l*ol) cliloi iii.ili d IWplicti vis (l'(Jli's) from iS'ulural Waters
by J \mi,> \V. III.nt turn
Michiptin
n\ \ntnrnl /{<-omrrr.t
M Cfer (Jitulily (.nntrttl lhti\wn
J,anting, MkU, V.'l'// J
The discovery of polyurethane foam's ability to extract PCD 1 s from water (CESSER cj n_l . 1972) was viewed with great Interest by our pesticide laboratory. it was hoped that the me t hod wouId aid in the me asu remcn t of 1ow ppt (parts per trill ion) in the Great Lakes and its tributaries in that it increased both the extraction efficiency and the amount of water that could be conveniently analyzed.
In monitoring Michigan's tributaries for PCB's a 5-ga!lon30`hour composite sample is collected and o one-gallon aliquot I s placed in a bottle equipped with a teflon-lined cap and con taining 100 ml of hexane. Since the remaining U gallons is dis carded it provided a good opportunity to test and compare the polyurethane foan method. It was found that in relatively clear rivers with Iow levels of PCB's comparable results were found between the two methods of extraction, however, in the more turbid rivers with high conecntrations of PCB's much lower levels were found using foam extraction.
In order to examine why this disparity occurred a series of experiments were run using spiked distilled and eutrophic lake water,
METHODS
Two diSTo polyurethane foam pluas (3^x^b mm) were placed in glass columns (22x900 mm) and pre-washed with ISO ml of hexane, $0 ml of acetone, and finally SO ml of distilled water. Water, Spiked with PCB's. was passed through the column at a rate of 250-2-75 m I /m i n. The PCB's were eluted from the column with SO ml of acetone followed by 100 ml of hexane. The aqueous portion of the cluatc was discarded and the eluotc was washed wi th a I073 sodum chloride solution to remove the acetone. The eluate was dried with anhydrous sodium sulfate and concentrated before analysis by gas chromatography.
A Varian Aerograph Model 17^0 gas chromatograph was used for the analyses. It was equipped with a tritium foil electron capture detector and a 6 ft x in (00) Pyrex glass column pack-
622
l<| r* IfitItfMrtilftI ('>>lt * ii"H A T in|i ) ,
OSM 028063
STLCOPCB4012025
ed with
S. E. 30 and 67, Of-I on Chromsorb W (HP). The column
temperature was 200C and the detector, 220C. Quantitations
were based on the peak heights of two prominent peaks represent
ing four chlorine isomers. No change in isomer pattern was noted
during the experiments.
RESULTS AND DISCUSSION
Ten jig of Aroclor 1 254, dissolved in acetone, were spiked in 3'lltcr quantities of distilled water and lake water. In addi tion 10 jig were spiked directly on the foam column. The recovery from distilled water was the same as the directly spiked column, while the amount recovered from the lakewater was only one-half as much (Table 1) .
TABLE 1
Mean Extraction Efficiency of Polyurethane foam for Aroclor I 254.
Method Spiked Amount Spiked (jjg) Replleations Recovered (pg)
Column 10 5
8.9^0.6
Distilled Water 10 5 8.9^0.4
Lake Water 10 5
**.5-0.9
In order to determine why the recovery from lakewater was so low distilled water and lakewater were proportionately mixed be fore spiking and the column eluate was extracted as well as the foam plugs. Four different 1500-ml water samples were spiked with 10 jug of Aroclor 1254, One contained 1500 ml distilled water, one 1000 ml distilled and 500 ml lakewater, one 500 ml distilled and 1000 ml lakewater and one 1500 ml lakewater.
The amount of Aroclor 125** recovered from the foam columns was proportional to the amount of distilled water present (Table 2), In this experiment a higher recovery was obtained from the lake water (64 vs 457.) but the recovery from distilled water was also higher (104 vs 897',) . The same lakewater was used for both experiments and contained 22 mg/I suspended solids.
The cluatcs from the columns were extracted with ! 575 ethyl ether In hexane and hexane as per EPA (1971) recommendations and e considerable quantity of 1254 was found in those eluates con-
623
0SW 028064
tainlng lakewater (Tabic 2). When the quantity of Aroclor l25h
In the eluote is added to the amount extracted by the foam column, neorty all of the Aroclor is accounted for. Thus it appears that most of the unrecovered (from the foam) Aroclor 125k is passing through the colupin rather than being irreversibly adsorbed onto
the foam.
TABLE 2
Extraction Efficiency of Polyurethane Foam for Aroclor 1254 in Hi xturcs of Lakewater and 0 i s t i 1 led Water,
Water Hixture
Distilled
Lake
1500 ml
0 ml
1000
500
500 1000
0 1500
Spiked (jjg}
10 10 10 10
Recovered (he)
F oam
E 1 ua to
Total
10.k
0.2
10.6
9.2
0.8
10.0
7.5 1.5
9.0
6. k
2.7
9- 1
The way the Aroclor passes through the foam column is pro bably adsorbed onto small particles which can pass through the porous foam. In order to test this hypothesis lake-water (sus pended solids=lk m.g/1) was filtered thru a 0.45-p membrane fil ter. The filtrate, along with unfiltered lakewater and distill ed water were spiked with Aroclor 125k and passed through foam columns. The extraction efficiency of the foam was approximately the same for distilled and filtered lakewater, but much lower for the unfiltered lakewater (Table 3).
An attempt to duplicate the results obtained with lakewater by suspending HontmoriI I onite clay particles in distilled water failed as the water was extracted equally ef f i c i ent I y (9) /) with 0, 10, 20, and 30 mg/I clay. This indicates that cither the clay particles did not pass through the foam or that Aroclor l2Sk is much more strongly attracted to the foam than the clay.
This study indicates that polyurethane foam cannot be used reliably to extract PCS' s from many natural waters unless spiked samples are run from each body of water to be tested. Although this makes the foam method somewhat impractical for enriched and/
or turbid waters, it still should be a valuable technique for
clear waters containing low quantities of PCB's such as the Great
Lakes and open ocean. That is, in very clear waters the extrac-
624
DSW 028065
tlon efficiency should remjin relatively constant and spiked sam ples need not be run for each water sample. Also, perhaps corre lations can be determined between turbidity and suspended solids and extraction efficiency.
TABLE 3
Extraction Efficiency of Polyurethane Foam for Aroclor I25h in Filtered versus Unfiltcrcd Lakcwater,
Water Type
F11 tered Lake Unf1 Itered Lake Distil led
Spiked (31 g)
to 10 10
Recovered (uq)
Foam
E1uate
Total
8.8 0.1* 9.2
6.9 1.1 8.0
9.1 0.2 9.3
ACKNOWLEGEHENTS
The author wishes to thank M, J. Zabik and G. C, C. Su for their helpful suggestions and critical reviews of the manuscript.
LITERATURE CITED
EPA: Methods for Organic Pesticides in Uater and Wastewater, National EnvironmentaI Research Center. Cincinnati, Ohio TtS268 (I97U.
CESSER, H. 0., A. CHOW, F. C. OAVIS, J. F. UTHE , and J. REINKE: PCB Newsletter U, I 1-13 (1972).