Document B5kM6qVyKkdK1m8eZBBMzNO3j
I
l
Facility:
Monsanto Company
N.G. Krummrtch Plant
Route 3
'
Seuget, IL 62201
' '
Date of Inspection:
I Participants:
`
- January 27, 1976
Monsanto Paul Helsler Clarence Buckley
' '
.
U.S. Environmental Protection Agency
Edwin Zylstra
John Connell
.
' Charles Miller
Background:
':
. . '
.
Monsanto is the sole manufacturer of PCB in the United States, Production figures for the first nine months of 1975 are listed below:
Aroclor 1016 .1242 1254
Thousands of Pounds
.. ' 10350 . 5120 . 6980
Starting during the latter part of 1972,' the only use for PCB compounds
is tn the manufacture of transformers and capacitors.
.
.1 t
'
'.
Process:
The chlortnator ts charged with, biphenyl and ferric chloride (catalyst) and then heated. Vaporized chlorine is fed into the chlortnator. The
contact time varies from 12 to 36 hours, depending on the type of Arocl or to he produced, which determines the degree of chlorination. The vapor
from the chlortnator (HC1 containing PCB) goes to the scrubber where it ts washed with liquid Arocl or. The gaseous MCI is sent to the purification tectton of the plant. The crude Aroclor goes to the Blower tank where
tt ts blown with dry air for several hours. The air is scrubbed with water and vented to the atmosphere through a demister, the crude product ts sent to a storage tank, where a few tenths of 1* of alkali is added to
react with any Remaining hydrogen chloride or ferric chloride.
I.
MONS 048706
2
i .' -
The method of distillation of the raw Aroclor varies 'depending upon the product to be produced. For types 12S4, 1242, and 1221, the process Is
the same. Each is distilled In a vacuum still, the condensate being the finished product and the bottoms betng the itontars which are sent to incineration. For Aroclor 1016, the crude aroclor is distilled in a vacuum distillation-tower. The steam from the steam jet ejectors is partially condensed; the condensate being discharged into the plant discharge sump and the vapor exhausted to atmosphere. The overhead from the distillation tower is the product 1016 and is sent to storage. The bottoms are sent through another chlorination and distillation cycle. The overhead from this still is the finished product and the bottoms are the
Nontars which are sent to incineration. The three possible places where
PCB can escape into, the atmosphere are; vapor from jet ejectors,- exhaust from the scrubber; and surface area evaporation (in general).
All aroclors are stored at 150aF with a layer of nitrogen on top of the
liquid.
Incineration:
..
..
There are three points in the process that go to the incinerator: Montars,
bottoms from separator sump, collection from all drip pans. In addition waste material from the users of PCB is sent to Monsanto to be destroyed.
The type and concentration of these waste are unknown but it is estimated
that they contain about 90% PCB. The amount of contaminated waste disposed
of for the first nine months of 1975 is listed below:
l l
Thousands of Pound:
Customer returns, records exists Monsanto, records exists
Total receipts Destroyed by incineration
1109 322 1431 2808
The'liquid waste stream is steam atomized and fed into the fire box. The
feed is Incinerated at a temperature above2200"F with natural gas used for
combustion with 52 excess oxygen and a retention time of 2-3 seconds. The
`gases go through a quench pot, the exhaust of which passes through a venturi
scrubber and then through a packed tower which Is irrigated by the weak
muriatic acid originating from the quench pot. The exhausts are vented
to atmosphere thrpugh a demister and are monitored.
-'
HONS 048707
r
Loading and Unloading:
The majority of the PCB components and the products made using PCB are
liquid and are transported in bulk or in steel drums. Bulk shipments are
made in railroad tank car and tank trucks. Haste material shipped In from
other locations in 55 gallon drums or tank trucks are unloaded into a
concrete pit; the material in this pit is periodically pumped to one of
four 20,000 gallon Incinerator waste feed tanks. The waste material that
Is shipped in by rail truck is unloaded into a 500,000 gallon storage tank
and is pumped into the feed tanks when required. In the truck or railcar
loading area, drainage is directed Into a small concrete pit which is
periodically pumped into the basins located in the manufacturing area.
Relief valve lines and atmosphere vents are routed through catch tanks or
are redirected to underground settling basins.
....
r
MONS 0*8708