 /i in. hexagonal mesh galvanized wire netting is stretched tightly and fastened to the cables and lac ing wires. Two fg in. coats of J-M No. 302 Cement are applied over the insulation, the first coat being left to dry with a rough surface before the applica tion of the smooth finishing coat. Where an excep tionally hard finish is desired. J-M No. 302 Cement may be mixed with portland cement for the second pi in. coat, the proportion of portland cement being from l/i to Yi by weight, depending on the degree of hardness required. J-M S5 %Moqoesia OrSuprrex J-M /V 3ce Crrnert _ Fir,. 2S--Issuivnov Betwees Ribs of Connery Flue External Insulation--Magnesia or Superex Blocks Without Air Space For temperatures up to 600 deg. F.. breechings and ducts are insulated with 2 in. thick J-.M Mag nesia Blocks laced directly to the outside surface of the (lues. For temperatures over 600 deg. F.. breechings and ducts are insulated with 2 in. Superex Blocks in place of Magnesia Blocks, and similarly applied. Over the insulation. Ill in. hexagonal medi gal vanized wire netting is stretched and fastened to the cables and lacing wire. A cement finish is then ap plied in two !'l in. coats, as previously described. Note -- On Connery llues the insulation blocks are applied only between the V-ribs and secured with J-.M Fibrous Adhesive. The V-ribs are lett ex posed. as shown in Fig. 28. Fie. 27--Enters vl Insli.vtion he Chwiry Fiu. Applied Over Aik SrveE Magnesia or Superex Blocks Over Air Space Where Stiffening Angles Are More than 4 Feet Between Centers For temperatures up to 600 deg. F.. breechings and ducts are insulated on the outside with 2 in. thick J-.M Sf'/l- Magnesia Blocks, applied over an air space formed bv \ -rib lath, with I in. ribs For temperatures over 600 deg. F.. breechings and [89] |oiin-\I anvii 11. 't-HMiT io (UK Ikon \m> >im i Imx-ho jrc insulated un the outside with 2 in. thick Superex Blocks, applied uver tile air space formed hr \ -rib lath with I in. ribs. The V-rib lath is secnrelv wired in place on the surlacc ol the line, and the Mock jii'uLuk>n i> men securely wued i. :;k laih. All joinare ciosely butted aiul sealed with J-.M No. 302 Cement. A cement linish i> then applied in the usual manner ' see I tii- 2l) > Fic. 29--Smoke Floe and Ip-Take Insolation with Stiffeners more Than 4 ft Apart Stack Lining Sil-O-Cel Brick Lining During recent years many steel stacks have been lined with Sil-O-Cel Brick with very satisfactory results. In industrial plants stacks are lined to prevent corrosion of the steel, increase draft and improve the operation of the equipment. In ollice buildings and hotels they are lined for the aslditional purposes of reducing fire hazard and keeping rooms adjacent to the stack shaft from becoming too warm. Stacks are usually lined with 2\\ in. of Sil-O-Cel Natural Brick, although in some cases Sil-O-Cel C-22 Brick has been used, as shown in Fig. 31. Prior to application of the insulation, circumferential an gles. 1 in. x 2 in. x Js in., are placed in the stack on 37 in. vertical centers, the outstanding leg punched with '.t in. holes on 12 in. centers. Alter the inside surface of the stack is cleaned of all paint or other foreign material, the Sii-t>-tie! Brick aie applied, securely cemented to the stack with J-M Fic. 30--Sm.-O-Cll Natlrai. Brick Siack I inin.; [90] III! iJl 'W I K IJ1 W I ' Adhesive and tint her hvut in .-* :;j.1 i ..icma wires. laced through tile ; :n ;iok' m lilt,- j;rjumIcrc-n11:iI angles. < >\L-r tlu- surface ui the brick is stretched I in hevigoiial mesh galvanized wire netting. 'ecareU labelled i" the lacing wires I wo co.u* >! |-M \n. (lenient are then applied In a (ntal tmckiie" nt _ m the first 'j m. coat hem a let t ti> dry with a lough 'iirtnce belore the application of tile 'month nni'hma coat > see I m *2 i. Vitribestos Lining \ itrihestos Sheets. 2 in thick, are adaptable tor limna stack? at temperatures up to 7(H) deg. I\ The \ itrihestos Sheets are lurmshed 24 in. \ *(> in., curled to fit the radius oi the stack. They are >up- ;> a te.t i:i ' -'.ack .a >o _ m inti .Us nil ! . \ I . in \ ' in m .aia.e rina' meted or N.ltej to tiie 'lack I he'c anale ring' are punched on the oul- staikluia iea with A in. Imie' at 12 in intervals, and the 'heel' aie held :n place b\ 2 in. \ 4 m 12-aauae w.i'iiet' and ' I<> m bent boil' thmuah the holes in I lie ring- wi big \ 11 ; >inl' .lie sealed w it ll J-M No <ll> (.eiiieiit and the anale nnas and all espose?l A.i'Her' and bolt' are coveied and protected w till J- M No {|o ( .eiilellt. At the top ot the 'tack, the \ itrihestos should be sealed against the entrance oi moisture be an angle ring continuously welded to the steel stack, or by suitable sheet lead Hashing. securely fastened tn place. An alternate method ol attaching the Vitribestos sheets is 'how n m l ia. (4. z*5H-0-Ce/ Natural Brick- /"-/e Gouge Galvanized WireNettinq 2"x2"xg"Ong/e5^ spaced On sfCC___ Vertically--3 J-M Fibrous----------OdheSixe Tie Wires Spaced On /2" C-C- 5heef Steel. i'j-NW? 3/9 Cement fie.. ?l--Sn-O-tji ('-J2 ItmcK Siw.i\ I isis,, i "I I IT. tj- s; a | I ' . S., W Mil Sll -* ( II Sill K 11. I'lKII k |oh\>-.M \n\ii.i.i: StKMCL to nit Ikon vni) Sithi Kiiiom rf ... :; Cement F/nuh. Orer C//pj & Jo/ntj , r: If -1 11'.' 1 yy/tr/bej/aj : i| 1 i .1 FI i\ ' ii: 1 1 i11 f Ii|!HfiI ill j Llili - Pu;. 1-1--VriKiBtstos Stack I.imnc, Detui.s (\i.tekn\ti Mmino) Ill) Pi AM K Pi \\ 1 Pipe Insulation Johns-Main ille lurnishes the 11>1 It\\in*; kinds ol insulation m .r /nrm t.1 Hit- inr insulating pipes coin ev mg healed llinJ'". A'lbf'lt >-SptHlLTC I Tiled S;,A Magnesia buperex Superex (.Wmhinaiion Asbestos bire-belt Ban roc Improved Ashestocel Wool Pelt Asbestos Combination Spiral Asbestos Pipe Blankets Ashestocel in roll lorm j r~ Ttrrtoc' *s*csrc3 i.SA-l Yu - Insulating materials especially suited lor use in cold work are also available. The proper sort ol" insulation lor exposed pipes is determined by the character of the demand. Pipes subject to loot traffic may not be treated in the same way as those not exposed to this sort of service. Thicknesses which should be used are computed so the heat which is lost through the insulation is only that portion which may not economically be saved. Standard usages have been evolved which are gen erate applicable, except where there is some special I i*. >'--PnutK Piwi Iso: mu u mi l-.W MuIKHI' Typical cmss ssct/cm of j-m i rsren or uNoeeaecuND ihulaticn 1 ir, ?ii--The J-M Systfm of Ksliated 1\dir*.kmi m> Gisdcit Provides a Pfrmvsent. Liiicifxt vsn LmMiMIlVL Mf.vss i hr Si h-si rfvce CnwllWCL Hi Sti mi vnd Hot Wvilr condition such as necessity lor nnniini/.ing temperalure drop nr conserving unusually expensive heat. Molded pipe sections of .Magnesia Sondes! with asbestos libre have become closelv identified with best insulation practice in tile temperature range which has its upper limit at mill deg. I . M heie the insulation is to be subjected lo rough usage, sections of high grade laminated asbestos felts containing embedded particle' ol spongv resilient mateiiul have been Inund in lv much more durable and 'lightly belief in insulating efficiency I lio kind ol insula tion may be used lor temperatures lo Till) deg b . and is known as Asbeslo-Sponge belled. In the range of temperatures so high that Magnesia or Asbesto-Sponge belled should not be used, molded pipe sections of specially treated slialomaceous silica bonded with asbestos libre have pioved very succe"lul. bins insulation is known as buperex. Sometimes A'be'lo-bpiinge belled i' used Hillside of these sections ol buperex lor mecii.mic.il protection ol the Superex and to increase insulating ol -- ! I \Joii-v \l w\ii i 'M-Kur.h i" mi: ko \\t>>m.i-.i ism-iKv erliciencv. Magnesia t also <<iten i.-eJ a> an <mt>kie layer where ihe insulation o not >ublect to abrasion, because it is a little more economical in first cost and is a slightly better insulator than Superex These combinations oi Superex and Ashe-to-Sponge Felled or S^r Magnesia are known a' buperex Combina tion Insulation. Generally speaking. b;'^ .Magnesia. AmY'S.Sponge Felted, or buperex. wiJJ sohe an\ insulation problem on heated pipes winch ordinarily arises, but other materials are available and treuaciitly may be used to advantage Complete intormation on the application of these materials is available at anv Johns-Manville ollice. Pipe Insulation Recommendations FOR TEMPERATURES TO 600 DEG. F. All pipes, fittings and flanges at temperatures be low Mil) deg. I-., except small screwed fittings which are insulated with J-.M No 302 Cement, should be insulated with J-.M SiC Magnesia, or. if subjected to excessive v ibration nr abuse, with .Vbesto-Sponge Felted sectional pipe insulation, to the thicknesses given in the tables below. Asbesto-Sponge Felted pipe insulation may be used, where service conditions warrant, up to 700 deg. F. J-M 859c Magnesia Insulation Thickness of insulation Steam pressure or condition Temperature Pipes larger than 4" Pipes 2" to 4" Pipes smaller than 2" Hot W arcr 0 to 25 lbs.. . 25 to I an lb... 100 to 200 !b Low Superheat ''tiprrhiTtt 212' to 2t>7=F 2o7 = to 558 F 55Yto3X8' F JSS' to 500s F Sun to nan -1\ Std. Std. I T" Dbl Std Std Std. Std. 1 T" 1)1.1. >t.l Std. Std. Std. Std l.T" Asbesto-Sponge Felted Insulation Steam pressure or condition Temperature 'Ihicknc" ! msululHin Pipes larger than 4" Pipes in 4" Pipes smaller than 2*' Hot Water......... 0 to 25 lb.......... 212 to 2tv *F 25 to 100 lb. .. . 2n7to}WF 100 to 200 lb. 558 to 388F Low Superheat 588 to 5(XbF Superheat .... 51KI to one F. High Superheat Will in 7(1(1 (' i" i" 1 T" :v A > , '' i" i" i" 1 T" 1" 2 11 V i" i" i" i" IT" V FOR TEMPERATURES ABOVE 600 DEG. F. All pipes and llanges 1J a in. and smaller, at tem peratures above OUU deg. F., are insulated with a single layer of Superex sectional pipe insulation 2 in. thick. Screwed fittings are insulated with J-.M No. 302 Cement. For pipe sizes larger than I'j in., at temperatures above 600 deg. F.. Superex Combina- tion Insulation is used. This con>i>t> of one layer ot Superex next the pipe, over which is applied a sec ond layer of either J-M S'rc .Magnesia or AsbestoSponge Felted, as conditions require. The proper thickness of each layer for the various pipe sizes is given below. I empcracures Pipe sue. inches 1. and 'mailer :. :t. 5'.