engineering HEAT TRANSFER DATA for use with -- litowsoti) ____iVi- 0509277 If a fire-resistant, heat-transfer agent that operates up to 600" !. in the liquid phase w TOWOLDMONOQ34581 ......................... has been used successfully since 1941 as a liquid phase heat transfer medium at atmospheric pressure and temperatures up to 600F. The compound, essentially tetrachlorobiphenyl, is a fire-resistant and non corrosive liquid, which does not crystallize at low temperatures. Handled properly, in well-designed forced circulation heat exchangers which avoid localized over heating damage, the fluid gives satisfactory continuous service for many years without replacement. Most significant, Aroclor 1248 is practically non-flammable. In one in stallation of record, a ruptured pipe that spewed the hot fluid into gas flames failed to cause the fluid to ignite. For general heat transfer, Aroclor 1248 has several other important qualities: it is highly mobile and can be readily pumped at temperatures as low as 50F. If cooling is necessary, the heat transfer fluid can be put through a water cooler to be used as a coolant... using this single fluid for both heating and cooling. Aroclor 1248 transfers heat (up to 600"F.) as a liquid. This liquid phase heat transfer makes it unnecessary to use the expensive pressurized equipment required by a heat transfer medium that operates as a vapor. Aroclor 1248 operates safely and efficiently with gas-fired, oil-fired, or electrical heat sources. It is used successfully in the following types of applications .... Chemical Processing Equipment, particularly for reacting flammable materials Cooking of Alkyd resins, varnishes, waxes Plastics molding, extruding, calendering Rubber processing Heating asphalt Food Processing, including potato chip and doughnut frying in vegetable oils Processing titanium, magnesium, other non-ferrous metals Fabrication of magnesium and aluminum honey-comb structures for aircraft Indirect heating in dyestuff manufacture Heating of corrugating rolls ,, Indirect heating of distillation equipment Saponification of fats Calcining Ovens Impregnation and lamination of fibrous materials b iZbS TOWOLDMONOQ34583 jl)iihV!Hf nil! I! " ` ! IClMjiU'' 11 V AROCLOR 1248 uLiL 05092BO Appearance : Absolute density, g./ml. Absolute viscosity, centipoises Thermal Conductivity, Btu./hr.sq. ft/T./ft Spec. Volume, ml./g. Practically colorless mobile liquid. Temperature "Centigrade "Fahrenheit 1.44 30 86 1.41 60 140 1.37 100 212 1.27 200 392 1.17 300 572 112.0 30 86 17.5 60 140 4.2 100 212 0.99 200 392 0.47 300 572 0.0571 30 0.0564 60 0.0555 100 0.0534* 200 0.0512* 300 * Extrapolated Data. 86 140 212 392 572 0.696 30 0.709 60 0.728 100 0.787 200 0.860 300 86 140 212 392 572 Table 1 TOWOLDMONOQ34584 . (Table 1, cont.) Spec. Heat, cal./g./C. Vapor Pressure, mm. Hg. 0183 0.297 0.326 0.355 0.00037 0.16 2.9 18.0 350.0 'Centigrade 50 100 200 300 37.8 100 150 200 300 'Fahrenheit 122 212 392 572 100 212 302 392 572 Distillation Range, ASTM D-20 345-385 652-725 Flash PL, Cleveland Open Cup, ASTM D 92-45 193-196 379-384 Fire Pt., Cleveland Open Cup, ASTM, 0 92-45 Pour PL, ASTM, 0-97 _ None -- -- -7 19.4 Average Coefficient of Expansion cc./cc./F. x rc CrP* 0.00037 0.00038 0.00041 0.00044 0.00047 0.00052 -17.8 to 37.8 37.8 to 93.3 93.3 to 149 149 to 204 204 to 260 260 to 316 0 to 100 100 to 200 200 to 300 300 to 400 400 to 500 500 to 600 4 PHYSICAL ? CHARACTERISTICS of AROCLOR 1248 A complete knowledge of the physical characteristics of heat transfer media is highly essential to their satisfactory application in a heat exchanger. These physical constants have a major bearing on the equipment design, its mainte nance, and its operation. The following figures and charts give basic physical data on Aroclor 1248. V TOWOLDMONOQ34585 DENSITY OF AROCLOR 1248 (Top axis, Ibs./cu. ft.; bottom axis, r CO O o -r* o TEMPERATURE * f . TEMPERATURE F. I s TOWOLDMONOQ34586 VISCOSITY O F AROCLOR 1248 VISCOSITY UNITS TEMPERATURE *F. 0509283 TOWOLDMONOQ34587 VISCOSITY OF AROCLOR 1248 ;(Saybolt |U.1n. i,veMrsal Seconds) IN* O' m o VISCOSITY, SAYBOLT UNIVERSAL SECONDS `30 -20 Figure 3 0 20 40 GO 80 100 120 140 160 180 200 220 240 260 280 300 320 340 350 TEMPERATURE, DEGREES FAHRENHEIT ,"1 ""Iiimi in V11:.11 i ,|A TOWOLDMONOQ34588 HEAT CAPACITY and Zts Relationship to Density Systematic errors exist in the various accepted pro cedures for making specific heat determinations. Consequently values may vary depending upon the procedure used. In practical operation, it frequently appears that the values for Aroclor 1248 shown in Figure 4 are somewhat low. Consequently, although these values have been accurately determined, they may be regarded as conservative. When comparing the specific heat values of Aroclor 1248 with corresponding values for other heat transfer fluids, it is important to note that the density of Aroclor 1248 is much higher relatively than the density of other liquids used for heat transfer. Accord ingly, when comparison of heat capacity is made on a volume basis (which is most pertinent in equipment design and efficient operation) the heat cji|wcity of Aroclor 12-18 shows itself to better advantage than by direct comparison of specific heat values. Although specific heat values are important, they represent only one of several important constants that enter into the equations for calculating over-all heat transfer efficiency. Through the use of these conservative heat capacity values, it is possible that equipment engi neered from such data might be slightly "over designed." It may be one of the factors that accounts for the exceptionally good operating performance of a number of highly successful commercial applications. TOWOLDMONOQ34589 QSO'iZ b b p l . I. -- l.l Ml.. -- SPECIFIC HEAT OF AROCLOR 1248 (Btu. per lb. per degie F.) I l'|l 'I'll................. ... I ' " ............... ...................... ' p111 I1'! 