Document B9VQnr6rx3r9dRBVzmza34Vw
BEIMDIX
Cl 15 PERSONNEL MONITOR
the only air sampler with . . .
AUTOMATIC VOLTAGE REGULATION
Gives absolutely constant reading of --2% Guarantees 8 hours of midget impinger sampling
2.8 LPM A P 12" H*0 Guarantees 14 hours of gravimetric sampling at
2 LPM AP 4" H*0 Eliminates flow rate adjustments during sampling
period.
FLOAT PULSATION ELIMINATOR
Ends float bounce for precise reading
BUILT-IN BATTERY VOLTAGE TESTER
Allows instant check of battery condition
--1-- H--
RSV 0005783
BENDIX
C-115 PERSONNEL AIR SAMPLER
Guaranteed to collect 99% of the sample . . . exceeding the rigid requirements of and approved by the Bureau of Mines for Intrinsically Safe Operation in Explosive Atmospheres. Bendix superiority is demonstrated in the Cl 1 5 PERSONNEL MONITOR. LIGHT WEIGHT, COMPACT and VERSATILE ... the Cl 1 5 is an air sampler offering advanced features found in no other instrument in the field and may be used with midget impingers. micro impingers, membrane filters or respir able mass samplers. Powered by a 7.5 volt, 2 amp-hour rechargeable nickel cadmium battery, the Cl 15 is supplied complete with a 110 volt/60 cycle battery charger. A precision diaphragm pump and hi-torque low current drain motor insures high efficiency monitoring.
Here's why the Cl 15 can give you 99% sampling accuracy
FEATURES
AUTOMATIC VOLTAGE REGULATOR Gives absolutely constant reading of ^2%. Guarantees 8 hours of midget impinger sampling at 2.8 LPM AP 12" HaO Guarantees 12 hours of gravimetric sampling at 2 LPM AP4" H,0 Eliminates flow rate adjustments during sampling period
FLOAT PULSATION ELIMINATOR Ends float bounce for precise reading
BUILT-IN BATTERY VOLTAGE TESTER Allows instant check.of battery condition
LEAD-IN-AIR ANALYSES Simple 3-step procedure provides accurate analysis using Bendix Inorganic Lead-inAir Reagents.
TDI-MDI DETERMINATIONS Will provide threshold limit values from 0.01 to 0.08 PPM using Bendix reagents and color standards.
C-115 PUMP PROVIDES THE NECESSARY VACUUM FOR PRACTICALLY ANY PORTABLE GAS ANALYSIS TEST
The C-11 5 is designed for the collection of toxic and combustible gases, vapors, dusts, fumes, and mists which are then evaluated by various analytical techniques. Numerous Bendix portable gas detection instruments and Colorimetric Detector Tubes can be used with the Sampler. The device, therefore, can be used to collect samples of explosive gases, oxygen, ammonia, carbon dioxide, carbon monoxide, chlorine, hydrogen chloride, hydrogen sulfide, mercury vapor, nitrogen dioxide, sulfur dioxide, toluene diisocyanate, lead dust and fumes, and chromic acid mist. Dust counts can also be made, using Midget Impingers in conjunction with a microscopic analysis. Particuiate sampling can be performed for radioactive dust and beryllium dust. A desired sample flow is obtained by setting the flow adjust screw to an indexed position on the flow meter. Our standard instrument comes factory calibrated at 2.8 LPM and 2.0 LPM. Special air flow calibrations are available on request. The C-115 is equipped with a tube fitting on the outlet or exhaust side of the pump. It can be used in positive pressure applications.
RSV 0005784
IMPINGER SAMPLING
The C-115 Air Sampler is designed for use with Bendix Calibrated Midget Impingers and Bubblers in sampling dust, gases, and vapors. It is the only Personnel Air Sampler on the market that guarantees 8 hours of continuous sampling at 2.8 LPM A P 12" HaO.
Threshold Limit Value Determinations from 0.01 to 0.08 PPM using Bendix TDI-MDI Reagents and Color Standards (Toluene Oiisocyanate/MethyleneBis (4 Phenylisocyanate) are accomplished with the use of the midget imprnger.
