Document BR7JzKxZwpre0r30rnv8ej58J

FILE NAME Ford FD DATE 1968 July DOC FD036 DOCUMENT DESCRIPTION Internal Report - Exposure to Asbestos During the Servicing of Brakes of Passenger Cars Report 41/68 Exposure to Asbestos during the Servicing of Brakes of Passenger Cars M July 1968 Fridhishal Dr D E Hickish > 1/163 Industrial Hygiene Specialist - 8006 1202 INTRODUCTION This investigation was undertaken in view of the increased national concern regarding and of the impending revision of the exposure Asbestos to asbestos Regulations of the Ministry of Labour could One involve of the operations within the exposure to asbestos dust is motor industry which the cleaning of brake drums and clutch assemblies routine servicing by blowing blowing normally carried out during with compressed air jets The brake linings in current use may contain 40 to 60 asbestos when manufactured - the asbestos being normally in the chrysotile form and occasionally in the amosite form Crocidolite asbestos is said not to be used II FIELD INVESTIGATION It was considered that any hazard to health from exposure to brake or clutch dust within the Dealer Repair Organisation would be more widespread than within Ford of Britain so the initial investigation was carried out at a large Main Dealer service bay At this garage the number of cars per day given a routine service varies between 10 and 20 but not all servicing involves brake cleaning Air sampling was carried out initially on two T.Ps occasions A and B using thermal precipitators as the sampling instruments On the second occasion samples were also collected on membrane filters ' This latter technique has been developed in recent years and is likely to become the preferred method of sampling for asbestos in Great Britain and the U.S.A. eee In 8006 1203 2 In each case measurements were made a By the side of cars being given a service which included brake cleaning and b In the cloud during brake cleaning and then near to the car for the remainder of the service period As the mechanic normally blows the dust away from himself the sampler at b would be exposed during blow to dust concentrations greater than those actually pertaining at the breathing zone It was considered however that to factor sample in this way would provide an additional of safety Details of the sampling are given in Table 1 when zone A further period of air sampling membrane filter samples were collected of the brake operative by means C was carried out from the breathing of a personal sampler with suitably modified flow rate approx 250 min ) The sampling covered an entire work shift during which brake blow was carried out on the following vehicles 5 Corsairs 1 Zodiac 4 Cortinas 1 Prefect The thermal precipitator slides were subsequently incinerated and examined by projection using- using- a 4 mm objective and X.17 eyepiece The membrane filter samples were rendered translucent by the addition of triacetin and examined in a similar manner contrast microscopy was not used | Phase The results of the T.P. counts for occasions A and B are given in Table 2 and for the membrane counts on the eee occasions 8006 1204 III IV occasions B and C in Table 3. The counts are expressed in terms of particles with diameter greater than l and of fibres i.e. particles with aspect ratio greater than 1 and length greater than 5 LABORATORY INVESTIGATI In view of the relatively few fibres present in the air samples a laboratory investigation was undertaken comprising microscopic examination of samples from brake lining material which was filed to produce dust and brake drum dust collected by spatula from brake drums immediately prior to blowing The samples were sieved through mesh screens and then examined before and after incineration The results are shown as fibre proportions in Table 4 Samples of material collected from the brake drums of a an Anglia van b a Mark II Cortina and c an Anglia car were analysed by Dr S Holmes of Turner Brothers Asbestos Co.Ltd and his findings are shown in Table 5 DISCUSSION OF RESULTS a Standards of dustiness In June 1968 the British Occupational Hygiene Society published Hygiene Standard for Chrysotile Asbestos Dust suggested that in order to reduce the risk of contracting which asbestosis to % of