INTERNAL CORRESPONDENCE
UNION CARBIDE CORPORATION technical center PO BOX 0361. SOUTH CHARLESTON. WV 25303
To (Name) 0*vs*on Location Area
A. J. Bonham 770-201 511
E. R. Hunter - 740/4111
C. P. Maxwell - 701/2 P. D. Sherman - 701/2
Area Subject
November 11, 1986
EM&TS - HS&EA
Industrial Hygiene
Asbestos In Glass Blowing Shop
PLAINTIFFS T EXHIBIT
UC-764
C. P. Maxwell received a request from Eugene Hunter to take a look at the material used for lining trays in the oven located in the glass blowing shop. A sample of this material was obtained by C. P. Maxwell that we analyzed for asbestos. The results show possible presence of chrysotile type asbestos material. The material in the oven is crumbling and presents a potential exposure problem.
I recommend that the material be carefully removed and replaced with a non-asbestos material. You may wish to consider a thermal barrier cloth such as SiltempR which offers protection up to 3000F. If you are interested in this product, I have additional details available for your consideration.
MAP:rab 1882P
Manhar A. Patel