- ' -i a'. 5 and la rger 4Ki*-70O*f* 700'-K)0*l: Thicknc** oi Supcrcv inches ihicKncsb of I \Nhou>Sp>ruic i Pelted. nr j' Magnesia > inches I I hiekness >l , i Asbesto-Sponge Thickness Pelted. nr 85*, Rupert*. j Magncsiu inches inches 2 i'. IT IT I I ; IT l,T i . Z IT I 1.. : i ii MK)a-t0Q0"F I hickncsb Ct( Superex. inehc* !hiekne> *l Asbesto- Sp*>ngc Pelted. or Magnesia inches IT IT | 94] Tmk Power Pi.wr Pipe insulation Recommendations METHOD OF APPLICATION The insulation i> applied to the pipe with joints tightly butted, and wired to the pipe with 16-gauge annealed iron wire. All Asbesto-Sponge Felted insulation 2 in. and greater in thickne>>. 83^7 .Magnesia 3 in. and greater in thickness, and Superex Combination Insulation should be applied in two layers with both circum ferential and horizontal joints staggered, and each layer securely wired in place. The insulation on bends should be given a thin finishing coat of J-.M No. 302 Cement to present a smooth, even surface. Insulation over flanges is sur faced with y2 in. J-.M No. 302 Cement applied in two lasers, the first coat being left to dry with a rough surface before the application of the smooth finishing coat. All insulation on piping indoors should be fin ished with a jacket of S-oz. canvas, sewed on and. if desired, painted with two coats of lead and oil paint. All insulation on piping outdoors, or exposed to the weather, should be protected with a water proof jacket. J-.M can furnish various types of waterproof insu lation jackets, of which full details and specifications will be gladly furnished on request. Piping located close to the ground or where there is possibility of mechanical injury should be pro tected with a metal jacket. Boiler Wall Expansion Joints The recommendations given below cover the pack ing of expansion joints used in various types of boil ers as a means of preventing failure of boiler setting structures. The major types of expansion joints are shown in Figs. 37 and 38. These are applicable, in a general way, to almost all boiler settings. Expansion joints not shown on these drawings and found in practice lend themselves to the same class and manner of packing as those shown. The location of expansion joints and the class of boiler settings in which they are found are outlined as follows: Water-tube Boilers (Stirling, Heine, Casey Hedges, Connolly, Badenhausen, Kidwell, Ladd, Erie City, etc.) l.otdttOH of Expansion Joint Drtr^-ini: Kilircmci 1. Furnace roof and side walls.............................................................. Fig. 17 Detail A 2. Rear wall and side walls.................................................................... Fig. *7 Detail II 3. Side walls (vertical joints).............................................................. Fig. 17 Detail C 4. Side and end wall.................................................................................. Fig. 37 Detail B 5. Relieving arch .................................................................................... Fig. 37 Detail G 6. Bridge wall .......................................................................................... Fig. 38 7. Combustion arch, side and end walls............................................ Fig. 38 8. Steam drum and brick setting......................................................... Fig. 38 Water-tube Boilers (B & W, Springfield, Edge Moor, Wickes, Erie City, Walsh and Weidner, etc.) 1. Furnace roof and side walls.............................................................. 2. Rear wall and side walls..................................................................... 3. Sidewalls (vertical joints)................................................................ 4. Side and end wall............................................................................... 3. Relieving arch .......................................................... Fig. 37 Fig. 37 Fig. 37 Fig. 37 Fig. 37 DetailA DetailII DetailC Detail13 DetailG [93 1 wmi.i r. Skrvick to thu Iron wn Sti-.i.l Koi>ikv see oeTAn. * w *ce see octal r. see oe tail c jESl^it 4 ^J-**03SiC*t*r -Wf mu detail a snqkkng packnk .v cmpahsbn jc**t eerwce* poor t sae aau. ^aojvct^ SECT/ON A-A see octal a see oca*, c SECTION B-B FRONT ELEVATION tail 8 ShOnpC packing n vePTKJL frrmn JOINT AT CO&C0 mUS. DETAIL D showing paoong bctwccn nowr HCAOe* NUO OfKJN l OPtOf NALL DETAIL e ShOkanq packing 9C T*S 'i mrep ruoe ncaocps Pic. 37--Boiler Wall Expansion: Joint Location's and Dltails [ l><> ] Thu PowtK l-Vwr 6. Water-tube header.......................................................................... Fig. 37 7. Front water-tube header and setting............................................. Fig. 37 5. Rear water-tube header and setting.............................................. Fig. 37 9. Bridge wall .......................................................................................... Fig. 38 10. Combustion arch, side and end wall? .. . . . . Fig. 38 11. Steam drum and brick setting........................................................ Fig. '8 [Retail !: Detail D Detail F Fire-tube Boilers I. Boiler shell and brick settings........................................................ Fig. 38 - Side walls (vertical joints)............................................................ Fig. 37 3. Union of side and end walls........................................................... Fig. 37 4. Combustion or deflection arch andside walls................................. Fig. 38 3. Deflection arch and end walls........................................................ Fig. 38 6. Bridge wall .......................................................................................... Fig. 38 Detail C Detail B SHOWING TYPICAL EXPANSION JOINTS BETWEEN APOt BLOCKS AMO BOTLEB WALL detail or expansion joint between soup opvnako rmcowrcx settpk AiPttrpt f<r ........ sttttt OETAtL SNOWING NETMOO or PACKING BETWEEN STEAU X/ DPON AND BN/CKWALLS SVBUEPGEO ' WATEP OPUMSAMD SBC WALLS APE BACKED SlMHAPir SECTION CC i: 111 !j 51! ii i' 1! V't/y,. ic 38--Lm'ansion Juists ai Sesi'tsuiD \klii. UKiuot Wall and SttAM Drum 197] |OH\s-MVSVM.LK ShKVICE TO IHt IKON VXU .'Mkl-I K'DLSlln All expansion joints in the boiler setting proper or between parts of the boiler and setting should be made so that the joint is twice as great as the max imum amount of expansion taking place between the adjacent expanding members. Expansion joint materials are installed when the boiler setting is being constructed, except in cases where joints are accessible and can be conveniently packed when the setting is complete. All material is firmly packed into the joint so that there are no voids. Expansion Joint Materials All expansion joints in the boiler setting proper or between parts of the boiler and the setting are packed with either J-M No. 4200 Asbestos Rope or J-M Asbestos Jelly-Rolls. The si/e of the expansion joint is the determining factor in choosing between the No. 4200 Asbestos Rope and Jelly-Rolls. J-M No. 4200 Asbestos Rope is used for joints up to I in. in width. When larger diameter packing is required, it should be the standard Asbestos Jelly-Rolls. J-M No. 4200 Asbestos Rope is*made in sizes from x in to I in increasing h\ increments ot , ir. but can be lurnished when necessary as large as 2 in J-M Asbestos Jells-Rolls are made in standard sue of I in.. 11 j in.. I'I- in., l -j in., 2 in.. 2,'_ in.. 3 in. 3! _ m.. and 4 in. diameter. In expansion joints such a> Details D and I big. 37. and the boiler drum-setting expansion join shown in big 38. the Asbestos Jelly-Rolls are packet in J-M RX Asbestos bibre. This fibre is used to lii the interstices between the Jelly-Rolls with a resii ient material. The water-tube headers, as shown i big. 37, Detail E. can be advantageously packet with strips of J-M Asbestos Roll Fire-Felt. Wall expansion joints should have the opening facing into the combustion chamber sealed with J-.' No. 332 Asbestos Cement after the packing is b place. If there is no J-M No. 352 Cement on th job. either J-M No. 302 or No. 400 Asbestos Cemen can be used satisfactorily. Where movement of the expanding members i liable to work the packing out of the joint, the ex pansion joint material is held in place by a sprin steel plate or by other suitable means. Refractory Cement Recommendations for Boilers and Stacks J-.M Refractory Cements lessen maintenance costs in the operation of boiler furnaces and considerably lengthen the life of the setting. The tight sealing of the joints, particularly when wash-coating is also employed, prevents inlillralion of air or extrusion of furnace gases. By presenting the entrance of tlame at the joints, spalling is greatly retarded, and the destructive effects of low-fusion ash are minimized. High quality refractory cements, used properly, pay a high return on the investment in reduced main tenance expense, in longer runs without shut-down for furnace repairs, and in a generally improved per formance of the furnace. plastic cement is wanted for a brick to brick, o rubbed, joint. Direct-Fired Boilers l or bonding fire brick in fire-tube boilers or in furnace walls, bridge walls, or arches of water-tube boilers, J-M No. 31. No. 32, or No. 20 Relractorv Cements may be used with excellent results. No. 31 is used where a dry cement is wanted lor a bond joint; No. 32 where a dry cement is desired for a brick to brick, or rubbed, joint; or No. 20 where a In, t'i--lloiim IAknvu Si.r l> wmt ,|-M Nn l| \M> \V*h<u.vild won J-M No. 32 RtmveiiKV CtMESTS [9Sj The Power Punt The exposed surfaces of the brick in furnace walls, bridge walls and arches should be washcoated with J-.M No. 32 Refractory Cement, thinned and worked into the cracks and pores of the brick. Where a plaster coating is desired on the furnace walls. No. 33 Super Refractory Cement will be most satisfactory. An excellent patching job can be accomplished on the furnace walls with J-M Plastic Fire Brick Material. J-.M No. 26 Refractory Cement is especially adapted to the coating of vertical baffles. Waste Heat Boilers J-.M No. 20 Plastic Refractory Cement used for bonding and wash-coating the entire setting of waste heat boilers will prevent or greatly retard erosion of the brickwork. Stacks M here stacks are lined with lire brick, the lire brick should be bonded and wash-coated with J-.M No. 20 Plastic Refractory Cement. This material is particularly suited to such applications because of its high resistance to acid fumes. J-M Aertite Boiler Wall Coating Aertite Boiler Wall Coating is a tough, rubbery asphaltic-asbestos coating in plastic form for cover ing the outside of boiler walls to prevent the infil tration of cold air into the combustion chamber. Suction in the boiler, caused either by induced or natural stack draft, draws the cold outside air through the cracks. This air leakage impairs com bustion and also reduces the temperature of gases which are used for generating steam. J-.M Aertite Boiler Wall Coating, applied to the outside of the boiler wall, eliminates air infiltration bv providing a coating over the entire boiler setting which remains air-tight because o| its adheMie anil ductile qualities. DO Johns-Manville Insulating Materials ( )l INvMAW 11.1 f Insulation >erv ice prnv ide In the lolioume page* iiu'e materi.f' are hrieiiv J material' for '.ie throughout the entire r.mw ot dc'Crihed (uimt'leii 111 !