those with a lifetime's exposure to the dust the accumulated exposure should not exceed 100 years i.e. 2 fibres for 50 years or 4 fibres for 25 years In this standard fibres are eos defined defined 8006 1205 Table 2. Results of Thermal Precipitator Samples Sample Sample Sample NoNo.. Sample details Sample time mins Static - by car Al 30 A4 45 A6 30 weighted average B1 45 B5 35 weighted average Dust concentration Particles 1n Fibres > 5 99 134 62 , 103 124 102 115 2 1 2 1.57 0.5 0 0.28 b In dust cloud then static 223 30 223 45 223 35 weighted average B3 45 B7 35 weighted average 71 141 92 106 103 181 137 3 2 0 1.64 0.5 0.2 0.37 8006 1210 Table 3. Results of Membrane Filter Counts Sample Details 1. General atmosphere samples a Static by car B2 B6 weighted average b In dust cloud then static B4 B8 weighted average Sample time mine Fibres 45 1.12 35 1.42 1.25 45 1.71 35 3.62 2.55 II Personal samples C1 C2 C3 C4 C5 Sample lost C6 33 weighted average 60 0.63 56 1.12 59 0.21 56 0.96 64 0.38 70 0.79 ' 0.68 8006 1211 Table 4. Fibres - as percentage of total particles observed Sample Brake lining material Brake drum dust borne dust Fibre proportion % Incinerated | Incinerated 28 0.6 12.3 1.6 - 1.3 Table 5 Analysis of Brake drum dust SaSmapmlpele Anglia Van Electron diffraction microscopy Chrysotile present Cortina Mk.II 3.Anglia car ray diffraction normal specimen ~ ray diffraction extracted specimen) Iron & quartz | Less than % present No | chrysotile chrysotile possibly 0.1 detected to % Less than specimen 1 As specimen 1 8006 1212 Report 52/68 Exposure to Asbestos Dust during Brake Maintenance Operations on Commercial Vehicles Fleet Repair Garage Dagenham October 1968 a 1 Dr D E Hickish - 1/163 Industrial Hygiene Specialist 8006 1213 INTRODUCTION This study was undertaken to assess the degree of exposure to fibrous dust in brake maintenance procedures on commercial vehicles and to provide comparative data relating to a previous study on operators working on passenger cars II INVESTIGATION Air sampling took place in the garage on the 19th September 1968. Membrane filters in conjunction with Casella personal samplers suitably modified to provide a flow rate of 200 cmmin were used and the following sampling procedure adopted a Personal samples were collected from the brake blow off operator Mr Crone and the mechanic working in the adjacent bay Mr Hillman during the blowing operation The filters were then changed and replaced to run for the rest of the shift b Static samplers were positioned at three points A. and C. about 20-25 from the source of dust generation and separate samples were collected for the morning and afternoon shifts . The sampling positions are shown in Fig.1 The collected samples were subsequently removed to the laboratory and after preparation examined by projection microscopy for the presence of fibres greater than 5u equal to A fibre is defined as having or greater than 3 an aspect ratio eee III RESULTS 8006 1214 III IV RESULTS Table 1 shows the fibre counts per cm for each sample collected DISCUSSION OF RESULTS i Standards of dustiness In a previous Report 41/68 Exposure to Asbestos during the servicing of brakes of passenger cars reference was made to the Hygiene Standard for Chrysotile Asbestos Dust proposed by the British Occupational Hygiene Society This standard suggested a Threshold Limit Value of 2 fibres for an exposure period of 50 years Categories of dustiness were proposed as follows Dust Category Negligible Low Medium High Concentration fibres cm averaged over 3 months 0 - 0.4 0.5 - . 1.9 2.010.0 2.010.0 2.010.0 10 ii Field Investigation Static Samples As the blowing operation took place in the early part of the morning shift the concentrations obtained at the static positions during the afternoon shift samples 8 9 10 probably represent the background contamination Thus it can be seen that the generation of a dust cloud by blowing off dust from commercial vehicle brakes results in increased background contamination of 3 to 4 times the background level at any point within a radius of 20-25 ft The concentrations are all well below the TLV and with one exception come within the Negligible dust category ... Personal Personal samples The fibre concentrations for the mechanic