Document B8opGgQvD8JbEOYbEkyj252Rk

Insulating Material UNIVERSAL GYPSUM & LIME GO. Chicago, 111.New York, N. Y.t Jacksonville, Fla. Offices: Foot Dodoe, Iowa, Kansas Cm, Mo. MILLS--Akron. N. Y.. Foot Dodoes. Iowa, Rotan, Texas CYPSUM IWSULATIONJ Reg. U. S. Patented Office Insulex is a gypsum insulating material for building con struction and is used to prevent the passage of beat, cold and sound. When mixed with water Insulex powder expands and hardens into a cellular mass in partitions, floor and ^piling spaces. It is especially adapted for use in homes, apartment houses, schools, commercial and industrial buildings where the saving of heat is a vital necessity. tion. Our staff of heating engineers will help, solve your problems on reduced radiation. A Block of Insulex Shotting Cellular Structure The use of Inauiex reduces the rise of heating plants and amount of radiation installed so that in estimating the hunting requirements of a building using Insulex insula tion special conductivity factors are required. Complete A. I. A. Specifications, reports of tests and ngmppring data on Inauiex will be furnished on applica Method of Providing Complete Insulation of House BUILDING CONSTRUCTION* SIDE WALLS (FRAME) INSULATED UNINSULATED Filling Space between 2* x 4* Studs with W No. 12 INSULEX Clapboard. Paper, Sheathing, Stud. Lath and Plaster................... Cement Stucco, Paper, Sheathing. Stud. Lath and Plaster........... SIDE WALL (MASONRY) 0.227 0.216 0.257 Lath and Plaster 0.074 0.072 0.076 Gypsolite Plaster Board and Plaster 0.071 0.069 0.073 By Using 2-Inch Furring Strips and Filling Space with No. 12 INSULEX No Furring With Furring Brickwall Wail--Plastered Inside: Strips Strips 0.332 0.209 0.263 0.179 I7>in. ................... ................................... 0.208 0.152 Terra-Cotta Wall--Stucco Exterior--Plaster Inside: 0.273 ' 0.184 12-in...................................................................... 0.193 0.144 CEILING Lath and Plaster 0.113 0.104 0.094 Gypsolite Plaster Board and Plaster 0.107 0.099 0.089 0.105 0.090 0.100 0.087 Filling Space between Joists 4-in. with No. 12 INSULEX Ceiling )oist*. Lath and Plaster. Attic Floor................................ ROOF RAFTER CONSTRUCTION 0.502 0.234 0.083 0.070 0.080 0.068 INSULATED UNINSULATED Filling Space between Rafter 4 in. with No. 12 INSULEX AsphaltorCorapo,Shingles, Paper,Sheathing.Rafter,Lath &Plaster Asbestos Shinnies, Paper, Sheathing. Rafter. Lath and Plaster.. . 0.246 0.262 0.259 0.259 0.071 0.072 0.072 0.072 0.068 0.070 0.070 .0.070 HEATING CONSTANTS--For use in determining house heating, radiation requirements when insulated with Insulex according to Universal Gypsum A Lime Co. specifications. ., The figures given are in B.tiu/s per.square foot per hour per degree temperature difference and show heat loss or con ductivity. Thffle figures can be used in figuring reduced size of heating plants and .radiation required m an Insulexea The uninsulated constants are based on those published in the A. S. EL A V. E. Guide, 1928. The insulated factors are based on internal conductivity of 0.40 for 12 lb. Insulex No. 12. . 706 Meters, Steam Builders Iron Foundry . 9 Codding Street Providence, R. I. Branch Offices and Representatives New York, N. Y---------------------------25 Church Street Pittsburgh, Pa___ ___ ;__ 1503 Oliver Building Philadelphia, Pa..._,............ 617 Harrison Building Chicago, III. ...466 Peoples Gas Building San Francisco, Calif^ __ ____________ _________Percy Keatinge, 85 Second Street Los Angeles, Calif_____ _______ _____ _________Percy Keatinge. c/o Pacific Mfg. Co., 530 West 6th Street Dallas, TexasMorey & Morey, 417 Praetorian Building Charlotte, N. C.-------------------------------------------------------------------- ----------- _______ ,,GrinneU Co., Inc.,J*. O. Box 336 Toronto, Ont., Can,. __Allen General Supplies, Ltd., 15 Toronto Street ATLANTA, Ga ,,Wm. F. Wilcox, Fourth National Bank Building Seattle, Wash. ..California Filter Co., 1005 Securities Building Kansas City, Mo_ ..Terry, Cowan & Smith, Inc., 1005 Davidson Building . Vancouver, B. C., Can------Chas. A. Moorehead, c/o R. C. Cooper & Co., Ltd., 615 Pender Street, West Bubnos Aires, Argentina, S. A------------------------------------- __Major Geo. C. Robertson. 760 Avenida de Mayo Builders of the Venturi Meter, Diaphragm Meter, Shunt Steam Meter, Etc. SHUNT STEAM METER The Shunt Steam Meter fills the need for a low priced, practical steam meter which is easily installed and accurate over a wide range. It is used to advantage in measuring steam sold or in checking the distribution of steam (also air or gas) to various buildings, departments, machines or processes. Illustration shows the complete Meter.. An orifice in the main line of flow deflects a portion of the steam through nozzles and against the turbine located in the shunt circuit out of the main line of flow. The turbine shaft extends through a housing into a condensation chamber below the main line. A damping fan attached to this shaft operates under water, keeping the speed low andeliminating bearing trouble. Magnetic drive between this chamber and the counter mechanism protects the latter from moisture. The meter is installed as a unit in 2, 3 and 4-in. lines. For larger size mains a small meter is installed in a by-pass line around an orifice in the main line. Steam Pressure Lbs. per Sq. In. Gauge Aimroximate Measuring . Range Rated Capacity of Saturated Steam Lbs. per Hour V Meter y Meter 4* Meter Low Pressure Meters 0 5 10 v 15 20 30 40 50 10-1 610 1410 2530 10-1 810 1680 3350 10-1 1000 2340 4170 10-1 1200 2750 4750 10-1 1380 2950 5150 U-f 1650 3400 3850 12-1 1800 3750 6450 13-1 2000 4050 7000 Standard Meters 50 to7o5 125 150 175 200 10-1 2650 6000 10600 10-1 3650 8250 14600 11-1 4150 9500 16600 12-1 4600 10500 18300 13-1 5000 11400 20000 14-1 5350 12300 21400 15-1 5700 13000 22700 bxtra Heavy Meters 225 250 275 300 15-1 6000 . 13700 24000 15-1 6300 14400 25200 15-1 6600 15200 26500 15-1 6900 15700 27500 Table shows rated capacities only. - Minimum Capacities equal one-tenth tabulated quantities. Where Approximate Measuring^ Range exceeds 10-1 the Meter has that overload capacity. Bulletin 234 gives complete information. 707