< 'ini.lt It 111 i' a . .ul.li'ie < >n all temperature' toed in industrial proce"V'. lioin ol the'e pioduct' a' v\el! -i' uet.uuo konnnundnthe extreme sub-zero temperature' toed in the trc;it1-11>n' covering then application. ment tl ml', chemical'. etc . to 1 In>-.- ol kll>l> dee Iand more used in mam modern industrial pl.mi' Ihe temperature limit' given foi ;he various material' icier to ihe actual tempera:..ie to which l;roni ihe lour basic mineral malerial>--asbestos, magnesium carbonate, diatomaceous silica iCelile). and rock wool made irom argillaceous limestone-- Johns-Manville furnishes insulation in ihe lorms ol the material i' subjected Sil-tM.el M:;'er buck lot instance, suitable tor temperature' ol 2'tMI deg I . can be used behind relractone' in lurnaces operating well over fIMIU deg. sectional pipe covering. insulating 'heels, blocks, There is a J-M product lor even heat-insulating bricks and blankets: insulating cements. Idlers and purpose, f ifty year'' experience and the engineering finishes: insulating paper and fells: as well as a light knowledge of the largest insulation organization in weight aggregate used with Portland cement lor the world form the background lor every Johii'- making insulating concrete. M a n v 11 le rccom mendat ion. I h. 1-- \ I OMH lilt IS I*Ki " I ss <*l I.iA'IKI i IliiV. Slliill l\.. till I i n VI M-s >.| Ism I VIM'S IS K \sl VSI) \\ VII I l"< I |nn\f-M w\ii.i. m KVicn no the Ikox vmi bmi. Kiii-im Bricks, Blocks, Sheets, Blankets, Etc. Sil-O-Cel Super Brick Temperatures to 2'0t) Jce / furnaces ol all types Thev are also ii'ed v\ irh>>L:i lire l'rick protection .is .in inner lining in high temper ature lino .mil in electricallv heated and muffle tvpc I u rn.ices. Furnished in standard lire brick >i/e. 11 in \ -T . in. x 2]' m.. and n> No I and No. 1 arch brick. Weight approximately 2] ; lb each. Packed m lihre cartons containing twenty-live 9 in. straight brick, ur an equivalent volume <>i other si/.e' bpeci.il mor tar furnished for laying. Sil-O-Cel Super Rrick is a calcined semi-relractorv type of diatomaceous silica insulating brick de signed for exceptionally se\ere service. They may be used when the insulating brick is subjected to tem peratures behind the refractory as high as 2>(H) deg. F. They are also used without lire brick protec tion for lining electrically heated or muffle type furnaces. Furnished in standard fire brick si/e. 9 in, \ 4'1> in. x 2'2 in., and as No. 1 and No 2 arch brick. Weight approximately 2'4 lb. each. Packed in lihre cartons containing twenty-live l' m. straight brick, or an equivalent volume of oilier sizes. bpeci.il mor tar lumi-hed lor laving. Sil-O-Cel C-22 Brick Temperatures to 2000 Jc? T Sil-O-Cel Natural Brick Temperatures to h'llf) dett.T. Sil-O-Cel Natural Brick are cut from the pure mineral, diatomaceous silica i ('.elitei. They are used where they will be subjected to temperatures as high .is loot) ileg. F Fins type oi bil-O-Cel Brick is the most ellicient insulating brick obtainable and is used lor the insulation of lurnacc' and other healed equip ment in preference to other tvpes ot bil-O-C.el Brick except where severe temperatures are encountered. Furnished in standard lire brick si/.e. 9 in. \ 4'j in. x 2'/j in., and 9 in. x 4_. m \ P4 in.. 9 in. x 4'in. x 2 in.. l* in. \ 4'.. m \ t in.. .o well as No. I and No. 2 arch brick. Weight approximately I Ft lb each. Packed in lihre cartons containing twenty-live l> in. straight brick, or an equivalent volume ol other si/es. Special niorlar limii'hed lor laving. bil-< )-Cel C.-22 Brick is a calcined seim-ieiiuc-. lore type of diatomaceous 'ilica insulating brick lor use where the insulation will be 'iibucied to tem peratures behind tile retractors- a- high as 2UIHI deg F. bil-O-Cel C-22 Brick are used lor insulation m Superex Blocks temperature- to lot It I dee /. bupetex Insulation is a niosi adaptable and highly ellicient material lor insulating boilers lurnaces. etc . where the insulation nui'i ie'i'1 lemperalures Iv- tvveen (itttt deg. F. and loim deg I It is e"ciiliallv t 104] Johns-Mavville Issllatisc Materials a combination of diatomaceous silica and asbestos fibre, bonded together. Asbestos Fire-Felt Sheets and Blocks Temperatures to 1000 deg.F. Asbestos Fire-Felt is similar to Super Fire-Felt, except that it is heavier and has greater mechanical >trength. It is used where insulation is desired which will not fracture or crumble when applied to sur faces that move or vibrate. Furnished in standard sizes 3 in. x 18 in. and 6 in. x 36 in., flat and curved, in thicknesses 1 in. to 4 in. Other sizes furnished on special order. Weight approximately 2 lb. per sq. ft., 1 in. thick. Also furnished in sectional form for pipe insulation. Superex Combination Block Insulation Temperatures to 1600 deg.F. For maximum insulating efficiency, 85% Magnesia or Asbesto-Sponge Felted blocks are often used in combination with Superex. In this construction Superex is used next to the heated surface as a pro tection for the other insulation. Furnished in same sizes as Super Fire-Felt. Weight for l in. thickness approximately 3.3 lb. per sq. ft. Also furnished in sectional form for pipe insulation. Thermo Fire-Felt Sheets Temperatures to 1000 deg. F. Super Fire-Felt Sheets and Blocks Temperatures to 700 deg.F. Super Fire-Felt is composed of asbestos fibre, felted and formed into blocks, sheets and special shapes, to provide a light weight, efficient insulation. It is used where an especially resilient material in relatively large sheets is desirable. Since it is easy to mould Super Fire-Felt into irregular shapes, it is particularly recommended where this character of insulation is required. Furnished standard in sheets 24 in. x 36 in. and blocks 6 in. x 36 in., from /i in. to 4 in. in thick ness; also in special sizes and shapes. Weight fur 1 in. thickness approximately 1.7 lb. per sq. ft. Thermo Fire-Felt is similar to Asbestos Fire-Felt except that it has a cellular asbestos structure com pletely enclosed in the center of the sheet, giving it increased efficiency and resiliency. Furnished in standard sheets 24 in. x 36 in., in thicknesses from \'/> in. to. 3 in. Also furnished in curved sheets or sheets of special size. Weight approx imately V/2 lb. per sq. ft. for the l'c in. thickness. Vitro Fire-Felt Sheets Temperatures to 1000 deg.F. Vitro Fire-Felt is similar in construction to Thermo Fire-Felt with the exception that the em bedded cellular asbestos structure is vitrilied anil therelore produces a more rigid sheet. [ 103 ] Jonss-M wvii.i.t: Si ki ici to tiii Ikox rxn >'tF.i. Ixni'TKv Asbesto-Sponge Felted Sheets and Blocks Temperatures to 700 den. /'. Asbesto-Sponge Felted is the most efficient insu lating material obtainable in sheet and block lurm lor temperatures up to 7fX) deg F. It is built up of laminated asbestos felts, in which are embedded small particles of a spongy cellular material AsbestoSponge Felted sheets and blocks withstand rough Vitro Fire-Felt is furnished in the same sizes as Thermo Fire-Felt. Weight approximately ' lb. per sq. ft. for the I }/> in. thickness. Asbestos Blankets Temperatures to S00 den. T. J-M Asbestos Blankets are made of asbestos cloth tilled with asbestos fibre, and quilted. They are par ticularly adapted for use where frequent removal ol the insulation is necessary, as on steam turbines, flanges, etc. Asbestos Blankets are furnished on special order for single or double layer construction. Also turnished for pipe insulation. usage and can be removed and replaced without in jury. They are flexible and can be made to conform to curved surfaces. Furnished in sheets 24 in. x 36 in., and blocks 6 in. x *6 in., from '/> in. to 4 in. in thickness. W eight ap proximately 3/: lb. per sq. ft. per inch of thickness. Also furnished in sectional form for pipe insulation. 