RESPIRABLE MASS LAPEL SAMPLER
The Lapel Sampler, when used with the Bendix Cl 15 Pump, simulates the collection characteristics of the human lung. As air is sampled, the cyclonic action of the unit separates the coarser particles of dust (those which would deposit in the upper respiratory passage) from the finer, more harmful particles which penetrate into the lung. The larger par ticles fall to the bottom of the tube, the finer particles are drawn to the filter assembly in the capsule, where they are trapped on a filter mem brane for subsequent analysis, either weighing or counting. Approved by the Bureau of Mines for Intrinsically Safe Operation in Explo sive Atmospheres and the Environmental Health Service Bureau of Occu pational Safety and Health.
RESPIRABLE DUST SAMPLER Filter Paper Holder adapts the Cl 1 5 for personnel monitoring or sampling for the detection of lead dust, radioactive particulate, beryllium and other hazardous particulates.
ANALYZER FOR INORGANIC LEAD FUMES* Simple 3-step procedure provides accurate analysis exceeding the requirements of the "Occupational Safety and Health Act of 1970." Using Bendix Inorganic Lead-in-Air Reagents and Color Standards, measures accurately within a range from 0.02 mg. /m3 to 0.4 mg./mJ of inorganic lead. This field method for atmospheric sampling provides immediate and accurate determinations of semiquantitative lead concentration in air throughout an entire workday. In contrast to the chemical method that could take 8 hours or more, the field method for analyzing the same number of samples requires less than 10 minutes with the Cl 15.
ANALYZER FOR TDI AND MDI * * The Cl 1 5, when used with calibrated midget impinger, will provide Threshold Limit Value De terminations from 0.01 to 0.08 PPM using Bendix ; TDI-MDI Reagents and Color Standards (Toluene Diisocyanate/Methylene-Bis (4 Phenyl isocyanate).
RSV 0005785
Cl 15 ATTACHE UNIT 3600-18
For total convenience the Cl 1 5, battery charger and all accessories fit compactly into this handsome attach^ style carrying case. Case provides excellent protection for unit, while portfolio in cover is ideal for valuable reports, test papers, instruction litera ture and suggestions for care of unit.
Description
Part Number
C-11 5 Air Sampler w/Battery and Charger 3650-10
C-11 5 Air Sampler Only
3650-05
Nicad Battery 7.5V
3600-31
Battery Charger 110V 60Hz
3600-20
Standard Calibrated Midget Impinger
7202
Impinger Holder
3600-35
Sampling Head Ass'y w/Cyclone,
Hose and Clip
3900-90
Sampling Cassette/Capsule Assembly 3900-906
Filter Holder 25 mm Pkg. of 6
1107
Filter Holder and 37 mm Membrane
3600-309
Filter (0.8 Micron Size) for Asbestos
Dust Sampling.
Description
Part Number
*37 mm 3-Part Plastic Filter Holder. *37 mm Membrane Filter
(0.8 Micron Size).
3600-300 3600-301
Filter Paper 25 mm Pkg. of 100 2 ft. Rubber Tubing 3/16 ID Code 40/20 Inorganic Lead-In-Air
60692 2110-32
Reagents with Color Standards for Lead Dust in air evaluation (50 evaluations)
2250-10
TDI/MDI Color Standards
2200-30
TDI/MDI Reagents
2200-20
Attach^ Case w/Ethafoam Insert
3600-18
`Part Nos. 3600-309.3600-300and 3600-301 Filter Holder and Filter Media (0.8 Micron Size) complies with Federal Register Regulations 1910.93a tor Asbestos Oust Sampling.
` Ref. Enrique A. Quino -- Field Method for the Determination of Inorganic Laad Fumoa in Air -- The Journal of the American Industrial Hygiene Association -- Voi. 20. No. 2 (April 1959|. Printed in U.S.A.
"Ref. Marcali. Kalman -- Microdetermination of ToluonodUaocyanatoe in Atmosphere -- Anal. Chem: 29. 552 (April 1957). K. E. Grim and A. 1. linch -- Roeont Isocyanate-ln-AIr Analysis Studiee -- AIHA: Vol. 25 (May-June 1964).
NATIONAL ENVIRONMENTAL INSTRUMENTS, INC.
P. O. Box 590. Pilgrim Station, Warwick, R. I. 02888
Tel. (401) 738-3710
Cable NEICO TWX 710 387-1584
Distributed by:
ZinkSAFETY EQUIPMENT
W OF MISSOURI, INC.
