7 , r~ ABD00317722 I \Distribution si A 4 Interoffice Communication From: Date: Subject: K. W. Birck \ October 28, 1985 VCM LEAK SURVEY VIS1A Attached are the results of the completed 1985 Comprehensive VCM Leak Survey. A total of thirty-seven (37) leaks were found and repaired. Every flange, connection, valve, etc. on the attached isometric drawings was checked with a portable hydrocarbon detector (HNU). Those points with readings above 50 ppm with the probe close to the equipment as possible were considered leaks and were noted. A tabulated list of all leaks over 50 ppm VCM is attached. If there are any questions or comments, please advise. K. W. Birck Process Engineer 'T- F. G. Jeanson Process Engineer gP attachments / c:JF,JWW,DWH,CWT,RAF,CRS,AHS,VEM,VLT