85% Magnesia Blocks Temperatures to 600 dcg.F. Banroc Blanket Insulation Temperatures to 1000 deg. T. Banroc Blanket Insulation is a flexible insulating material composed of rock wool felted between metal fabrics. The fabrics used are 1 in. galvanized wire netting, heavy copper bearing metal lath. \s in. rib lath, and -}j in. rib lath, the type of fabric depending upon the use to which the material is to be put It is used for the insulation of ovens, oil refinery equip ment and lor similar purposes. Furnished in standard sizes 24 in \ '>(> in and 24 in x 4S in., in thicknesses of I in to <> in l'.an he made in special sizes not over 24 111. x 'Xi m J-M 8'cr Magnesia Insulation is well known as one ot the most efficient commercial insulations. Furnished in standard sizes 3 in. x 18 in. and 0 in. x 36 in., flat and curved, from !j in. to 4 in. in thickness. Other sizes furnished on special order. Weight approximately 1.4 lb. per sq. It . per inch ot thickness Also furnished in sectional form for pipe insulation. Vitribestos Sheets Temperatures to 700 deg. /'. Vitribestos 'beets are made lip of vitrified asbesios lelt> previously corrugated to form a cellular structute L sed for lining stacks, building theatre cur tain'. etc Furnished in standard size flat 'heels 3(> in x 'O in and 30 in \ 72 m . and curved sheets 24 in x [ l"f' I |oHSs-M \W ILLK K'LI.MINi. MvI'NIWs It i' laini-'UJ . m. or ;. in illicit, iloni > 11 It. wide, in bales containing 3|| linear leet. ;> Improved Asbestocel Sheets and Blocks / emperatures to 50i) deg. F 3b in., in thicknesses Irum 1 _ in. tu * in Other sizes :an be furnished un special order. Weight approximately 1.8 lb. per sq. It.. I in. thick. Pan-O-Cel Sheets Type A -- Temperatures to 500 deg. F. TvpeR--i mois ture resistant)--Temperatures to 250 deg. F. Pan-O-Cel sheets are made up of finely corru gated asbestos lelts sealed within sheets of asbestos feit. coated with a refractory solution. Pan-O-Cel Improved Asbestocel is made of plain and corru gated asbestos felts, with cross-corrugations at reg ular intervals, built up to the required thickness. W ell adapted for low temperature oven insulation when protected from mechanical injure'. Furnished standard in 4 plies per inch. Sizes 36 in. x 36 in. and 6 in. x 36 in. from in. to 4 in. thick. Weight approximately I lb. per sq. ft.. I in. thick. Can be furnished 6 plies to the inch, known as Fine Corrugated Improved Asbestocel. Weight approxi mately 1.3 lb. per sq. ft.. 1 in. thick. Also furnished in sectional form for pipe insulation. Asbestos Sheet Millboard sheets were developed to pio\ide a icadili .i"cmbled and -elI-supportin" insulating wall construction for low temperature o\ens. Furnished in sheets 3b in. \ 36 in., 3<i in \ 72 in and 3b in. \ 84 in., and in special sizes. Thicknesses I in to 4 in. Standard Hair Felt J-.M Standard I lair Pelt is made from selected cattle hair. Lsed for refrigerator car insulation, anti to present freezing in cold water pipes. Furnished in 3-foot and 6-foot wide rolls m vari ous standard lengths anti in thicknesses from 'a in. to 2 in. Tankinsul I ankni'iil is a hair lelt insulation with a laser of building paper on each side firmly studied in place. J-.M Asbestos Sheet Millboard is recommended for industrial use requiring sheet or board for protec tion against tire. heat, and acid fumes, and is used as a fireproof lining for lloors. partitions, ceilings, and elevator slialts. It is also used in ranges, stoves, gas-grate backs etc. Made in a number of grades oT varying densities and tire-resisting properties. Furnished in standard sheets 4d in. x 4X in. in thicknesses Irom I C in. to I'd in. I l>7 ] John's-M\nvii.le Sekvicf to ihe Ikon \nd Sn.i-.i. Inik'Iki Insulating Board thicknesses **t 5 fd m. and I S m Ihuh are supplied in standard rolls IS in . d4 m and 3f> in. wide and in special widths to order. Asbestos Roll Fire-Felt J-M Insulating Board is made irom felted wood fibres, damp-proofed, and pressed and moulded to insure uniformity of thickness, density and struc ture. Extensively used as a low-temperature indus trial insulating hoard where large size sheets may be erected to advantage. Also used as a wall-board, plaster lath and sheathing. Furnished 1 _ in. and I in. thick. 4 it. wide and in lengths from 0 to Id feet. Also available in 'in.. 1 in. and I'j in. thicknesses in 3-foot widths, and lengths from 6 to Id ft. Plaster lath is furnished IS in. \ 4S in.. in. and I in. thick, with ship-lap edges. Thicknesses greater than ]' in. are made by stapling :j in. boards together. Asbestos Roll Fire-Felt is a soft felt of asbestos fibre that may be folded, bent or wrapped around pipes and heated surfaces. Especially adapted for uses demanding heat resistance and great flexibility. Furnished in thicknesses of 3/32 in., 1/8 in.. 3 10 in. and 1/4 in. in rolls 3 tL-et wide, containing approximately 100 >q. ft. Ceilinite Rigid Roofinsul Rigid Roolinsul is a strong, rigid insulating board, made of felted waterproofed wood fibres. An ideal insulation for any type of roof deck. It is usually overlaid with a J-M Built-lp Roof. Furnished in sheets ' in. \ d ft. \ 4 it Where more than :j in. of insulation is desired, it can be furnished in two or more boards stapled together. Asbestos Paper and Roll Board Ceilmue is made from Asbestos Roll Fire-Felt, reinforced on one side with asbestos cloth. I wd as an inter-lining in steel cars, and lor fireproofing electrical apparatus, etc. Furnished m rolls hi in. wide x 100 ft. long, in 3/32 in.. I/S in.. 3 16 in. and 1/4 in. thicknesses. Rock Cork Sheets and Lagging I I'HiptTiUuri'i 100 deg. /'. J-.M Asbestos Paper and Roll Board are used when a material of minimum thickness is required, principalis as a protection against heat or as a fireretardant. Asbestos Paper is furnished in thicknesses from 0.01 ^ in. to 1 In in. Roll Board is furnished in J-.M Rock Cork F an efficient insulating material lor cold storage construction and refrigerating equip ment. Manufactured from rock wool combined with [ 106 ] Joh\s-M \nvillq K>l'l\tim; MvrhRivi.s .1 walerprout binning ingredient nv >u kiu^i into sheet' Furnished in 'heel* IS in \ '< in., in iliicwnc"c> from I' _ in to 4 in.. and in IS in. x IS in. 'IklI' I in thick >pec;a! size* including lagging can aI'n he lutiii'iied Weignt approximate!.' 1 l' li\ per m|. II. per inch thick J-M Pipe Insulation Materials Superex Pipe Insulation Tempi r,itnrt< t<> I mil) Jn /, Superex Pipe Insulation i> manulactured from the same material as Superex Blocks. Mee page 104. Superex has been used for insulation at high tem peratures in many of the largest power plants built in recent vears where every precaution was taken to insure maximum economy. Pelted Sheets, l or description. page l"<> It has unusual mechanical strength and is used where the insulation may be subjected to severe usage or vibration. Furnished in 3-foot sections in thicknesses Irom the standard, which is approximately I in., to 3 in., to fit any commercial size of pipe. Furnished in standard sections. < tt. long, in thick nesses from I in. to f in., lor pipe sizes 1 _ in. to Id in., inclusive, l or pipe sizes larger than 10 in., it is furnished in segments. 85f f Magnesia Pipe Insulation / fwpcrnliirt-i In oi><> Jcj. /- Superex Combination Pipe Insulation / I'lnperiitums In lt>H0 Tor maximum efficiency. Superex is often used as a first layer against the heated surlace ami covered with an outer layer of Asbesto-Sponge Pelted or Magnesia. Materials are lurnished in standard sizes lor this purpose. Detailed inlormation is avail able on the required thicknesses of each material for various conditions See page l>4 Asbesto-Sponge Felted Pipe Insulation I iiiipii,linn s In Till) Ji ', I- Asbe'io-Sponge Felled Pipe Insulation is manu factured in the same manner as Asbesto-Sponge J-M-Ssfk Magnesia Pipe Insulation has become definitely established as ihe best insulating material lor general use within its temperature range. [ 109] 1 >11 III \ -- \| \ \\! I I I > KillK\ II I III I III Inns \ M) I i II *I burnished 111 Moot sections in Ilu- 11>iliw Illu thicknesses ---.staiioiard. I `in.. J m . 1 _ in.. Double Mandard. and t in lo til pipe 'i/e' up lo ill in. bur oi/fo lareer than M> in. 'eemeiil' .ire supplied Asbestos Fire* Felt Pipe Insulation Tempi'iiititrci to looo (ice / cement iini'h is di'ire.i I :".:'in\i m sections lone m thicknesses oi I in :o 4 in lor pipe 'i/e' 2 in. and lareer Sl> le \: 11 s |o maiie with a 24-e.iuee ealv am iron outer casing to pmuci a walerproot .tiiol u:.priKii jacket. b'peculiv auapted lor use where 'illation must be I rei|uenli\ removed. I urni'heU J-loot section' in tluckiie"<.' ol !'_ in. lo 4 in !, pipe si/es J in. ill vliailleter and lareer. bpecial 'liapi' can bp furnished lor lnsulalni" tlan.ee> and pipe benils. Improved Asbestocel Pipe Insulation 7 emperatures to >00 Jey. h. Improved Asbestocel Pipe Insulation is made m plain and corrugated asbestos felts, with cross-cor rugations at regular intervals, built up to the re quired thickness. Lseil principally on domestic steam and hot water systems. Asbestos hire-belt Pipe Insulation is composed ol asbestos fibre. felled anil moulded into sections. The material is unusually stroii" and particularly adapted lor use where there is considerable vibration. burnished in Moot sections in thicknesses from I in. lo f in. to lit standard pipe sizes. Banroc Pipe Insulation / i niperotart \ to 1000 i/i e / burnished ill thicknesses of 1. f and 4 plies, each ply approximate!) 1 i in. thick Made m Moot sec tions to lit standard pipe si/es Asbestos Combination Spiral Pipe Insulation / t`mpt r,iltiri'\ lo 101)0 e /' Style No. Js io manutactured with woe neltme inside and metal lath outside, and i' used where a J-.M (.uni bin at ion Spiral Pipe Insulation cop'is:' of a layer of Cieilinite JK m. wule by ' i in. thiol-, over which is wrapped a laver of J-.M No K;l,l Asbestos l.isiine Spiral Pipe Insulation t> particiilarlv adapied '> use oil irregular runs ol pipe and wiieie consider.::'., vibration is encountered, .o on uuloinobile evlia pipes aiul on locomotives. | IK) | | OH N -- M \ x ! ILLtl KsUMIVi, McTh.KISl.S Engineers' Insulating Tape t emperatures to UM><) deg.T. into a 'ingle sheet Puriicuiarls adapted to :"sa!a::ng hot atr heater pipes Furnished in roils <7 . in wide, containing approximated 2't> >q ft Wool Felt Pipe Insulation J-.M Engineers' Insulating Tape consists of 1 in. wide Ceilinite and asbestos listing, stitched together (.