1 r'i * -ci ' i11 ' i"":" ;. L' -f'N;'- '!' '!' '".;i 1........ *-l.` " -i11 mi rKr'-v ; }............... : l ,r ............. I "`"M I'" lirt(, I ,, 'ill., i.j I:., ...'I 1 . ' i' "I N .. . . -- 1........... ""'I i "Hip" "I 111 111..i.111j :,j || ipi..|j . ,i ....... 1......... . 1 'I Tf r' ............................. . >* >' >" - -H -I -'SiJ x- rt-U-1!!!! 1" ..... ....... M|T> rr n. . i--m "ii "'I"'"1 ` -i . ' " " ." ' -............. ... I T'%^ I ' >i 1 >"> ( -|....... ' - ... j KM"": !}!) .!!( 'V ' ' i1 I !' ............... i............. ,1 T"Sy!: '!! "`i` '' " 1 "`'I I !'l1' li " '! I. mNsJM'V"''.- I-I ! 'll ."ii " 1 ' |. i' ' .i '' ''' 1, '' . . .'n1 ! "i : <! (-........- ' j'1'1................. '* " 'I ''l 1 "I , i I-i li- v" M M!\ ,1111 IJI l'H\. ll\, ...i.i,, [' | ` 'll'-'* -i, [ ^ ..... ' ' [. !** I ! I t ' ' ' .. \ ...... . " ' . |_____., . _______________________ . ------ ...___________ ___ _____ ,.i. ... .1 ,, -- 0.37 036 0.35 034 0.33 0.32 031 Figure 4 SPECIFIC HEAT Btu./lb./"F. ---- .------------.-- 030 0.29 :~J 600 i 500 5 * 100 1I TOWOLDMONOQ34590 r -I Ii i s <5 A is 10 i iezt> 05 Temperature C. F. 0 32 10 50 38 100 66 150 93 200 121 250 149 177 ' 204 232 260 288 316 300 350 400 450 500 550 600 HEAT CONTENT of Aroolor 1248 Specific Heat Btu./lb./F. .269 .272 .280 .288 .295 .303 .311 .319 .327 .335 .343 .351 .359 Heat Content Btu./lb. 0.0 4.85 18.65 32.85 47.43 62.38 77.58 93.48 109.66 126.21 143.17 160.52 178.27 TOWOLDMONOQ34591 /w.-'l * THERMAL CONDUCTIVITY ; IM ; and VISCOSITY ; I'.i ; <6 rM <? OX' Mui n-v i *'Tht thermal conductivity values of Aroclor 1248 are shown in Figure 5. The curve shows this value over Aroclor 1248's operating temperature range, from lil50oF. to600F. I < ! Although Aroclor 1248 tends to darken in use, this darkening is not harmful and does not indicate decomposition. In actual use at Monsanto, it has not , As freshly charged into a heat exchanger, Aroclor 1248 has an initial viscosity of 74 (S.U.S.) at /.'< 130F. which corresponds to a viscosity^ of approxi^mately 5000 (S.U.S.) at 50F. -- which temperature is been found necessary to replace the fluid after seven years of continuous use; additional fluid is only added as necessary to make up spills or leaks. assumed for practical purposes to be about the limit at | In Figure 6, the horizontal line indicating vis . which Aroclor 1248 can be conveniently pumped with a centrifugal pump. cosity limit of ptimpability at 50F. shows that the * ' ' 1 The following table shows a comparison of the rate of viscosity* increase based on a year's continuous i Yoipitial yiscosity and the viscosity after a year's con ! service should permit Aroclor 1248 to serve approxi ! tinuous service at 60QF. in a LaMont forced circu- 1 lation heater: '' mately four years before increased viscosity may inter * i'>` i > . m Appearance Specific Gravity, 65 C. TABLE III Original Ii ,> -jj After one Year of service at 600F. Colorless Liquid 1.410 park Brown Liquid, 1.418 fere with its pumpability when cold. In practice, Aroclor 1248 has given' satisfactory pumpability for much longer periods. A simple S.U.S. viscosity deter mination by the ASTM-D-88 method can be used for Viscosity, S.U.S. at 130F. 74.0 83.5 periodic checks on the fluid. . TOWOLDMONOQ34592 THERMAL CONDUCTIVITY OF AROCLOR 1248 (Dotted extension indicates extrapolated data) TOWOLDMON0034593 VISCOSITY, SAYBOLT SECONDS, i t 130" F. EXPECTED MINIMUM SERVICE LIFE IN A FORCED CIRCULATION HEATER TOWOLDMONOQ34594 STABILITY Aroclor 1248 Is an extremely stable chemical com pound. Tests over long periods of time have shown that 600F. is a safe maximum temperature for continuous operation in heaters that are properly designed and operated to eliminate intense, localized overheating. At this temperature the fluid is 52F. l>elow the initial temperature of its boiling range, and consequently re mains a liquid. Near its boiling point Aroclor 1248 tends to dehydrohalogenatc to a very slight but measurable degree. If this occurs as a result of accidental over heating, the small amount of HC1 gas evolved tends to pass through the vent tank without harm to the equipment provided that the system is dry. Experimental observations using ideally-suited heat exchangers operating at a temperature of 650F. with imposed nitrogen pressures of 30 and 70 psig. showed that application of pressure did not prevent this small amount of thermal decomposition, which also occurs when the material is heated above 600CF. at atmospheric pressure. When heated continuously at 650F. under nitrogen pressure a gradual increase in the viscosity of the fluid occurs indicating that its service life would be limited to about 6 months to one year. Ucsults of operating at 600nF,, however, with out imjxised nitrogen