Boilers
Ironton Bernhard Boiler Mfg. Co.
Ironton - Ohio
Bbrnhard
BeuygRS
The Consistent Boiler
The COMBUSTION from each Grate Bar being entirely taken care of in the Section directly above it, the same Ratio of GRATE Surface, FIRE Surface and FLUE Area is always maintained. Note how Gases Expand at three different points.
'
;
! i i
j '
! ,:
i
Smokeless Boiler with the Lowest Water Line
Boiler No.
Steam Rating
Water Rating
20- 5 20- 6
20- 7 20- 8 20- 9
30- 6 30- 7 30- 8 30- 9
30-10 30-11 30-12
40- 8 40- 9 40-10 40-11
40-12 40-13
40-14 40-15 40-16
40-17 40-18 . 40-19
40-20 40-21
40-22 to
40-32
600 800*
1000 1200 1400
1600 2000 2400 2800
3200 3600 4000
4200 4900 5600
6300 7000 7700
8400 9100 '
9800 10500
11200 11900 12600 13300
14000 700
21000
Add per Section.
1000 1300
1650 2000 2350
2600 3250 3900
4550 5200 5850
6500 6720 7840
8960 10080 11200 12320 13440
14560 15680
16800 17920
19040 20160 21280
22400
1120 33600
Crate Surface Sq. Ft.
2.50 3.33 4.17 5.00 5.84 5.00 6.25 7.50 8.75 10.00 11.25 12.50 10.00 11.66 13.33 15.00 16.66 18.33 20.00 21.66 23.33 25.00 26.66 28.33 30.00 31.66 33.33 1.67 50.00
Flue Area Through
Sections
Sq. In.
1 Kv Steam per Hour
B.t.u. per Hour
42 150 145,500
56 200 194,000
70 250 242.500
84 300 291,000
98 350 339,500
80 400 388,000
100 500 485,000
120 600 582,000
140 700 679,000
160 800 776,000
160 900 873,000
200 1000 970,000
160 1050 1,018,500
185 1225 1,188,250
210 1400 1,358.000
235 1575 1,527,750
260 1750 1,697,500
285 1925 1,867,250
310
2100
2,037,000
335
2275
2,206,750
360
2450
2,376,500
385
2525
2,546,250
410
2800
2,716,000
435
2975
2,885.750
460
3150
3,055,500
485
3325
3,225,250
510
3500
3,395,000
25 175 169,750
760
5250
5,092,500
Height Water
line
Flow Openings
42' 42' 42' 42' 42' 42' 42' 42' 42' 42' 42' 42' 46' 46' 46' 46' 46'46' 46' 46' 46' 46' 46' 46' 46' 46' 46' _
46'
2-3' 2-3' 2-3' 2-3' 3-3' 2-4' 2-4' 2-4' 2-4' 3-4' 3-4' 3-4' 2-5' 2-5' 2-5' 2-5' 3-~^ 3-5' 3-5' 3-5' 3-5' 4-5' 4-5' 4-5' 4-5' 4-5' 4-5'
6^5'
336
Boilers
Kewanee 5?iler Company
Kewanee, Illinois
BRANCHES IN ALL PRINCIPAL CITIES
Steel Heating and Power Boilers, Water Heating Garbage Burners, Tabasco Heaters, Tanks and Radiators
KEWANEE THr&BX
Kewanee Firebox Boilers represent 35 years of
Ron cd .
"
intensive study and effort to make the highest
D9IutR-#ncA-eef-/or Heating grade equipment for heating buildings. They are
adapted to the burning of any grade of fuel and will
maintain high efficiency when operating to supply the variable demands of a
heating load.
Kewanee Smokeless
BOILER -Portable-far Heating
The rated capacity is the amount of direct radiation that the boiler will carry with a firing interval of three to four hours depending upon the
grade of fuel used. No discount in rating is ad
vised as reserve capacity has been allowed to care for the most severe weather
conditions.
Kewanee Boilers are built of steel (riveted) using as a minimum basis the rules of construction adopted by the American Society of Mechanical Engineers, known as the A. S. M. E. Boiler Code.
Ratings
The rated capacity of Kewanee Boilers, as shown, is the number of square feet
of direct radiation or equivalent which the boiler will carry, if sufficient radiation is installed to heat the building to 70 degrees fahrenheit.
The ratings are based on a standard for steam of 2 lb. pressure at the boiler, and for water on a mean temperature of 180 deg. fahr. as the water leaves the boiler.
337