OCCUPATIONAL HEALTH SURVEY NO. 1022-H BEAUMONT WORKS
N. D. Johnson R. Schmidt_________________________ Field Notes
HYPALON AREA
PLAINTIFF'S
EXHIBIT
DUP-2003
1981 April 7
7-6 Respirator Fit-Test
PWith the increased emphasis by OSHA in the fourth quarter of 1980 for the fittesting of disposable respirators, the plant has elected to discontinue use of these types of respirators, in favor of the Canfo IDS with appropriate cart ridges. This policy has affected mechanics site-wide and selected employees (a phosphate sensitive individual in the Methanol Area). This group of employees are now using respirators for which they have not been fit-tested, although testing is due this year. It is recommended tfhat employees not be required to wear respirators that they have not been fit-tested ajpd trained in \ the use of^------------- - iJh?
J-7 Self-Contained Breathing Apparatus ^
The pressure of the air supply cylinder of a 30-minute self-contained breathing
apparatus was only 1600 psig. It is reconmended that the cylinder be maintained
in the full condition. A full cylinder will be one in which the pressure gauge is the full indication range or at least within 90? of the rated tank pressure. If monthly regulator checks are responsible for low tank pressures, it may be
useful to use a spare cylinder for these inspections. --/> 00
J-8 Employee Respirator Clearing
tj '
The site uses a cleaning solution of 30? isopropyl alcohol for daily cleaning of individually assigned respirators. Some locations have encountered problems when using alcohol containing solutions, which can damage the facepiece by
causing swelling or hardening of the rubber. It is recoimtended that use of alcohols should be avoided. A convenient alternative way to do intermediate cleaning is with an aqueous cleaner/sanitizer solution, e.g.. Antiseptic
Towelette, by Med-Pak Corporation, P. 0. Box 5^8, Pcca, W.V. 25159.
S-9 Gloves
FVC gloves are used as protection against carbon tetrachloride, chloroform and
other solvents. FVC gloves have a low breakthrough tine for these solvents.
Plans to evaluate more protective gloves or^ basis gtjpermeabilitv data J 2>
collected by Haskell are highly endorsed.
S-10 Spill Procedures
\ ftjl
Ar
The area has developed some emergency procedures. Three different sheets
address this item and different statements about personal protective equipment are indicated, e.g., rubber gloves, PVC gloves or only protective equipment fcr
/carbon tetrachloride. It is recommended that concise emergency spill prccedures be developed. They should contain beside other information the exact
:ypes of protective equipment that should be used in a spill situation. Chemicals with similar properties -~r 'rr rrnncfj, together. Sample procedures can be Drovided. Other areas lik^Nordel^ TEE>need to develop similar
DU 001933
N. D. Johnson R. Schmidt
Field Notes
Page 2 .981 April 7
SIPALON (Cont'd.)
S-ll Information on Chemical Hazards
a. Employees are informed about the hazards of the chemicals they handle
annually. This training is documented with the names of the snployees and
the dates they received this information,./It is recommended that the scope
of the information on chemicals with carcinogenic or embryotoxic potential
be included in the documentation.
<--
b. The Chemical Data Sheets (used and prepared by Hypalon Area) on carbon tetrachloride and chloroform which serves as information basis for employees do not contain information on the carcinogenic potential of these chemicals. This information should be added.
3-12 Respirators
a. Two face pieces of Scott Air Paks had sane soil on them/ it is reccnmended that dirty respirators be cleaned when found during the monthly inspection. dirty face piece was also found in the Nordel Area.
b. I Breathing air stations for airline respirators are marked as such. It is
reccnmended that the phrase 'blow out line before 'using mask' (Engineering
itandard S1H) be added. This appears to have plantwide application.
NOHEED AREA
\/UuO^
J-13 Air-Line Respirators
The air-line respirators in the Nordel Control Room are all similar in appearance and function. The approval designation on one of the units was by the Bureau of Mines BM-19B-36.
This style of respirator was no longer approved for use past March 31, 1980, unless modified by the manufacturer (no modification was apparent'). A similar
style of respirator was in use in the Methanol Control Room, but it carried a current approval number. Borh styles of respirator use a quick disconnect unit which appears to have been fabricated on site.
An approved air supplied respirator must use components and parts, which have been submitted to the NIOSH/MSHA approval organization and approved as a unit, this includes vortex coolers. Interchange of parts and substitution of other
parts will'void the approval.
A similar quick disconnect unit is present on the 5, 7.5 and 10-minute escape respirators.
It is reccnmended that the air supplied respirators be inspected to assure that the entire'unit is composed of approved components. In addition, the breathing air station in the Nordel Control Room should be properly identified (see Engineering Standard S1H).
AI A A *
DUP 0502290
DU 001934
N. D. Johnson R. Schmidt
Pleld Notes
Page 3 1981 Aoril 7
NORDEDP (Cont'd.)
J-14 Tee Machines
a. A coffee cup was being used bo remove ice from the ice maker. After use
it was placed in the ice bin where the handle was in contact with the ice.
It "is reccnmended that the handle not be placed in contact .with the ice,
due to the potential contamination of the handle and subsequent ice
contamination.
r
b. The ice bin is beginning to rust creating difficulties in cleaning and the
potential of rust particles in the ice. It is reccmended that the unit
be cleaned and painted to eliminate the rusty condition. ^
S-15 Respirators
Two out of five Scott Ska Paks were filled below the full mark. It is recom mended that the air pressure of emergency respirators be kept in the full range of the pressure gauge. The same deficiency was found at an escape pak in the
Methanol Area.
S-16 Refrigerator
Refrigerators for cooling food do not contain thermometers. It is recommended
that all refrigerators on the plant be equipped with a thermometer (not mercury bulb) to assure that the temperature he keptyat or below 45P to assure proper
food storage. Qr
(Y/'C-OS-17 Instrument Shop
Pans for catching'mercury were installed under manometers. Various items were
stored in the pans. It is recoimended that nothing be stored in them to impair
detection and cleanup of spills. METHANOL AREA
j"
M
7-18
Escape Respirators
a. Air purifying respirators (half-mask Comfo n with anroonia cartridges) have been* placed in various areas of the Methanol Area. The Methanol Area is adjacent to the Ammonia Area. Two of the respirators were dirty and the storage bag was not sealed to provide clean, uncontaminated storage. Scare cartridges were also stored in the box. It is recommended that the respirators be cleaned, stored properly and spare cartridges stored in a central location (in an emergengj, an employee^should not be concerned with changing cartridges).
b. Since, aninonia is an eye irritant, the area should evaluate the need for full face respirators in those locations that eye irritation could prevent successful escape in an emergency situation. It is recoimended that the need for fullrface respirators be evaluated.
DUP 050229!
DU 001935
N. D. JOHNSON R. Schmidt
METHANOL (Cant'd.)
S-18 Hearing Protection
Field Notes
Page 4 1981 April 7
a. No hearing protection is required in the Water Treatment Laboratory but is required beyond both exits. It is recotonended that signs be posted at both exits to remind employees that hearing protection is required when
leaving the laboratory. <k<
b. An air powered portable grinder had no indication that hearing protection is required when it is operated. It is recommended that the noise level be evaluated and the tool be marked if the noise exceeds the applicable iimit. 3?(/< ,
NDJ/RS/fb