pressure indicate Aroclor 1248 can be lieated continuously at this temperature for about 4 years before any viscosity increase could be expected to interfere 'with' its pnmpahility at 50 F. which is slightly IhjIow normal room temi>eratiires. Provision should be made to prevent water contamination of the system. If the system becomes contaminated with water, any MCI hl>erated by local ized overheating may dissolve in the water film which will float on top of Aroclm 1248 in the expansion tank. The acidic solution thus formed can cause corrosion. It is recommended that moisture lx* eliminated from the expansion tank by installing a moisture trap or by sealing the tank and applying 15 to 30 psig. of nitrogen gas. With exception of the expansion tank, the system should be kept full of Aroclor 1248 at all times to pre vent formation of air pockets where moisture may condense when the system cools off Iwtween periods of operation. Many years of practical operating experience has shown that Aroclor 1248 is virtually non-corrosive to valves, piping, tanks, and jackets made of cast steel, steel, or stainless steel. In actual use, brass valves have been used satisfactorily. SAFETY of OPERATION Aroclor 1248 can be considered a non-flammable liquid; no fire point is obtained by the Cleveland Open Cup method on heating to its boiling point (650F.). The spontaneous ignition temperature(2) is 1,299F, In actual use, the following reported accident in a heating system demonstrates the fire resistance of Aroclor 1248 and the freedom it offers from the hazard of fire propagation. An operator's failure to start the circulation pump when the gas heater was on resulted in excessive coil temperatures. The line containing Aroclor 1248 sagged into the fire chainlx*r. A weld rup tured and Aroclor 1248 poured into the red-hot fire chainln'r in contact with the flame. Dense smoke and fumes arose from the heater but there was no external fire. After the gas flame was cut off, the smoking stopped. . Insurance authorities allow the use of Aroclor 1248 heaters in many locations with a minimum of protection. No fire walls are required to isolate the heaters. Aroclor 1248 has a low vapor pressure. In sys tems that employ a vented expansion tank, the lass due to evaporation is not measurable. If Aroclor 1248 in the expansion tank would reach a temperature of 266F., the vapor pressure of the fluid would be only l.mm, of Hg. SAFETY OF HANDLING ;' Aroclor 1248 is an inert, unreactive liquid. If it is spilled on the skin, there are no noticeable ill effects. It is advisable, however, to wash the skin with soap and water after contact. A skin burn resulting from accidental contact with hot Aroclor 1248 should be treated in the normal manner for hot oil burns. Any liquid adhering to the burned area need not be removed immediately unless treatment of the burn demands it. If the burn must be cleaned, soap and water or repeated washings with a vegetable oil (olive oil) may be used. The vapors emitted by Aroclor 1248 heated to elevated temperatures are injurious on prolonged ex posure and should not be breathed. It is indicated that 2.0 mg. of Aroclor 1248 per cubic meter of air is the maximum safe amount permissable in workrooms. In commercial heat transfer installations, it is presumed that Aroclor 1248 will he used in a closed system free from leaks. Accordingly, their should be little or no opportunity for workers to come in contact with Aroclor 1248 vapors. 0509293 I i i ; ii of a COMPLETE SYSTEM | Ite'JSIil ,! . LjVkJ 16 HEATER The most significant factor to remember when selecting or de signing a heat exchanger for Aroclor 1248 use is this: Aroclor 1248 transfers heat as a liquid, at the maximum recom mended temperature of 600F. for continuous operation, which is approxi mately 50F. below the Ixjiiing point. Consequently, Aroclor 1248 does not form vapor to accelerate convection circulation. Ordinary fire-tube or water-tul>e heaters which depend solely upon convection perform satisfactorily only at relatively low teinjx'ratures. When temperatures of 500-WK) 'F. are required, a forced circu lation type heater is recommended. A satisfactory type of heater design would consist of a specified number of tulx*s in i>aruilc], pnqx'rly orifierd to provide a high velocity fluid flow of 8 to 10 feet per second. These should be spaced to permit uniform heat absorption throughout their entire length. A typical construction is shown in Figure 7. In its fabrication, the heater should l>e ASME Code all-welded construction, conforming to state and local ordinances. Tube joints, which in an ordinary steam heater would be the expanded type, must be sealwelded to prevent leakage. All connections larger than should be flanged connections, since ordinary threaded pipe connection is not suited for Aroclor 1248 service. Spiral-wound stainless steel and asbestos com bination is recommended for sealing joints and plugs. Drain valves should be installed at all low points on the h&ter and the valves must conform with ASME requirements for "blow down** valves. TOWOLDMONOQ34597 Since a Heater operating on Arocior 1248 is completely filled with liquid, costly liquid-level controls and condensate return pipes, fittings, traps, etc. are completely eliminated. Heaters can He provided with any desired kind of firing. Portable and