Document B8Gp3NdqwEQMK9rb7b5ebK3mw
Air Conditioning
Campbell Heating Co.
3121 Dean, Des Moines 17, Iowa
WINTER-CHASER AIR CONDITIONING SYSTEMS
EASTERN REPRESENTATIVE! Neil Adams* 22 JsSsrsos St., Lflinbcrtiiile, N. J. TeL No> EX 7-06t>5
HEAVY DUTY HEATERS
For Large Churches, Schools, (Up to 3,000,000 Btu)
Commercial & Industrial Buildings
Gas
75 F Heating Guarantee
If the heating plant design is approved by our Engineering Department or de signed by a Registered Engineer and the heater and blower are furnished by us and are in accordance with our ratings, we will guarantee the heating of all rooms to which warm air is delivered to 75 F in the coldest and windiest weather.
10 Year Durability Guarantee
All Campbell Heaters installed as de scribed above are guaranteed for 10 years against repairs from any cause, parts to be furnished free f.o.b. the factory. Motor, humidifier, automatic burner and controls and other parts not manu factured by us carry their manufactur ers' guarantee of one year against de fects.
Engineering Service
Our Engineering Department will be glad to help the consulting engineer or architect solve any heating, ventilating or air conditioning problems or help with layouts and specifications for any large building. Our Engineering Department consists of trained graduate engineers backed by 73 years of practical experi ence.
Horizontal Unit Heater Oil cfc Gas Lo-Boy OH <fc Gas Fired 8000 Series For All Fuels
Campbell Heating Co.
AIT
Lonaittomng
Industrial Heating; Direct-Fired Heaters
SPECIFICATIONS and DIMENSIONS
Normal cfm 140* Dischg. Temp.
Unit No.
HEATER
Btu
Output Capacity
BTU/
Hr. f
Heating Surface
Sq Ft
per
Sq Ft Heat
ing Sur
face
BLOWERI
MAX. FUEL RATES DIMENSIONS
Assumed External Motor Oil Static In. hp gph
Water
1000 Btu
Gas cfh
LP Gas gph
Coal
Lbs Per
H In.
L in. W in.
Hr.
HI Boy & Horizontal Unit Heater--Oil & Gas for Churches, Schools, Commercial & Industrial Buildings
U225 U275
225,000 275,000
84 2700 2750 84 3300 3350
U325 U4Q0
325,000 121 2700 4000 400,000 121 3300 4900
U500 U600
500,000 182 2750 6100 600,000 182 3300 7300
U700 U800
700,000 244 2850 8500 -800,000 244 3300 9800
U950
950,000 334 2850 11,600
U1100 1,100,000 334 3300 13,500
U1300 1,300,000 455 2850 16,000
U1500 1,500,000 455 3300 18,500
\_
h H H
H
H a
H 44 M M
h 2.0 2.5
a 2.9 1 3.6
1 4.5 m 5.4
2 6.2 2 7.2
3 8.5 3 9.8 3 11.6 5 13.4
280 350
400 500
625 750
875 1000
1200 1375 1625 1875
2.8 3.5
4.0 5.0
6.3 7.5
8.8 10.0
12.0 13.8 16.3 18.8
66 66
72 72
84 84
99 99
108 108 126 126
48 48
54 54
60 60
78 78
96 96 114 114
23 23
29 29
34 34
40 40
48 48 54 54
Lo Boy Oil & Gas Fired for Large Residences, Small Churches, Schools, etc.
H200 H250 H300
H350 H400 H500
H600 H700
235,000 100 2350 2600 275,000 125 2200 3300 340,000 136 2500 4000
400,000 152 2600 4600 450,000 167 2700 5300 500,000 200 2750 6600
650,000 240 2700 8000 750,000 280 2700 9200
H H H
H h H
H H
2.1 293 2.9 44 2.5 344 3.4 44 3.0 425 4.2
1 500 5.0 H4 4.0 560 5.6 m 4.5 625 6.2
2 5 8 810 8.1 2 6.7 940 9.4
52 75 57 85 61 87
61 87 61 87 74 91
76 97 72 104
41 41 50
50 50 60
60 80
8000 Series Oil, Gas, Stoker or Hand Fired For Large Schools, Churches, etc.
8075 840,000 280 3000 11,000 8100 960,000 320 3000 12,500 8125 1,080,000 360 3000 14,100
H H M
3 7.5 1050 10.5 100 93 134 76 3 8.6 1200 12.0 114 95 153 76 3 9.7 1350 13.5 129 97 171 78
8150 1,320,000 440 3000 17,300 8i 1,440,000 480 3000 18,900
1,800,000 600 3000 23,600
8250 8300
2,250.000 750 3000 29.500 2.700.000 900 3000 35,400
3,150,000 1050 3000 41,300
M 44 H
?< W H
5 11.8 5 12.9 5 16.1
744 20.1 7H 24.1 10 26.1
1650 1800 2250
2810 3380 3940
16.5 18.0 22.5
28.0 33.8 39.4
157 171 214
268 320 375
98 195 99 202 120 216
120 243 132 251 150 251
76 76 94
94 104 114
Type A unita include Special Oil or Gaa Heater, Casing, Blower, Motor, Drive, Filters, Humidifier, and
Blower Control but less Burner, Controls and Built-in Combustion Chamber.
Type B unita include same as Tybe A dIus Oil or Gas Burner and built-in Combustion Chamber and Standard Controls.
t Based on 80% thermal efficiency for oil and gas and 70% for coal. Add 10% to 35% over calculated heat
loss for pick-up load and 10% to 15% for duct radiation losses. The higher figure is preferable for best operat-
11?* economy and life of the equipment.
_
* r or other air volumes and static pressures consult our Engineering Department.
* An induced draft blower can be furnished if a stack or chimney is not available. The gas passages of the
oeaters are adequate so an induced draft blower is not ordinarily needed.
For Complete Specifications, See Sweet*s Catalog Service 85