Mr. Don Dehner Insulating S Materials Corp. 1042 Central Industrial St. Louis, Missouri 63310
Dear Don:
Re: Asbestos Removal in DU-2
In preparation for the DU-2 turn around, IMCO has been removing asbestos in sulation from the unit.- On June. 26, 1984, approximately thirty feet of in sulation was being removed from a ten-inch.line.
Wet methods were used during the removal, and no visible dust was noted. Employees wore the required protective equipment. Clean up of the removal was thorough and effective. W' The results of the air samples collected during the removal are summarized below:
Sample No.
Location
Fibers/cubic centimeter
DU-1 ,
Personal Sample
..
0.042
DU-2
NW Corner of Controlled Area (Upwind)
None Detected
DU-3
SE Corner of Controlled Area (Downwind)
None Detected
Personal exposure was well below the 0SHA PEL of 2 fibers/cubic centimeter, and the controlled area was large enough to control the potential exposure of other personnel working in the area.
Please call if you have any questions.
Douglas^N. Nimmo Certified Industrial Hygienist
CC: V. J. Grizzle
LAM 019535
ABS-000346
. 0001*77
John A. Jurgiel & Associates, Inc.
Occupational jKtaltk and Safety Consultant:
2092 CONCOURSE DRIVE ST. LOUIS. MISSOURI 3I4 (3141 3 7 -7 4 8 8
July 2, 1984
Mr. Don Dehner Insulating & Materials Corp. 1042 Central Industrial St. Louis, Missouri 63110
Dear Don:
Re: Report of Asbestos Removal in the UCC Generator Room
Enclosed is a copy of our report of the asbestos removal from the #3 Turbine
in the UCC Generator Room. '
''
-
Please call if you have any questions.
Certified Industrial Hygienist
LAM 019536
ABS-000347
OOOH[7 .
INTRODUCTION
IMCO was engaged in the removal of insulation from the #3 Turbine in the UCC Generator Room. This removal was monitored as part of IMCO's ongoing as bestos control program. Additionally, the removal was done without totally isolating the turbine in a temporary housing.
BACKGGROUND The area around #3 Turbine was isolated by placing warning tape around
the turbine. Warning tape was also used in the lower level to limit access to the removal area. Asbestos.warning signs, were placed at all major entrances to the upper and lower removal areas. Plactic was used to cover electrical parts so limited amounts of water could be used during the removal. Water was initially applied from a garden-tvpe spray can. Because of the thickness of the block material to be removed, a water hose was later used. However, the amount of water used was carefully restricted so exposed electrical parts (armature) would not be damaged. The block insulation was wetted down while in place, and additional water was applied before the material was placed in plastic bags. Employees wore the required protective clothing and respiratory protection. Good discipline was exercised in the wearing of protective equip ment despite the heat build up in the closed building.
MONITORING A total of five air samples were obtained during the removal. The samples
were collected and analyzed in accordance with the OSHA Asbestos Standard (1910.1001).
LAM 019537
ABS-000348
Personal air samples were taken on two employees, however, one employee left the job site at noon to attend co personal business. This sample is not representative of this employee's eight hour exposure, and is included only be cause it does represent a peak exposure level of'1.7 fibers/cubic centimeter (f/cc). The eight-hour exposure levels of the employees working on this re moval project are better represented by the second employee's morning and after noon exposure of 0.1 f/cc.
The three area samples from around the perimeter of the controlled area were 0.006, 0.008 and 0.023 f/cc. Monitoring results are contained in the attached table. CONCLUSIONS
Personal exposures were well below the OSHA PEL of 2.0 f/cc. Although peak exposure approached this level, fiber release was generally confined to the controlled area.
LAM 019538 ABS-000349
. 000177
Sample Number
UCC-1 UCC-2
UCC-3 UCC-4 UCC-5
TABLE 1 Asbestos Removal from
#3 Turbine in UCC
Location North Boundary of Controlled Area East Boundary of Controlled Area West Boundary of Controlled Area
oo o
Fiber Concentration
(f/cc)
0.023
0.008
0.006
lr681
LAM 019539
ABS-000350