small size stationary are frequently electrically heated; larger units may be gas- or oil-fired. In installations where an open flame present* a fire hazard, to meet insurance requirements the heater may be installed in a separate build ing with piping carrying the hot Arocior 1248 to the point of use. Properly constructed transmission pipes may extend for hundreds of feet. HEATER EFFICIENCY Forced circulation heaters with integral economizers will show an efficiency of from 75 to 80%. Heaters of the straight con nector type show efficiencies of 65 to 75%, depending upon the discharge temperatures. HEATER CAPACITIES Heaters using Arocior 1248 (gas- or oil-fired) are available in output capacities ranging from approximately 250,000 Btu. per hour to large units rated over 10 million Btu. per hour. A heat flux density (or heat energy input) of approximately 5,000 Btu. per hour per square foot of tube surface is regarded as satisfactory. For lower output rate, electrically-heated units are favored, employing watt densities of 12 to 16 watts per square inch. t 17 TOWOLDMONOQ34598 THE USERS Tlic "users'* or recipients of the heat at the point of processing can be any type of heating pun, platen, Jacketed kettle, or coils of steel or stainless steel construction. Ordinary low pressure construction is satisfactory, since the pressure imposed on the Arnclor 1248 seldom exceeds 50 psig. In the user, however, it is important that all-welded construction be used. Threaded connections may allow leakage of the hot fluid. As in the beater, all connections and over should be flanged and all Joints sealed with spiral wound stainless steel and asbestos gasket material. Alloy bolts should he used to secure flanges. A typical system with several users is wunxm vessel WT 46Zt><>4 0 Figure 8 IS TOWOLDMONOQ34599 050S296 THE PUMP For most systems, cast-steel centrifugal pumps with watercooled stuffing box and bearings are to be preferred. However, high temperature centrifugal pumps with mechanical seals are now available which give excellent performance. In some in stallations, immersion pumps have been used. Whatever type is selected, the pump capacity and pressure head must be sufficient to circulate the volume of fluid at the rate the particular installation demands. ' To avoid shaft trouble and leakage at the seals, it is iin|)ortant to provide ad<*quato exclusion joints and to support the piping in a manner to avoid stresses on the body of the puinp. Direct-connection pumps driven by 1,750 rpm. motors are most commonly used. Each pump should be fitted with a positive differential control to switch off the burner in case of pump failure. When a new system is first put into operation, a slight leakage may l>e noticed at the pump. It is not advisable to tighten the pump gland, however, until the system has heated up close to the temperature of operation. PIPING LAYOUT The most important factors in the piping layout for Aroclor 1248 systems are (a) proper sizing for the required flow rate and (b) minimizing pressure drop, because the sys tem will undergo temperature changes, adequate expansion joints and loops to relieve expansion and contraction stress are essential. All pipe lines and connections should be of extra heavy or Schedule 80 welded construction meeting A.S.M.E. require ments. Flanged joints should be used as sparingly as possible to minimize potential leak points. All valves and controls should be cast steel construction with stainless steel seats. Pipe lines should be well insulated and those exposed to temperatures below 70F. should be steam jacketed. All high points in the piping system should be provided with vent valves; all low points should have drain connections. Piping should be well anchored at frequent intervals, particularly near expansion loops, to prevent vibrations. Figure 9 shows a typical piping diagram that illustrates the important features of an Aroclor 1248 piping system. These may be varied to suit the installation. ; i;, . ; * 19 TOWOLDMON0034600 T THE EXPANSION TANK The expansion tank should be large enough to accom modate about 20% of the total volume of the entire system, including the fluid content of the heater, piping, and all heatusers. Tank should Ik* sized to be tt-full when system is cooled to 70r'F. and %-fnll when system is at maximum operating tem perature. Expansion tank should be fitted with a sight glass at the "full" range and a float-oi>erated low-level switch to shut off burner in case of accidental fluid loss in the system. The expansion tank should be mounted on a platform high enough to sup|x>rt the licfiiid reservoir at least six feet higher than the highest point in the piping system. THE FEED and DRAIN PUMP To eliminate manual filling and draining of the heating system, it is recommended that a small 2-to-5 gpm. positive displacement pump be installed at some convenient point to pump the Aroclor 1248 into or out of the system. CONTROLS Controls for heating systems using Aroclor 1248 should be installed both on the heater itself and on the heat-using units. A wide variety of thermo-operating controls are available and any reliable standard equipment is satisfactory. Heater controls should be installed to regulate the firing mechanism in direct proportion to the required output. These controls should increase or decrease the heat in-put to main tain the Aroclor 1248 at the operating temperature required by the heat-demand of the user. Small units may be operated satisfactorily by relatively simple "on-off' or "high-low" con trollers; larger units may operate more uniformly if equipped with modulating temperature controls. User Controls should be installed to regulate the flow of the heat transfer fluid in direct proportion to the heat-con sumption of the heat-using equipment. In a multiple-user sys tem, separate controls should !