10282 6ACH BOULEVARD ST. LOUIS. MISSOURI 63132
PHONE 314-426-0886
mdi RSV 0005766
NATIONAL ENVIRONMENTAL INSTRUMENTS. INC., BOX S90 WARWICK, R.i. 02888
MARKETING ENVIRONMENTAL HEALTH, AIR POLLUTION * SAFETY INSTRUMENTATION
TEL. (401) 738-3710
TWX 710-387-1548
CsbU: NEICO
Price List for
Effective July IS, 1972
Supfrceoes All Previous Phicf Lists
C-115 UNIVERSAL PERSONNEL MONITOR
CATALOG NO, 3650-10
3650-K0 3650-75
3650-05 3600-31 3600-20
DESCRIPTION C-115 Personnel Monitor, consis nno of: C-115 Pump, Intrinsically Safe Rechargeable
Nicad Battery, Battf:y Charger. Mioget Impinger Hoi.der
C-1J5 Pl RSONNi MoNI low, CONS 1 S I I NO Or; 3650-10 pi u-i C- MS Laiti Sampi kh, C AS S F 1 1 F. /C APS lilt. A: .1. M n LY
C-115 Personnil Monitor Kit, consisting of: 3650-10 plus Mioget Impinger, Lapel Sampler,
Cassette/Capsule Assembly, Carrying Case with Custom Insert
C-115 Personnel Monitor (Rechargeable
Battery not includco)
Intrinsically Safe Rechargeable Nicad
Battery (7.5V)
Battery Charger ll(:VAC. 60 H
PRICE $325.00
345.00 3V5.00
250.00 47.80 32.50
REFER TO REVERSE SIDE FOR ACCESSORIES
ALL PRICES ARE F.O,B. BALTIMORE, MARYLAND
TERMS: NET 30 DAYS
PRICES SUBJECT TO CHANGE WITHOUT NOTICE
RSV 000578?
CATALOG NO.
DESCRIPTION
IMPINGER SAMPLING
7202 2200-20
2200-30
3600-35
SlANnANII C ALl fllf A T F D Ml OGf T ImPI N(\F R TDI/MDI RrAorNfs TDI/MDI Hcrme i i callv Si aleo Color Stanoard Mioser Impingcr Houder (Replacement)
RESPIRABLE MASS LAPEL SAMPLING
PRICE
$13.35
13. JO
2 J .90 17.60
3600-90 3600-104 3600-100
3600-97
607 J 4
3900-90 3900-906
2 Stage Respirable Mass Lapel Sampler
37mm Plastic Filter holoer, Loaded w/VM-J filter 37mm Plastic Filter holder, (less filter support
and filter)
Filter Paper Support
Replacement Filters, 37mm, VM-l, 5 Micron
Pore Size for Respirable Sampling 100/ox
HoseSampling Heao Assembly with Cyclone,
& Clip
Cassettc/Capsule Assembly for 3900-90
32.05 1.50
.75
.45
23.00
30.00 1.25
FILTER MEDIA SAMPLING
As BEST05
3600-309
3600-300 ,3600-301
Filter Holder & 37mm Membrane Filter (0.8 Micron Size) for Asbestos Dust Sampling
Consi st s Of :
37mm, 3- Par r Plaf i k Filteii Hoi.opr
Filter Membrane, 37mm (0. H Micron Size)
1.50
1.25
23.00/eox or '100
3600-310
3600-300
60194
Inorganic Lcao Compounds (P ERSONNEL MoNITORINo)
37Filter Holder &
mm Membrane Filter
(0.45 Micron Size) for Sampling Leao ano Its
Organic Compounos (except leao arsenate).
(Complies with Federal Register Regulations
1910.93u and ANSI 237.11 - 1969.)
Cons is t`; of:
37mm, 3-Part Plastic Filter Holder Filter Membrane, 37mm (0.45 Micron Size)
1.50
1.25
23.00/box of 100
2250-10 60692 1107 2110-32
3600-18
Inorganic Lead Fumes Analysis
Coot 40/20Inorganic Lead-in-Air Reagents,
Filter Media, VM-l, 25mm for 2250-10
6069225Filter Hol der,
mm Open End, used with
Rubber Tubing, 3/16" I.D, 2' long for 1107
Attache Case with Ethafoam Insert
7.50
16.5.5/box of UK)
35,50/aox of 6 .40
30.00
RSV 0005788