Document B89vbYMq1n8B0mJNbNMOp1XYj
;i; ; tj |;
fi
![i:
I !
I i' I
166
CHAPTER 8
1952 Guide
/ -
Analytical Chemistry of Industrial Poisons, Hazards and Solvents, by M. B.
Jacobs (Interscience Publishers, New York, 1941). Bibliography of: Industrial Hygiene, 1900-1943 {TJ. S. Public, Health Service Bul
letin No. 289, 1945).
-.
Clouds and Smokes, by W: E. Gibbs (P. Blakiston's Son & Co., Philadelphia, Pa.,
1924).
---.
Determination and Control of Industrial Dust, by Bloomfield and DallaValle
(U. S. Public Health Service Bulletin No. 217, 1935). Dust, by S. C. Blacktin (The Sherwood?Press, Cleveland, 1934).
(The) Environment and Its Effect upon Man (Harvard School of Public Health,
Bo. sIntodnu, s1t9ri3a7l)D. ust, by Drinker and Hatch.(McGraw-Hill Book Co., New York, 1936). Industrial Health Engineering by A. D. Brandt (John Wiley & Sons) Inc., New
YorInk,du19s4tr7i)a. l Hygiene and Toxic.olo\gy, edited by F. A.. Patty (Interscience Publishers,
Inc., New York, Vol. I, 1948 .and Vol. II, 1949). Journal of Industrial Hygiene and Toxicology (monthly) (Harvard School of
'Public Health, Boston, Mass.). See cumulative abstract and subject indexes.
Manual of Industrial Hygiene, by W. M. Gafafer, et al {U.S. Public Health Service,
W. B. Saunders Co., Philadelphia, 1943).
-
Noxious Gases and the Principles of Respiration Influencing Their Action, by Hen
derson and Haggard (American Chemical Society Monograph Series No. 35, Reinhold,
New York, 1943).. Occupation and Health, two volumes {International. Labor Office, Washington,
D.CTo.)x.icology and Hygiene of Industrial Solvents, by Lehmann and Flury, trails' lated by Eleanor King and H. F. Smyth, Jr. (Williams and Wilkins, Baltimore, 1943)-
J
CHAPTER 9
HEAT TRANSMISSION COEFFICIENTS OF BUILDING MATERIALS
Heat Transfer Symbols; Calculating Overall-Coefficients; Conductivity of Homo geneous Materials; Soil Conductivity; Surface Conductance; Air Space Con ductance; Practical Coefficients and Their Use; Computed Coefficients of Walls, Roofs) Ceilings and Floors; Combined Ceiling and Roof Co efficients; Calculating Surface Temperatures; Water Vapor and Condensation; Vapor Transmission; Condensation Control
THE design of air conditioning or heating systems for buildings requires a knowledge of the thermal properties of the walls enclosing the space. (The term walls in this case, includes windows,' doors, ceilings, floors, roofs and skylights). The rate of heat flow through the walls'under steady-state conditions at design temperatures is usually the basis for calculating the heat required. For a given wall under standard conditions the rate is a specific value designated as U, The. overall coefficient of heal transmission. It may be determined by test in a guarded, hot box apparatus, or it may be computed from known values of the thermal conductance of the various components. Because testing of all combinations of building materials is impracticable, the procedure and necessary data for calculation of the value of U are given in this chapter, together with tables of computed values for the more common constructions.
HEAT TRANSFER SYMBOLS
U = overall coefficient of heat transmission (air to air); the time rate of heat flow expressed in Btu per (hour) (square foot) (Fahrenheit degree temperature difference between air on the inside and air on the outside of a wall, floor, roof or ceiling).' The term is applied to the usual.combinations of materials, and also to single materials, such as window glass, and includes the,surface conductance on both sides.
k = thermal conductivity; the time rate of heat flow through a homogeneous mate rial under steady conditions through unit area per unit temperature gradient in the direction perpendicular to the area. Its value is expressed in Btu per (hour) (square foot) (Fahrenheit degree per inch of thickness). Materials are considered homogene ous when the value of k is not affected by variation in thickness or size of sample within the range normally used in construction.
C = thermal conductance; the time rate of heat flow through a material from one of its surfaces to the other per unit temperature difference between the two surfaces. Its value is expressed in Btu per (hour) (square foot) (Fahrenheit degree). The term 8 applied to specific materials as used, either homogeneous or heterogeneous.
f = film or surface conductance; the time rate of heat.flow between a surface and the surrounding air. Its value is expressed in Btu per (hour) (square foot of surface) (Fahrenheit degree temperature,difference). Subscripts! and o are used to differen tiate between inside and outside surface conductances, respectively.
a = thermal conductance of an air space; the time rate of heat flow through an air space per unit temperature difference between the boundary surfaces. Its value is ex pressed in Btu per (hour) (square foot of area) (Fahrenheit degree). The conduct ance of an air space is dependent on the temperature difference, the height, the depth, the position and the character of the boundary surfaces.: The relationships are not hnear, and accurate values must be obtained by test and not by computation.
R = thermal resistance. Its value is obtained from the reciprocal of heat transJsr as expressed .by U, k, C, f or a. It is expressed in (hours) (square feet) (Fahren heit degrees) per'(Btu), For example, a wall with a TJ value of 0.25 would have a
'167 ' '