>e installed on each consuming unit, to assure the proper heat-delivery. Safety Controls. In addition to activating controls, the heater must also l>e fitted with the proper safety controls to meet the include: A.S.M.E. requirements. Safety controls slnmltl . 1. A high lempcratwv limit nmlrol operating at the hc-.tter outlet to shut olf the burner in tlie event of an excrssiw temperature rise. ^ 2. A suitable low-limit lem|>erilure eontrol to bold the burner at low lire until the Aruelor * 1248 in tlte system tvacbrs n teni|>er;(ture level of 180*I'\ The low limit temjierature control is essential lrecause the viscosity of Aroclor 1248 is rather high at normal room tem perature. To avoid localized overheating upon start-up, it is not advisable to apply full heat from the burner until all the fluid in the system has attained a viscosity that allows good flow and unimpeded circulation. Cold start-nj>s require slow up-hcats. Burners should be equipped with automatic ignition controls and flame failure controls. In wide-range firing ojMTations, an over-fire draft control will increase? the economy of operation. Induced draft fans are another factor which should lie considered as a means of avoiding the exjHuise of high chimneys. Where they are needed throughout the system, good quality recording or indicating gauges should Im* installed. COOLING EQUIPMENT Where fast reduction of temperature is required suitable, air- or water-cooling installations may be used. If the cooler is to be a water-type unit, it is suggested that stainless steel tubing l>e used for the coils to avoid corrosion on the water side. If a cooler is installed in the system, low temperature Jimit con trols should also be installed to avoid excessive cooling that might raise the viscosity to the point of impeding the circulation in the system. X .fe 7 6 0 < ;0 20 TOWOLDMONOQ34601 0509^9fl FILTERING EQUIPMENT When heating systems operated on Aroclor 1248 are run continuously near the maximum temperature of recommended operation (600F.), it is advisable to provide a filtering device that can be attached to the drain line of the storage tank. In this way discrete particles of dirt that may get into the system can be filtered out periodically. This is an advisable maintenance step since it will eliminate the danger of dirt clogging the valve seats or lodging in parts of the control mechanisms. A small portable filter such as those manufactured by Houan-Erune Cori>oration (Ixrhanon, bid.) or Sparkler Manufac turing Company (Mundelein, 111.) is quite satisfactory. CONNECTIONS and GASKETS In a system operated on Aroclor 1248, welded connec tions are preferable; threaded screw connections should l>e avoided wherever possible. This precaution will minimize leaks with consequent make-up. All connections 1" and over should be of the flanged type fastened with alloy holts to prevent frozen connections. Steel connectors should be used for all instruments and controls. For gasketing, spiral wound gaskets of corrugated stainless steel and asl>cstos combination should be used on all flang<*d connections. TESTING and CLEANING THE SYSTEM When a new system has been installed, it is essential to test the entire system hydrostatically for leaks, and to wash out all the lines to remove dirt, oil films, or pipe scale. Both the cleaning and the testing can be done with a single operation, such as the following: Fill the entire system with a water solution containing 5 pounds of soda ash and 5 pounds of caustic soda for every 1000 pounds (120 gal.) of water used. Thoroughly vent the sys tem at all of the highest points in the piping system to assure complete filling . . . then start the circulating pump. With the pump running, the entire system is next inspected for leaks. Next, turn on the burner at low-fire rate and raise the temperature of the wash solution to 180F. This hot wash solu tion should be circulated continuously through the entire system (heater and all users) for at least 24 hours. At regular intervals a portion of the solution should be drained and replaced by fresh water. This partial draining should be continued at regular in tervals until the drainage from the system is clear. At the end of the 24 hour period, the temperature of the circulating wash solution should he brought up to 241TF. and the fire turned off. The whole system should then be drained and all vents in the piping opened. Residual heat will dry the pipes and the heater through the vents, which should remain oix*n until inspection shows that the system is entirely dry. When all traces of water have dried out, the drains and vents are closed. Aroclor 1248 is then charged into the cleaned, dry sys tem. The circulating pump is started and firing begun at low heat until the Aroclor 1248 has readied a temperature of 250''F. Periodically during this initial up-heating, the lines should be vented every 10-15 minutes for at least two hours to allow any residual moisture or air to escape. After it is certain that all moisture has been eliminated from the system, the entire system should be inspected for leaks with the pump circulating the hot fluid. As a final inspection, the expansion tank should be checked to make sure that the tank is V* full. After this, the burner can be set to full-fire and the system brought up to operating tem perature. When the temperature of operation has been reached all controls should be checked and adjusted so that the burner is regulated for full modulation. When the system is brought to full operating temperature, all pipe lines should be given a final inspection for expansion and bracing. 