Insulating Material
UNIVERSAL GYPSUM & LIME GO.
Chicago, 111.New York, N. Y.t Jacksonville, Fla. Offices:
Foot Dodoe, Iowa, Kansas Cm, Mo.
MILLS--Akron. N. Y.. Foot Dodoes. Iowa, Rotan, Texas
CYPSUM IWSULATIONJ
Reg. U. S. Patented Office
Insulex is a gypsum insulating material for building con struction and is used to prevent the passage of beat, cold and sound. When mixed with water Insulex powder expands and hardens into a cellular mass in partitions, floor and ^piling spaces. It is especially adapted for use in homes, apartment houses, schools, commercial and industrial
buildings where the saving of heat is a vital necessity.
tion. Our staff of heating engineers will help, solve your problems on reduced radiation.
A Block of Insulex Shotting Cellular Structure
The use of Inauiex reduces the rise of heating plants and amount of radiation installed so that in estimating the hunting requirements of a building using Insulex insula
tion special conductivity factors are required. Complete A. I. A. Specifications, reports of tests and
ngmppring data on Inauiex will be furnished on applica
Method of Providing Complete Insulation of House
BUILDING CONSTRUCTION*
SIDE WALLS (FRAME)
INSULATED UNINSULATED Filling Space between 2* x 4* Studs
with W No. 12 INSULEX
Clapboard. Paper, Sheathing, Stud. Lath and Plaster................... Cement Stucco, Paper, Sheathing. Stud. Lath and Plaster...........
SIDE WALL (MASONRY)
0.227 0.216
0.257
Lath and Plaster
0.074
0.072 0.076
Gypsolite Plaster Board and Plaster
0.071 0.069
0.073
By Using 2-Inch Furring Strips and Filling Space with No. 12 INSULEX
No Furring With Furring
Brickwall Wail--Plastered Inside:
Strips
Strips
0.332
0.209
0.263
0.179
I7>in.
................... ................................... 0.208
0.152
Terra-Cotta Wall--Stucco Exterior--Plaster Inside:
0.273 ' 0.184
12-in...................................................................... 0.193
0.144
CEILING
Lath and Plaster 0.113
0.104 0.094
Gypsolite Plaster Board and Plaster
0.107 0.099 0.089
0.105 0.090
0.100 0.087
Filling Space between Joists 4-in. with No. 12 INSULEX
Ceiling )oist*. Lath and Plaster. Attic Floor................................ ROOF RAFTER CONSTRUCTION
0.502 0.234
0.083 0.070
0.080 0.068
INSULATED UNINSULATED Filling Space between Rafter 4 in.
with No. 12 INSULEX
AsphaltorCorapo,Shingles, Paper,Sheathing.Rafter,Lath &Plaster Asbestos Shinnies, Paper, Sheathing. Rafter. Lath and Plaster.. .
0.246 0.262 0.259 0.259
0.071 0.072
0.072 0.072
0.068 0.070 0.070 .0.070
HEATING CONSTANTS--For use in determining house heating, radiation requirements when insulated with
Insulex according to Universal Gypsum A Lime Co. specifications.
.,
The figures given are in B.tiu/s per.square foot per hour per degree temperature difference and show heat loss or con
ductivity. Thffle figures can be used in figuring reduced size of heating plants and .radiation required m an Insulexea
The uninsulated constants are based on those published in the A. S. EL A V. E. Guide, 1928. The insulated factors are based on internal conductivity of 0.40 for 12 lb. Insulex No. 12. .
706
Meters, Steam
Builders Iron Foundry
. 9 Codding Street
Providence, R. I.
Branch Offices and Representatives
New York, N. Y---------------------------25 Church Street Pittsburgh, Pa___
___ ;__ 1503 Oliver Building
Philadelphia, Pa..._,............ 617 Harrison Building Chicago, III.
...466 Peoples Gas Building
San Francisco, Calif^
__ ____________ _________Percy Keatinge, 85 Second Street
Los Angeles, Calif_____ _______ _____ _________Percy Keatinge. c/o Pacific Mfg. Co., 530 West 6th Street
Dallas, TexasMorey & Morey, 417 Praetorian Building
Charlotte, N. C.-------------------------------------------------------------------- ----------- _______ ,,GrinneU Co., Inc.,J*. O. Box 336
Toronto, Ont., Can,.
__Allen General Supplies, Ltd., 15 Toronto Street
ATLANTA, Ga
,,Wm. F. Wilcox, Fourth National Bank Building
Seattle, Wash.
..California Filter Co., 1005 Securities Building
Kansas City, Mo_
..Terry, Cowan & Smith, Inc., 1005 Davidson Building .
Vancouver, B. C., Can------Chas. A. Moorehead, c/o R. C. Cooper & Co., Ltd., 615 Pender Street, West
Bubnos Aires, Argentina, S. A------------------------------------- __Major Geo. C. Robertson. 760 Avenida de Mayo
Builders of the Venturi Meter, Diaphragm Meter, Shunt Steam Meter, Etc.
SHUNT STEAM METER
The Shunt Steam Meter fills the need for a low priced, practical steam meter which is easily installed and accurate over a wide range. It is used to advantage in measuring steam sold or in checking the distribution of steam (also air or gas) to various buildings, departments, machines or processes. Illustration shows the complete Meter.. An orifice in the main line of flow deflects a portion of the steam through nozzles and against the turbine located in the shunt circuit out of the main line of flow. The turbine shaft extends through a housing into a condensation chamber below the main line. A damping fan attached to this shaft operates under water, keeping the speed low andeliminating bearing trouble. Magnetic drive between this chamber and the counter mechanism protects the latter from moisture. The meter is installed as a unit in 2, 3 and 4-in. lines. For larger size mains a small meter is installed in a by-pass line around an orifice in the main line.
Steam Pressure Lbs. per Sq. In.
Gauge
Aimroximate Measuring .
Range
Rated Capacity of Saturated Steam Lbs. per Hour
V Meter
y Meter
4* Meter
Low Pressure Meters
0 5 10 v 15 20 30 40 50
10-1 610 1410 2530
10-1 810 1680 3350
10-1
1000
2340
4170
10-1
1200
2750
4750
10-1
1380
2950
5150
U-f
1650
3400
3850
12-1
1800
3750
6450
13-1
2000
4050
7000
Standard Meters
50
to7o5
125 150 175 200
10-1
2650
6000
10600
10-1
3650
8250
14600
11-1
4150
9500
16600
12-1
4600
10500
18300
13-1
5000
11400
20000
14-1
5350
12300
21400
15-1
5700
13000
22700
bxtra Heavy Meters
225 250
275 300
15-1
6000 .
13700
24000
15-1
6300
14400
25200
15-1
6600
15200
26500
15-1
6900
15700
27500
Table shows rated capacities only. - Minimum Capacities equal one-tenth tabulated quantities. Where Approximate Measuring^ Range exceeds 10-1 the Meter has that overload capacity.
Bulletin 234 gives complete information.