(own the center with a ' 4 in marginal extension ol the listing tor the purpose of sealing the joints. I sed lor the same purposes as Spiral Pipe Insulation. The thickness is a full J4 in. Furnished in 2'-toot rolls. Asbestos Pipe Blankets Temperatures to S00 deg. /-'. J-.M Asbestos Pipe Blankets are made of asbestos cloth filled with asbestos fibre, and quilted. Particu larly adapted for use on lines where frequent remosal of the insulation is necessary. Furnished on special order in thicknesses ol 11 _ in. to 3 in. and in single or double laser construction. Furnished also in special shapes lor ells, crosses tees and valves. Asbestocel (Roll Form) Temperatures to HW deg. h. J-M Wool Felt is used for insulating hot or cold water pipes where a low-priced material is required. Several different types are supplied for various con ditions. Furnished in 3-foot sections in thicknesses of Vi in., ki in. and I in. Built-Up Brine and Ammonia Insulation J-M Built-up Brine and Ammonia Insulation con sists of a varying number of lasers of hair tell carelulls applied around the pipes and thorough)! sealed svith a waterproof membrane to gise a highlv effi cient insulation for lines cons eying cold lluids. Asbestocel in flexible roll form is made In Listen ing together a plain and a corrugated asbestos leit Standard Hair Felt |-.M Standard I lair Felt is made I mm selected cattle hair l sed lor refrigerator car insulation and to present Iree/mg in cold water pipes Mandard I HI Johns-Mawille Service to the Iron snd Steel Industry Hair Felt is furnished in 3-foot and 6-!'oot wide rolls of various standard lengths in thicknesses from in. to 2 in. Cork Pipe Covering J-M Cork Pipe Covering is manufactured from pure granulated cork, moulded, compressed and baked. Used on pipes conveying cold fluids. Zero Pipe Insulation Anti-Sweat Insulation is built up of layers of in sulating and waterproofing felts. Used to insulate cold water pipes and to prevent condensation. Furnished in 3-foot sections, in thicknesses of J'j in. and K in. solid construction and in I in.. Zero Pipe Insulation is composed of layers of hair felt and wool felt protected inside and outside. Uargelv used on cold water pipes to prevent freezing. Furnished approximately IJ4 in. thick, in 3-t`oot sections for pipe sizes from '/> in. up. Insulating Cements, Concrete, Fillers and Finishes Sil-O-Cel C-3 Temperatures to 2000 Jeg. F. Weight loose. 2S lb. per cu. ft.; packed. 31 lb. per cu. ft Furnished in 100 lb. bags. Sil-O-Cel C-3 is a coarse granular form of cal cined diatomaceous silica. U>cd as supplied for in sulating tops and for filling wall> of heated equip ment operating at unusually high temperatures. Also used in making Sil-O-Cel C-3 Insulating Concrete. Sil-O-Cel C-3 Insulating Concrete Temperatures to IS00 de" F Sil-O-Cel C-3 Insulating Concrete i> made on the job by mixing four parts of Sil-O-Cel C-3 and one JOHNs-.M AN\ILLh I N SL L ATINO MATERIALS of its fibrous nature, it will not silt through cracks. W eight approximately 17 lb. per cu. tt packeJ in place to proper density. Banroc Temperatures to 1000 deg. F. Sil-O-Cel C-3 Concrete Doors on .Malleable Annealing Ovens part portland 'cement, by volume, with sufficient water to form a plastic mixture. C-3 Concrete is over three times as effective as fire brick in preventing heat loss. Used for insulating furnace bases and as a direct refractory in furnace doors, baffles, dampers, etc. Also used for the monolithic construction ol ovens and furnaces operated at moderate tempera tures. as well as for fireproofing structural steel. The concrete weighs approximately 60 lb. per cu. ft. Crushing strength about 1000 lb. per sq. in. Fibro-Cel Temperatures to IS00 deg.F. Fibro-Cel is a mixture of diatomaceous silica and long fibre asbestos. Since it does not settle under vibration or sift through cracks, it is well adapted for use as a filling material on gas generator sets and similar equipment. Furnished in SO lb. bags. Usually packed to a density of IS lb. per cu. ft. Sil-O-Cel Powder and Coarse Grade Temperatures to 1600 deg.F. These materials are pure diatomaceous silica fCelite). milled to different degrees of fineness. Their insulating value is exceptionally high. Used as a filling material where block or brick insulation is not adapted. Coarse Grade is preferred where easy pack ing is desirable. Furnished in 100 lb. bags. Weight, tamped in place. 13 to 17 lb. per cu. ft. for Sil-O-Cel Powder and 22 lb. per cu. ft. for Sil-O-Cel Coarse Grade. Fil-lnsul Temperatures to 1000 deg. /-'. Fil-lnsul is an asbestos filling material used where a resilient, non-settling insulation is desired. Because Banroc frock wool) is an effective insulating ma terial made of pure rock fibre. Used as an insulating filler in ovens, fireless cookers, electric ranges, etc. Furnished in bags of approximately 30 lb. Packed on job to various densities; usually 12 lb. per cu. ft. is sufficient. Insulating Cements J-.M Insulating Cements are well known for their excellent coverage, good finish and insulating prop erties There is a cement for evert- purpose. Asbestos insulating cements are used as a finish o\er insulation and to seal joints. J-.M No. 302 Cement being the one generally employed. Certain types are used for insulating irregular surfaces. J-M No. 450 Cement is usually recommended for this purpose. J-.M No. 319 Cement is semi-refractorv and serves a> a protection over insulation exposed to the erosive action of hot gases. Aertite Boiler Wall Coating Temperatures to 250 deg. F. Aertite is a tough, rubbery asphaltic-asbestos coat ing in plastic form for covering the outside of boiler and furnace walls to prevent air infiltration. Some times used as a weatherproof coating over insulation. For a I 1(> in. coating, 24 io 40 lb. will be re quired per UK) sq. ft., depending upon the nature of ( M3] (oils-- M \\\ll I I. 'IKVIi! ll> III! Iki'S v\|) >|[.r! Kill 'IKl the surface. furnished in 1V '0. I Ml. foil anil '00 IK container?. si| It per Kin ib l-urni'hed in 'O-lh pails, and m I in. till! and 'ini pound drums. Insulkote Fibrous Adhesive J-M fibrous Adhesive i' u-ed lor the adhesion ot sheet, block or brick insulation to tlai or curved surlaces. l;or sticking insulation lo metal surface' approximately ill lb are required per 100 s^ n.. for sticking to brick, concrete, etc.. 7i lb per ItHi m|. It f:urnishevl reads' to use in SO. ISO. f(ii anil 000 lb. containers. Insulkote is a durable, easily applied, weather proof coating for insulated surlaces. Applied in one coat in. thick, it will cover approximately 4' J-M Insulation for Homes As a result of Johns-Manville experience in the application of industrial insulations, some of the most successful materials for the insulation of homes have been developed Complete information on request. J-M System of Underground Pipe Insulation The J-M System of Underground Insulation pro vides a stable, effective and economical means of insulating underground pipes carrying steam or hot water. The efficiency of the Johns-Manville System is at least 90 per cent, which is maintained for an indefinite period. The ui'iilation used is J-M Waterproof Asbestos i'illinu which remains unchanged In the tempera tures encountered and is immune to moisture, rot and rust W hen packed around the pipes, it com plete! v tills the space inside of the protective tile with an elastic porous mass of interlacing fibres. The J-M System of Underground Insulation pro vides insulation and supports for the pipes, enclosure lor the insulation, and complete drainage hy means of drain-tile and broken stone around the conduit Detailed recommendations lo meet particular con ditions will be gladly furnished by any J-M ollicc. J-M Methods of Fireproofing Structural Steel for fireproofing structural steel. Johns-Manville furnishes insulating materials which are designed to meet lire conditions and give superior protection to all members. The insulation prevents the protected steel work from reaching dangerous temperatures lor a sufficient length of time so that lire mav he extin guished hetore major damage has been suffered by the supporting structure. Mild steel becomes materially weakened between SIX) and 1000 deg l:.. which temperatures are lar [ ll-M Joh'ss-.Mwvillf. KsLLVTIM'. MvTERIVLS below those freijuentlv encountered m plan! tires |-nr thi> reason it has been proved hi"hlv advisable to protect supporting steel work, where failure of any member might cau>e disastrous results. Sil-O-Cel C-3 Concrete F-'ircprooling is recom mended to give protection for 0 to ID hour>. A 1 in thickness is designed lor b-hour protection anil a 3 in. thickness for 10-hour protection. Superex Com bination bireprooling >>upere\ .uul MagneMj block insulation) of a thickness approximating in., including cement linish. is designed to provide pro tection for from 4 to b hours, superex. 11 _ in. thick with a C in. cement finish, is used for protection up to 2'j hours. Detailed information regarding methods of fire protection are available at any Johns-Manville oflice. S i klctl'Rai Steel Fireproofed with Sii.-O-Cel C-t CoNCRETE Strlcturvl Steel Firei`ki>>fed wim Sum-rex CllMBIWTIOS Ix-llvlliix 113 VI--OTHER JOHNS.MANVILLE MATERIALS (Building and Construction Materials--Packings--Refrac tory Cements -- Electrical Materials -- Friction Materials) Building and Construction Materials page Acoustical Treatment................................................................................................. 131 Celite for Concrete, Plaster and Mortar................................................... 128 Flooring Materials Industrial Flooring ....................................................................................... 129 Tile Flooring, Type "A"............................................................................ 130 Roofing and Shingles................................................................................................... 123 Transite Asbestos Products Corrugated Transite Sheets .................................................................. 127 Flat Transite Sheets.................................................................................... 127 Transite-Encased Insulating Board................................................... 128 Transite Pipe ...................................................................................................... 128 W. R. Transite .................................................................................................... 128 Underground Pipe Protection ............................................................................... 130 W aterproofing Membranes and Asphalts..................................................... 131 Electrical Materials................................................................................................................... 