21 TOWOLDMONOQ34602 GENERAL RECOMMENDATIONS for Operation and Maintenanee The following recommendations are primarily guides for the manner of using Aroclor 1248 in an operating system. They are supplemental to the equipment manufacturers own recommendations for operation and maintenance that relate to the heaters or the heat-using installations themselves. The recommendations for start-up, shut-down, precautions in event of power failure, and periodic check-ups on the fluid and equip ment apply as generally accepted practice on all types and sizes of systems. By following these recommendations, the troublefree service life of the heat transfer fluid will be increased. START-UP When systems have been shut down for week-ends or over-night and the fluid is cooled to room temperature, follow this start-up procedure: 1. Start the circulating pump and check the expansion tank to make certain the Aroclor 1248 is at the proper cold-start level (Tank should be V-full.) 2. Start burner at minimum flame setting and continue full circulation until Aroclor 1248 is heated to 180* F. when measured on the return side of the heater. 3. Turn heater up to full heat. SHUT-DOWN The following procedure will eliminate overheating of the fluid when shutting down: 1. Shut off burner completely with circulating pump still oper ating. Continue to run the circulating pump at full head for at least Vi hour to dissipate high residual heat in the com bustion chamlrer of the burner, 2. Shut off circulating pump at the end of Vt hour and switch off all heater electrical controls. PRECAUTIONS IN COLD WEATHER When heat exchanger is exposed to ambient tempera tures below 50F., it is recommended that unit not be shut down. It is recommended that the burner be turned low and the fluid circulated continuously at about 200F. The unit will then be "at ready" for immediate high temperature operation. PRECAUTIONS IN CASE OF POWER FAILURE In case of power failure, the burner circuit is interrupted by the heater controls. When power comes on, the circulating pump should first be run for a few minutes to eliminate any vapor pockets that might have been formed by the fluids being held static in the hot combustion chamber. If there is no knock ing in the piping system, full-fire may lie resumed immediately. PERIODIC CHECK-UPS The regular maintenance inspection schedule should include the equipment manufacturers recommendations and also inspection of the heat transfer fluid. The following is a listing of check points. 1. Lut>ri<-u(ion of moving parts. 2. Operating fidelity and accuracy of readings of safety controls and temperature limit controls. 3. Inspection of heater titlx's, burner, refractory linings. 4. Periodic cleaning of heater surfaces. 5. Inspection of water cooling at tire circulating pump. 6. Regular repacking of stuffing boxes according to the manu facturer's recommendations. 7. Semi-annual or annual sampling and analysis of Aroclor 1248. Under normal operating conditions not affected by fre quent power failures or accidental overheating, when Aroclor 1248 is operated at 600F. it should not be necessary to check on the condition of the fluid more often than once or twice a year. The analysis for fluid condition is a simple determina tion of viscosity. The information given in Figure 6 serves as a guide to estimate the condition of the fluid, according to vis cosity values. Most users do their own testing; some have the viscosity determination made by an outside laboratory. Customers can have their fluid tested by Monsanto free of charge. A one-quart sample is required, and sample should be carefully packed to avoid breakage in shipment. Samples should be shipped to: Monsanto Chemical Company Organic Chemical Division Industrial Fluid Sales St. Louis, Missouri ,zt>oso 22 0E6OSO i p"i i r : I .I ') ' I l | r f M r11 M I ............ ' i . - -| i'i !- i M */ I i. M } k* L. ' " 'II | "`| I .... I, : ' l' 'i 11 11 'I ' i i i i , i 1 'll ", n i;' 1 11 \ I ! I E3 M i I 1 . \ h"( . in l| . l 1111 .i .1 ...,l '( "I Ml Designing or purchasing equipment for a heating system to be operated with Aroclor as a medium to deliver heat into a process requires consideration of heat transfer characteristics of both the user and the heater. The actual heat which can be absorbed by a user, for example, depends upon the over-all heat transfer coefficient, heat transfer area, and a mean tem perature difference between Aroclor and the material being heated. Both overall heat transfer coefficient and mean temperature difference are. in turn, affected by the flow rate of the Aroclor. This inter-relation of flow rate, heat, and temperature is usually solved by a trial and error procedure as covered in standard reference texts. The approach of Granet-3 may be used to minimize or eliminate trial and error. 