Document B8BnQEn3b6pbaLZ7bjxwBBezw

388 CHAPTER 16 1954 Guide are considered consistent with good practice, although there are boilers; which have high efficiencies and also operate at higher 'transmission, rates. TESTING AND RATING CODES The Society has adopted four solid fuel testing codes, a solid fuel rating code, and an oil fuel testing code. ASHVE Standard and Short Form Heat Balance Codes for Testing' Low-Pressure Steam Heating Solid Fuel Boilers--Codes 1 and 2--(Re vision of June, 1929),1 provide a method for conducting and reporting^ tests to determine heat efficiency and performance characteristics. ASHVE Performance Test Code for Steam Heating. Solid Fuel Boilers --Code No. 3--(Edition of 1929)1 is intended for use with ASHVE Code* (withdrawn in 1953) for Rating Steam Heating Solid Fuel Hand-Fireij Boilers.2 The object of this test code is to specify the tests to be conducted)! and to provide a method for conducting and reporting tests to determine the efficiencies and performance of the boiler. ,, The ASHVE Standard Code for Testing Steam Heating Boilers Burning Oil Fuel,3 (Adopted June, 1932), provides a standard method for con ducting and reporting tests to' determine the heating efficiency and per formance characteristics when oil fuel is used with steam heating boilers'!' The ASHVE Standard Code for Testing Stoker-Fired Steam Heating. Boilers,4 (Adopted June, 1938), provides a test method for determining' the efficiency and performance characteristics of any stoker and boiler combination burning any type of solid fuel, such as anthracite or Bi tuminous coal. ; * f:-lL The Steel Boiler Institute, Inc. has adopted a Rating Code for Com-; mercial Steel Boilers and Residential Steel Boilers, and for Testing OilFired Residential Steel Boilers (Fifth Edition as Revised Jan. 1, 1948)) The commercial boilers (defined as those having 129 to 2500 sq ft of heating surface) are rated in square feet (steam) on the basis of heating surface with limitations set for grate area, furnace volume, and furnace heigh)-' Table 1. SBl Net Rating Data, for Residential Steel Boilers--Oil Fired* -Sq Ft Steam 275 320 400 550 700 900 1100 1300 1500 1800 2200 2600 3000 SBI .Net Rating Sq Ft Water 440 510 640 880 1120 1440 1760 2080 2400 2880 3520 4160 4800 Btu 66000 77000 96000 132000 168000 216000 264000 312000 360000 432000 528000 624000 720000 Minimum Furnace Volume Cu 2.5 2.9 3.6 5.0 6.4 8.2 10.0 11.8 13.6 16.4 2o;o 23.6 27.3 Heating3 Surface Sq Ft;$. 16 19 AS 24 32; >ll-V 41- -i?r 53.l,T!h 65 88.i`f i29;!i 153 f. 177.-.; *? B Stoker-fired and Gas-fired SBI Net Rating not greater than Oil-fired. Hand-fired, SBJ Nek` , (Steam) not greater than 14 times the square feet of beating surface. foh C o m m e r c ia l- St e e l B o ile r s Heating Boilers, Furnaces, Space. Heaters 389