122 Expansion Joint Materials...................................................................................................... 122 Friction Materials Brake Blocks, Brake Linings and Clutch Facings................................. 121 Packings .................................................................................................................................................. 121 Refractory Cements ................................................................................................................... 119 Textiles (Asbestos) ...................................................................................................................... 120 [ 1171 s \l 11 l.llt \\ Other Johns - Ma nvi lie Materials (Building and Construction Materials-- Packings --Refrac tory Cements -- Electrical Materials -- Friction Materials) Refractory Cements N best furnace practice, refractory cement* are recommends three cements lor general work: I used to bond bricks a* well a> to provide tor irregularities of shape. By bonding with the proper refractory cement, heat losses are cut down by eliminating open joints, the insulation is pro tected from furnace vapors, and infiltrating air is excluded. By preventing heat penetration at brick For a brick-to-hrick. or dipped. |oinr. J-.M No. 32 Refractorv Cement where a dry cement is wanted; J-.M No. 20 Plastic Refractory i thinned i where a plastic cement is wanted. joints, a suitable refractory cement causes reduction For a bond joint (1/8 in. to 3/lb m.): in spalling and makes furnace walls resist higher temperatures. The refractory cement also retards deterioration from slags. J-.M No. 31 Refractory Cement where a dry cement is wanted: J-.M No. 20 Plastic Refractory where a plastic Wash-coated interiors resist erosive action and pre cement is wanted. vent brick disintegration. Repairs made with plastic In meeting conditions where the refractory cement fire brick material are effective and economical. is to come in contact with molten metal, or there are From a complete line of refractory cements, devel other special problems, the advice ol J-.M engineers oped to serve specialized purposes. Johns-Manville is available on request. [ H9] J OUSS-M vxviLLE Service TO THE Irov on Steel KdlsTRV Data on Johns-Manville Refractory Cements 2o Vo 2v> No 2 \o 30 No 31 No 32 No 33 No 34 No PF.UU Character or ba>c Pl.lNtlC Rciitic- tnrv >lllCa AiutmSilicate Plastic Refrac tory Alumi num Silicate AlumiSilicon Carbide Silicate AlumiSilicate Pr.w CC-xcd Kaolin Alumi num Silicate (`hromc iPld<tie Fire linck Pru- Maien.il cc^ed------- -- Alumina Alumi num Silicate Lowest working tempera ture. or low point vitri fication. deg. F. Ti 'XX) on 1850 1450 1250 1000 1000 1200 1 inn Highest working tempera ture. deg. F. Specific gravity 2700 1 05 2o00 1.08 2000 1.80 300(1 1 85 3I<K) 1 7o 3100 1 77 3300 I o> 3400 24 3500 ; 3000 io ; 2 Approx, capacity; lb rcq'd lor setting 1.000 brick with bond joint 500-000 oOC-700 1.00-700 800-000 000-700 * ft 750-850 750-850 ;; Approx, capacity: lb. req d for setting 1.000 brick.' 400-500 with brick-to-brick joint 400-500 400-500 ___ ,oQO-700 Form in which furnished Plastic Dry Plastic Dry Dry Dry Dry Dry Dry Plastic Containers 5. 10. 25,50 100, 250 500.850 lb. cans or drum* 100 lb. bags : 100.250! 485.800! lb. ! drums ' 100 lb. bags 100 lb. bags 100 lb. bags 100 lb. bags 100 lb. bags i 250 and 100 lb. | 500 lb. bags drums Sets hard when air dried. ttFor plaster coating--average Vt" thick. 400 lb. per 100 sq. It. tMedium air set. ttFor patching figure approx. 115-130 lb. per cu. ft. `Use only in brick-tr>-brick joint--not bond joint. ^Quantity of No. 32 cement required for coating varies a great deal depending upon the pnrewity of the brick Based on average conditions, and when ceinent and water are u-ed m equal quantities, i. e . H>0 lb cement and ItH) lb. water. Of) lb ol cement arc required per 1110 sq. It. ol surlaee Asbestos Textiles Crude asbestos rock, crushed, spun into yarn and woven into fabric, forms a soft, flexible textile--a mineral cloth that resists heat and chemicals. The fibrous material can be felted, moulded or com pounded into thousands of useful forms. The fibre itself, available in various grades, has a multitude of uses as a finished product. Asbestos bags are used in collecting dust from hot gases. Asbestos cloth serves as a filtering base in the treatment of chemical solutions. Asbestos cloth ing for fire-fighting has been welcomed by all who face that menace. Fibre, felt, tape and tubing--all have wide industrial use where the remarkable prop erties of asbestos may be utilized. Johns-Manville will be glad to answer inquiries about any of these or allied materials. Fic. 2--Crude Asbestos [ 1^0] Other Johns-M wville Materials Packings The Johns-Manville line of packings has proved its dependability and economy for all types of indus trial service. Sea Ring, an entirely automatic packing for recip rocating rods, has surprisingly long life under severe service. kearsarge Rod packing for steam. Mogul for valve stems. J-M Flax for hydraulic and Centripac for centrifugal service are a lew of the well-known standard materials. Service Sheet for general requirements. Liberty Red Rubber Sheet for service water. Kearsarge Gas kets for boilers, and many others are included. The J-.M line of packings is scientifically designed to satisfy every industrial need. Rod. plunger, valve stem, piston, sheet packing and gaskets for any service--every requirement is met by some J-M product specially designed to serve the purpose. All these packings are described in the J-M pack ing catalogue, sent on request. Fic. 3--Johns-Manville IUs a Packing for Every Requirement Brake Blocks, Brake Linings and Clutch Facings Johns-Manville furnishes rigid and flexible asbes- ity of friction, smooth and quiet operation, and long tos friction materials for brakes and clutches. The rigid class is well known for high strength, uniform- life on >e\ere low-speed work. The llexihle types wear well on light load' with high 'peed', have high iriction. and aie readilv adaptable to all 'i/es ol drums. The rigid tv pe compri'C' |-M \sbesto- Meiallic Iriction Blocks. Moulded A'bestos Linings, and A'bestos Friction l acings The llexihle class includes J-M Woven Asbe'los Brake Linings and (dutch Facings, and J-.M I olded and (a>mprc"cd Asbestos Brake Lining' and (dutch Facings. Ileal endurance, strength and long hie are three distinctive qualities built into Johns-Manville Friction Materials. All the needs of every piece of braking equip ment vet designed are luililleJ bv some l-M pioducl Recommendations covering I it. 4--\ Set of Giant J-M Brake --Ri.ocks DiamiurTit 1 iv. vnd Weight 1IXX) lb. Small Set Is 1 ft. b is. in Divmeier -I,n upplie.ition will gl.ullv be supplied bv Johns-Main ille. JoHVs-M WVILl.h SkKVICL 10 THE Ikuv vv|) Ml-.I.l IvrKsIKY Expansion Joint Materials W here through joints tire provided in brickwork or between brickwork anil steel work in lurnaces anil boiler settings. it i> nece'sarv to install packing which is both resilient anil heat resisting. Johns-.Manvtile has developed products specially sinieil to this pur pose. which are adaptable to even requirement. J-.M No -4X> Asbestos Rope is used in joints up to I in. in width. Where larger packing is required. J-M Asbestos Jelly-Rolls are employed. Openings lacing combustion chambers are sealed with J-.M No. 3'- Asbestos Cement alter the packing is in place. J-M Roll Hre-lelt is better suited lor packing some joint' than is rope or |ell\-Rolls. J-M RX Asbestos l ibre i' licqueiltlv used to till interstices between and around other packing materials. Detail' as to best practice will be lurni'hed lyv Jolui'Manville upon application. Johns-.Manv ille also lurni'iu-' expansion |omi material lor use in building construction and in paving. These materials are designed to provide maximum resilience and long life, bull information oil request. J-M Electrical Materials Asbestos Ebony J-.M Asbestos Ebony is an ideal electrical insula tor. ebony-like in appearance, which is employed for The specific gravity is 2.<>i and the weight 128 lb. per cu. ft. It is lurmshed in two finishes: ` Stand ard." in thicknesses from I S in. to 3/lrt in., is lacquered a deep, lasting black; "Switchboard." in thicknesses from I 4 in. to 4 in., is lacquered the same as Standard finish, but the surface is smoother than Standard. Sheets are furnished 3b x 48 in. from 1/8 in. to 4 in. thick; 42 x 48 in. from I 4 in. to 4 in. thick; and 42 x do in. from I 4 in. to 2 in. thick, or finished panels of any size within these limits. Asbestos Ebony Moulded Asbestos bbonv Moulded i' similar to Asbe'to' I-bony Sheets, except that it is moulded into special bill s--PlMUs OS J-M AsBhSlOS lillUVY IS \ -\\ 1 II Dt-.sir.si-D CosTKiii. Room switchboards, controller plates, switch bases, bus-bar supports, etc. It is purely a mineral product, com posed of asbestos fibre and binding cement, bonded under tremendous pressure, impregnated with a spe cial insulating compound, and capable of enduring severe conditions. Because of us structure, it will withstand shock and vibration, is unaffected Inrapid temperature changes, will not shrink, crack or buckle, and is uniform in texture throughout. I - to i>-- \shitiis l-.husi Mmi iiihi Is Ki m>ii.v buKviii) iv Shecivl Siiwts (>THfcK |OHX'-MXXVII l.E MllhKIll.s shapes. with hole', counterhores. slots or "ri*ncv adesired. Insert- may he included except in eiiaeui panel', l! i' it-ed principally where 'mall panel' are required lor switches. starters, meters, etc Asbestos Ebonv Moulded is strong electricallx and mechanical!) and make' a very presentable appear ance. It "ill nut deteriorate with aye. "ill nut ab-orb mui'ture. and "ill "ith'tanJ succc"tully the action of ordinary luL'uratori acid'. burnished in three lim.'he' No I1*!, sanded and lacquered dull black on all surlaces. No. 202. un sanded and lacquered; Nu. ?(>b unsanded and un lacquered. Panels can be furnished in thicknes'es from 'A in. to IIJ in. and in sizes up to 20 ,\ 2i in. Tubes and rods can also be furnished in length' up to 12 in. with wall or diameter from 'a in. to K> in. niouni' heatei cure', arc ite.'lector.