Document B5w5EL0zrm3GXZD38rO7RezDJ

Ford Marketing Corporation Ford Cuiom*r Sarvfca Dlviaion `., . 'f .. . ' Sarviea Aaaaarsh Cantar , 1S7S1 Oakwood B)vd Oaartom, Mtehlgan *8121 1 June 10, 1975 Mr, Jack Doyla Doyle Vacuum Cleaner Company 225 Stavsps Street . Grand Rapids, Miohlgan 49532 Dear Jack: This la in regard to the Rotunda^Joyla-asbestos duat vacuum cleaner projsot, The prototype unit model AARE 705-^75 aerial number 1027 submitted far fiber emission testing conforms to current OSHA Threshold Limit Values TLV. Our tests also reflect compliance with the two fibers greater than five microns in length per milliliter requirement scheduled for OSHA implementation July 1, 197^< All testa were performed according to OSHA regulations by the University of Cincinnati Medical Center, 3223 Eden Avenue, Cincinnati, Ohio 45219. As you requested, we have encloeed a copy of the test data. On the basis of our teat, the vacuum cleaner model AARE 705-475 when properly maintained would be acceptable from a fiber emission standpoint for use in the cleaning of duat from brake or clutch assemblies. However, ve recommend that Doyle continue to test production units on a lot sample basis. Our contact at the University of Cincinnati's Kettering Laboratory* ie Dr. Dave Yeager, Assistant Professor Environmental Health, telephone (513) 672-5700. In regard to the "caution label", Ford Office of the General Counsel advises that the heading should read as follows; CAUTION CONTAINS ASBESTOS FIBERS AVOID CREATING DUST BREATHING ASBESTOS DUST MAI CAUSE SERIOUS BODILY HARM ` A revised label should be provided for review by our Legal Department. 002765 PRODUCED BY FORD 105478 ! Mr. Jack Doyle June 10, 1975 .Page 2 We have reviewed your letter and quotation of Kay 30* 1975. Ford Motor Company ia not in the position to oancur with the terms as set forth in the first paragraph of Doyle1 a proposal under the heading Warranty . Information for Rotunda Vacuum Cleaner Model No. AARE 705^76* Ford Rotunda's standard liability clause would apply. This has bean reviewed with our contract attorney, Mr. G. D. Ducharme. He is prepared to further clarify Ford'a position and can be reached on telephone (313) 323-0123. In addition, Ford Rotunda's Performance Specification for the vacuum cleaner model AARS 705-^75 requires that the unit meet all present and future OSHA standards including the QSHA TLV scheduled for July 1; 1976. This requirement should be incorporated in the specifications submitted with your quotation. We hope that we have been of assistance and look forward to your reply. G. D, Ducharme O. M. Julian P. J, Keegan W, Rooney S. F, Svoboda i 002766 PRODUCED BY FORD