engaged on the blowing task taken for the duration of the operation shows an exposure of nearly 4 times the TLV while the concentration measured in the breathing zone of the mechanic working in the adjacent bay during the same period just exceeded the TLV The personal samples from the two mechanics taken over the remainder of the shift give similar results When the samples for the two mechanics are calculated on the basis of weighted concentrations the exposures are below the TLV and come within the Low dust category CONCLUSIONS In the light of the environmental data and of the irregular intervals at which cleaning is carried out it is not a daily procedure it does not appear . that a significant hazard to health should occur in the | case studied Nevertheless the conditions which obtain during the blowing operation are extremely unpleasant and alternative methods of cleaning should be investigated or measures adopted to minimise personal exposure e.g. local ventilation or use of suitable respirator 8006 1216 Table 1. Results of Membrane Filter Counts Sample No. DescriDepscription tion 1 Personal Mr Crone Brake maintenance Front brakes blown out in this period 2 ,| Personal Mr Hillman Clutch repair procedure at adjacent vehicle bay Flow Duration mins Concentration min fibres Dust Category 99 193 7.09 Medium 127 207 2.25 Medium : 3 Static Position A. 190 232 4 Static Position B. 185 133 S Static Position C._ 180 206 | ~|~ 6 Personal Mr Crone.One rear brake assembly 317 180 blown off at beginning of sampling period : T Personal Mr Hillman Clutch repair ~ | procedure at adjacent vehicle bay 278 148 8 Static Fosition ^ 806 9 Static Position 3 1217 10 Static Position C. 186 211 186 170 135 172 0.17 0.49 0.28 0.08 0.11 0.07 0.11 0.07 Neg Nag Neg Neg Neg Neg Neg Neg weighted average concentrations average Mr Crone Mr Hillman 1.75 Low 0.79 Low SKETCH OF INIRANGEMENT OF N SAMPLING SCHEME AT REPAIR 19. SEPTEMBER 1968 GARAGE Fig1 WELDING _s3 TYRES 1 1 | | | 1 |. | @ | 1 | 1 - ad a i 8006 1218 . ote os 8 " . 8006 1219 June 5 1973 oct Mr W. Hombach Mr N. Gordon 3GK3 1/431 een - Subject EXPOSURE EXPOSURE TO ASDESTOS DURING BRAKE CLEANING The Port of Europe Service department are considering approved equipment for European Dealers including items for the control of the dust produced when brake drums are blown out In Ford of Britain there has bom some use of items like the Drumolene unit shown on the attached leaflet and we are about to conduct some further tests of their efficiency and of their ability to comply with National legislation I should be interested to know whether in Ford of Germany you have legislation which applies to brake cleaning and whether there are any pieces of equipment for dust control which are approved by Government Agencies ent Pither Or D. Hiokish Industrial Hygiene Specialist 1/163 94-3330 PHIC 8006 1220 PQ July 5 1978 Dr D E Hickish cc R Gordon 1/163 Subject Exposure to Asbestos during Brake Cleaning A demonstration of the Drumclene brake dust extraction system has been arranged with BT Sales and Services Ltd the manufacturer of the equipment It is scheduled for 10.30 on Tuesday July 11 in the Warley Basement Garage Please advise the name and extension of the Industrial Hygiene representative who will be attending the meeting In addition we have a prototype equipment from another supplier that can be studied after the Drumclene representative has left Nemlen Nemlen P J Hinton European Service 1/451 84 3121 - . * 8006 1221 July 17 1973 co Mr P.J. Hinton Nr Goribon 1/451 1/431 Subject EXPOSURE TO ASBESTOS DUST DURING BRAKE CLEANING As requested the demonstration of the Drunclene brake dust extraction systes by the B.T. Sales engineer was attended on July 11 1978 While the engineer weg demonstrating the olarning ability of the exdgment on the rear brake nogembly of a Cortina a high intensity light beam as described in the Schedule of the Certificate of Approval No. AP 1 2363 of the Asbestos Regulations 1969 was used to assess the containment of the dust by the equipment No dust es seen to escape from the equipment during the cleaning indicating that there should be no hazard to health if this equipment goes into service in the dealerships . s a t . ' | t- 2 A..J Croc'ten Intustrial