-. etc. Mandard blectroheslos max be used up to l2tH> deg. E xxhere Transite Sheets LI lC, H--(hi-'' \'D llrxTkK luK vBuRVTliRY I;i.xsks. Runners. itc . Mullokd ui J-M l-.rECTKimtsTos conditions involve rapid temperature changes. Electrobestos "X" is harder and stronger and resists temperature changes equally well if below 700 deg. F. it may be used up to 12(H) deg. F. Electrobestos is moulded on order in J-.M factories from samples or drawings furnished. When ordering, information should also be given on the allowable tolerances and the conditions under which the mate rial xvill be used. Niagrite-Asbestoment Cable Fireproofing I f,; 7--PvNHs ny J-M Trwmtp on I M I f> f*.NCl.oNLKh Transite. described on page 127. is the leading fireproof material on the market for use where high dielectric strength is not required. Its mechanical strength has caused it to have wide application as a barrier at all points where an electric arc may pos sibly occur. Long service in the field, severe lire tests, and sudden changes in temperature have proved that it does not become warped, distorted or weakened in service. Electrobestos J-.M Electrobestos is a heat-resistant'moulded ma terial suitable for oxen or heater parts, resistance J-.M Niagrite- X'be'tonient o an inexpensive and easily applied combination o! material' used to lorm a lirepruot. arc-proof protection fur electric cables In the event of a breakdown in a cable, adjacent cables covered with Niagrite-Asbestoment are secure irom the arc. J-.M Niagrite is commercially pure asbestos felted tape, supplied in widths ot I'J in. 2 m. and J in., anil in thicknesses ol J ^2 in.. I S in.. TMO in., anil I A in., and. unless otherwise ordered, in rolls of I' feet. It is lurni'lied with or without reinforcement ol asbestos cloth asbestos listing or jute cloth. J-.M Asbestoment is a chemically neutral powder, packed in 101) lb. bags with complete directions for use The Niagrile is impregnated with a mixture of Asbestoment and water. The Niagrite is then applied spirally to the cable, after which it t> coated with a mortar ot N'hestoment. f ^3 1 \SVII.I ` >tKMU- I" 1IK- iw<>\ \Ml M'-.l. IsDl'IK't \pplts.m..n *.t \-\\ C.i.rru- ii.iteJ 1 r.iMMlc :n >.ixv-Unith k*ni ( nmru;11 *n n l ;irc i, I it. ,J--Jnti \l\iit!\t. Mpikivis \kj \ium smi 1.1 fix tm l\wn i\. Ki jmhi \w m I 124] Other Johns-Manville Materials Orangeburg Fibre Conduit Orangeburg Fibre Conduit is made of wood fibre, impregnated with an insulating and waterproofing preservative. The ends of the conduit are cut to form a I larrington tapered sleeve joint or a mortise and tenon socket joint. The conduit is designed for underground distribu tion of power and telephone cables and signal wires. generator leads, transformer leads, bus-bar coveiv and ducts in lloors and retaining walls. It is particu larly suitable for such installations because of its high insulating qualities, lightness, resistance to cor rosion. freedom from hysteresis. and ease and -peed of installation. Furnished in five-loot lengths, except in the 1 in size, which is turnished in four-toot lengths. Some short lengths are included in everv shipment for convenience. Standard diameters are from I in. to ' in. in y> in. gradients. Larger sizes on special order. Radial bends, S bends, tees, elbows, crosses and junction boxes, suitable for the most complicated installations, can be obtained. Jointing compound for waterproofing joints is also available at a mod erate cost. Other Electrical Supplies Fic. 10--Fibre Conduit Used in Underground Power Distribution--Brooklyn Edison Company Johns-Manville supplies Asbestos Listing in vari ous sizes for wrapping electrical wires, Fibroid and Armaturo Asbestos Paper Tape for winding magnet and armature wires, and friction tapes and splicing compounds to fill every need. Further information on j-M Electrical Materials and their uses is available at any Johns-Manville office. Roofing and Shingles To meet any rooting requirement. Johns-Manville supplies Built-Lp Roots. 1 ransite. Asbestos and Asphalt Shingles. Ready-to-Lay Roofing. Insulated and Rot-Proof Roofs, and Roof Insulation, with all necessary accessory materials. The high quality of these materials, their adaptability to serve particu lar purposes, together with a successful record every where. have made the name Johns-Manville pre eminent wherever roofing is used. Built-Up Roofs J-.M Built-Up Asbestos Roofs are the outcome of several decades of study and experience in producing permanent, fireproof, leakproof, light-weight roofs at moderate cost. They are made of alternating lavers of asphalt-impregnated asbestos felt and J-.M Roofing Asphalt with a smooth top surface of asphalt. Their resistance to lire and the ravages of weather through veais of service without mainte nance. amply justifies the guarantee which accom panies each standard roof as a definite assurance of protection to the owner. The number of alternating layers of impregnated asbestos felt and asphalt de termines the classification of the rool. J-.M Combination Built-Up Roofs are composed of a rag felt base with asbestos linishing felts. \\ hen a top surface of gravel or slag is required. JohnsManville supplies "Type B" roofs, the lelts of which have a rag base. The top surface consists of slag or gravel, embedded in a top coat of J-.M Rooting Asphalt. When a colored roof is desired, a top layer of J-M Split-Sheet Slatekote Roofing is used instead of the usual finishing coat of asphalt and slag or gravel. Proper application is just as important in produc ing a J-M Built-Up Roof as are the materials them selves. For this reason, in every community J-.M Approved Contractors have been selected by Johns- |i 'll \ \1 \'\\ I I I I ''I K\ II. In I Ml I kl's \ SI) >| || | Km I K ) FlC li--JnllsS-.M ASVII I 1 Kiml ISi, M 11IKIM) \ KF Ar>\f T Mil I 1 n IM K) Rmllsi. KiijiikiMISi [ 1-'6 1 Other Johvs-.Masville Materials .Manville as qualifying in roofing experience anil business integrity to carry the J-.M franchise in applying Built-Up Roofs. Ready-to-Lay Roofings In Ready-to-Lay Roofings. Johns-.Manville sup plies both asbestos felts and rag leits with plain or slate-imbedded surfaces. These materials are fur nished in a variety of colors anil weights. They are inexpensive and well suited for use where roll roof ings are adaptable. Asbestos Shingles J-.M Rigid Asbestos Shingles are made of asbestos fibre and portland cement, moulded under tremen dous pressure into rigid, monolithic slabs. They pro vide a permanent, weatherproof, fireproof roof which can be designed to harmonize with any architectural style and color scheme, because of the great variety of sizes, shapes and colors available. Asphalt Shingles J-.M Slatekote Shingles, made of asphalt-saturated rag felt and asphalt, are durable, weather-tight. inexpensive and present an attractive appearance. They are made in a wide variety of solid colors and blends. Transite Roofing For roofing and siding on skeleton steel frame buildings, corrugated Transite sheets provide a dur able. fireproof construction, unaffected by weather and highly resistant to the ordinary acid fumes found in industrial plants. Transite is easily erected and requires no painting or maintenance of any kind. Transite is described below. Insulated Roofs J-.M Rigid Rooftnsul is a strong insulating board made of felted, waterproofed wood fibres. Applied in conjunction with a J-.M Built-Up Roof, it is an ideal insulation for any type of roof deck subjected to ordinary conditions. Where interior humidity is especially high and roof drip must be eliminated, the special patented roof construction known as J-.M Insulated Rot-Proof Roof is recommended. In this construction, cork in sulation is built-up over W. R. Corrugated Transite and the whole protected by a J-.M Built-Up Roof. Transite Asbestos Products J-.M Transite Products are composed of asbestos fibre and portland cement, combined under tremen dous pressure into a homogeneous, dense mass hav ing high strength and great durability. Transite is light grey in color; weighs about 124 lb. per cu. ft.; and can be drilled with twist drills, punched, fastened with nails and screws and sawed with a hand saw. though a portable power saw should be used if much sawing is to be done. Transite is made in a number of different forms for various purposes. Flat Transite Sheets Transite is furnished in flat sheets for use as a casing over insulation on industrial furnaces and boilers; for ceilings, walls, partitions and fire doors in building construction; and as dryer housings, hoods, dampers, baffles, and ducts in various indus trial processes. It is also furnished made up into ventilators, forge jacks, smoke jacks, etc. Transite offers high resistance to acid fumes and atmospheric conditions. It cannot rot or corrode and can safely be used where it will be subjected to tem peratures as high as 800 deg. F. Flat sheets are furnished 36 x 48 in.. 42 x 48 in., and 42 x 96 in., and in thicknesses of ,'/ in. to 4 in. Corrugated Transite Sheets Corrugated Transite sheets are particularly de signed for use as roofing and siding. This materia! has found wide application in industrial plants due to its high resistance to acid fumes and atmospheric [ 127 j JOHNs-W VNVILLE SkRVICE TO THE IRON AND STEEL Koi STRY conditions and because of its strength, permanence and ease of application. As accessories, the material is furnished in the form of ridue rolls. corner rolls, and louvres. Every detail of construction has been thoroughly worked out. and lull intormuiion may be had on application to any Johns-.Manv ille oliice. Corrugated Transite sheets have corrugations with a 4.2 in. pitch and a depth of I'.j in. They are furnished 42 in. wide and in lengths of 4 ft., a ft.. 5' j It.. 6 ft.. 7 ft.. 8 ft., and 8'2- ft. The thickness is approximately 7-16 in. at ridge and valley of cor rugations. and approximately 3/|<i in. on tangent. Weight approximately 4.1 lb. per sq. it. Curved sheets or special cut sheets within the above size limitations can be furnished on special order. W. R. Transite Both Flat and Corrugated Transite sheets are fur nished with a special