1 The following tables and graphs of physical properties and engi neering data are provided a !an aid in layout and design calculations for systems to be operated with Aroclor 1248 as a heat transfer fluid in the liquid phase. ' 1' '' : '11 ': l i ,, Table IV lists properties useful in heat balance calculations by which the flow rate is related to the heat transferred and the temperature change of the Aroclor. This relation is also shown graphically in Figure 10. t The over-all heat transfer coefficient for the heater or user may Ixj estimated by the methods outlined in the texts of McAdams4 or Kern5. This is usually done by combining the individual film coefficient of the Aroclor with other coefficients and conductivities to yield the over-all coefficient. Table V contains physical properties of Aroclor as a function of tem|x*raturc which are needed for calculating the Aroclor film coefficient. Tables VI gives typical film coefficients for'Aroclor flowing through a 0.81 inch i.d. tube. These are listed as a function of temperature and flow rate in a tubular heat exchanger. Other tube sizes would, of course, require a correction for the diameter in the Reynolds and Nussclt group of the equation (from McAdams) given at the top of Tabic VI. Correlations for estimating film coefficients for various material that might be processed by indirect heating may be found in the texts 4 and 5 cited and elsewhere in the literature. ' > For sizing!pipe line? and pumping requirements. Figure 11 shows pressure drop vs. flow rate and pipe size for Aroclor 1248 at temperatures over 300F. Above this-temperature Aroclor 1248 flows freely like water. 23 TOWOLDMONOQ34604 Ttmparatura r C. 32 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390 400 410 430 450 460 490 500 510 520 530 550 570 580 600 630 0 4 10 16 21 27 32 38 43 49 54 60 66 71 77 82 88 93 99 104 110 116 121 127 132 138 143 149 154 160 166 171 177 182 188 193 199 204 210 216 221 227 232 238 243 249 254 260 266 271 277 282 288 293 299 304 310 316 321 327 332 Table 4 THERMODYNAMIC PROPERTIES OF IROCIOR No. 1240 TABLE IV Enthalpy Btu./lbs. 0.000 2.162 4.881 7.616 10.367 13.134 15.917 18.716 21.531 24.362 27.209 30.072 32.951 35.846 38.757 41.784 44.727 47.686 50.661 53.651 56.657 59.679 62.717 65.771 68.841 71.927 74.029 77.147 80.281 83.431 86.597 89.779 92.977 96.191 99.421 102.667 105.929 109.206 112.499 115.808 119.133 122.474 125.831 129.204 132.593 135.998 139.419 142.856 146.309 149.778 153.262 156.762 160.278 163.810 167.358 170.922 174.502 178.098 181.710 185.338 188.982 (Spte.(Hsst) Btu.lbs. F. 0.2695 0.2711 0.2727 0.2743 0.2759 0.2775 0.2791 0.2807 0.2823 0.2839 0.2855 0.2871 0.2887 0.2903 0.2919 0.2935 0.2951 0.2967 0.2982 0.2998 0.3014 0.3030 0.3046 0.3062 0.3078 0.3094 0.3110 0.3126 0.3142 0.3158 0.3174 0.3190 0.3206 0.3222 0.3238 0.3254 0.3269 0.3285 0.3301 0.3317 0.3331 0.3349 0.3365 0.3381 0.3397 0.3413 0.3429 0.3445 0.3461 0.3476 0.3492 0.3508 0.3524 0.3540 0.3556 0.3572 0.3588 0.3604 0.3620 0.3636 0.3652 Oansity Ibs.cg. It 91.6 91.3 90.9 90.6 90.2 89.8 89.5 89.1 88.8 88.4 88.1 87.8 87.4 87.0 86.6 86.2 85.9 85.6 85.2 84.8 84.4 84.1 83.7 83.4 83.1 82.9 82.6 82.3 81.9 81.6 81.2 80.9 80.6 80.2 79.8 79.4 79.1 78.8 78.5 78.2 77.9 77.6 77.2 768 764 761 75.7 754 750 74 7 744 74 1 73 7 734 730 727 724 720 71 7 71.4 7U Ut. 1*1. 12.22 12.19 12.13 12.08 12.03 12.00 11.96 11.91 11.87 11.82 11.77 11.73 11.69 11.64 11.58 11.53 11.47 11.42 11.38 11.34 11.29 11.24 11.18 11.14 11.10 11.06 11.03 10.98 10.94 10.90 10.8S 10.81 10.76 10.71 10.67 10.62 10.57 10.53 1048 10.43 10.39 10.34 10.30 1025 10.20 1016 1011 10 06 10 02 99! 994 990 985 9 9 76 9 71 967 963 958 953 948 SMCifk Gravity 1.47 1.46 1.455 1.45 1.445 1.40 1.432 1.425 1.420 1.414 1.409 1.404 1.400 1.493 1.387 1.381 1.375 1.370 1.365 1.359 1.353 1.348 1.342 1.336 1.331 1.326 1.321 1.316 1.311 1.305 1.300 1.296 1.291 1.286 1.280 1.274 1.269 1.264 1.259 1.253 1.248 1.243 1.237 1.231 1.225 1.220 1.214 1.208 1.202 1.196 1.191 1.186 1.180 1.175 1.170 1.165 1.160 1.155 1.150 1.144 1.138 . Absolute Viscosity ia CantipotSM 850 380 200 115 66 47 32 24 18 14 11 9.1 7.5 6.3 5.2 4.4 3.9 3.35 3.00 2.68 2.38 2.08 1.96 1.82 1.68 1.58 1.46 1.42 1.30 1.22 1.15 1.10 1.05 1.00 0.96 0.91 0.87 0.84 0.80 0.76 0.73 0.71 .068 0.65 0.61 0.60 0.57 0.55 0.53 0.51 0.49 0.47 0.45 0.43 0.42 0.40 039 0.37 0509301 TOWOLDMONOQ34605 FLOW RATES FOR AROCLOR #1248 TOWOLDMONOQ34606 TEMPERATURE DIFFERENTIAL eF OF AROCLOR ENTERING AND LEAVING THE USER t o t 6050 -------1 i* i| H ig U S3\l f. K. 32 40 50 60 70 80 90 200 UO 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 Table 5 0 4 10 16 21 27 32 38 43 49 54 60 66 71 77 82 88 93 99 104 110 116 121 127 132 138 143 149 154 THERMODYNAMIC PROPERTIES of AROCLOH 1248 PRANDTl Absofcria Viscosity Lbs. Mr. Ft k Tbormfl Contfoctivity 6t. Ft Hr. *T. k rvrL k J Tiawntiw F. C. Absakrta Viscosity Lbs. "ST k Tharml CawdacliaMy Bt. Ft Mr. *F. 2060 960 485 278 160 114 77.5 58.0 43.5 33.8 26.6 22.0 18.2 15.2 12.6 10.6 9.45 8.10 7.26 6.48 5.76 5.03 4.75 4.40 4.07 3.83 0.0577 .0576 0.575 .0574 .0573 .0572 .0570 .0569 .0568 .0566 .0565 .0564 .0563 .0562 .0560 .0559 .0558 .0557 .0555 .0554 .0553 .0552 .0550 .0549 .0548 .0547 .0546 .0544 .0543 9844 4430 2353 1361 789 566 388 293 221 173 137 115 95 80 67 57 51.1 44.1 39.8 35.9 32.1 28.2 26.8 25.1 23.4 222 39.5 28.7 22.3 17.9 14.4 12.6 10.8 9.7 8.7 7.88 7.15 6.68 6.18 5.78 5.38 5.05 4.83 4.55 4.36 4.18 4.00 3.81 3.73 3.63 3.53 3.45 ' 320 330 340 350 360 370 380 390 400 410 420 430 440 450 460 470 480 490 500 510 520 530 540 550 560 570 580 590 600 160 166 171 177 182 188 193 199 204 210 216 221 227 232 238 243 249 254 260 266 271 277 282 288 293 299 304 310 316 3.53 3.34 3.14 2.95 2.78 2.66 2.54 2.42 2.32 2.20 2.10 2.03 1.93 1.83 1.76 1.71 1.64 1.57 1.51 1.45 1.38 1.33 1.28 1.22 1.18' 1.13 1.09 1.04 1.01 .0542 .0541 .0540 .0539 .0537 .0536 .0535 .0534 .0532 .0531 .0530 .0529 .0527 .0526 .0525 .0524 .0523 .0521 .0520 .0519 .0518 .0516 .0515 .0514 .0513 .0512 .0510 .0509 .0508 CbAS k . 20.6 19.6 18.5 17.5 16.7 16.1 15.4 14.8 14.3 13.7 13.1 12.7 12.3 11.7 11.3 11.0 10.7 10.3 10.0 9.67 9.26 9.00 8.72 8.36 8.14 7.85 7.63 7.33 7.16 ' * * 3.35 3.29 3.22 3.15 3.08 3.04 2.99 2.94 2.90 2.85 2.80 2.76 2.73 2.68 2.64 2.61 2.58 2.54 2.51 2.46 2.43 2.40 2.37 2.34 2.31 2.28 2.25 2.22 2.20 TOWOLDMONOQ34607 4 F. 150 200 250 300 350 400 450 500 550 600 Tabic 6 HEAT TRANSFER DATA for AROCLOR 1248 ,, (FILM COEFFICIENT) E] [t] '8 Pf] Based an flew through 041' 1.0. tub* (1' 0. D. x 13 ga.) expressed la Btu./s*. ft. hr. F. FLOW ATE 6PM 14 2.0 33.5 40.5 454 49.0 53.3 56.3 60.5 644 44.9 58.5 70.1 79.0 85.5 . jj . 98 105 112 3.0 63.4 80.9 97 109 118 128 136 145 155 4.0 78.7 102 122 137 149 162 171 183 195 5.0 94.0 122 146 164 178 193 204 219 233 64 83.2 109 141 169 190 206 224 236 253 269 74 864 124 159 191 215 232 253 267 286 305 84 93.8 138 177 212 239 259 282 297 319 339 94 103 151 195 233 262 284 309 327 350 373 10.0 114 164 212 254 286 309 336 356 381 405 Calculations lor other pipa sbos caa ho aude using the data (oaad la Tables IV aad V. No film ceefldeats were calculated for dew rates where the Reyaelds nuaiher was less thae 2100. 114 123 179 229 274 309 334 363 383 411 437 124 130 191 245 294 331 358 388 411 441 469 ,930* IT o f 27 TOWOLDMONOQ34608 l FRICTION LOSSES IN SYSTEM PIPING i AROCLOR 1248, ABOVE 300F. TOWOLDMONOQ34609 0509305 IlNl.lH II 1 I nil I I, :i II ,l.| VI.1 | I 0t>0930b ; * . 1.11* i . <1 . \ * >. i \ r. ,t, j mii ii,ii 29 . r TOWOLDMONOQ34610 OS09307 1 i I 1 30 gases for three passes over the Arodor coil. The top is a steel plate. on each Arodor heater or both stages can be used on either Arodor heater. TOWOLDMONOQ34611 A 40,000 Btu. per hour electrically heated portable heat exchanger used to heat vessels of about 50 gallons working capac ity. This unit was built for a variety of small scale chemical reactions. It was initially designed to vaporize approxi mately 200 ibs./hr. of an organic com pound which has a heat .of vaporization of 150 Btu. per pound; a 30% heat loss was allowed for. Experience with the heater indicates that a horizontal rather than the vertical mounting of the immer sion heater (at operator's left) would have been more satisfactory. A 4,000,000 Btu./hr. forced circulation International LaMont heater. Control panel for a 3,000,000 Btu./hr. International LaMont heater that oper ates th; 3,500 gallon, glass-lined kettle shown on the left This kettle is the largest of its kind in the United States. Commercial heaters operating on Arodor 1248 are available in any capacity desired. This is a 1,200.000 Btu./hr. installation. 31 TOWOLDMONOQ34612 050S308 A pitot plant resin processing vessel operated on indirect heat transferred by Arodor 1248. Vessel and heater ate mounted together in one unit. This 500,000 Btu./hr. forced circulation heater is electrically heated and designed for a liquid temperature of 500eF. The construction is similar to a double pipe heat exchanger with the electric heating elements in the inner pipe; the Arodor 1248 circulates through the annular space between inner and outer pipe. The liquid Arodor 1248 is delivered from the heater at a temperature of 500F. and heats the contents of a jacketed kettle with a batch capacity of 1.000 gallons. This design for a forced cir culation heater was de veloped by Cleaver Brooks Company. i.iri.nATi hi. < in:i) 1. Monsanto Chemical Co., St. Louis, Mo., Application Data Bulletin 0-115 (1954). . 2. Sullivan, M. V., Wolfe, J. K., and Zisinan, W. A., "Indus. Eng. Chem." 39, 1607 (1947). 3. Cranet, II, "Heat Transfer Performance Curves", Chemical Engineering, P. 187-190, March, 1955. 4. McAdams, W. H., "Heat-Transmission", McGraw-Hill Book Co., Inc., New York, (1942). , 5. Kem, D. Q., "Process Heat Transfer", McGraw-Hill Book Co., Inc., New York, (1950). b O tt> 0 ^ 32 TOWOLDMONOQ34613 *.j.. <j i >1 >>ii. LIQUID HEAT TRANSFER FLUIE Temperatures up to 600F. Long-lasting, trouble-free service Fire-resistant, non-corrosive Operates in un-pressured, minimum cost equipment Monsanto supplies Aroclor 1248, but not the heat exchanger*. Monsanto will be happy to rerommprtd source* of supply. i TOWOLDMONOQ34614 0509310 r T7 t i Regional Officei: ATLANTA BOSTON CIIICACO CINCINNATI CLEVELAND DETROIT HOUSTON LOS ANGELES MONSANTO CHEMICAL COMPANY NEW YOKE SAN FRANCISCO ORCANIC DIVISION ST. LOUIS, MO SEATTLE ST. LOUIS MINNEAPOLIS-ST. PAUL WILMINCTON TOWOLDMONOQ34615