Hygiene Analyst 1/163 34-2452 8006 1222 .PQ .PQ S ELTD SHEFFIELD oe to e 8006 1223 we The B.T. DRUMCLENE Drumclene enables the effective method of Air Blast be employed in total safety Cleaning to The Drumclene is a weight steel cylinder spigot mounted on to a detachable frame which is fitted with fully rotating castors The spigot attached to the base of the cylinder is 1 diameter which enables the Drumclene to be mounted on a standard Trolley Jack for height adjustment if required Trolley Jack adaptors are available which when fitted increase the spigot diameter to 1~ The vehicle end of the Drumclene is partially enclosed by a segmented diaphragm which forms a dust seal behind the backplate of the exposed brake mechanism when the unit is in position A fabric sleeve with elastic wrist band enables the operator to handle the button air gun inside the unit Large shatterproof viewing panels are incorporated in both models particles Whilst the unit is complete within itself it is connect to a standard line supply via tnheeces"sarByStPo Socket mounted towards the rear end of the unit The blast of air on to the exposed brake mechanism within the Drumclene is sufficient to dislodge the dusts etc. but in majority of extreme cases it may be necessary to dislodge any solidified matter with a stiff brush All dust and solids are then drawn through the bottom outlet of the unit which is designed to accept most Suction Cleaner hoses up to 23 bore Industrial by use of the push reducing adaptor supplied Suction Cleaner specifications are noted on the page but whatever their capacity we recommendoptphoesu itn e of a type having bag collection and additional filtrati suitable for handling dust and asbestos 8006 1224 This model is designed to accommodate a wide range of vehicles with drum brakes in the 7 to 12 diameter range A single sleeve situated in the rear end of the cylinder enables the operator to complete the cleaning process with efficiency and safety In some cases drum brakes are serviced and cleaned whilst the vehicle is in an elevated position i.e. on a vehicle lift in these cases we recommend the use ofa high stand Part No. BT200 as illustrated on the opposite page Whilst the general requirement of a suction cleaner is outlined in the intro ductory paragraph it is essential that for use with the BT200 the cleaner must have in addition to filtration etc. a minimum airflow of 50 CFM with its hose connected Designed for use on the larger diameter drum brakes found on commercial vehicles etc. with back plates in the 12 to 19 diameter range Two access sleeves are fitted as standard to this model but if necessary a third sleeve can be fitted to the centre of the circular rear window If ordered with this sleeve fitted the model number becomes BT 416 This third sleeve affords additional access when the Drumclene is used on drum brakes of greater depth than standard e.g. Double Wheel Assemblies In some cases it has been found that Fleet users only handle a specific drum size for example 17 diameter In these instances we are able to offer special size diaphragms solely for Fleet use It will be appreciated that a suction cleaner for use with the BT400 has to have a larger flow than that used on the smaller model therefore we recommend a cleaner capacity of 95/100 CFM in addition to the filtration requirements mentioned previously 7 B.T. Cra 400 8006 1225 Spare Parts List Description Top Window Sealing Strip Top Window Rear Circular Window Sealing Strip Rear Circular Window Rear Window W 3rd Sleeve Fabric Sleeve Sleeve Retaining Clip Castor Thumb Screw 5/16 W Diaphragm Complete Air Line Assembly Outlet Reducer Diaphragm Elastic W Clip BT 200 BT200 _ BT200 BT200 BT200 BT200 BT200 BT200 DG271 BT200 Spare Part Code Number BT 400 BT 200 MKII BT200 - BT400 BT200 BT200 _ = BT400 BT200 BT400 BT200 BT200 BT400 BT400 DG271 BT400 _ _ BT200 BT200 BT200 BT200 BT200 BT200 DG271 BT200 When ordering spares please quote Description and Part Number BT 400 MKII BT200 BT200 BT400 BT400 BT400 BT200 BT400 BT200 BT200 BT400 BT400 DG271 BT400 SERVICE LTD A B.T.SALES 2 B.T.SALES B.T.SALES SHEFFIELD B.T. Sales & Service Limited Huntingtower Road Sheffield 7GR Telephone 685021 & 661424 STD 0742 Agent's Name and Address ? 8006 1226