bituminous impregnation to afford maximum impermeability where the material will be subjected to extreme and sustained moisture or add conditions. W. R. Flat Transite is furnished in sheets 42 x 4S in. and 42 x 96 in. and in thickness of }4 in. Smaller sizes can be furnished on special order. W'. R. Corrugated Transite is furnished in the same sizes and thickness as the standard material. Transite-Encased Insulating Board This material consists of a core of .12 in. or I in. I-M Insulating Board with a 1 k in. sheet of Hat Transite cemented to each side. Used as a combina tion insulation and casing for low temperature ovens and dryers. Furnished in standard size sheets 42 x % in. Transite Pipe Transite Pipe is manufactured by a process which insures a highly uniform quality. It has a dense. Fic. 13--Laying J-M Corrugated Transite Roofing The Cut Corner Obstruction Permits the Nesting ok Corrugations. Makes a Tight Joint, and Results in a Durable vno Attractive Roof close-grained structure, is immune to oxidation, tubercuiation and electrolysis, and highly resistant to chemical action. Transite Pipe has a very smooth interior surface and a high delivery capacity. It is much lighter in weight than corresponding metal pipes, is readily workable, may be cut or tapped, and does not need exterior or interior protection except for extreme conditions. Furnished in five classes as follows: Class S fnot for pressure conditions') is used as soil pipe as well as vent stacks anil Hues carrying gases up to 3IK1 deg I' It is also used tor protectinu electric cables against lire hazard. Furnished in sizes ranging from 2 in. to 40 in. in diameter. Classes A. B. C. anil D are designed lor working pressures of 371 -2. 73. I 30 and 223 |b. per sq. in., respectively, and are used for delivering hot or cold water, gas. brine, and certain process liquors and solutions uniler pressure Classes A and B are fur nished in sizes from 2 in. to 40 in.: Classes C and 0 in sizes from 2 in. to 24 in., and larger on special order. Celite - for Concrete, Plaster and Mortar Celite lor Concrete is a light weight mineral powiler i diatomaceous silica) used in portland cement concrete for increasing the workability of the mix and lor improving uniformity, strength, watertightness and appearance of the final concrete. Used at the rate of 0.2 to 0.6 cu. It. pier bag ol cement. For the average 1:2:4 mix. 0 3 cu ft will give excellent results l:\tended use over a period of vear< has shown that Celite is a positive mechanical means of iii'uiing better concrete under average field conditions, Being practically pure silica, SiO>. it is the most [ l-S ] Other |ohns-M wvtlle Mvtf.kivis permanent element in concrete and dues not aiTect the time of setting Due to decreased labor costs and to the increase in the yield ol concrete when (lelile i' used. it Joes not aJJ to the co't of the concrete per unit o! volume. ('.elite is abo used with eNCelleiU results ill CeUlent anil lime planters ami mortar- matenallv improving the plasticitv anJ working qualities anJ increasing strength. B\ hoklinn the water within the mortar, it allows more time lor the placing ol the brick before the workability of the mortar ha> been lost. Celite mortars have exceptional spreaJ ami "fatness." (Idite is furnished in HH) lb baits. Pic 14--Cti itf. tor Discrete \\ vs Ism i\ Tutst Citvors-fr Pits of the 5t Lmi- G>kf \ Ikh\ Cu. ViKiMTE Cits li i i\ms J-M Flooring Materials J-M Industrial Flooring J-M Industrial Flooring consists of a carefully selected and graded mineral aggregate, bonded with high quality asphalt cement. The materials used are resistant to the action of acids, brines and other alkalies. Extensive experience in the application of industrial tlooring is the basis for recommendations designed to meet various service conditions. This flooring is monolithic, smooth, dry, warm and easy under foot. It will not crack under atmos pheric changes or grind out <>r warp under severe traffic. It can be readily cleaned by flushing. It is non-slip, dustless, sanitary, noiseless, resil ient. waterproof, fire-retardant, and practically wear proof. J-M Industrial Flooring is ideal for laboratories, battery rooms, machine shops, warehouses, etc. It can be laid over any substantial base such as wood, concrete, brick or tile which, in itself, is strong enough to carry the required load. pill 13--J-M |\DLsTRUL pLOnRIM. Is V SlIFI Mll.L [ 129] Johns-.Manville Service to the Iros and Steel Kdlstry Recommendations for the proper type and thick ness of flooring required for specific conditions will be furnished on application. J-M Tile Flooring, Type "A" J-.M Tile Flooring. Type "A." is a decorative flooring, composed of specially prepared asphalt compounds, asbestos fibre, mineral fillers, and pig ments. manufactured in flat tile form. J-.M Tile Flooring is sanitary, odorless, and does not originate dust. Under the usual foot traffic to be found in buildings, it is extremely durable. It is comfortable under foot and not slippery. As it will not support combustion, it is considered a fireresisting floor and has been approved lor use in fireproof buildings. J-.M Tile Flooring is furnished in black, red. mahogany, tan. grey. blue, ivy green and olive green, in the following sizes: 6x6 in.. 9x9 in.. 12 x 12 in.. 9 x 27 in., and 12 x 24 in. The standard thickness of tile is 3/16 in., although I S in. tile can be fur nished where traffic is light. The 3 lb in. tile weighs 200 lb. per 100 sq. ft. The I. S in. tile weighs 1.34 lb. per 100 sq. ft. Fic. 16--J-M Tile Flocking in a Control ano Switchboard Room Underground Pipe Protection Adequate protection of underground pipe lines is recognized as an economic necessity to eliminate costly shut-downs, replacements and repairs which follow the burial of unprotected pipe. Fig 17--Applying Bitumen and Asbestos I elts th Pipe Line The value of underground pipe protection is determined by its ability to protect the line indef initely from soil corrosion and electrolysis. (Treater success has attended the use of bituminized asbestos felt than has resulted from any other method. The major feature of the Johns-.Manville method of pipe protection involves the use of an asbestos felt combined with a suitable bituminous cementing compound, the felt itself being impregnated with the same material The method ol application provides a durable waterproof envelope which complete!) encloses the pipe. Asbestos felt is essential because of it' resistance to soil acids, salts and alkalies, electrolysis and de cay. In combination with the bitumen it effects a positive safeguard against corrosion and electrical disintegration of the steel. J-M recommendations are bused on long experi ence in waterproofing underground structures ol every description, including over lO.(XX) miles ol pipe. Leading engineers, pipe line operating com panies. scientific societies, and associations concerned with the corrosion problem endorse the principles advocated by Johns-.Manville. L.n.gineers in the Johns-.Manville oigani/almn are available to assist in selecting the most economical materials and methods of application lor even spe cific requirement. [ 130] JOHNi-.M \N\ILLU ^bKUCt TO 1HL I RON \ N |1 >ILL1 Imhik\ I c Insulation of New Open Hearth Regenerators i SECTIONS BELOW GROUND Sil-O-Cel C-3 Concrete Recommendation ouch mixing, the Cl- 3 Concicie o i.miv, Regenerator Bases -- I he entire base oi the regenerator chambers is insulated with a minimum of 4 in. of Sil-O-Cel C-3 Concrete, covered with two 2' 2 in. layers oi lire brick. Sil-O-Cel C-3 Concrete is made b\ mixing Sil(3-Cel C-3 and portland cement, cither by hand or in a mechanical mi\er. in the proportion of four parti of C-3 to one part of portland. In' \olum.An excess ot water should be avoided. After thor- Insulation of Existing O SECTIONS AB' Pic 6--Sil-O-Ccl C-3 Coscrlte on On \ llronn Regim-ruim Omn> I"1 Insluting Cuncreti- Is Appi ied iu nit \\ ti i s in Mi vm m t (a mini ion Sil-O-Cel C-3 Concrete Recommendation Regenerator Walls -- On old regenerator cham bers constructed either of solid lire brick or a com bination ol Ine brick and reel brick the ni'iiLitnm consists of ;i minimum of 4 in ot Sil-< >-Cel C-3 Concrete i see l ies. 0 and 7 I. (.t incut (itni Method oi A ['pin ol itoi --lleioie am application ol C-3 Concrete i' Marled the entile legeneralor wall and steel work should be ci\en a w el s.md-Ma't u 11 h I tie cement umi lo \s ,is|i oil thoroughly .ill loose moitai .uni dmi i'"in th. !v" work anti remote loose scale, imi .out t'1 the steel work \fler this s.iiid-bl.i'ime ate placed through link ' i'1" on approximate!' 3 n wiiual - '!l '' rod' will be .i' neai .i' p.'"il'lf i" - 111 1 of ilie brick surl.nv dm- ' ' in the ceniei oi iln < - ' 1 ' 1' 4 in \ 4 in iin-li hi i"1' b 1 .. w I' seCliieK l.i'lrind CONCRETE I.\l \.. . .;;.i.i i"U Me appi :cat n in o! u- -lO'iki ma; i- tinkels.l in .1 I 11 : *1 I; i .1 ' . 1 : 1 . !'iai! I .' n , .: a i: urllmg ii or.I.i'liiiiil trtuvrit if ! hr .!. ' re- i t '..'.iiI'ami I- 11 - ui I pin .trinii m : \i!.t Mu iii lline I- Sil-O-Cel Brick Recommendation Kesie Herat nr Walls Wnui .ill cvieimr brick- -............. : -.i -ihijk: - in-ill.iivuilii 4 _ m "I -< il \ .1::: 1 .1 i I'.lkk ill-lead "I '-lipcIcN Ilk1 111- .I.i;i >m iinni'ikd in -i.nni.iui 11re buck -i/e 11 in \ I .m v 1 . in t- placed between liie shell and ihe biukunik ,i- ilk- work pmere-e- 'l l;;. ti 111 iiulil In oMl-truCt .1 IllollnllllllC kali ill ei|ll.ll in-, il. uni" \ .i I ue -U lull pi mi I. il is neces-ari in lay up ilk Ni-iM.il Natural Brick in a mortar nl the -.ink niauii.il. will) the tlunnc-i pn--ible rubbed ti>inI' I In- mortar i- Iurnished at the rate of SO Ik pei I In mi-.iiul brick. At tile arches, the tile brick is ^attie-1 iliumelt to the -teel. as previously noted in llie >npere\ recommendation. Regenerator Roofs--When the roof i- insul.iicJ with 2 .- in. ot Sil-O-Cel Natural Brick instead ni superex. tile Sil-O-Cel is laid over the -tirlace in a -mule laver kith tile brick- tightly butted together and linislied kith a slurrv of Sil-O-Cel Mortar. >CD CC UJ H* Z UJ o <0 Q CC O o UJ CC o - z DC 3 h UJ CC UJ CO < UJ -J 0.. lOl - ' j .mi