Document B8q97dOx9VVKb26Ngpw2rn5oo

EXHAUST SYSTEMS, GENERAL 6 COMFORT VENTILATION Fig. 28-21. Globe thermometer (right). At left is shielded wet-ond-dry bulb thermom eter shown in Fig 28-18. Courtesy Oweni-lllinoii Glow Company Thu chart is a graphical representa tion of the thermodynamic properties of moist air That shown in Fig 28-20 is a simplified version which shows only the interrelationship of the dry- and wetbulb air temperatures and relative hu midity at sea-level pressure Much more data can be placed on psychrometnc charts so that they can be of practical value in the solution of many engineer ing problems * 3 The velocity of air blowing on the man whose heat load is being found is the air velocity Any of several instruments that measure velocities in the range from 25 to 1,500 fpm may be used, for exam ple the swinging-vane anemometer, heat ed-wire anemometer, or heated-thermom eter anemometer 4 The average temperature of the sur roundings that can be "seen" from where one is standing is the mean radiant tem perature l mrt) A spherical traverse could be made with a radiometer and the results averaged, but this is too special ized and time-consuming The globe ther mometer (Fig 28-21) is commonly used for finding mrt This is a 6-in thin-wall, hollow, copper sphere, painted a dull black on die outside, with an ordinary thermometer inserted through a hole, with rubber stopper, the thermometer bulb being at the center of the sphere For field measurements, a commercial copper toilet float with its outside paint ed black, is satisfactory It can be hung from a stand by a thread or clamp at tached to the thermometer stem The globe thermometer should be given 20 minutes to come to equilibrium before a reading is taken The globe thermometer reacts to both the mean radiant temperature and to the air temperature, as well as to air velocity If it is well above (or below) the air tempera ture, the fact that there is a radiant heat (or cooling) problem is immediately ap parent These simple readings give infor mation of immense importance, because the methods for combatting a radiant heat ex posure are totally different from those used against a connection heat problem The mrt is useful when making quick surveys because it can be used to estimate how much of a man's heat load is from convection and how much is from radia tion It can be assumed, if the air move ment is low, that the mean radiant tem perature and the air temperature contribute equally to the heat earned to the man by radiation and convection, respectively Hence, the elevation of mrt above the man's skin temperature (95 F in summer) gives the relative radiant component of bis heat load, and the elevation of the air tempera ture above skin temperature is proportional to the convected component--as m the ex ample Radiant component* F mrt -- 95 F = 175 -- 95 = 80 Convection component t --95 F = 125 - 95 = 30 % 73 27 Ho" lOtT "For a full discussion of this subject, see Chapter 3, 'Tsychrometncs," in the Guide and Data Book, "Fundamentals and Equip ment," published by American Society of Heating, Refrigerating and Air-Condibonmg Engineers, New York City, 1963 26-58