Document B8Gp3NdqwEQMK9rb7b5ebK3mw

Air Conditioning Campbell Heating Co. 3121 Dean, Des Moines 17, Iowa WINTER-CHASER AIR CONDITIONING SYSTEMS EASTERN REPRESENTATIVE! Neil Adams* 22 JsSsrsos St., Lflinbcrtiiile, N. J. TeL No> EX 7-06t>5 HEAVY DUTY HEATERS For Large Churches, Schools, (Up to 3,000,000 Btu) Commercial & Industrial Buildings Gas 75 F Heating Guarantee If the heating plant design is approved by our Engineering Department or de signed by a Registered Engineer and the heater and blower are furnished by us and are in accordance with our ratings, we will guarantee the heating of all rooms to which warm air is delivered to 75 F in the coldest and windiest weather. 10 Year Durability Guarantee All Campbell Heaters installed as de scribed above are guaranteed for 10 years against repairs from any cause, parts to be furnished free f.o.b. the factory. Motor, humidifier, automatic burner and controls and other parts not manu factured by us carry their manufactur ers' guarantee of one year against de fects. Engineering Service Our Engineering Department will be glad to help the consulting engineer or architect solve any heating, ventilating or air conditioning problems or help with layouts and specifications for any large building. Our Engineering Department consists of trained graduate engineers backed by 73 years of practical experi ence. Horizontal Unit Heater Oil cfc Gas Lo-Boy OH <fc Gas Fired 8000 Series For All Fuels Campbell Heating Co. AIT Lonaittomng Industrial Heating; Direct-Fired Heaters SPECIFICATIONS and DIMENSIONS Normal cfm 140* Dischg. Temp. Unit No. HEATER Btu Output Capacity BTU/ Hr. f Heating Surface Sq Ft per Sq Ft Heat ing Sur face BLOWERI MAX. FUEL RATES DIMENSIONS Assumed External Motor Oil Static In. hp gph Water 1000 Btu Gas cfh LP Gas gph Coal Lbs Per H In. L in. W in. Hr. HI Boy & Horizontal Unit Heater--Oil & Gas for Churches, Schools, Commercial & Industrial Buildings U225 U275 225,000 275,000 84 2700 2750 84 3300 3350 U325 U4Q0 325,000 121 2700 4000 400,000 121 3300 4900 U500 U600 500,000 182 2750 6100 600,000 182 3300 7300 U700 U800 700,000 244 2850 8500 -800,000 244 3300 9800 U950 950,000 334 2850 11,600 U1100 1,100,000 334 3300 13,500 U1300 1,300,000 455 2850 16,000 U1500 1,500,000 455 3300 18,500 \_ h H H H H a H 44 M M h 2.0 2.5 a 2.9 1 3.6 1 4.5 m 5.4 2 6.2 2 7.2 3 8.5 3 9.8 3 11.6 5 13.4 280 350 400 500 625 750 875 1000 1200 1375 1625 1875 2.8 3.5 4.0 5.0 6.3 7.5 8.8 10.0 12.0 13.8 16.3 18.8 66 66 72 72 84 84 99 99 108 108 126 126 48 48 54 54 60 60 78 78 96 96 114 114 23 23 29 29 34 34 40 40 48 48 54 54 Lo Boy Oil & Gas Fired for Large Residences, Small Churches, Schools, etc. H200 H250 H300 H350 H400 H500 H600 H700 235,000 100 2350 2600 275,000 125 2200 3300 340,000 136 2500 4000 400,000 152 2600 4600 450,000 167 2700 5300 500,000 200 2750 6600 650,000 240 2700 8000 750,000 280 2700 9200 H H H H h H H H 2.1 293 2.9 44 2.5 344 3.4 44 3.0 425 4.2 1 500 5.0 H4 4.0 560 5.6 m 4.5 625 6.2 2 5 8 810 8.1 2 6.7 940 9.4 52 75 57 85 61 87 61 87 61 87 74 91 76 97 72 104 41 41 50 50 50 60 60 80 8000 Series Oil, Gas, Stoker or Hand Fired For Large Schools, Churches, etc. 8075 840,000 280 3000 11,000 8100 960,000 320 3000 12,500 8125 1,080,000 360 3000 14,100 H H M 3 7.5 1050 10.5 100 93 134 76 3 8.6 1200 12.0 114 95 153 76 3 9.7 1350 13.5 129 97 171 78 8150 1,320,000 440 3000 17,300 8i 1,440,000 480 3000 18,900 1,800,000 600 3000 23,600 8250 8300 2,250.000 750 3000 29.500 2.700.000 900 3000 35,400 3,150,000 1050 3000 41,300 M 44 H ?< W H 5 11.8 5 12.9 5 16.1 744 20.1 7H 24.1 10 26.1 1650 1800 2250 2810 3380 3940 16.5 18.0 22.5 28.0 33.8 39.4 157 171 214 268 320 375 98 195 99 202 120 216 120 243 132 251 150 251 76 76 94 94 104 114 Type A unita include Special Oil or Gaa Heater, Casing, Blower, Motor, Drive, Filters, Humidifier, and Blower Control but less Burner, Controls and Built-in Combustion Chamber. Type B unita include same as Tybe A dIus Oil or Gas Burner and built-in Combustion Chamber and Standard Controls. t Based on 80% thermal efficiency for oil and gas and 70% for coal. Add 10% to 35% over calculated heat loss for pick-up load and 10% to 15% for duct radiation losses. The higher figure is preferable for best operat- 11?* economy and life of the equipment. _ * r or other air volumes and static pressures consult our Engineering Department. * An induced draft blower can be furnished if a stack or chimney is not available. The gas passages of the oeaters are adequate so an induced draft blower is not ordinarily needed. For Complete Specifications, See Sweet*s Catalog Service 85